Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.2 CrAccepted-AOC NOT SPECIFIED | ₹1.2 Cr | L1 | Accepted-AOC Bidder quoted L1 rates |
| 2 | L2₹1.2 Cr+₹1.6 L (1.40%)Rejected-Finance V P O SAROTARI TEHSIL BAROH DISTRICT KANGRA PIN 176037 HP | KANGRA | HIMACHAL PRADESH | 176037 | ₹1.2 Cr+₹1.6 L (1.40%) | L2 | Rejected-Finance Bidder not quoted L1 rates |
| 3 | L3₹1.2 Cr+₹1.9 L (1.61%)Rejected-Finance 3 1 4 GOPINATH BAZAR DELHI CANTT 110 010 | NEW DELHI | DELHI | 110010 | ₹1.2 Cr+₹1.9 L (1.61%) | L3 | Rejected-Finance Bidder not quoted L1 rates |
| 4 | L4₹1.2 Cr+₹3.2 L (2.76%)Rejected-Finance | ₹1.2 Cr+₹3.2 L (2.76%) | L4 | Rejected-Finance Bidder not quoted L1 rates |
| 5 | L5₹1.2 Cr+₹3.3 L (2.81%)Rejected-Finance 12 BHARTI AARTIST COLONY VIKAS MARG NEW DELHI 110092 | EAST | DELHI | 110092 | ₹1.2 Cr+₹3.3 L (2.81%) | L5 | Rejected-Finance Bidder not quoted L1 rates |
Tender Value
₹1.2 Cr
EMD Value
₹2 L
Closing Date
17 Feb 2024, 6:00 pmClosed
COMMANDER WORKS ENGINEER PUNE
HEADQUARTERS COMMANDER WORKS ENGINEERS GEN CARIAPPA MARG, PUNE-411 001
81760 SPECIAL REPAIR FOR REPLACEMENT OF BER DG SETS AT NDA UNDER GE NDA KHADAKWASLA
2024_MES_638205_1
81760 CWE PUNE
Open Tender
Electrical and Maintenance Works
Item Rate
273 days
GE NDA KHADAKWASLA
AS PER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹1,000
GE NDA KHADAKWASLA
₹2 L
Yes
9 May 2024
19 Jan 2024
19 Feb 2024
19 Jan 2024
17 Feb 2024
10 Feb 2024
Amount
Supply, Install, testing & commissioning of Silent type Diesel Engine Driven Generating set, 415 Volts, 320KVA/256KW, 3 Phase, 4 wired, 0.8 power factor, 50Hzs, 1500 RPM, self excited, self regulated with brushless excitation screen protected drip proof IP23 enclosure suitable for ambient condition at Pune fully wired Alternantor AC for output of 320 KVA continuously directly coupled with diesel engine water/liquid cooled, mounted on common base frame complete with acoustic enclosure (canopy) with CPCB-IV norms, fuel line & accessories, control panel showing standard parameters of Engine and Alternator, AMF Panel with control cable of suitable Amps as per DG set Capacity , exhaust pipe, fuel tank, anti vibration pads and other standard accessories , conforming to ISO -8528, IS 10002, BS-5514, IS-4722, 13364, BS EN 60034-I, PCC foundation work as per manufacturers instructions including earth work or demolition of existing foundation as per site requirement, and comprising of the folllowing, complete all as specified and directed.
SER ITEM No. 1.00 Contd.... (A) Alternator - Standard design alternator rated capacity of 256KW/320 KVA net out put at site after considering derating as per site condition at 0.8 (lagging)power factor,AC, 3 Phase, 4 wire, 415 Volts, 50 HZ, 1500 RPM, self excited, self regulated with brushless excitation screen protected drip proof IP23 enclosure, brushless design with windings in pole faces, insulation class 'H' , Temp rise class - 'H" and Voltage regulation of +/- 1% at rated voltage from No load to Full load,directly coupled with diesel engine through flexible coupling. The Alternator shall be suitable for tropical climate and shall conform to IS- 4722 , 13364 and BS EN60034-1 as amended upto date and shall be in position to generate supply with frequency regulation within +/- 1% tolerance. (B) Diesel Engine: Adequate capacity of Diesel Engine as accepted by the accepting Officer based on OEM's technical details Water/liqiud cooled Diesel Engine to drive independently above the alternator cap and after considering derating as per site condition after generating and reducing power consumed by accessories directly coupled through flexible coupling, Common Rail Direct injection(CDRi), cold starting 1500RPM, 4 stroke, 6 cylinder (inline), turbo charged to deliver suitable BHP at 1500 RPM under NTP conditions of BS-5514 and conforming to IS 10002 and ISO-8528, the engine is prime rated with 10% over load capacity for one hour in any 12 continuous hours of operation. The engine shall be provided with electrical starting arrangments and shall give the electrical out put of 320 KVA at 0.8 power factor, 415 volts including standard accessories all as specified and required for safe handling and operation. The accessories comprising of following: -
SER ITEM No. 1.00 Contd.... (i) Radiator with blower fan including guard. (ii) Pipe coupling for engine cooling system piping. (iii) Corrossion in-hibitor coolant. (iv) Paper element filters for fuel, Lube oil, Bypass. (v) Fly wheel housing and flywheel. (vi) Engine bearing mechanism in flywheel housing. (vii) Flexible coupling. (viii) Dry type air cleaners. (ix) Residential silencer. (x) Stainless Steel exhust flexible bellows. (xi) Vaccum Indicators. (xii) Electric starter. (xiii) 12/24V Battery of suitable AH Cap with Copper lead, Lugs and charging indicator. (xiv) Exhaust piping made out of heavy duty mild steel pipe 'C' class of length 3.5 metres above the building height (height of the building + 3.5 metre) or as per recommendations of OEM to meet CPCB-IV norms inclusive of all accessories and hardware, neccessary support steel structure stack including mineral wool insulation 2 inch thick suitable for 400 degree celcius temperature cladded with aluminium sheet for the entire length of exhaust pipe. (xv) Exhaust gas driven turbo charger and Diesel Exhaust Fluid (DEF) tank of optimized capacity. (xvi) Fuel Injection eqpt with Electronic governor. (xvii) First fill lube oil, coolant and diesel during commissioning & testing.
SER ITEM No. 1.00 Contd.... (xviii) Silencer : Residential type, Fuel Hoses, Lubricating Oil Pump, Air Cleaner Dry type, Electronic Governor/ as recommended by OEM. (xix) Generator Monitoring Panel : comprising of standard items as per standard practice ignition switch start & stop arrangement, Indication for Engine parameters, Hrs run meter, rpm meter, Oil pressure indicator, water/ Coolant temp indicator, Battery Volt display ( State of the art Genset Controller). AMF Panel suitable for Outdoor installations with all required fixing and Safety arrangements. (xx) Safety Controls : Engine low Lub Oil Pressure, high water temp and over speeding of engine. (xxi) AVM Pads built or seperately mounted on manufacturer's base frame or as recommended by OEM. (xxii) Base frame : made out of ISMC of sturdy design made of MS channel with necessary reinforcement and predetermined holes. (xxiii) Fuel Tank : Daily service fuel tank ( as recommended by OEM) with calibrated level indicator, stop cock, drain plug, complete on a common base inside the acoustic enclosure, inbuilt tank having cap to store DHPP for 8-12 Hrs running on full load. (xxiv) Rubber mating of LV grade 19mm thick of suitable size chequred type ISI marked to be laid in front of control Panel shall be provided.
SER ITEM No. 1.00 Contd.... (xxiv) Acoustic Enclosure shall be Powder Coated after pre-treatment Process, Outer body and door made of CRCA sheet of 1.6mm thick, base frame painted with epoxy based black shade sound insulation 100mm thick rockwool (64kg/cum), illuminated with suitable cap LED lamp fitting with switch complete as recommended by OEM suitable for above mentioned DG Cap. (xxv) NAL Approved as per CPCB-IV Norms. (xxvi) Batteries and Control Panel shall be inside the enclosure. (xxvi) External Emergency stop push button. (xxvii) The Noise level shall be 75dB Max at 1 meter under free field condition. (xxviii) The quoted rate shall be deemed to be inclusive of 12 Hrs test run with required qty of Diesel at site including of half an hour on 10% overload in presence of representative detailed by Accepting Officer and all necessary arrangements are to be made by the contractor for test. Testing will be carried out till satisfication of Testing Officer. (xxix) Specification & Drawings for PCC foundation as recommended by OEM to be provided by the contractor within above quoted rates.
SER ITEM No. 1.00 Contd.... AMF Panel consisting of followings: xxi) Control Terminal Block 2.5/4sqmm-1 Set xxii) Control Wire-1/1.5/2.5Sqmm 5mtr approx each xxiii) Conical Insulator 50x10mm -1 Set xxiv) Gasket 25x3mm -1 Set xxv) Lugs, Ferrules ( Control) 1.5/2.5sqmm -1 Set xxv) Lugs/ ferrules (1.5/2.5sqmm) -1 Set xxvi) Door Knobs with Open/ Close Sticker- 6 Nos xxvii) PVC Channel, Din Rail Channel 45x45/25x45-1 Set xxviiii) Name Plate, Lables& Stickers-1 Set xxix) Eye Bolt-4 Nos xxx) bas bar sleeve-1 Set
Supply, Install, testing & commissioning of Silent type Diesel Engine Driven Generating set, 415 Volts, 250KVA/200KW, 3 Phase, 4 wired, 0.8 power factor,50Hzs, 1500 RPM, self excited, self regulated with brushless excitation screen protected drip proof IP23 enclosure suitable for ambient condition at Pune fully wired Alternantor AC for output of 250 KVA continuously directly coupled with diesel engine water/liquid cooled, mounted on common base frame complete with acoustic enclosure (canopy) with CPCB-IV norms, fuel line & accessories, control panel showing standard parameters of Engine and Alternator, AMF Panel with control cable of suitable Amps as per DG set Capacity , exhaust pipe, fuel tank, anti vibration pads and other standard accessories , conforming to ISO -8528, IS 10002, BS-5514, IS-4722, 13364, BS EN 60034-I, PCC foundation work as per manufacturers instructions including earth work or demolition of existing foundation as per site requirement, and comprising of the folllowing, complete all as specified and directed.
SER ITEM No. 2.00 Contd.... (A) Alternator - Standard design alternator rated capacity of 250 KVA/200KW net out put at site after considering derating as per site condition at 0.8 (lagging)power factor,AC, 3 Phase, 4 wire, 415 Volts, 50 HZ, 1500 RPM, self excited, self regulated with brushless excitation screen protected drip proof IP23 enclosure, brushless design with windings in pole faces, insulation class 'H' ,Temp rise class - 'H" and Voltage regulation of +/- 1% at rated voltage from No load to Full load,directly coupled with diesel engine through flexible coupling. The Alternator shall be suitable for tropical climate and shall conform to IS- 4722 , 13364 and BS EN60034-1 as amended upto date and shall be in position to generate supply with frequency regulation within +/- 1% tolerance. (B) Diesel Engine: Adequate capacity of Diesel Engine as accepted by the accepting Officer based on OEM's technical details Water/liqiud cooled Diesel Engine to drive independently above the alternator cap and after considering derating as per site condition after generating and reducing power consumed by accessories directly coupled through flexible coupling, Common Rail Direct injection(CDRi), cold starting 1500RPM, 4 stroke, 6 cylinder (inline), turbo charged to deliver suitable BHP at 1500 RPM under NTP conditions of BS-5514 and conforming to IS 10002 and ISO-8528, the engine is prime rated with 10% over load capacity for one hour in any 12 continuous hours of operation. The engine shall be provided with electrical starting arrangments and shall give the electrical out put of 250 KVA at 0.8 power factor, 415 volts including standard accessories all as specified and required for safe handling and operation. The accessories comprising of following: -
SER ITEM No. 2.00 Contd.... (i) Radiator with blower fan including guard. (ii) Pipe coupling for engine cooling system piping. (iii) Corrossion in-hibitor coolant. (iv) Paper element filters for fuel, Lube oil, Bypass. (v) Fly wheel housing and flywheel. (vi) Engine bearing mechanism in flywheel housing. (vii) Flexible coupling. (viii) Dry type air cleaners. (ix) Residential silencer. (x) Stainless Steel exhust flexible bellows. (xi) Vaccum indicators. (xii) Electric starter. (xiii) 12/24V Battery of suitable AH Cap with Copper lead, Lugs and charging indicator. (xiv) Exhaust piping made out of heavy duty mild steel pipe 'C' class of length 3.5 metres above the building height (height of the building + 3.5 metre) or as per recommendations of OEM to meet CPCB-IV norms inclusive of all accessories and hardware, neccessary support steel structure stack including mineral wool insulation 2 inch thick suitable for 400 degree celcius temperature cladded with aluminium sheet for the entire length of exhaust pipe. (xv) Exhaust gas driven turbo charger and Diesel Exhaust Fluid (DEF) tank of optimized capacity. (xvi) Fuel Injection eqpt with Electronic governor.
SER ITEM No. 2.00 Contd.... (xvii) First fill lube oil, coolant and diesel during commissioning & testing. (xviii) Silencer : Residential type, Fuel Hoses, Lubricating Oil Pump, Air Cleaner Dry type, Electronic Governor/ as recommended by OEM. (xix) Generator Monitoring Panel : comprising of standard items as per standard practice ignition switch start & stop arrangement, Indication for Engine parameters, Hrs run meter, rpm meter, Oil pressure indicator, water/ Coolant temp indicator, Battery Volt display ( State of the art Genset Controller). AMF Panel suitable for Outdoor installations with all required fixing and Safety arrangements. (xx) Safety Controls : Engine low Lub Oil Pressure, high water temp and over speeding of engine. (xxi) AVM Pads built or seperately mounted on manufacturer's base frame or as recommended by OEM. (xxii) Base frame : made out of ISMC of sturdy design made of MS channel with necessary reinforcement and predetermined holes. (xxiii) Fuel Tank : Daily service fuel tank ( as recommended by OEM) with calibrated level indicator, stop cock, drain plug, complete on a common base inside the acoustic enclosure, inbuilt tank having cap to store DHPP for 8-12 Hrs running on full load.
SER ITEM No. 2.00 Contd.... (xxiv) Rubber mating of LV grade 19mm thick of suitable size chequred type ISI marked to be laid in front of control Panel shall be provided. (xxiv) Acoustic Enclosure shall be Powder Coated after pre-treatment Process, Outer body and door made of CRCA sheet of 1.6mm thick, base frame painted with epoxy based black shade sound insulation 100mm thick rockwool (64kg/cum), illuminated with suitable cap LED lamp fitting with switch complete as recommended by OEM suitable for above mentioned DG Cap. (xxv) NAL Approved as per CPCB-IV Norms. (xxvi) Batteries and Control Panel shall be inside the enclosure. (xxvi) External Emergency stop push button. (xxvii) The Noise level shall be 75dB max at 1 meter under free field condition. (xxviii) The quoted rate shall be deemed to be inclusive of 12 Hrs test run with required qty of Diesel at site including of half an hour on 10% overload in presence of representative detailed by Accepting Officer and all necessary arrangements are to be made by the contractor for test. Testing will be carried out till satisfication of Testing Officer. (xxix) Specification & Drawings for PCC foundation as recommended by OEM to be provided by the contractor within above quoted rates.
SER ITEM No. 2.00 Contd.... AMF Panel consisting of followings: xxi) Control Terminal Block 2.5/4sqmm-1 Set xxii) Control Wire-1/1.5/2.5Sqmm 5mtr approx each xxiii) Conical Insulator 50x10mm -1 Set xxiv) Gasket 25x3mm -1 Set xxv) Lugs, Ferrules ( Control) 1.5/2.5sqmm -1 Set xxv) Lugs/ ferrules (1.5/2.5sqmm) -1 Set xxvi) Door Knobs with Open/ Close Sticker- 6 Nos xxvii) PVC Channel, Din Rail Channel 45x45/25x45-1 Set xxviiii) Name Plate, Lables& Stickers-1 Set xxix) Eye Bolt-4 Nos xxx) bas bar sleeve-1 Set
Supply, Install, testing & commissioning of Silent type Diesel Engine Driven Generating set, 415 Volts, 58.5KVA/46.8KW, 3 Phase, 4 wired, 0.8 power factor,50Hzs, 1500 RPM, self excited, self regulated with brushless excitation screen protected drip proof IP23 enclosure suitable for ambient condition at Pune fully wired Alternantor AC for output of 58.5 KVA continuously directly coupled with diesel engine water/liquid cooled, mounted on common base frame complete with acoustic enclosure (canopy) with CPCB-IV norms, fuel line & accessories, control panel showing standard parameters of Engine and Alternator, AMF Panel with control cable of suitable Amps as per DG set Capacity , exhaust pipe, fuel tank, anti vibration pads and other standard accessories , conforming to ISO -8528, IS 10002, BS-5514, IS-4722, 13364, BS EN 60034-I, PCC foundation work as per manufacturers instructions including earth work or demolition of existing foundation as per site requirement, and comprising of the folllowing, complete all as specified and directed.
SER ITEM No. 3.00 Contd.... (A) Alternator - Standard design alternator rated capacity of 58.5KVA/46.8KW net out put at site after considering derating as per site condition at 0.8 (lagging)power factor,AC, 3 Phase, 4 wire, 415 Volts, 50 HZ, 1500 RPM, self excited, self regulated with brushless excitation screen protected drip proof IP23 enclosure, brushless design with windings in pole faces, insulation class 'H' , Temp rise class - 'H" and Voltage regulation of +/- 1% at rated voltage from No load to Full load,directly coupled with diesel engine through flexible coupling. The Alternator shall be suitable for tropical climate and shall conform to IS- 4722 , 13364 and BS EN60034-1 as amended upto date and shall be in position to generate supply with frequency regulation within +/- 1% tolerance. (B) Diesel Engine: Adequate capacity of Diesel Engine as accepted by the accepting Officer based on OEM's technical details Water/liqiud cooled Diesel Engine to drive independently above the alternator cap and after considering derating as per site condition after generating and reducing power consumed by accessories directly coupled through flexible coupling, Common Rail Direct injection(CDRi), cold starting 1500RPM, 4 stroke, 4 cylinder (inline), turbo charged to deliver suitable BHP at 1500 RPM under NTP conditions of BS-5514 and conforming to IS 10002 and ISO-8528, the engine is prime rated with 10% over load capacity for one hour in any 12 continuous hours of operation. The engine shall be provided with electrical starting arrangments and shall give the electrical out put of 58.5 KVA at 0.8 power factor, 415 volts including standard accessories all as specified and required for safe handling and operation. The accessories comprising of following: -
SER ITEM No. 3.00 Contd.... (i) Radiator with blower fan including guard. (ii) Pipe coupling for engine cooling system piping. (iii) Corrossion in-hibitor coolant. (iv) Paper element filters for fuel, Lube oil, Bypass. (v) Fly wheel housing and flywheel. (vi) Engine bearing mechanism in flywheel housing. (vii) Flexible coupling. (viii) Dry type air cleaners. (ix) Residential silencer. (x) Stainless Steel exhust flexible bellows. (xi) Vaccum indicators. (xii) Electric starter. (xiii) 12/24V Battery of suitable AH Cap with Copper lead, Lugs and charging indicator. (xiv) Exhaust piping made out of heavy duty mild steel pipe 'C' class of length 3.5 metres above the building height (height of the building + 3.5 metre) or as per recommendations of OEM to meet CPCB-IV norms inclusive of all accessories and hardware, neccessary support steel structure stack including mineral wool insulation 2 inch thick suitable for 400 degree celcius temperature cladded with aluminium sheet for the entire length of exhaust pipe. (xv) Exhaust gas driven turbo charger and Diesel Exhaust Fluid (DEF) tank of optimized capacity. (xvi) Fuel Injection eqpt with Electronic governor.
SER ITEM No. 3.00 Contd.... (xvii) First fill lube oil, coolant and diesel during commissioning & testing. (xviii) Silencer : Residential type, Fuel Hoses, Lubricating Oil Pump, Air Cleaner Dry type, Electronic Governor/ as recommended by OEM. (xix) Generator Monitoring Panel : comprising of standard items as per standard practice ignition switch start & stop arrangement, Indication for Engine parameters, Hrs run meter, rpm meter, Oil pressure indicator, water/ Coolant temp indicator, Battery Volt display ( State of the art Genset Controller). AMF Panel suitable for Outdoor installations with all required fixing and Safety arrangements. (xx) Safety Controls : Engine low Lub Oil Pressure, high water temp and over speeding of engine. (xxi) AVM Pads built or seperately mounted on manufacturer's base frame or as recommended by OEM. (xxii) Base frame : made out of ISMC of sturdy design made of MS channel with necessary reinforcement and predetermined holes. (xxiii) Fuel Tank : Daily service fuel tank ( as recommended by OEM) with calibrated level indicator, stop cock, drain plug, complete on a common base inside the acoustic enclosure, inbuilt tank having cap to store DHPP for 8-12 Hrs running on full load.
SER ITEM No. 3.00 Contd.... (xxiv) Rubber mating of LV grade 19mm thick of suitable size chequred type ISI marked to be laid in front of control Panel shall be provided. (xxv) Acoustic Enclosure shall be Powder Coated after pre-treatment Process, Outer body and door made of CRCA sheet of 1.6mm thick, base frame painted with epoxy based black shade sound insulation 100mm thick rockwool (64kg/cum), illuminated with suitable cap LED lamp fitting with switch complete as recommended by OEM suitable for above mentioned DG Cap. (xxvi) NAL Approved as per CPCB-IV Norms. (xxvi) Batteries and Control Panel shall be inside the enclosure. (xxvii) External Emergency stop push button. (xxviii) The Noise level shall be 75dB max at 1 meter under free field condition. (xxix) The quoted rate shall be deemed to be inclusive of 12 Hrs test run with required qty of Diesel at site including of half an hour on 10% overload in presence of representative detailed by Accepting Officer and all necessary arrangements are to be made by the contractor for test. Testing will be carried out till satisfication of Testing Officer. (xxx) Specification & Drawings for PCC foundation as recommended by OEM to be provided by the contractor within above quoted rates.
SER ITEM No. 3.00 Contd.... AMF Panel consisting of followings: xix) Battery charger, 12V, 10A-1 NOs xx) Neutral Link-1set xxi) Control Terminal Block 2.5/4sqmm-1 Set xxii) Control Wire-1/1.5/2.5Sqmm 5mtr approx each xxiii) Conical Insulator 50x10mm -1 Set xxiv) Gasket 25x3mm -1 Set xxv) Lugs, Ferrules ( Control) 1.5/2.5sqmm -1 Set xxv) Lugs/ ferrules (1.5/2.5sqmm) -1 Set xxvi) Door Knobs with Open/ Close Sticker- 6 Nos xxvii) PVC Channel, Din Rail Channel 45x45/25x45-1 Set xxviiii) Name Plate, Lables& Stickers-1 Set xxix) Eye Bolt-4 Nos xxx) bas bar sleeve-1 Set
Supply, Install, testing & commissioning of Silent type Diesel Engine Driven Generating set, 415 Volts, 30KVA/24KW, 3 Phase, 4 wired, 0.8 power factor,50Hzs, 1500 RPM, self excited, self regulated with brushless excitation screen protected drip proof IP23 enclosure suitable for ambient condition at Pune fully wired Alternantor AC for output of 30 KVA continuously directly coupled with diesel engine water/liquid cooled, mounted on common base frame complete with acoustic enclosure (canopy) with CPCB-IV norms, fuel line & accessories, control panel showing standard parameters of Engine and Alternator, AMF Panel with control cable of suitable Amps as per DG set Capacity , exhaust pipe, fuel tank, anti vibration pads and other standard accessories , conforming to ISO -8528, IS 10002, BS-5514, IS-4722, 13364, BS EN 60034-I, PCC foundation work as per manufacturers instructions including earth work or demolition of existing foundation as per site requirement, and comprising of the folllowing, complete all as specified and directed.
SER ITEM No. 4.00 Contd.... (A) Alternator - Standard design alternator rated capacity of 30KVA/24KW net out put at site after considering derating as per site condition at 0.8 (lagging)power factor,AC, 3 Phase, 4 wire, 415 Volts, 50 HZ, 1500 RPM, self excited, self regulated with brushless excitation screen protected drip proof IP23 enclosure, brushless design with windings in pole faces, insulation class 'H' , Temp rise class - 'H" and Voltage regulation of +/- 1% at rated voltage from No load to Full load,directly coupled with diesel engine through flexible coupling. The Alternator shall be suitable for tropical climate and shall conform to IS- 4722 , 13364 and BS EN60034-1 as amended upto date and shall be in position to generate supply with frequency regulation within +/- 1% tolerance. (B) Diesel Engine: Adequate capacity of Diesel Engine as accepted by the accepting Officer based on OEM's technical details Water/liqiud cooled Diesel Engine to drive independently above the alternator cap and after considering derating as per site condition after generating and reducing power consumed by accessories directly coupled through flexible coupling, Common Rail Direct injection(CDRi), cold starting 1500RPM, 4 stroke, 3 cylinder (inline), turbo charged to deliver suitable BHP at 1500 RPM under NTP conditions of BS-5514 and conforming to IS 10002 and ISO-8528, the engine is prime rated with 10% over load capacity for one hour in any 12 continuous hours of operation. The engine shall be provided with electrical starting arrangments and shall give the electrical out put of 30KVA at 0.8 power factor, 415 volts including standard accessories all as specified and required for safe handling and operation. The accessories comprising of following: -
SER ITEM No. 4.00 Contd.... (i) Radiator with blower fan including guard. (ii) Pipe coupling for engine cooling system piping. (iii) Corrossion in-hibitor coolant. (iv) Paper element filters for fuel, Lube oil, Bypass. (v) Fly wheel housing and flywheel. (vi) Engine bearing mechanism in flywheel housing. (vii) Flexible coupling. (viii) Dry type air cleaners. (ix) Residential silencer. (x) Stainless Steel exhust flexible bellows. (xi) Vaccum indicators. (xii) Electric starter. (xiii) 12/24V Battery of suitable AH Cap with Copper lead, Lugs and charging indicator. (xiv) Exhaust piping made out of heavy duty mild steel pipe 'C' class of length 3.5 metres above the building height (height of the building + 3.5 metre) or as per recommendations of OEM to meet CPCB-IV norms inclusive of all accessories and hardware, neccessary support steel structure stack including mineral wool insulation 2 inch thick suitable for 400 degree celcius temperature cladded with aluminium sheet for the entire length of exhaust pipe.
SER ITEM No. 4.00 Contd.... (xvii) First fill lube oil, coolant and diesel during commissioning & testing. (xviii) Silencer : Residential type, Fuel Hoses, Lubricating Oil Pump, Air Cleaner Dry type, Electronic Governor/ as recommended by OEM. (xix) Generator Monitoring Panel : comprising of standard items as per standard practice ignition switch start & stop arrangement, Indication for Engine parameters, Hrs run meter, rpm meter, Oil pressure indicator, water/ Coolant temp indicator, Battery Volt display ( State of the art Genset Controller). AMF Panel suitable for Outdoor installations with all required fixing and Safety arrangements. (xx) Safety Controls : Engine low Lub Oil Pressure, high water temp and over speeding of engine. (xxi) AVM Pads built or seperately mounted on manufacturer's base frame or as recommended by OEM. (xxii) Base frame : made out of ISMC of sturdy design made of MS channel with necessary reinforcement and predetermined holes. (xxiii) Fuel Tank : Daily service fuel tank ( as recommended by OEM) with calibrated level indicator, stop cock, drain plug, complete on a common base inside the acoustic enclosure, inbuilt tank having cap to store DHPP for 8-12 Hrs running on full load.
SER ITEM No. 4.00 Contd.... (xv) Exhaust gas driven turbo charger and Diesel Exhaust Fluid (DEF) tank of optimized capacity. (xvi) Fuel Injection eqpt with Electronic governor. (xxiv) Rubber mating of LV grade 19mm thick of suitable size chequred type ISI marked to be laid in front of control Panel shall be provided. (xxiv) Acoustic Enclosure shall be Powder Coated after pre-treatment Process, Outer body and door made of CRCA sheet of 1.6mm thick, base frame painted with epoxy based black shade sound insulation 100mm thick rockwool (64kg/cum), illuminated with suitable cap LED lamp fitting with switch complete as recommended by OEM suitable for above mentioned DG Cap. (xxv) NAL Approved as per CPCB-IV Norms. (xxvi) Batteries and Control Panel shall be inside the enclosure. (xxvi) External Emergency stop push button. (xxvii) The Noise level shall be 75dB max at 1 meter under free field condition. (xxviii) The quoted rate shall be deemed to be inclusive of 12 Hrs test run with required qty of Diesel at site including of half an hour on 10% overload in presence of representative detailed by Accepting Officer and all necessary arrangements are to be made by the contractor for test. Testing will be carried out till satisfication of Testing Officer. (xxix) Specification & Drawings for PCC foundation as recommended by OEM to be provided by the contractor within above quoted rates.
SER ITEM No. 4.00 Contd.... AMF Panel consisting of followings: xxi) Control Terminal Block 2.5/4sqmm-1 Set xxii) Control Wire-1/1.5/2.5Sqmm 5mtr approx each xxiii) Conical Insulator 50x10mm -1 Set xxiv) Gasket 25x3mm -1 Set xxv) Lugs, Ferrules (Control) 1.5/2.5sqmm -1 Set xxv) Lugs/ ferrules (1.5/2.5sqmm) -1 Set xxvi) Door Knobs with Open/ Close Sticker- 6 Nos xvii) PVC Channel, Din Rail Channel 45x45/25x45-1 Set xxviiii) Name Plate, Lables& Stickers-1 Set xxix) Eye Bolt-4 Nos xxx) bas bar sleeve-1 Set
M & L for Earthing complete with galvanised steel earth plate electrode of size 600x600x6mm thick as earth electrode with top edge of earth plate not less than 1.5 m below ground level using GI strip 25x 4mm as earth continuity conductor connected to earth plate by means of GI thimbles nuts bolts washers all as directed inculding providing earth wire protection pipe GI light grade 15mm dia from earth plate to pit level , watering pipe 20mm dia with mesh and funnel at top , earth pit and RCC pit cover in PCC 1:3:6 adequate quantity of characoal dust and salt all around the earth plate , earth work in any type of soil removal of surplus excavated material all as required at site and specified in EP no 3 of SSR part I- 2009 or directed by Engineer-in-Charge. [Note : 1) Test Report to be submit on completion. (2) if Permissible Earth Resistance Value not obtained then Re-Eathing will be done without any additional cost by the tenderer. (3) Extra Length of main earthing lead beyond 7.5 Mtrs will be measured and paid under respective item of this DCS.]
S&F Earth continuity conductor or main earthing lead of 25x4mm size galvanised iron strip fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing for DG Set Body and AMF Panel etc. as required
M & L for Earthing complete with galvanised steel earth plate electrode of size 600x600x6mm thick as earth electrode with top edge of earth plate not less than 1.5 m below ground level using GI strip 32x6mm as earth continuity conductor connected to earth plate by means of GI thimbles nuts bolts washers all as directed inculding providing earth wire protection pipe GI light grade 15mm dia from earth plate to pit level , watering pipe 20mm dia with mesh and funnel at top , earth pit and RCC pit cover in PCC 1:3:6 adequate quantity of characoal dust and salt all around the earth plate , earth work in any type of soil removal of surplus excavated material all as required at site and specified in EP no 3 of SSR part I- 2009 or directed by Engineer-in-Charge. [Note : (1) Test Report to be submit on completion. (2) if Permissible Earth Resistance Value not obtained then Re-Eathing will be done without any additional cost by the tenderer. (3) Extra Length of main earthing lead beyond 7.5 Mtrs will be measured and paid under respective item of this DCS.]
S&F Earth continuity conductor or main earthing lead of 32x6mm size galvanised iron strip fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing for DG Set Body and AMF Panel etc. as required complete all as specified and as directed.
Excavation in trenches n.exc 1.5m wide and n.exc 1.5m in depth for laying cables / poles foundation / stay assembly and getting out in hard / dense soil complete all as specified and as directed.
Returing filling in including spreading leveling watering and well ramming in layer not exceding 25 cm as in soil all as specified and directed.
Removing excavated material to a distance not exceding 50 m and depostingwhere directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and as directed.
Supply and laying in 160 x135 mm outer & inner dia, double walled corrugated (DWC) HDPE duct pipe confirming to IS-16205 Pt-24 with antirodent and non flame propogating properties of approval colour complete with fitting i.e.coupler,Tee,elbow clamp for cable protection of size 240/400sqmm complete all as specified and directed by Engr-in-charge.
Supply and laying in 63x50 mm outer & inner dia, double walled corrugated (DWC) HDPE duct pipe confirming to IS-16205 Pt-24 with antirodent and non flame propogating properties of approval colour complete with fitting i.e. coupler, Tee, elbow clamp for cable protection of size 25/35sqmm complete all as specified and directed by Engr-in-charge.
M&L for PVC UG Electric cable XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 400sqmm 3.5 core including Al thimbles on both end, any other monor fixing arrangement and taking down of old u/s existing cable of any size complete all as directed by Engr-in-Charge.
M&L for Electric cable XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 240sqmm 3.5 core including Al thimbles on both end, any other monor fixing arrangement and taking down of old unserviceable existing cable of any size complete all as directed by Engr-in-Charge.
M&L for Electric cable XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 35sqmm 3.5 core including Al thimbles on both end, any other monor fixing arrangement and taking down of old unserviceable existing cable of any size complete all as directed by Engr-in-Charge.
M&L for Electric cable XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 25sqmm 4 core including Al thimbles on both end, any other monor fixing arrangement and taking down of old u/s existing cable of any size complete all as directed by Engr-in-Charge.
Providing Services for shifting of Old BER DG Set of Cap 250/320 KVA from Power House/ Pump House to MES Store yard along with its connected accessories complete with the help of necessary tool and plant including crane services for lifting and transporting upto MES store yard complete all as directed.
Providing Services for shifting of Old BER DG Set of Cap 30/62.5KVA from Power House/ Pump House to MES Store yard along with its connected accessories complete with the help of necessary tool and plant including crane services for lifting and transporting upto MES store yard complete all as directed.
Electromech Engineers
RAVINDRA BROTHERS
N K BUILDERS
Vijaypower Generators Limited
BRITE INDUSTRIES
Rajan Traders
Prasur Electricals & Engineering Co.
Rama Electricals
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .