Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
| 3 | Admitted-Finance 1A BASEMENT 30 31 RAJA HOUSE NEHERU PLACE NEW DELHI | NEW DELHI | NEW DELHI | DELHI | Admitted-Finance |
| 4 | Admitted-Finance 1476 SARASWATI COLONY CHERITAL JABALPUR | JABALPUR | MADHYA PRADESH | 482001 | Admitted-Finance |
| 5 | Admitted-Finance 1257 SCHEME NO 5 NEAR HB COLLEGE VIJAY NAGAR JABALPUR MP PIN 482002 | JABALPUR | MADHYA PRADESH | 482002 | Admitted-Finance |
Tender Value
₹9.5 L
EMD Value
₹19,000
Closing Date
2 May 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE JABALPUR
HQ CWE JABALPUR OPPOSITE SUPPLY DEPOT SADAR JABALPUR 482001
PROVISION OF 63 KVA GEN SET (SILENT TYPE) FOR 1 WTS, 10 MTR AIR RIFLE AND PISTOL RANGE, IT AND OFFICERS OF 1 MTR , 1STC JABALPUR UNDER GE (WEST) JABALPUR
2024_MES_649435_1
81003/E8
Open Tender
Miscellaneous Works
Item Rate
180 days
JABALPUR
AS PER NIT
7 documents required · 7 mandatory
₹500
Yes
GE WEST JABALPUR
₹19,000
Yes
7 May 2024
6 Apr 2024
4 May 2024
6 Apr 2024
2 May 2024
20 Apr 2024
6 Apr 2024 - 19 Apr 2024
Amount
Supply, installation, testing and commissioning static silent (Sound proof enclosure) Diesel Engine Driven Generating set capable of delivering 46.8 KW (58.5 KVA output), at prime mover rating at 0.85 load factor as per ISO-8528 (Part-I), 415 Volts (AC three phase, 4 Wire system of supply) 50 Hz at 0.80 minimum power factor. The DG set shall consist of diesel engine coupled to a matching alternator, through flexible coupling and mounted on common base frame and complete with AMF control panel standardized by Manufacturer, fuel tank with mounting arrangements and inlet, outlet return inlet oil arrangement, exhaust pipe including all mounting accessories as required/ suitable for installation at 1MTR,1STC Jabalpur (MP) complete including, anti vibration pads, including all features to comply with latest CPCB IV + emission compliant norms/guidelines and comprising of the followings: Note:-Capacity of engine, alternators shall be worked out after taking all derating factors into consideration.
(a) ENGINE (prime mover): Diesel engine 1500 RPM, direct injection, 3 cylinders, in line with Mechanical governer, engine, well designed air handling system with dry type, replaceable paper element air cleaner with restriction inductor, air to air after cooling, optimised turbocharger for increased altitude capabilities, best in class fuel economy with bosh HPCR fuel system with A1 class electronic governing, duel fuel filter system, pre filter including water separator and water in fuel (WIF) sensor and main filter, Electrical lift pump for faster response, standrd intergral set mounted radiator system, designed and tested for 50°C temp, hospital grade silencer suitably optimised to meet stringent noise emission standards laid down by MOEF/CPCB, complete exhaust pipe with clading as per site requirement, comforming to ISO 3046/BS5514, to drive alternator capable of delivering 50KW (58.5 KVA) at outdoor atmoshpheric conditions at 1MTR 1STC Jabalpur (MP), 12V (as per manufactuerer's recommendations) eletric battery start, complete with dynamic balanced fly wheel, all standard fittings/fixtures as per Manufacturer's technical instructions, with and including suitable panel with techometer, lub oil temp, pressure gauze and Freqequency meter and also incld self starter system , dynamo, fuel electric control panel with electronic governor (ECPG) and engine protection systems ( shut down, high water tempature, low lub oil, oil pressure, over speed etc) fuel tank and first fill of lub oil and other comsumables items etc cmplt
(b) Alternator: Brushless AC alternator, 3 phase 415 Volts, 4 wire rated for output of 58.5 KVA 46.8 kW, minimumn power factor 0.8, 1500 RPM, IP23 protection class enclosure, insulation class "H", salient pole, revolving field, single bearing automatic voltage regulator coupled through flexible coupling with and to match with the engine as specified above.
(c) BASE PLATE: Made of structural steel as per Manufacturer's |recommended design/specifications complete.
(d) Accoustic Enclosure : Sheet metal fabricated cope type, powder coated silent enclosure manufactured on CNC machines as per letest CPCB norms complete. (Note: Enclosure shall be designed for reducing the sound level as under with following conditions as laid down in GSR No. 371 (E) dt 15 Aug 2008: (i) 75 DB at a distance of 1.0M at 75% load under field condition. (ii) 70 DB at 3.0M from Gen set when DG set is working at full load along with testing conformance, labelling certificaton, etc)
(f) Foundation/Plinth/Base: PCC platform of size extended 0.50M all round of DG set (outer dimensions), 0.60M above GL and 0.30M below GL in PCC 1:2:4 type B2 using 40mm graded stone aggregate, foundation 150mm thick and 150mm extending on all sides of PCC platform in PCC 1:4:8 type D2 using 40mm graded stone aggregate including necessary excavation & earth work, formwork and plaster/ rendering in CM (1:4) on all sides of PCC platform upto 15cm below from GL and two coats of white wash on plastered surfaces including prepration of surfaces complete all as directed.
(g) Diesel storage tank - capacity adequate for storage of diesel for 12 hours operation of Gen set in addition to one No of capacity 200 Ltr Steel/GI Tank of make as approved by GE
(h) Miscellaneous: Tool kit, operation and maintenance catalogue, spare parts list, overhauling manuals, guarantee card including genuiness certificate from Manufacturer etc shall be provided as per Manufacturer's standard practices as and when asked.
General Notes for item No. 1.00: (i) The DG set shall be taken over only after it has been tested as per relevant IS specification/instructions by the contractor in the presence of an officer nominated by the Accepting Officer and signed copy of testing sheet should be provided by contractor as per MES procedure only after which completion will be given. (ii) All the expenses incurred on the above test including provision of testing apparatus,fuel required to carry out the above mentioned test shall be borne by the contractor without any extra cost to the Government. If the result of the test is not found satisfactory, the contractor shall at his own expenses, replace the defective equipments/ materials/ accessories or any part thereof as directed by the GE. Decision of Accepting Officer shall be final, conclusive and binding in this respect.
M&L for earthing with galvanized steel earth plate electrode 600x600x6.0mm thick directly burried in the ground (earth pit not less than 2.25M deep below ground level) with top edge of earth plate not less than 1.50M deep below normal ground level, connected to galvanised iron strip 32x6mm by means of bolts, nuts, check nuts and washers of galvanised iron or steel, 40mm bore GI pipe medium grade including necessary fittings for protection of earthing strip, watering pipe 20mm bore GI medium grade, concrete chamber in PCC (1:4:8) type D-2 using 40 mm grade aggregate, coping shall be in PCC (1:3:6) type C-1 using 20 mm grade aggregate and internal surfaces of concrete chamber shall be given 12mm thick plaster in CM (1:4), funnel with wire gauge of 22 gauge (0.63 mm) 8 mesh per linear incl 50mm thick cover of RCC (1:2:4) type B-1 using 20mm grade stone aggregate reinforced with 8mm MS deformed bar @ 75 mm C/C both ways, char coal dust and common salt all as shown in electrical plate No. 3 of SSR Part-I (2009) including all necessary excavation & earth work and removal of surplus soil to a distance n. exc 50M and providing connection points with MS/ GI bolts & washers as required and connection from earth test point to earth electrode with same GI earth strip alongwith protection pipe and testing on completion complete all as specified and directed. Note:- GI strip and protection pipe from earth electrode to test point max upto 7.50M shall be deemed to be included in the unit rates as quoted by the contractor
Supply and spreading clean and dry fine sand free from sharp materials (unwashed) laying in trenches around the cable for cushioning in trenches, laid to a uniform thickness of 23cm (15cm under the cable & 8cm over the cable) and gently punned down to 18cm thickness complete all as specified and as directed. (Note : Punned thickness shall be considered for the payment purpose.)
S&F On load Manaul change over switch 415V in sheet metal enclosure 4 pole of capacity 200 Amps complete all as specified and as directed. .
Excavating in trenches, not exceeding 1.5m wide and not exceeding 1.5m in depth for laying of pipe, cable etc or n. exc.10 Sqm on plan and n. exc. 1.5m in depth and getting out in any type of soil complete all as specified and directed.
Returning, filling in excavated approved soil, including spreading, levelling, watering and well ramming in layers not exceeding 25cm each complete all as specified and directed.
Removing excavated soil not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and directed.
Supply and laying Sub Class 'B' old size bricks laid in trenches as cable cover with witdth equal to the length of brick complete all as specified and as directed.
Supplying and fixing/ laying of 50 mm bore dia GI pipe medium grade in trenches/ under roads/ along pole/ wall including all necessary fittings & clamps made out of 25x3mm flat iron as required for cable protection etc complete all as specified and directed.
Supplying and laying synthetic Rubber insulated mats 2 mm thick for voltage upto 3.3 kv for electrical purpose as per IS 15652-2006, (superseding IS 5424) suitable for electrical shock safety of sizes 2m x 1m complete all as specified and directed.
Supply and fix Galvanised iron strip 32x 6mm with and including saddles and fixing screws etc and jointing of strips with suitable size of nuts, bolts & washers; for roof conductors and down conductors above ground complete all as specified and directed.
Supply, laying or fixing or passing through pipe, commissioning and testing XLPE Insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 70 Sqmm 3.5 core complete all asspecified & directed. (Note : Excavation and earthwork, sand cushioning and cable protection shall be measured and paid for separately.)
CUTCH CONSTRUCTION
Sachdeva Enterprises
MONA GENERATOR SEVICES PVT. LTD.
MAYANK CONSTRUCTIONS
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .