| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹3.3 LAccepted-AOC HPSEBL THALOUT | KANGRA | HIMACHAL PRADESH | 176201 | L-1 | Accepted-AOC awarded to lowest bidder | |
| 2 | L-2₹3.4 L+₹11,303.92 (3.39%)Rejected-Finance | L-2 | Rejected-Finance Higher Amount | |
| 3 | L-3₹3.4 L+₹11,504.60 (3.45%)Rejected-Finance BLOCK A 16 SET NO 11 SDA COLONY VIKAS NAGAR SHIMLA 9 H P | L-3 | Rejected-Finance Higher Amount | |
| 4 | L-4₹4.0 L+₹65,501.84 (19.7%)Rejected-Finance VILLAGE AND POST OFFICE JEORI TEHSIL RAMPUR DISTT SHIMLA H P | JEORI | SHIMLA | HIMACHAL PRADESH | L-4 | Rejected-Finance Higher Amount |
Tender Value
₹4.4 L
EMD Value
₹8,885
Closing Date
30 Jun 2025, 11:00 amClosed
Executive Engineer
Executive Engineer Jal Shakti Division Nalagarh District Solan HP
Sub Head Providing laying jointing testing of RCC pipe 600 mm dia and Construction of outlet chamber Under DMFT
2025_HPIPH_108402_1
3062-98 dated 21-06-2025
Open Tender
Civil Works
Item Rate
30 days
Nalagarh
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
Yes
₹8,885
24 Jul 2025
23 Jun 2025
30 Jun 2025
23 Jun 2025
30 Jun 2025
23 Jun 2025
Amount
Excavation in foundation & trenches etc. in in earth work lift up to 1.5 meter stacking the excavated soil not more than 3 meters clear from the edge of excavaton and then returning the stacked soil in 15cm layers when required into plinths, side of foundation etc. Consolidating each deposited layers by remming and watering and then disposing of all surplus excavated earth as direction within a lead of 20 mtr in pick work.
Prov.and lying cement concrete 1:3:6 (1Cement: 3Sand: 6 approved quarry stone agg.40mm nominal size)& curing complete excluding cost of form work and reinforcement for reinforced cement concrete work in suspended floors, roofs etc. i/c entire carriage of materials with in all leads and lifts
Providing and laying cement concrete 1:1/2:3 (1 cement :1/2app. sand :3 app. quary graded stone agg. 20mm nominal size) and curing complete excluding cost of form work and reinforcement for reinforced cement concrete work i/c entire carriage of materials with in all leads and lifts
Foundation, footing, bases of columns and the like & mass concrete.
In walls (any thickness butt not less than 0.10m thickness) atteched pillasters,buttresses plinth & string courses etc. From top of centring & shuttering in foundation & plinth.
Providing from work with steel plates 3.15 mm thic welded with angle iron in frame 30x30x5 mm so as to give a fair finish i/c centring, shuttering, strutting and proping etc with wooden battens and ballies. Height of proping and centring below suporting floor to ceiling not exceeding 4 mtrs and removal of the same for insitu -reinforced concrete and plain concrete work in flat surfaces such as soffits of suspended floors, roofs, landing and the like floor etc. up to 200 mm in thickness i/c carriage of material within all leads and lifts complete in all respect.
Vertical surfaces such as wall (any thickness) partitions and the like including attached pillasters, buttresses plinth and string courses and the like.
In flat surfaces with steel plates such as soffits of suspended floors, roofs, landings and the like floor etc upto all thickness in all thickness.
providing and laying Cement concrete work 1:2:4 (1 cement :2 sand :4 water borne aggregate 20mm nominal size) and curing complete excluding the cost of form work and reinforcement for reinforced concrete work in suspended floors, roofs, landing shelve and their supports balconies beams, girders bressumers and centilevers upto floor two level.
Providing laying of tor steel reinfrcement for RCC work i/c bending, binding and placing in positon complete up to floor two level.
Providing & fixing Man hole cover (size 680x680) with MS sheet 2.00 mmthick with hinges on MS angle iron frame 35x35x3 mm supporting duly welded and fixed in RCC slab with anchoir bolt 12mmx150mm i/c cost of welding charges,carriage, fixing and applying priming coat locking arrangement complete in all respect as per entire satisfaction of engineer in charge.
Providing, laying,jointing and testing (to level of slop) and unrainforced concrete non pressor pipes IS class NP-2 of 600 mm dia with socket and spigot ends including testing of joints complete.
Jashwant Singh (BID ID -529617)
VIVEK SHARMA (BID ID -530045)
NARAYAN SINGH (BID ID -530032)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .