| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹10.1 LAccepted-AOC BLOCK NO 6 7 WING NO 3 RAHUL COMPLEX I ST BUS STAND GANESHPETH GANESHPETH NAGPUR NAGPUR MAHARASHTRA 440018 | NAGPUR | MAHARASHTRA | 440018 | L1 | Accepted-AOC LOWEST BIDDER. | |
| 2 | L2₹11.5 L+₹1.1 L (11.1%)Rejected-AOC 37 A 19 3 B MADHU NAGAR AGRA UP | AGRA | AGRA | UTTAR PRADESH | 282001 | L2 | Rejected-AOC NOT LOWEST BIDDER. | |
| 3 | L3₹12.9 L+₹2.6 L (25.2%)Rejected-AOC NO 133 RASHTRAPATHI ROAD SECUNDERABAD 500 003 | SECUNDERABAD | HYDERABAD | TELANGANA | 500003 | L3 | Rejected-AOC NOT LOWEST BIDDER. |
Tender Value
₹12.0 L
EMD Value
₹24,000
Closing Date
29 Feb 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
LT COL SANDEEP BENIWAL, GE
OFFICE OF GARRISON ENGINEER AIR FORCE VAYUSENA NAGAR NAGPUR- 440007
REPAIR MAINTANENCE OF CENTRAL AIR COOLING SYSTEM AT COMMAND BLDG AT VSN NAGPUR
2024_MES_640251_1
8657
Open Tender
Civil Works
Item Rate
180 days
GE AF NAGPUR
As per tender documents
7 documents required · 7 mandatory
₹500
GE AF NAGPUR
₹24,000
17 Apr 2024
1 Feb 2024
7 Mar 2024
1 Feb 2024
29 Feb 2024
15 Feb 2024
Amount
Material and labour for preparation of old painted surface of bottom tank of AIR washer chamber size approx 4.5mtr X 1.5mtr X 0.3 mtr by removing all dirt, dust, grease, oil etc and painting complete with two coats of water proof paint of approved colour over a coat of red-oxide primer on entire inside surface of tank complete all as specified and directed . Make: Asian paint/ Berger/ Nerolac paint Note:(1) At the time of painting process cost of opening & refixing of filter pad ,angle or tank, cost of nut, bolt ,washers etc shall deemed to be included included in quoted rate.
Material and labour for taking down electric motor 30/25 HP 415 volt coupled to blower unit after disconnecting the electrical connection, and earth connections removing from its foundation and transport to work shop for checking the serviceability of both side bearing of motor , greasing of bearing up to free rotation of shaft of motor, greasing after reassemblying the motor complete, re-installation on foundation, reconnecting back the cable and earth connections and varnsihing, drying, opening, overhauling , greasing , alignment of pump/motor poperly tthrough authorised mechanic including repair to foundation if required at site etc complete in all respect and starting the pump all as directed. Note:(1) Contractor shall be responsible for maintaining required RPM after repair and non compliance of speed required shall be considered as incomplete repair. (2) Cost of rewinnding & bearings shall be measured and paid separately.
Taking down electric motor 0.5 upto 1 HP 415 volt coupled to pump after disconnecting the electrical connection, and earth connections removing from its foundation and transport to work shop for checking the serviceability of both side bearing of motor , greasing of bearing up to free rotation of shaft of motor complete, greasing after reassemblying the motor to re-installation on foundation, reconnecting back the cable and earth connections and varnsihing, drying, ovening, overhauling , greasing ,alignment pump/motor poperly through authorised mechanic including priming of PVC foot valve etc complete in all respect and starting the pump all as directed. Note :(1) Cost of rewinding , Bearings shall be measured and paid separately under relevent item. (2) Contractor shall be responsible for maintaining required RPM after repair including priming work to motor, taking out water cellouse padsand and non compliance of speed considered as incomplete repair
Supply only spare parts required for motor/ pump set of capacity 30/25 HP vide sr item No.2 as follows:-
a) Supply only shaft of AHU motor any make any size as per exiting motor at site of capacty 25/35HP complete.
b) Supply only check nut including gasket
c) Supply only bearing as per existing site requirement fitted in motor complete Make : SKF/ Timker/ NSK
Material and labour for preparation of old painted surface of pump installation by removing all dirt, dust, grease, oil etc and painting complete with two coats of synthetic enamel paint for spray painting including writing MES No of approved colour over a coat of red-oxide primer on air blower motor /blower stand / and floor of ambient chamber , water pump icluding motor of capacity upto 35 HP Including 0.5 HP water pump complete all as specified and directed .
Material and labour for dismantling of existing defective/unsv motor of following capacity/ HP, three phase/Single phase , 415 V, 50 Hz, from the foundation, disconnecting the electric connection, coupling pulley, transport to work shop, seperating the stator and rotor assembly ,cutting down and removing existing burnt out copper windings, cleaning of slots and rewinding of stator with super enamelled solid copper conductor (winding wire) of appropriate gauge and size to match with the existing winding motor so as to acheive desired RPM including varnishing, drying, ovening, overhauling, greasing, provising insualtion and reassembling stator and rotor connecting coils/ winding in star and delta mode at the junction box/ terminal fixing in the same position, making necessary electric connection and testing of induction motor complete all as specified and as directed.
(a) 0.5 up to 1 HP
Taking down u/s and supply and fixing industrial exhaust fan axial flow motor with blade and frame heavy duty industrial exhaust fan (36 inch/ with IP 55 specification, rigid frame with rubber mounting for silent operation epoxy powder coated and better resistance to corrosion and scid alkali fumes , totally enclosed highly efficient heavy duty copper motor including testing of motor with suitable copper wire winding ,incl refixing of exhaust fan motor with blade and frame, AC, volts, Heavy duty and blades 36 inch sweep, suitable for air washer plant.
Taking down U/S & supply & fixing V belt cat part MN 30 for capacity of 30000 to 40000 cfm blower motor suitable for the existing plant size 32/20 Make: Mitsuboshi/ Dunlop/ Poly-F
Supply & install blower pully as per existing blower capacity fitted in site for air washer ambiator chamber including taking down old u/s pulley complete All as specified directed by Engr-in-charge. (Sample availabe as AGE E/M office)
Taking down U/S old nitrile insulation / glass insulation & supply and fixing new Nitrile insulation 25 mm thick nitrile rubber sheet with suitable adhesive as per (manufacturer's instruction) of duct work fixed out side of duct/ inside duct and air washer chamber for weather proofing using 25 mm thick nitrile rubber sheet fixing with complete all as specified and all as directed. Note: (1) The cost of maintnence of Nitrile insulation patch occured during contract period shall deemed to be included in the quoted rate. (2) The quoted rate shall deemed to be included cost of fixing of aluminium strip. Make : K-flex/Armacel/Suprem
Suply and fixing aluminium strip 25x3 mm thick by proving suitable support to fixing of nitrile insulation inisde/outside of AHU and duct for air washer plant. Note: The quoted rate shall deemed to be included cost of making holes in strip , nut bolts and washers etc all as specified and as directed,
Taking down U/S and Supply and fixing short neck of duct connected with air diffuser with long type and complete fixing with air sealed diffuser for avoiding of noise and air leakge . Note : If found leakge or noise in the duct or plant the contractor has responsible to repair without any extra cost.
Taking down U/S & supply and fix high performance plated panel or air pre-filters for central cooling system and general ventilation used as pre filtration made of GI /Aluminium construction having efficiency 90% down to 20 micron suitable for existing plant size of filter 60cmx60cm having features low initial pressure drop, disposable,washable , maintenance free, compact design (sample available as AGE E/M office) Make : Alpha Kel India/AAF Camfil/Freudenberg
Taking down U/S & supply and fixing high performance plated panel or air pre-filters for central cooling system and general ventilation used as pre filtration made of GI /Aluminium construction having efficiency 90% down to 20 micron suitable for existing plant size of filter 30cmx30cm, having features low initial pressure drop, disposable,washable , maintenance free, compact design Note : Sample available as AGE E/M office
Material and labour for cleaning of rusted portion of duct and dust settled in existing duct & dampers in whole building where is passing of duct and Air all floors going from main duct to connected branch duct number unit duct and diffusers and open of AHU cleaning the portion & refixing the same plant by using suitable equipment or suction machine/compressor from AHU to neck duct complete all as specified and all as directed. Note: the quoted rate shall deemed to be included painting of rusted portion of duct with red oxide paint.
Material and labour for comprhensive mainnence /overhauling /repair of complete air washer ambiator chamber including necessary oiling/greasing , cleaning and re-alignment motor properly by technician of any motor aliignment with blower of existing plant of capacity 10000 to 40000 CFM grease gun should be used for greasing whenever necessary complete all as specified and all as directed. Make of Greasing : Castrol/ Lithium Grease/ Servo MP3 Note :(1) The materias for oil/Greasing including labour shall be provided by the contractor without any extra payment.
Taking down U/S & supply and fixing aluminium grills for air supply made out of powder coated extruded aluminium grils adjustable type with variable angle and vertical & horizantal louvers and gap between louvers should be 25 mm with volume controls dampers complete all as directed Make:Aircon Airiqpment/Mapro/Air flow Note : (a) Damage of aluminium grill fitted in site including cutting of wall and POP work shall deemed to be included the quoted rate .
Taking down U/S cellulose or celldek pads and supply and fix new consists for cellulose wood fibres in paper form having high quality standard and posses on efficiency of more than 85% as per site all as directed. (sample available as AGE E/M office) Make Hutek/Munters/DRI Note : Contractor should be noted that only damaged portion is to be changed.
Supply only grease suitable for pump bearings
Taking out U/S & supply and fix ball Bearing for blower shaft fitted in site for air washer ambiator chamber complete all as specified and directed. (sample available as AGE E/M office) NOTE -:1) the cost of opening of blower drum & shaft including all types of nut,bolt,washer,packing etc and after replacing the bearing fixing the same inside the air washer ambiator chamber complete shall deemed to be included in quoted rate.
Takin down U/S & supply & install motor pulley as per existing motor capacity fitted at site for air washer ambiator chamber complete all as specified directed.(Sample availabe as AGE E/M office)
Taking down u/s exhaust fan heavy duty of size 36 " and removing old unsv copper winding , re-winding the same with existing gauage copper wire winding complete including testing after rewinding and repainting with existing colour and refixing in original position complete all as directed.
Taking down u/s and Supply and fix MCB 4 pole 63 amps, breaking capacity 10 KA, confirming to IEC60947-2, 415 volts, 50 Hz including making necessary incoming and out going electrical connection with suitable size of copper lugs etc. Make : Legrand / Siemens/ L & T
Taking out unservicable & Supply and fix MCCB 4 pole 200 amp , breaking capacity 36 Ka, 415 volts, 50 Hz confirming to IEC60947-2 including necessary incoming and out going electric connection with suitable size of copper lugs etc. Make : Legrand / Siemens/ L & T
Taking down U/S Air cooler ambient chamber tray (tray size sample availble at site) and M & L for air cooler ambient chamber tray by using 2 mm thick GI Sheet including necessary cutting ,welding fabricating etc for complete tray/portion of tray etc required for fabrication and tightining of door handle and damage any door handle to replaced the same complete all as specified directed Note 1) The quoted rate shall deemed to be included cost for suitable arrangemnt for welding machine , electric arrangemnet / gas cyclinder . Note 2) The quoted rate shall deemed to be included cost for dismantling of pre air filter, water pump , water piping and cellulose pads from water cooler tray and refixing of the same after rectification of leakage and completely leak proof arrangementof tray all as specified and as directed. If any air filter / celluose pads damaged during execution , the same shall be rectify by the contractor with any extras payment.
Taking out u/s and supply and fix PVC insulated 1100 volt grade heavy duty cable multistranded copper conductor and connecting upto the eectrical system of size 4 sqmm 3 core complete all as specified.
All as per item No 31 above but of size 2.5 sqmm 3 core
Taking out unserviceable control burnt wiring including unserviceable spares from control panel of central air cooling duct and M & L for repair, relaying and new electrical interlocking wiring of LT panel of air cooling System control wiring with FRLS copper wire of existing size including all connected lugs, cable, fuses complete all as specified and directed . NOTES :- (i) The cost of minor spares required including connector, lugs, wire/cable, fuses as required is deemed to be included in the quoted rate. (ii) Spares parts required during repairing of the electric panel will be measured and paid separately under relevant items.
Supply only RYB indicator Make : Schneider/ L&T/ Siemens
Supply only voltmeter CTs 0-500 Volt Digital type Make : Schneider/ L&T/ Siemens
Supply only Amp meter CTs 0-300 Amps Make : Schneider/ L&T/ Siemens
Supply only over laod relay range 0.2-15 A Make: Make : Schneider/ L&T/ Siemens
Supply only Auxillary contactor 2 NO-2 NC Make : Schneider/L&T/Siemens
Supply only on delay timer 0.2 to 60 second Make : Schneider/L&T/Siemens
Supply only push button start/ stop Make : Schneider/L&T/Siemens
Supply only red indication Make : Schneider/ L&T/ Siemens
Supply only yellow indication LED neon bulb Make : Schneider/ L&T/ Siemens
Supply only green indication LED neon bulb Make : Schneider/ L&T/ Siemens
Taking down u/s and supply and fix 4 sqmm copper wire for internal wiring single core FRLS
Taking down u/s and supply and fix suitable size copper lugs/thimble fitted in motor
Supply only Add on 2 NO - 02 NC M MCX 9-80/MO 9-110 Make : Schneider/L&T/Siemens/ Legrand
Supply only spreader link kit Make : Schneider/L&T/Siemens
Supply, Installation, testing & commissioning of Galvanized-Class VIII with zinc coating of 120 gm / Sqmt surface area as per IS-277. With TDF/TDC Flange system with factory fabricated box section with neoprene rubber gaskets of thickness to match the dimensions of the ducts shall be used for connecting two ducts.(The Minimum duct Gauge should be of 20 Gauge only.) Duct construction and installation shall be in accordance with Standards and all ducts testing pressure should be 500 Pascal. (pa) The Duct shall be supported with GI steel Rods & MS angle Supports at regular intervals. Ducts should be factory fabricated & transportation should be in box section only to site. At site the duct needs to be stored in proper manner & covered with polythene sheets to avoid dust accumulation. The guages sutable as per size of 18/20 guages.
Taking out unserviceable & S &F MCCB 4 pole 100 amp, breaking capacity 16 Ka, 415 volts, 50 Hz including necessary incoming and out going electric connection with suitable size of copper lugs etc. :Make- Schneider/ L&T/ Siemens/ Legrand
Supply only power contactor 3 pole 415V AC type 32A MNX 50 complete all as specified and directed. Make : Schneider/ L&T/ Siemens/ Legrand
All as per item No 51 above but 16A MNX 50
Supply only electronic type ET 100 with time range 0 to 60 second, 360 Volt complete all as specified and directed. Make : Schneider/ L&T/ Siemens/ Legrand
Taking out u/s and supply and fix PVC insulated 1100 volt grade heavy duty cable multistranded copper conductor and connecting panel to Exhust fan to the electrical system of size 4 sqmm 3 core complete all as specified
Taking down U/s and supply and fix Push Button Remote Kit Make : Schneider/ L&T/ Siemens/ Legrand
Taking down U/S & dismanteling of canvas air washer to duct supply and fix high performance double layered flexible canvas duct to airwaisher Make- Resistoflex/ Donlop Aircon/Air equipment
Disconnecting, dismantling and removing central shaft of air handling units of central Air cooling system of any capacity and any make for repair, transporting to the work shop, opening up for repairs carry out the repairs, of shaft including re-metalling, turning, brazing and polishing work of AHU shaft of any size, cleaning, greasing and overhauling incld replacement of unserviceable/worn out ball bearing and other minor spares, reassembling after repairs, bringing back to its location fixing in original position, connecting instt, and testing on full load capacity and commissioning to the entire satisfaction of Engr in charge. Note : Unit rate quoted by tenderers shall deem to incl cost for nuts, bolts, washers , lugs, thimbles, wires and petty items required for efficient and smooth functioning of the equipment without any extra cost to the Deptt.
Charges for attending break down of centrai air cooling system of capacity 1000CFM to 40000CFM by technical person or team fault finding including attending repairs as and when required such as No start condition of Air cooling system and repairing, starting the Air cooling system till smooth running and setting up the alignment/required parameters of all major parts such as fan belt, motor ,exhaust fan power contactor, starter, MCCBs, control panel, pumps etc as required in ground/as ordered by EIC complete all as specified and as directed.
Supply, installation and testing of multi -blade type key operated louver dampers of galvanised steel sheet for collars to be provided with suitable links, levers and quadrants for manual control of volume of air flow and for proper balancing of the air distribution system as per the approved shop drawings and specifications.
Supply & fix in repair ultra violet UV barrel of size approx 12 inch in length (as exting at air washer) including addn/alteration of necessary cutting ,welding & connection of pipe complete all as directed by Eng-In-charge.
M/S J J ENTERPRISES
THE DECAN ENGINEERING AND REFRIGERATION COMPANY
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .