Executive Engineer (E)
O/o EE (E), HPED, PWD, Yamuna Western Bank, Lok Nayak Setu, ITO, New Delhi-02
Comprehensive Maintenance and RMO of various E and M services installed at LBSH, Khichripur Delhi SH Operation and Maintenance of EI Pumps Fire Alarm System, Fire Fighting System CCTV EPABX STP RO Plant and RO System Mixed Oxidant Plant and various o
2026_PWD_300135_1
05/SE(E)/HEC-II/PWD/2026-27
Open Tender
Electrical Works
Percentage
730 days
Lal Bahadur Shastri Hospital
Please refer Tender documents.
2 documents required · 2 mandatory
₹0
₹18.8 L
Yes
O/o SE(E) HEC-II, 5th Floor MSO Building, New Delh
16 Oct 2026
16 Oct 2026
23 Oct 2026
16 Oct 2026
23 Oct 2026
16 Oct 2026
19 Oct 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | SH-1: Operation and Maintenance of E.I, Pumps, Fire Alarm System, Fire Fighting System, CCTV, EPABX, STP, RO Plant and RO System, Mixed Oxidant Plant and various other services installeld at Lal Bahadur Shastri Hospital.
SH-A (Water Cooler & Water Testing ):
SITC of 150 Liters/Hr cooling capacity with inbuilt 150 Liters Per Hour RO Purification System with auto sanitization with min.7 stage purifications & storage capacity of 150 LTR :
Cooling Water Storage Capacity. : 150 Ltr
Water Cooling Rate 150 LPH
Water Inlet Cooling Adjustment Temperature: 13.5 °C Adjustable
No. Of Faucets : 2 COLD
Water Recovery: More than 70%
Outer Body Material- Tank/Cooler: SS204 cu
Storage Tank/Cooler Material : SS304 food grade or better
Refrigerant : R-134 A or equivalent
Operating Voltage :230+-10% V AC,50 Hz
Power Consumption: Max. 1.7 KW
RO Purification System
Type of water purification technology: RO + EPS/ESS
Purification Capacity. : Min.150 Liters/Hour
Purification Stages : Min Seven stage filtration process
Sediment Filter: Dedicated 10 micron 20" filter
Carbon Filter: Activated Carbon Block- 10 micron 20" filter
Water Saver Cartridge: 20” Nova Cartridge
Taste Enhancer Cartridges: PH Correction Cartridge
RO Membrane: 300X 3 + 100X 1 GPD
Taste Enhancer cartridge: PH correction cartridges
Auto Sanitzer – Storage tank : ESS – protect tank water from bacterial growth
Purification Stages : Min 7 stage filtration process with required Technology. | 26 | Nos | 2,62,259 | ₹68,18,734 |
| 2 | Water testing after collection of water samples from the site directly by the NABL accredited lab or any Govt. authorized lab complete with the following tests conforming to IS : 10500 2012 for drinking water complete as reqd:-
(A) Chemical Test
1). Colour, Hazen Unit
2). Output
3). Taste
4). Turbidity, NTU
5). pH Value6). Total Hardness (as CaCO3) mg/l
7). Iron (as Fe), mg/l
8). Chlorides (as Cl), mg/l
9). Total Dissolved Solid, mg/l
10. Fluoride (as F), mg/l
(B). Bacteriological Test
1). E.Coli or thermotolerant Coliform bacteria
2). Total Coliform bacteria | 16 | Job | 1,150 | ₹18,400 |
| 3 | SH-B Bio-Enzymatic culture
Supply and Dosing of Bio-Enzymatic culture for Biological treatment available in powder from a special waste treating microbes along with enzymes. Bio-Enzymatic solution of aerobic and anaerobic bacteria count of each not less than 8x10^9 CFU/mg (Brands : EnSafe or equivalent) | 200 | kg | 6,293 | ₹12,58,600 |
| 4 | SH- C STAC/WTAC Work
Complete servicing of WTAC/STAC unit of 1.5 / 2.0 Tr capacity including dismantling the AC from its existing position i.e. various OPD's, Wards, ICU, OTs and various DA Dispensaries/Polyclinics etc, cleaning of evaporative and condensing coil with suitable chemical like coil cleaner, greasing of motor, cleaning of drain pipe and refixing the same on its existing position complete etc. as required. (For Two Years) | 400 | Nos. | 556 | ₹2,22,400 |
| 5 | Supplying & Charging of R-410a/R-22/R-32 refrigerant gas in existing following capacity WTAC / STAC unit i/c replacement of capillary tube & strainer, pressure testing, vaccumising, testing etc. complete as reqd. (For Two years)
(A) 1.5 TR capacity | 150 | Nos. | 2,196 | ₹3,29,400 |
| 6 | (B) 2 TR capacity | 80 | Nos. | 2,507 | ₹2,00,560 |
| 7 | Supplying & replacement of following capacity reciprocating/rotary type hermetically sealed compressor complete in the existing WTAC & STAC unit i/c repairing / rejoining of copper pipes, testing etc. as reqd.
(A) 1.5 TR capacity | 50 | Nos. | 9,730 | ₹4,86,500 |
| 8 | (B) 2 TR capacity | 25 | Nos. | 10,736 | ₹2,68,400 |
| 9 | Supplying, Installation, testing and commissioning of following capacity condenser coil in the existing WT /Split type AC i/c breezing the copper piping and fitting with screws, pressure testing & gas charging etc. as required at site.
(A) 1.0/1.5 TR Condenser coil | 20 | Nos | 5,312 | ₹1,06,240 |
| 10 | (B) 2.0 TR Condenser coil | 15 | Nos | 7,270 | ₹1,09,050 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 12.42 MB
BOQ_400559.xls
BOQ • 0.59 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .