Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹5.0 LAccepted-Finance | L1 | Accepted-Finance L1 | |
| 2 | L2₹5.5 L+₹53,500 (10.8%)Rejected-Finance BHAGWATI NAGAR JAMMU | L2 | Rejected-Finance L2 | |
| 3 | Rejected-Technical B 5 HARBANS BHAWAN MR RAM AVTAR JOSHI NANGAL RAYA SOUTH WEST DELHI DELHI 110046 | NEW DELHI | DELHI | 110046 | - | Rejected-Technical Rejected |
Tender Value
₹5.5 L
Closing Date
22 Jul 2024, 3:00 pmClosed
Ex Engineer JSD PHE M Div South Jmu
Office of the Ex Engineer JSD PHE M Div South Jmu
Providing, Installation, Testing and Commissioning of Submersible Pumping unit of Capacity of 30,000 GPH X 130 mtr head along with allied works at T/well Fruit Mandi
2024_PHE_251061_1
PHEJ/MS/31 of 2024-25 Dated 24-06-2024
Open Tender
Machineries/ Mechanical Engg Items
Item Wise
20 days
Jammu
As per NIT
6 documents required · 6 mandatory
₹200
Ex Engineer JSD PHE M Div South Jmu
Exempted
Office of the Ex Engineer JSD PHE M Div South Jmu
18 Oct 2024
25 Jun 2024
23 Jul 2024
25 Jun 2024
22 Jul 2024
27 Jun 2024
26 Jun 2024
Amount
Providing, Installation, Testing and Commissioning of Submersible Pumping unit of Capacity of 30,000 GPH X 130 mtrs head along with allied works at T/well Fruit Mandi Narwal. The pump bowl should be of close grained cast iron with renewable wearing rings of bronze material. The pump shaft shall be of stainless steel guided with stainless steel distance sleeves /shaft protection sleeves provided with each bowl above and below the stainless steel impeller the casing wearing rings shall be of bronze material .The coupling shall be of mesh type rigid sleeve of stainless steel ,non slipping type with matching groove and cotter arrangement to suite keyway provided .The suction case shall be of close grained cast iron material .The motor should be three phase AC supply having nominal speed of 2900 RPM, 380 Volts + 15% of frequency 50 Hz + 3%. The motor should be totally enclosed squirrel cage induction type, water cooled and sealed against outside water being pumped. The windings shall be wet type water lubricated and provided with metal tilting thrust pad designed to take up all untoward load to most unfavorable running conditions. The Acceptable Make Kirlosker/ KSB / Grundfos. The job further includes Fabrication of adapter Nipple approx 1 mtr long fabricated out of MS Pipe, of which bottom end diameter is to be reduced to the delivery of Sub. Pump and threading the Pipe for screwing into the delivery portion to the submersible pump and other end of the adapter nipple is welded with MS flange of required size fabricated out of MS Plate for fixing with the column pipe.2 No nuts of required size are to be welded on opposite size of the proper piece so that clamping bolt of the tie rod can passed through it. The Job includes the cost of material and labour charges .Fabrication of the tie rod clamping arrangement for clamping the pump and motor to the upper adopter nipple, fabricated out of 40x6 MS Plate as per required size. The upper ends of these flat strips should be welded with full threaded bolt 12mm dia and 10 cm long. These bolts are to be passed through the nuts welded on the adopter nipple piece, tightening of the 12 mm double nuts on both sides including cost of material and labour charges. Fabrication of 150 mm dia MS forged clamp 2 No’s for lowering the MS column pipes into the Tube well casing pipe. The clamp should be in the two halves and should have two holes on either side of the holding arm. The clamp has to be fabricated out of MS Flat of 100 mmx10 mmx 0.75 mtr. The Job includes the cost of MS flat for clamp 4 No’s with cost of material and labour etc. The Job includes coupling of pump and motor properly checking of movement of the pump, tightening of the adopter nipple to the delivery side of the pump tightening of tie rod and testing of the pump set in the testing pit at workshop. Lowering of submersible pump set into the Tube well along with the column pipes of 150 mm dia by using special tools and tackles viz chain pulley block, MS Clamp. The job also providing and fitting 150 mm dia M S Column Pipe 03 nos. of 3 mtrs. each in length duly flanged on both ends. The Job includes the cost of M S pipe 150 mm dia, rubber gasket, nuts bolts and cost of MS flanges, sub pump set and labour charges. Providing, Fitting and commissioning of 200 mtrs. 35 sq.mm Sub cable 3 core make Havel’s/ Finolex / Anchor / Polycab, one of cable end will be fixed in panel and other end with sub motor after properly dressing of cable ends and insulating their properly. The Job also includes enlargement of existing grooves (25mm Sq. Sub Cable) of 150mm dia MS Pipe for 35 sq.mm submersible cable. The Job includes patching of the cable existing sub. cable of motor by using patch rolls and insulation tape to make water proof for lowering of sub, pump unit. Testing of submersible pump set on full load by making connections of 35 sq.mm submersible cable of motor pump set with the panel and checking/high testing of all the electro mechanical connections. The Job also includes replacement of Components of 200 Amp. LT Control Panel by way of providing, fitting MNX 225 – 01 no., MNX 185 - 01 no., MNX 150 - 01 No., and replacement of 400 Amp., Main Switch by new one. The Job also includes replacement of 800 Amp., MCCB (L&T/ Schneider/ Havels ) of 250 KVA Voltage Stabilizer. The complete job includes cost of material, labor and charges of mechanical transport including testing of the pump set on full load and handling charges including lowering charges. Complete Job in all respect. Complete Job.
PERFECT ELECTRICAL WORKS
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .