Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹20.8 LAccepted-AOC | L1 | Accepted-AOC Being lowest | |
| 2 | L2₹26.9 L+₹4.0 L (17.5%)Rejected-Finance | L2 | Rejected-Finance Being other than lowest | |
| 3 | L3₹30.4 L+₹7.5 L (32.6%)Rejected-Finance | L3 | Rejected-Finance Being other than lowest |
Tender Value
₹39 L
EMD Value
₹78,000
Closing Date
7 Sept 2020, 6:00 pmClosed
GE (AF) E/M CHAKERI KANPUR
GE (AF) E/M CHAKERI KANPUR 208008
REWIRING OF OLD UNSERVICEABLE DETERIOTED WIRING ON TECH AREA AT AFS CHAKERI KANPUR
2020_MES_360023_2
8411/E8
Open Tender
Civil Works
Item Rate
274 days
GE (AF) E/M CHAKERI KANPUR
As per NIT
8 documents required · 8 mandatory
₹500
GE (AF) E/M CHAKERI
₹78,000
14 Oct 2020
17 Aug 2020
12 Sept 2020
17 Aug 2020
7 Sept 2020
24 Aug 2020
Amount
Taking down old unserviceable/deteriorated batten/PVC conduit /MS conduit point wiring from existing place i.e. light, fan, socket or power points complete with all unserviceable fittings such as switches, sockets, ceiling rose, pendants, Holders, etc and making good all disturbed surface to wall, floor etc by means of cement mortar (1 : 3) or plaster of Peris and to match / finish new surface as the existing surface either by using same colour distemper, Putti or white / colour wash complete all as specified and directed.
Taking down main switch/DB/ changeover/AC box of any capacity including fixing accessories complete all as specified and directed.
M & L surface point wiring on coulum and truss and on wall with necessary fixing arrangements with multi strand PVC-FRLS insulated and unsheathed copper multi strand conductor of size 1.5 Sqmm, 1100 volts grade drawn in and including 16 gauge stove enameled rigid steel conduit (metallic) not less than 19 mm dia with all conduit accessories/ fittings such as junction boxes, bends, tee, elbow etc including anodized MS sunken boxes made out of MS sheet of thickness not less than 1.6 mm with earth dolly and Bakelite laminated sheet 3mm thick ISI marked for fixing of switches / sockets, fan regulators. door bell, wal bracket/bulkhead etc with brass screw and cup washers including PVC-FRLS insulated and unsheathed copper multi strand conductor of size 1.5 Sqmm, 1100 volts grade for continuous earthing including cutting the chases and complete all as specified and directed for the one light, fan, call bell, point controlled by one switch.:- Make of wire : Polycab /havells/Finolex and make of conduit: Plaza/Kalinga/AKG Note:- All points to be made in Hangers only.
All as per item No. 3 but For one socket point controlled by one switch on same board
All as per item No. 3 but For one 5Amp independent socket point controlled by one switch.
All as per item No 3 here-in-before but for power point wiring with 2.5 Sqmm PVC-FRLS insulated, unsheathed, copper conductor, multi strand 1100 volt grade cable and 1.5 Sqmm PVC-FRLS insulated, unsheathed, copper conductor, multi strand 1100 volt grade cable as continuous earth lead.
M & L surface point wiring on ceiling/roof and concealed point wiring on wall with necessary fixing arrangements with stranded PVC-FRLS insulated and unsheathed copper stranded conductor of size 1.5 Sqmm, 1100 volts grade drawn in and including 16 gauge stove enameled rigid steel conduit (metallic) not less than 19 mm dia with all conduit accessories/ fittings such as junction boxes, bends, tee, elbow etc including anodized MS sunken boxes made out of MS sheet of thickness not less than 1.6 mm with earth dolly and Bakelite laminated sheet 3mm thick ISI marked for fixing of switches / sockets, fan regulators with brass screw and cup washers including PVC-FRLS insulated and unsheathed copper stranded conductor of size 1.5 Sqmm, 1100 volts grade for continuous earthing including cutting the chases and making good the surface by cement mortar (1:3) and for matching / finishing of new surfaces either by means of plaster of peris/ Putti or distemper / colour wash with same existing colour surfaces complete all as specified and directed for the one light, fan, call bell contolled by one switch . Make of wire : Polycab /havells/Finolex and make of conduit: Plaza/Kanlinga/AKG. Note : All points will be made in other than Hangers
All as per item No. 7 but for one socket point controlled by one switch on Independent board
All as per item No. 7 but For one socket point controlled by one switch on same board
All as per item No 7 here-in-before but for power point wiring with 2.5 Sqmm PVC-FR insulated, unsheathed, copper conductor, stranded 1100 volt grade cable and 1.5 Sqmm PVC-FR insulated, unsheathed, copper conductor, stranded 1100 volt grade cable as continuous earth lead.
M & L for concealed/surface point wiring on wall and ceiling/roof with necessary fixing arrangements with PVC-FRLS insulated and unsheathed copper multi-stranded conductor of size 1.5 Sqmm, 1100 volts grade drawn in and including rigid non metallic white / ivory PVC conduit medium grade ISI marked not less than 19 mm dia with all conduit accessories/ fittings such as junction boxes, bends, tee, elbow etc including anodized MS sunken boxes made out of MS sheet of thickness not less than 1.6 mm with earth dolly and Bakelite laminated sheet 3mm thick ISI marked for fixing of switches / sockets, fan regulators, wall mounting fittings, door bell & bulkhead etc with MS screw and cup washers including PVC-FRLS insulated and unsheathed copper multi-stranded conductor of size 1.5 Sqmm, 1100 volts grade for continuous earthing including cutting the chases and making good the surface by cement mortar (1:3) and for matching / finishing of new surfaces either by means of plaster of peris/ Putti or distemper / colour wash with same existing colour surfaces complete all as specified and directed for the following:- Make of wire : Polycab/Havells/Finolex,Make of Conduit: Plaza/Kalinga/AKG For one light, fan, call bell, point controlled by one switch.
All as per item No 11 here-in-before but For one socket point controlled by one switch on same board
All as per item No 11 here-in-before but 5Amp independent socket point controlled by one switch.
All as per item No 11here-in-before but for power point wiring with 2.5 Sqmm PVC-FRLS insulated, unsheathed, copper conductor, stranded 1100 volt grade cable and 1.5 Sqmm PVC-FRLS insulated, unsheathed, copper conductor, stranded 1100 volt grade cable as continuous earth lead.
M & L for switch flush type single pole one way 5 Amps, 240 volts, white finish complete all as specified and directed Make : CONA/Anchor/Havells
M & L for switch flush type 15 Amps, 240 Volts single pole white finish complete all as specified and directed Make : CONA/Anchor/Havells
M&L for socket outlet 5 pin, 5 Amps flush type white finish complete all as specified and directed Make : CONA/Anchor/Havells
S&F socket outlet 2 in 1, 3 pin, 5/15 A, flush type universal, 240 V white finish complete all as specified and directed Make : CONA/Anchor/Havells
S&F electronic socket size, rotary, 5 speed step type regulator, 120-230 V white finish complete all as specified and directed Make : CONA/Anchor/Havells
S&F ceiling rose, surface backlite, 65 x 20 mm three terminal complete all as specified and directed. Make : CONA/Anchor/Havells
S&F, in repair, lamp holder insulated body with back plate suitable for angle / batten fitting conforming/ ISI Marked complete all as specified and directed. Make : CONA/Anchor/Havells
S&F in repair double door metallic sheet metal enclosure having IP43-IK09 for DB when MCBs to be used SPN 8 ways, 240 V with 200Amps rated bus bar complete fixed properly on in concealed position on wall and suface position on trusses and to provide required sizes of flexible conduit at any open surfaces near DBs of cables/wires including providing of suitable size of lugs and blanking plate complete all as specified and directed Make: Legrand/Scheinder/L&T
All as per item No 22 here-in-before but 4 way -do-
S&F in repair double door metallic sheet metal enclosure for DB when MCBs to be used TPNL, 4 ways, 415Volts (horizontal type) with 200 Amps rated bus bar suitable for TPN MCB/ 4 pole Isolator fixed properly on in concealed position on wall and surface position on trusses and to provide required sizes of flexible conduit at any open surfaces near DBs for cables/wires complete all as specified and directed Make: Legrand/Scheinder/L&T
S&F in repair sheet metal enclosure double door type for DB when MCBs & MCCB 125 Amp (as incomer) & MCB SP/TP (as outgoing) to be used, VTPN, 4 ways, 415 V with bus bar fixed properly on in concealed position and to provide required sizes of flexible conduit at any open surfaces near DBs of cables/wires complete all as specified and directed Make Legrand/Scheinder/L&T
S&F in repair testing and commissioning of MCB SP 240 volt 6 Amp to 32 amp 10 KA capacity having C-curve characteristics connected with suitable lugs complete all as specified and directed. Make Legrand/Scheinder/L&T
All as per item No 26 here-in-before but SP 40-63 Amps -do-
All as per item No 26 here-in-before but SPN 16-32 Amps -do-
All as per item No 26 here-in-before but SPN 40-63 Amps -do-
All as per item No 26 here-in-before but TP 40-63 Amps, 415V -do-
All as per item No 26 here-in-before but TPN 40-63 Amps, 415V -do-
S&F in repair MCCB 125 Amps, 4 Pole, 415V, 25KA complete all as specified and directed Make: Legrand/Scheinder/L&T
S&F in repair MCCB 160 Amps, 4 Pole, 415V, 36KA complete all as specified and directed Make: Legrand/Scheinder/L&T
S&F in repair MCCB 250 Amps, 4 Pole, 415V, 36KA complete all as specified and directed Make: Legrand/Scheinder/L&T
S&F in repair sheet metal enclosure , 32A, 230 Volts single pole and neutral with a two pin and earth plug and socket complete in metal clad board (Industrial type) with one single pole MCB 32 Amp fixed properly on / in concealed position on wall and surface position on trusses complete all as specified and directed Make:Legrand/Scheinder/L&T
S&F in repair sheet metal enclosure , 32A, 415 Volts triple pole neutral & earth with a three pin and earth plug and socket complete in metal clad board (Industrial type) with one TP MCB 32 Amp fixed properly on / in concealed position complete all as specified and directed. Make: Legrand/Scheinder/L&T
S&F in repair sheet metal enclosure , 63A, 415 Volts triple pole neutral & earth with a three pin and earth plug and socket complete in metal clad board (Industrial type) with one TPN MCB 63 Amp fixed properly on / in concealed position complete all as specified and directed. Make: Legrand/Scheinder/L&T
M&L sub main wiring on surface with two single core PVC-FRLS insulated unsheathed multi stranded copper conductor cable of size 4 sqmm drawn in MS/PVC conduit with 2.5 Sqmm PVC-FRLS insulated unsheathed multi stranded copper conductor as a continuous earth wire complete excluding rigid stove enameled steel conduit ISI marked of size not less than 25 mm dia in concealed/surface wiring inclusive all fitting such as tee, bends, reducer, elbow, bell mouth, tube ends and all fixing accessories such as couplers lock, nuts, sadles, pipe hooks etc fixed properly including taking down old unserviceable sub main wiring complete all as specified and directed. Make of wire: Polycab/Havells/Gloster/Finolex. Note : M S Conduit/ PVC Conduit and cutting cheaseling and making good will be measured and paid separately
M&L sub main wiring on surface with two single core PVC-FRLS insulated unsheathed multi stranded copper conductor cable of size 6 sqmm drawn in MS/PVC conduit with 4 Sqmm PVC-FRLS insulated unsheathed multi stranded copper conductor as a continuous earth wire complete excluding rigid stove enameled steel conduit ISI marked of size not less than 32 mm dia in concealed/surface wiring inclusive all fitting such as tee, bends, reducer, elbow, bell mouth, tube ends and all fixing accessories such as couplers lock, nuts, sadles, pipe hooks etc fixed properly including taking down old unserviceable sub main wiring complete all as specified and directed Make of wire: Polycab/Havells /Finolex. Note : M S Conduit/ PVC Conduit and cutting cheaseling and making good will be measured and paid separately
M&L sub main wiring with four single core PVC-FRLS insulated unsheathed multi stranded copper conductor cable of size 6 sqmm drawn in MS/PVC conduit with 2 run of 4 Sqmm PVC-FRLS insulated unsheathed multi stranded copper conductor as a continuous earth wire complete excluding rigid stove enameled steel conduit ISI marked of size not less than 25 mm dia in concealed/surface wiring inclusive all fitting such as tee, bends, reducer, elbow, bell mouth, tube ends and all fixing accessories such as couplers lock, nuts, sadles, pipe hooks etc fixed properly including taking down old unserviceable sub main wiring complete all as specified and directed Note : M S Conduit/ PVC Conduit and cutting cheaseling and making good will be measured and paid separately. Make of wire: Polycab/Havells /Finolex
M&L sub main wiring on surface with four single core PVC-FRLS insulated unsheathed multi stranded copper conductor cable of size 10 sqmm drawn in MS/PVC conduit with 2 run of 6 Sqmm PVC-FRLS insulated unsheathed multi stranded copper conductor as a continuous earth wire complete excluding rigid stove enameled steel conduit ISI marked of size not less than 32 mm dia in concealed/surface wiring inclusive all fitting such as tee, bends, reducer, elbow, bell mouth, tube ends and all fixing accessories such as couplers lock, nuts, sadles, pipe hooks etc fixed properly including taking down old unserviceable sub main wiring complete all as specified and directed Make of wire: Polycab/Havells /Finolex Note : M S Conduit / PVC Conduit and cutting cheaseling and making good will be measured and paid separately
S&F rigid metallic medium 20mm dia stove enameled steel conduit ISI marked in concealed position inclusive all fitting such as tee, bends, reducer, elbow, bell mouth, tube ends and all fixing accessories such as couplers lock, nuts, saddlers, pipe hooks etc fixed properly on as in concealed position complete all as specified and directed Make : M kay/AKG/Steel Kraft/BEC
All as per item No.42 above but metallic medium 25 mm dia stove enameled steel conduit ISI marked -do-
All as per item No. 42 above but metallic medium 32 mm dia stove enameled steel conduit ISI marked -do-
S&F rigid non-metallic medium 20mm dia PVC conduit ISI marked in concealed position inclusive all fitting such as tee, bends, reducer, elbow, bell mouth, tube ends and all fixing accessories such as couplers lock, nuts, saddlers, pipe hooks etc fixed properly on as in concealed/Surface position complete all as specified and directed. Make : Plaza/Kalinga/AKG
All as per item No.45 above but non-metallic medium 25 mm dia PVC conduit ISI marked -do-
All as per item No.45 above but non-metallic medium 32 mm dia PVC conduit ISI marked -do-
Cutting chases in brick walls, pinning in at the depth of 30 mm, making good to facings where required and pointing in cement mortar 1:3 cutting chases for concealed conduit wiring,submain wiring etc and making good and palstering the surface with cement or plaster of peris and matching with same colour scheme, cutting exceeding 10cm but not exceeding 30cm girth complete all as specified and directed
M&L for earthing complete with M.S. galvanized earth plate electrode 600 x 600 x 6 mm thick buried directly in ground (earth pit not less than 2.25 M deep below normal GL) with top edge of the earth plate not less than 1.5M below normal GL, connected to galvanized earth lead wire 4 mm dia by means of bolts, nuts, check nuts & washers of GI or steel incl excavation, PCC (1:3:6) type C-1 chamber with RCC cover (1:2:4) type B0, 40 mm thick reinforced with 6 mm dia bar, 3 Nos. both way, 15 mm dia light grade GI protection pipe, funnel with wire mesh,watering pipe of size 20 mm dia med. grade, lugs, main Earthing lead upto 7.5 mtr incl. Charcoal dust, salt etc. all as shown in electrical plate No. 3 of SSR Pt-I, 2009 specification complete all as specified and directed.
M&L for cutting / boring of PCC/hard standing at a depth not more than 15 cm deep and 15 cm in breadth for passing earthing conductor and making good the disturbed surfaces with PCC (1:2:4) type B-0 or cement mortar (1:3) complete all as specified and directed.
Supply and fixing of GI pipe light grade of size 15 mm bore for laying in trenches/floors or walls including all fittings for fixing complete all as specified and directed.
M&L for earth continuity conductor or main earthing lead 4 mm dia GI or steel wire fixed to wall on batten or recessed or buried in ground or drawn in conduit/pipe complete all as specified and directed
Material and labour in repair for energy saver LED Bright batten light fitting 22 watt, 230 Volts, Box type. etc and accessories, including required fixing arrangements and electrical connection three core copper cable from ceiling rose to light fitting old unserviceable bracket with sketch fitting complete all as specified and directed Make :Philips Cat pt No BN108C LED 40S PSU CDL WH or equivalent in Wipro/HAVELLS
M&L in repair for recess mounting 39 Watt RC Troffer luminaries powder coated CRCA sheet steel housing with square paralite P5 louver block in a perforated metallic frame complete all as specified and directed . Make: Philips Cat Pat -RC380B LED36S-6500 G4 L60W60 PSD OD WH OC Or equivalent in Wipro/HAVELLS
Material and labour in repair for energy saver LED Full Glow fitting 40 watt , 230 Volts, Box type. etc and accessories, including required fixing arrangements and electrical connection three core copper cable from ceiling rose to light fitting old unserviceable bracket with sketch fitting complete all as specified and directed. Make :Philips Cat pt No RC380B LED36S-6500 G5 L3W12 PSU OD or equivalent in Wipro/HAVELLS
Supply and fixing in repair Highbay light Fittings of 120/118 watt LED high pressure Die cast aluminium (LM-6) alloy housing and LED high bay luminaries of 120 watt 14300 system lumen specially designed heat sinks dust free product with company Logo engraved system wattage Max 120 watt wide beam, beam optics with 2*30 degree rotational symmetry beam beam ( for high ceiling heights) also having beam angle 110/120 degree ,PMMA material penuts lenses for effective light distribution luminous flux 14300 CRR not less then 80 ,maintenance of lumen L70 (Hrs) Power Factor 0.95 and efficiency ,surge protection 2KV voltage range 120 volt -277 volt ac with System lumen efficiency more than 105 lm/watt complete all as specified and directed. Make: Philips Cat No. BY 415 P LED 145S CW WB FG PSU GR or equivalent in WIPRO/C&S
Supply and laying or fixing or passing through pipe, commissioning and testing 1100 volts grade XLPE insulated armoured heavy duty cable with aluminum conductor of cross sectional area 25 sqmm 3.5 core using stranded conductor complete all as specified and directed.
Supply and laying or fixing or passing through pipe, commissioning and testing 1100 volts grade XLPE insulated armoured heavy duty cable with aluminum conductor of cross sectional area 35 sqmm 3.5 core using stranded conductor complete all as specified and directed.
Supply and laying or fixing or passing through pipe, commissioning and testing 1100 volts grade XLPE insulated armoured heavy duty cable with aluminum conductor of cross sectional area 16 sqmm 4 core using stranded conductor complete all as specified and directed.
Excavation in trenches in soft/loose soil not exceeding 1.5 m wide and n.exc 1.5 mtr in depth for laying of under ground electric cable and getting out complete all as specified and directed.
Returning filling in, including spreading, leveling, watering and well ramming in layers not exceeding 25cm thick in any type of soil complete all as specified and directed.
Removing excavated surplus materials to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified and directed.
Supply and spreading ganga sand dry, clean in trenches as cushioning to underground electric cable provided with a layer of 80mm deep before laying and 150mm over cable laid in trenches complete all as specified and directed.
M&L in repair for LED Building Security Light 110 watt orf alumenium PDC housing glass cover with IP 66 protection complete all as specified and directed Make: Philips cat no. brp 410 LED 110 CW HE MR FG S2 PSU GR or equivalent in Havells/ WIPRO
Supply and fix in repair of Straight Feeder of 3 Mtr Length for existing bus bar truncking sysytem (C&S CAT PART CBA 800), having 800 Amp sandwich bus way system 415 volts, 3 Phase 4 wire neutral, 5.5 kA (10 kA peak), with electrolytic Copper busbars with purity not less than 99.9% spaced with insulators F Class, with hot galvanized sheet enclosure/powder coated and minimum IP-54 protection fire retardant, type tested & certified bus way sysytem as per EIC/CEI-60439/IS 8623 (1&2) for AC application complete all as specified and directed. Make: Legrand-Zucchini/Schneider/C&S as applicable.
S & F T Elbow in repair for existing bus bar trunking system sandwich bus way system(C&S CAT PART CBA 800 )having 800 Amp 415 volts, 3 Phase 4 wire neutral, 5.5 kA (10 kA peak), with electrolytic Copper busbars with purity not less than 99.9% spaced with insulators F Class, with hot galvanized sheet enclosure/powder coated and minimum IP-54 protection fire retardant, type tested & certified bus way sysytem as per EIC/CEI-60439/IS 8623 (1&2) for AC application complete all as specified and directed
S & F Elbow in repair for existing bus bar trunking system sandwich bus way system(C&S CAT PART CBA 800 )having 800 Amp 415 volts, 3 Phase 4 wire neutral, 5.5 kA (10 kA peak), with electrolytic Copper busbars with purity not less than 99.9% spaced with insulators F Class, with hot galvanized sheet enclosure/powder coated and minimum IP-54 protection fire retardant, type tested & certified bus way sysytem as per EIC/CEI-60439/IS 8623 (1&2) for AC application complete all as specified and directed
S & F Joint cover for existing bus bar trunking system sandwich bus way system (C&S CAT PART CBA 800 ) having 800A, 415 volts, 3 Phase 4 wire neutral, 5.5 kA (10 kA peak), with electrolytic Copper busbars with purity not less than 99.9% spaced with insulators F Class, with hot galvanized sheet enclosure/powder coated and minimum IP-54 protection fire retardant, type tested & certified bus way sysytem as per EIC/CEI-60439/IS 8623 (1&2) for AC application with accessories complete all as specified and directed.
S & F in repair Straight Feeder of 3 Mtr Length for existing bus bar trunking system sandwich bus way system ((C&S CAT PART CBA 630 ) having 630 A, 415 volts, 3 Phase 4 wire neutral, 5.5 kA (10 kA peak), with electrolytic Copper busbars with purity not less than 99.9% spaced with insulators F Class, with hot galvanized sheet enclosure/powder coated and minimum IP-54 protection tap off provision min. every meter with Electrical Junction Block (with 4 silver plated contacts), fire retardant, type tested & certified bus way sysytem as per EIC/CEI-60439/IS 8623 (1&2) for AC application complete all as specified and directed Make: Legrand-Zucchini/Schneider/C&S as applicable
S & F in repair T Elbow sandwich bus way system (C&S CAT PART CBA 630 ) having 630 A, 415 volts, 3 Phase 4 wire neutral, 5.5 kA (10 kA peak), with electrolytic Copper busbars with purity not less than 99.9% spaced with insulators F Class, with hot galvanized sheet enclosure/powder coated and minimum IP-54 protection tap off provision min. every meter with Electrical Junction Block (with 4 silver plated contacts), fire retardant, type tested & certified bus way sysytem as per EIC/CEI-60439/IS 8623 (1&2) for AC application with accessories complete all as specified and directed Make: Legrand-Zucchini/Schneider/C&S as applicable
S & F in repair Elbow sandwich bus way system(C&S CAT PART CBA 630 )having 630 A, 415 volts, 3 Phase 4 wire neutral, 5.5 kA (10 kA peak), with electrolytic Copper busbars with purity not less than 99.9% spaced with insulators F Class, with hot galvanized sheet enclosure/powder coated and minimum IP-54 protection tap off provision min. every meter with Electrical Junction Block (with 4 silver plated contacts), fire retardant, type tested & certified bus way sysytem as per EIC/CEI-60439/IS 8623 (1&2) for AC application with accessories complete all as specified and directed Make: C&S or equivalent
S & F in repair Joint cover for existing bus bar trunking system sandwich bus way system(C&S CAT PART CBA 630 ) having 630 A 415 volts, 3 Phase 4 wire neutral, 5.5 kA (10 kA peak), with electrolytic Copper busbars with purity not less than 99.9% spaced with insulators F Class, with hot galvanized sheet enclosure/powder coated and minimum IP-54 protection fire retardant, type tested & certified bus way sysytem as per EIC/CEI-60439/IS 8623 (1&2) for AC application complete all as specified and directed
S & F in repair Straight Feeder of 3 Mtr Length for existing bus bar trunking system (C&S Cat Part No CBA 400)having 400 Amp 415 volts, 3 Phase 4 wire neutral, 5.5 kA (10 kA peak), with electrolytic Copper busbars with purity not less than 99.9% spaced with insulators F Class, with hot galvanized sheet enclosure/powder coated and minimum IP-54 protection fire retardant, type tested & certified bus way sysytem as per EIC/CEI-60439/IS 8623 (1&2) for AC application with accessories complete all as specified and directed
S & F in repair T Elbow for existing bus bar trunking system sandwich bus way system(C&S CAT PART CBA 400 ) having 400A, 415 volts, 3 Phase 4 wire neutral, 5.5 kA (10 kA peak), with electrolytic Copper busbars with purity not less than 99.9% spaced with insulators F Class, with hot galvanized sheet enclosure/powder coated and minimum IP-54 protection fire retardant, type tested & certified bus way sysytem as per EIC/CEI-60439/IS 8623 (1&2) for AC application with accessories complete all as specified and directed
S & F in repair Joint cover for existing bus bar trunking system sandwich bus way system (C&S CAT PART CBA400 ), 400A 415 volts, 3 Phase 4 wire neutral, 5.5 kA (10 kA peak), with electrolytic Copper busbars with purity not less than 99.9% spaced with insulators F Class, with hot galvanized sheet enclosure/powder coated and minimum IP-54 protection fire retardant, type tested & certified bus way sysytem as per EIC/CEI-60439/IS 8623 (1&2) for AC application with accessories complete all as specified and directed.
S & F in repair Suspension Bracket (02 Nos. per 3 mtr) for existing bus bar trunking system sandwitch bus way system complete all as specified and directed
S & F in repair Plug in Box along with TPN 63A ,4 pole ,415 V including industrial plug & socket 63 Amp,440 V 3 Phase complete all as specified and directed. Make: C&S cat part no PIBX-A-125 or equivalent
S & F in repair Tap off/Plug in Box including MCCB 125A , 4 Pole, 415v as per existing size and model complete all as specified and directed. Make: C &S cat part no. PIBX-N-125 or equivalent
S&F in repair LED aviation obstruction light fitting red painted die-cast aluminium alloy having red coloured polycarbonate dome and accessories suitable suitable for LED 300 twin complete all as specified and directed. Make: Bajaj BGA V 302 or equivalent in Crompton Greaves & Sudhir
Material and labour in repair for energy saver LED Bright batten light fitting 22 watt, 230 Volts, s Box type. etc and accessories, including required fixing arrangements and electrical connection three core copper cable from ceiling rose to light fitting old unserviceable bracket with sketch fitting complete all as specified and directed Make :Philips Cat pt No BN100C LED40S-6500 PSU L120 GR or equivalent in Wipro/HAVELLS
S&F three phase , 4 Pole RCCB 63A rating having sensitivity of 30mA in any surface alongwith enclosure if required or inside DB or in any location complete all as specified and directed. Make: Legrand/ Schneider/ABB
S & F hot dip galvanised perforated type cable tray of size 300mm widthx 75mm heightx 2 mm thick complete with copling plates, bends, MS barckets for supports and clamps for fixing cables on tray including nut, bolts, washers etc and other fixing materials as required at site complete all as specified and directed
S&F in repair 1100v grade pvc insulated Aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections 10mm twin core flat/round solid conductor complete all as specified and directed.
Supply and laying dry bricks over cable laid in trenches as mechanical protection to cable with width equal to the length of bricks with well burnt sub class 'B' bricks complete all as specified and directed. Note for all BOQ items:- It is to be taken into account while quoting rate that the portion of the work is to be carried out in hanger having hight up to 20 M. Necessary protective scaffolding arrangements shall be mobilised by the successful bilders and rate of which are deemed to be incluuded in the quoted rate.
YS CONSTRUCTION
kushwaha brothers
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .