Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹36.7 LAccepted-AOC 20 17 AP DEVI ROAD TITAGARH KOLKATA 700119 | KOLKATA | KOLKATA | WEST BENGAL | 700119 | 1 | Accepted-AOC L1 Bidder | |
| 2 | 2₹41.1 L+₹1.9 L (4.91%)Rejected-Finance | 2 | Rejected-Finance Not L1 Bidder | |
| 3 | 3₹43.9 L+₹4.8 L (12.2%)Rejected-Finance 15 JOGENDRA NATH GHOSAL ROAD P S BELGARIA KOLKATA 700 057 | KOLKATA | 24 PARAGANAS NORTH | WEST BENGAL | 700057 | 3 | Rejected-Finance Not L1 Bidder | |
| 4 | 4₹44.6 L+₹5.4 L (13.8%)Rejected-Finance | 4 | Rejected-Finance Not L1 Bidder | |
| 5 | 5₹45.3 L+₹6.1 L (15.6%)Rejected-Finance 79 O P ROAD NAYABASTI P O P S BARRACKPORE DIST NORTH 24 PARGANAS PIN 700 120 WB | 24 PARAGANAS NORTH | WEST BENGAL | 700120 | 5 | Rejected-Finance Not L1 Bidder |
Tender Value
₹32.5 L
EMD Value
₹65,000
Closing Date
22 Sept 2023, 12:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE NORTH KOLKATA
GE NORTH KOLKATA 46 BT ROAD KOLKATA 50
SPL REPAIRS TO BLDG NO 30 (OTM ACCN) AT ESD KANKINARA AND SPL REPAIR TO IRON DOORS AT VARIOUS LOCATIONS OF 507 ABW KANKINARA UNDER GE(N) KOLKATA
2023_MES_615702_1
8305/23-24/GE(N)/KOL/E8 OF 2023-24
Open Tender
Miscellaneous Works
Item Rate
210 days
507 ABW
AS PER TENDERDOCUMENT
8 documents required · 8 mandatory
₹500
GE NORTH KOLKATA
₹65,000
Yes
16 Oct 2023
25 Aug 2023
23 Sept 2023
26 Aug 2023
22 Sept 2023
8 Sept 2023
Amount
Taking down cement plaster on brick or stone wals, etc. including raking out joints, hacking for keys, scrubbing down with water, etc. complete all as specified and as directed.
Material and labour for rendering 15mm thick in cement mortar (1:6) on fair faces of brickwork or concrete surfaces, finished the surface even and smooth without using extra cement complete all as specified and directed.
Material and labour for preparation of newly plastered surfaces of wall by Vacuum based sanding machine , applying wall care putty 1 mm thick (Multipurpose mixer shall be used for uniform and proper mixing of putty) and applying two coat of emulsion distemper white or coloured by Auto Roller complete all as specified and as directed as per manufacturers instruction.
Material and labour for complete removal of existing treatment from old decorated plastered surfaces of wall by Vacuum based sanding machine, removal of nail etc & filling cracks/hole with putty,applying wall care putty upto 1 mm thick as required (Multipurpose mixer shall be used for uniform and proper mixing of putty) and applying two coats of emulsion distemper white or coloured by Auto Roller complete all as specified and as directed as per manufacturers instruction.
Materials and labour for rendering 20 mm thick cement plaster in cement mortar (1:4) in two layers, each 10 mm thick, top layer mixed with integral water proofing liquid admixture as per manufacturers instruction on brick or concrete surfaces of wall, finished the surface fair and even complete all as specified and as directed (WPC shall be measured and paid separately).
Material and labour for preparation of newly plastered surfaces of wall by Vacuum based sanding machine , and applying two coat of Anti Fungal Piant white or coloured by Auto Roller , including necessary scaffoldings complete all as specified and as directed as per manufacturers instruction.
Material and labour for complete removal of existing treatment from old decorated plastered surfaces of wall by Vacuum based sanding machine, removal of nail etc & filling cracks/hole with putty, and applying two coats of Anti Fungal paint white or coloured by Auto Roller , including necessary scaffoldings complete all as specified and as directed as per manufacturers instruction.
Supply only integral water proofing liquid admixture for concrete and mortar complete all as specified and as directed. (Make :CONPLAST X421IC of Fosroc /SIKA No 1 of SIKA/equivalent brand of PIDILITE)
Supply and fix anodised aluminium frame for doors,windows,ventilators(including 2/3 track) with one or more rebated including jointing cleat for fixing etc.complete all as specified and as directed
Supply and fix sliding aluminium anodized glazed shutter for sliding window with aluminium channel section weighning not less than 0.55 Kg per sqm including aluminium cleat,roller rubber neoprene packing/gusket etc complete all as specified and as directed (Note: Glass shal be measured and paid separately)
Supply and fix sliding aluminium anodized wire mesh shutter for sliding window with aluminium channel section weighning not less than 0.55 Kg per sqm including aluminium cleat,roller rubber neoprene packing/gusket etc complete all as specified and as directed (Note: Wiremesh shall be measured and paid separately)
Supply and fix Stainless steel wire cloth of 0.36 mm nominal dia of wire and average width of aperature 1.40 mm fixed with stainless steel wire staples all complete as specified.
Supply and fix 4.0 mm thick sheet glass ordinary quality and glazing with oil putty in square exc 0.50 sqm in each pane, complete as specified and as directed.
Taking down chowkhat / aluminium frames with shutter n.exc. 1.50 Sqm each (without taking off shutter from the frames.) complete all as specified and as directed.
Taking down chowkhats / aluminium frames with single or double shutter (without taking off shutter from the frame) exc 1.50 and not exc. 4.00 Sqm in each complete all as specified and directed.
Dismantling of ceiling of any description in any position, fixed with nails including fillets all as directed by Engr-in-charge.
Supply and fix anodised aluminium snap grid frame work(size of 605x605mm) for false ceiling including suspenders/hangers 6mm dia GI wire(upto 1200mm length) adjusting level fixed to roof shads by means of ceiling cleats made out of GI flat 40x3 mm size 60mm long and expansio hold fasteners 12.5mm dia 40mm long complete all as specified as per manufacturers instruction.
Supply and fix of 6mm thick high pressure steam cured non asbestos fibre cement designer ceiling board of size grid mould(605x605mmas specified above) and fix in grid mould with necessary fixing arrangement complete all as specified and as directed.
Taking out old unserviceable floor, hearth or wall tiling including cement mortar bedding (but not backing and rubbish off the premises complete all as specified and as directed.
Material and labour for light shade ceramic tiles 7-8 mm thick (square/rectangular) polished, area of each tiles exc 0.18 sqm and nexc 0.38 of each tile in floor set and jointed in neat cement slurry & pointed in white cement and pigment to match the colour of tiles over and including 15mm thick screed bed in cement mortar (1:6) complete all as specified and as directed.
Material and labour for light shade vitrified tiles 10mm thick (square/rectangular) polished, area of each tiles exc. 0.18 sqm but n.exc. 0.36 sqm in skirting etc set and jointed in neat cement slurry and pointed in white or coloured cement to match the colour tiles over and including 10mm thick rendering in CM(1:4) complete all as specified and as directed.
S &F aluminium door frame and shutter single leaf panelled door partly glazed and partly pre-laminated board door shutter divided into two panels fabricated including aluminium anodised snap beading and rubber gasket/lining for fixing of glass and pre-laminated board panel. The door frame shall be fixed aluminium anodised bolt by drilling in the existing wall and with thrust bolt of suitable size. The door frame and shutter shall be comprising of the following section and fitting complete all as specified and as directed by engineer-in-charge. (a) Aluminium anodised door frame section 101.6x44.5x1.27 mm (b) Aluminium anodised styles of shutter section 85x44.5x1.56 mm (c) Aluminium anodised top & bottom rail of shutter section 101.6x44.5x2.5 mm (d) Aluminium anodised middle/lock rail of shutter section 100x44.45x2 mm (e) Aluminium anodised handle 250 mm long 02 Nos in each shutter (f) Aluminium anodised tower bolt 200 mm long as required as per normal (g) Six lever mortice lock brass (h) floor spring (i) 12 mm thick pre-laminated board. (j) 5.5 mm thick glass (Note: In case of two leaf each leaf will be measured seperately.)
Demolition of brickwork of any description and in any position not otherwise specifically provided for complete all as specified and as directed .
M&L for Brick work with sub class 'B' bricks old size, straight or curved on plan exceeding 6M mean radius built in cement mortar (1:6) complete all as specified and directed.
Dismantling wrought iron or mild steel work in steel gate of height n.exc 10.00 m or of any description not otherwise provided for complete all as specified and as directed.
Supply and fix Framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors of height n.exc 10 m to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings Fe 410 -W (GdeE- 250) quality A (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing along with painted one shop coat of zinc chromate primer paint (including preparation of surface) at Contractor’s workshop before fabrication complete all as specified and as directed.
Supply and fix Rolled mild steel in Joist, channel, angle, or tee sections, Fe 410 -W (GdeE- 250) quality A fixed independently, without connecting plates, etc.upto height n. exc 10.00 m complete all as specified and as directed.
Supply and fix in repair 1.25 mm Mild steel plain, black sheet in steel gates and similar work, cut to size, holes punched; including round headed screws, clout nails or rivets and fixed to wood or steel framing upto height 10.00 m with plain 40 mm lap joints with riveted or welded seams, including bending or turning up, mitred angles, etc. as required complete all as specified and as directed.
Material and Labour for preparation of surface and applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer on new steel surface exc 10 cm width or girth complete all as specified and as directed .
Material and Labour for preparation of surface and applying one coat of synthetic enamel paint on old steel surface exc 10 cm width or girth complete all as specified and as directed .
Dismantling Plain or corrugated steel sheeting, any gauge, thickness, including roof coverings/walls etc complete all as specified and as directed
Supply and fix 0.63 mm thick CGI sheet for covering to door shutter and walling cladding, steel gates and similar work of height n exc 10.00 m, cut to size, holes punched; including round headed screws, clout nails or rivets and fixed to wood or steel framing with plain 40 mm lap joints with riveted or welded seams, including bending or turning up, mitred angles, etc. as required complete all as specified and as directed( Note: Grade of Zinc coating 275)
Supply and fix in repair MS hook or pintle hinges for large gate / door conforming to Fe 290 Gde E-165 complete all as specified as directed.
Supply and fix in repair Mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, n exc 5cm long complete all as specified and as directed
Running welding in repairs to metal thickness n.exc 6 mm complete all as specified as directed.
Welding in repair n.exc 2.5 cm in length to metal thickness n.exc 6 mm complete all as specified as directed.
Supply and fix in repairs of Iron Shaft for rolling shutters n.exc 5.50m span shutters and making good of walls with existing finishes complete all as specified as directed. Note: Contractor shall arrange necessary scaffolding for fixing and repair at his own cost.
Supply and fix in repairs of Iron Spring for rolling shutters n.exc 5.50m span shutters and making good of walls with existing finishes complete all as specified as directed. Note: Contractor shall arrange necessary scaffolding for fixing and repair at his own cost.
Material and labour for Resecuring,Easing,Greasing / lubricating to Sliding Iron shutters including guide rails/ Side hung Iron shutters exc 10 Sqm and not exc 50 sqm in area and making good of walls with existing finishes complete all as specified as directed. Note: Contractor shall arrange necessary scaffolding or repair at his own cost.
Material and labour for Resecuring,Easing,Greasing / lubricating to rolling shutters exc 10 Sqm and not exc 50 sqm in area and making good of walls with existing finishes complete all as specified as directed. Note: Contractor shall arrange necessary scaffolding for repair at his own cost.
Supply and Fix in repairs 1.00 mm thick Steel rolling shutters, without ball bearing, as specified including top cover, anchoring rod, hasp and staple and one shop coat of primer, erected in position as indicated, gear operated type with chain wheel and hand chain complete all as specified and as directed. Note: Contractor shall arrange necessary scaffolding for repair at his own cost.
Supply and fix in repairs Safety lever locks mild steel with 4 levers for rolling shutters and making good of walls with existing finishes complete all as specified and as directed. Note: Contractor shall arrange necessary scaffolding for repair at his own cost.
Supply and fix in repairs Ball bearing for rolling shutters and making good of walls with existing finishes complete all as specified and as directed. Note: Contractor shall arrange necessary scaffolding for repair at his own cost.
Demolition of cement concrete of any description and in any position not otherwise specifically provided for complete all as specified and as directed .
Material and Labour for PCC 1:2:4 Type B1 ( using 20 mm graded stone aggregate ) as in fixing hold fast for iron door including necessary formwork complete all as specified and as directed .
M&L for applying three coats of white wash to newly plastered surfaces of walls including preparation of surfaces complete all as specified and directed.
Taking down copper / aluminium point wiring any type complete, including fixture and fittings any type removing materials for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc.surfaces, complete all as specified and directed.
Taking down ceiling fan/Exhaust fan from existing position and kept in store under safe custody for refixing the same on existing postion complete all as specified and as directed.
Hanging only ceiling fan and connecting up including provision of cable from ceiling rose or connector to fan complete all as specified and directed.
Fixing only ceiling Exhaust fan and connecting up including provision of cable from ceiling rose or connector to fan complete all as specified and directed.
Material and labour for concealed point wiring with FRLS PVC insulated 1100 volts grade unsheathed single core multi-stranded copper conductors 1.5 sqmm for phase,1.5 sqmm for neutral and 1.5 sqmm for earth continuty conductor drawn through and including PVC conduit medium grade with accessories of suitable size but not less than 20 mm and including suitable size of pressed steel sunken terminal box duly painted MS sheet and covered with suitable size thick insulated hylum sheet cover for fixing of switches, sockets etc for one light point controlled by one switch .complete all as specified as directed. Note :(i) Cost of cutting of wall, if any, for housing of GI box, ceiling rose,and pvc conduit for wiring etc and also making good the disturbed surfaces are deemed to be included in unit rate.
All as per Item No. 51 above but for One ceiling fan/ exaust fan point controlled by one switch and one regulator complete all as specified and as directed.
All as per Item No. 51 above but for One 3/5pin 6 Amp Socket outlet on the independent board complete all as specified and as directed.
All as per Item No. 51 above but for One 3/5pin 6 Amp Socket outlet on the same board complete all as specified and as directed.
All as per Item No. 51 above but for One call bell point controlled by one switch complete all as specified and as directed.
All as per Item No. 51 above but for FRLS PVC insulated 1100 volts grade unsheathed single core multistranded copper conductors 2.5 sqmm for fixing of 16 A switches, sockets, etc complete all as specified and as directed.
Supply and fix switch piano flush button 5 Amp single pole one way 240 volt complete all as specified and as directed.
Supply and fix socket out let 3/5 pin 5 Amp 240 volt complete all as specified and as directed.
Supply and fix switch socket combination 3/5 pin 5 Amp 240 volt complete all as specified and as directed.
Supply and fix switch socket combination 3/6 pin 15 Amp flush type 240 volt complete all as specified and as directed.
Supply and fix celling fan regulator (step regulator) switch type AC 230 volt suitable for ceilling fan any sweep all as specified and directed
Supply and fix bell push 6 amps complete all as specified as directed.
Matetial and labour for call bell ding dong type AC 230 volt single pole complete all as specified as directed.
Supply and fix celling rose surface,3 terminal ISI marked complete all as specified and as directed.
Matetial and labour for lamp holder PVC/Polycarbonate type with backplate suitable for batten fittings complete all as specified as directed
Supply and fix box type luminiare, pre coated in white and pre-wired for single LED tube light 4 ft capacity suitable for single T8 LED tube rod 4ft 20 watt complete with LED tube rod T8, 20 W, 4ft long with extruded aluminium body, PC diffuser and inbuilt driver, holder and connecting up with three core twisted flexible copper conductor cable of suitable size from ceiling rose to connector of tube light fitting including taking down old unserviceable fitting any type complete all as specified and as directed. Make: Centrury LED Ltd / Surya / Wipro / Philips/Bajaj/Havells.
Supply and fixing LED batten mirror light 10 Watt extruded aluminium body, PC diffuser and inbuilt driver, prewired with electronic driver and diffuser and all accessories fitted on including / ceiling including connecting up with three core twisted flexible copper conductor cable of suitable size including taking down the old light fitting any type complete all as specified and as directed. Make: Centrury LED Ltd / Surya / Wipro / Philips/Bajaj/Havells.
Supply and fix LED light fitting (ceiling) recessed/ surface mounted 600mm x 600mm 36 watt LED provided with high transmission crylic cover polycarbonate diffuser modular to be fitted on POP/ Gypsum cealing lampwhite powder coated CRCA housing luminare including necessary electric connection with three core twisted flexible copper cable of suitable size from ceiling rose to connector of of light fitting complete including taking down unsv light fitting complete all as specified and as directed. Make: Centrury LED Ltd / Surya / Wipro / Philips/Bajaj/Havells.
Material and labour for sub-main wiring in repairs with two run of FRLS PVC insulated unshethed single core multi-stranded copper conductor of size 6 sqmm and one run of 6 sqmm copper conductor as continuity earth wire drawn in and including PVC conduit of suitable size but not less than 20mm dia on shed/ wall / iron channel etc, including PVC fittings such as bends Tee and boxes including taking down old unserviceable sub main wiring of any size in steel/ PVC rigid conduit complete all as specified and directed (Note : (i) Two run of 6 sqmm cable one run of 6 sqmm cable alongwith PVC conduit shall be measured and paid as one unit. (ii) Cost of cutting of wall/ fixing material such as GI wire of suitable size / any item, if any, required for housing of PVC casing conduit etc and also making good the disturbed surfaces are deemed to be included in unit rate. (iii) Cost of chase cutting if any for submain wiring shall be deemed to be included in the quoted rate).
Supply and fix powder coated sheet steel enclosure fitted with busbar, DIN channel, neutral link & earth link superline SPN DB (Double door) 8 way 240V, including taking down the old unserviceable DB complete all as specified as directed.
Supply and fix powder coated sheet steel enclosure fitted with busbar, DIN channel, neutral link & earth link superline SPN DB (Double door) 4 way 240V, including taking down the old unserviceable DB complete all as specified as directed.
Supply and fix MCB single pole & neutral 32-40 amps, 240 volts, 'C' series with all incoming / outgoing connections with proper size of lugs complete all as specified as directed.
Supply and fix MCB single pole 6 to 32 amps, 240 volts, 10 KA, 'C' series with all incoming / outgoing connections with proper size of aluminium lugs complete all as specified as directed.
Supply and fix Blanking plate for MCB DB complete all as specified as directed.
Materials and labour for earthing complete with galvanized earth plate electrode 600 x 600 x 6.0 mm thick, buried directly in ground (earth pit not less than 2.25 m deep below normal ground level ) with top edge of the plate not less than 1.5 m below normal ground level, connected to galvanized iron earth lead wire 4.0 mm dia length upto 7.5 mtr by means of bolts, nuts, check nuts and washers of galvanized iron or steel, earth lead wire protected by and including 15mm dia GI pipe (light grade) not exc 7.5 mtr, alternate layers of charcoal and salt, including 20 mm bore GI tubing for watering to earth electrode, earth lead connected to test point/ distribution panel /feeder pillar etc as directed including necessary earth work, concrete pit with PCC (1:3:6) type C1, pre cast RCC(1:1:5:3) type A1 cover slab duly reinforced with 8 mm dia TMT bar 150mm c/c both way and two numbers lifting handle made of TMT bar and set in cement mortar (1:4), funnel, wire mesh, all as shown in electrical plate No 3 of SSR part-1 and testing on completion including taking out old earthing complete all as specified and directed.
S&F Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 4mm dia galvanised iron or steel wire including taking out old wire complete all as specified and directed.
S&F GI pipe 15 mm bore 'light grade' galvanised, with all fitting and fixed complete to walls and ceilings or laid in floors including taking out old pipe complete all as specified and directed.
Supply and fix sheet steel enclosure fitted with plug & socket metal clad AC box with MCB SP 20A 240 V including insulated neutral link, adjustable DIN rail channel and connecting links complete after taking down the old socket board and connection complete all as specified as directed. Make: C&S / L&T/ Indoasian / Havells
Supply and fixing TPN DB 4 way double door 415 V horizontal type suitable for four pole MCB TPN as incomer including make good of damaged surface/wall including re-connection with existing earth wire to DB incuding taking out the old unserviceable one complete all as specified and as directed.Note:- MCB shall be measured and paid seperatly. Make: C&S/L&T/ Indoasian/ Havells/Bentec.
Supply and fix MCB TPN 63 amps, 415 volts, 'C' series with all incoming / outgoing connections with proper size of lugs complete all as specified as directed. Make: C&S/ L&T/ INDOASIAN / Havells/Bentec
Matetial and labour for sub-main wiring with two run of FRLS PVC insulated unshethed single core multi-stranded copper conductor of size 4 sqmm and one run of 4 sqmm copper conductor as continuity earth wire drawn in and including PVC casing caping / PVC conduit medium duty of suitable size but not less than 20 mm dia on wall / floor etc, including PVC fittings such as bends Tee and boxes including taking down old unserviceable sub main wiring of any size in steel/ PVC rigid conduit complete all as specified and directed. (Note : (i) Three run of 4 sqmm Submain wire one run of PVC conduit shall be measured and paid as one unit. (ii) Cost of wall cutting if any for laying of Submain wire and also making good surfaces are deemed to be included in unit rate).
B G Trading Co.
RBS Builders
CHOWDHURY SMALL INDUSTRIES
ALOKE ENGINEERING AND COMPANY
The Planters Engineering Corporation
PUJA ELECTRICALS
SHIVAM ENTERPRISE
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .