Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Infra Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹30.5 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹40.0 L+₹2.9 L (7.93%)Rejected-Finance VILL CHOMON ADAMPUR JALANDHAR PUNJAB 144103 UDYAM PB 10 0011450 | JALANDHAR | PUNJAB | 144103 | L2 | Rejected-Finance Other than lowest. | |
| 3 | L3₹40.1 L+₹3.1 L (8.26%)Rejected-Finance 0000 UNNAMED ROAD GAJIYA KANTIT VINDHYACHAL MIRZAPUR UTTAR PRADESH 231307 | MIRZAPUR | UTTAR PRADESH | 231307 | L3 | Rejected-Finance Other than lowest. | |
| 4 | L4₹40.2 L+₹3.1 L (8.49%)Rejected-Finance 1798 SECTOR 60 SAS NAGAR MOHALI 144102 PB | MOHALI | MOHALI | PUNJAB | 144102 | L4 | Rejected-Finance Other than lowest. | |
| 5 | L5₹41.1 L+₹4.0 L (10.9%)Rejected-Finance AWADHI ROAD ADAJAN 1ST 102 DABKA NO 1 1 6 4 C 4TH FLOOR | GANDHINAGAR | L5 | Rejected-Finance Other than lowest. |
Tender Value
Refer Docs
EMD Value
₹80,000
Closing Date
24 Feb 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE AF Adampur
Military Engineer services AF Stn Adampur 144103
REPAIR / REPLACEMENT AND IMPROVEMENT OF EM INSTALLATION INCLUDING MISC WORKS AT AF STN ADAMPUR
2024_MES_639475_1
GE/AF/ADM-63/2023-24
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE AF Adampur
Refer NIT and Tender Documents
8 documents required · 8 mandatory
₹500
GE AF Adampur
₹80,000
Yes
18 Apr 2024
29 Jan 2024
26 Feb 2024
29 Jan 2024
24 Feb 2024
13 Feb 2024
30 Jan 2024 - 12 Feb 2024
Amount
Excavation in trenches n. exc 1.5 m wide for foundations, laying cables / pipes etc. not exceeding 1.5 m deep and getting out in soft/ loose soil complete, all as specified.
Returning filling in including spreading, levelling, watering and well ramming in layers not exceeding 25cm thick complete, all as specified.
Removal of excavated surplus spoil to a distance n. exc. 50m and depositing where directed at level not exceeding 1.5 m above the starting point complete, all as specified.
Clean dry sand ( locally available) as cushioning for under ground cable 230 mm thick (one layer of 80 mm thickness before laying the cable and other layer of 150 mm thickness after laying the cable) complete all as specified. NOTE:- Punned down thickness (over all 180 mm) shall be considered for measurement and payment.
Bricks as specified in PS clause 5.1, laid flat and dry in trenches over the cable for protection as length perpendicular to the direction of cable adjacent to each other complete, all as specified.
GI pipe light grade with all fittings fixed as termination postal ,fixed to poles/ walls/ under floors/ under road etc including takind down existing pipe complete all as specified of following size: -
40mm bore
50mm bore
Supply, laying, jointing & testing of LT XLPE insulated cable screened, bedded, galvanised steel strip or wire armourd cable (heavy duty) 1100 volt grade with aluminium conductor conforming to IS-7098 (Part-I -1988) laid in trenches/ ducts/ through pipes/ in floors / under roads/ hard standing /along poles and testing including takind down existing cable complete all as specified of sectional area: -
16 Sq.mm,4 core
25 Sq.mm,4 core
35 Sq.mm,3.5 core
50 Sq.mm,3.5 core
70 Sq.mm,3.5 core
95 Sq.mm,3.5 core
120 Sq.mm,3.5 core
150 Sq.mm,3.5 core
185 Sq.mm,3.5 core
240 Sq.mm,3.5 core
NOTE: Excavation and earth work, sand cushioning, protection cover & GI pipe shall be measured and paid for separately.
Locating fault of LT underground cables any no. of core of size 6 -50 Sq. mm laid in trenches using fault locator machine and repairing the same by making LT joint ferrule etc. including necessary excavation & earth work upto 10 metre length, taking out the protection cover, sand and faulty cable and relaying the cable after necessary repair including refilling of sand and relaying of protection cover and RFR complete all as directed by Engineer-in- Charge. NOTES: (a) The quoted rate includes cost of arranging, shifting of fault locator machine including operator fee, T & P required, any number of times as and when required during the currency of contract. (b) The contractor will have to arrange the fault locating machine. In case contractor fails to diagnose/locate the fault within 04 Hrs of fault intimation, a penalty of Rs. 50/hour will be imposed/ levied. (c) LT joint will be measured and paid separately. (d) The qty catered will be executed different times during currency of work whenever fault occurs.
Cable joining kit (straight through cold shrinkable) for 1100 V (Earthed) grade cable complete with jointing material and accessories suitable for XPLE armoured aluminium conductor cable including taking down unserviceable termination complete all as specified of following size: -
25-50 Sq. mm, 3.5 to 4 core
70-95 Sq. mm, 3.5 core
120-185 Sq. mm, 3.5 core
Earthing with and including GI earth plate electrode 6 mm thick of size 600 mm x 600 mm with 32 X 6 mm GI strip earthing lead complete all as shown in electrical plate No. 3 and specified in Particular Specifications clause 19.14 of contract, IN REPAIR. NOTE: (a) The unit rate includes earthing lead and protection pipe upto 7.5 metre from top of earth plate. (b) Factory made PCC pit with cover shall be fixed at least 500 mm away from earth pit.
Automatic street light control panel 8 kw,32 Amp, 3 phase FR grade thermoplastic polycorbonate enclosure with hinged LID conforming to IP54 protection class 2 etc , IN REPLACEMENT, complete. Make:- Swadeep02EC8KW3P or equivalent make mentioned in Appndix 'B'.
LT panel board, outdoor type, CPRI approved all as specified in particular specifications of contract clause 19.15 including installation, commissioning & testing, IN REPLACEMENT, comprising the following components/acessories: - (a) Multifunctional meter electronic with suitable CTs, showing Amp, Volt, PF, HZ and other parameter rating Amp upto 300A & volt upto 500V -01 Set. (b) LED indicating lamp for R,Yand B phases-01set (set of three) (c) Internal power & control wiring with suitable size PVC insulated multistranded copper wire (d) Copper bus bar of 200 Amp capacity, 4 strip mounted on porcelain insulators. (e) MCCB 4 pole, 415 volt, 200 Amp, 25 kA -01 No. (Incomming) (f) MCCB 4 pole, 415 volt, 63 Amp, 16 kA - 02 Nos. (Outgoing).
LT panel board, outdoor type, CPRI approved all as specified in particular specifications of contract clause 19.15 including installation, commissioning & testing,IN REPLACEMENT, comprising the following components/acessories: - (a) Multifunctional meter electronic with suitable CTs, showing Amp, Volt, PF, HZ and other parameter rating Amp upto 300A & volt upto 500V -01 Set. (b) LED indicating lamp for R,Yand B phases-01set (set of three) (c) Internal power & control wiring with suitable size PVC insulated multistranded copper wire (d) Copper bus bar of 300 Amp capacity, 4 strip mounted on porcelain insulators. (e) MCCB 4 pole, 415 volt,315 Amp, 36 kA -01 No. (Incomming) (f) MCCB 4 pole, 415 volt, 100 Amp, 25 kA - 01 Nos. (Outgoing). (g) MCCB 4 pole, 415 volt, 63 Amp, 16 kA - 03 Nos. (Outgoing).
LT panel board, outdoor type, CPRI approved all as specified in particular specifications of contract clause 19.15 including installation, commissioning & testing, IN REPLACEMENT,comprising the following components/acessories: - (a) Multifunctional meter electronic with suitable CTs, showing Amp, Volt, PF, HZ and other parameter rating Amp upto 300A & volt upto 500V -01 Set. (b) LED indicating lamp for R,Yand B phases-01set (set of three) (c) Internal power & control wiring with suitable size PVC insulated multistranded copper wire (d) Copper bus bar of 300 Amp capacity, 4 strip mounted on porcelain insulators. (e) MCCB 4 pole, 415 volt, 250 Amp, 36 kA -01 No. (Incomming) (f) MCCB 4 pole, 415 volt, 160 Amp, 25 kA - 02 Nos. (Outgoing) (g) MCCB 4 pole, 415 volt, 100 Amp, 16 kA - 02 Nos. (Outgoing).
Taking shutdown from MES, disconnecting all electric connections and opening of LT panel of any description for repair etc., reassembling of the same after all necessary repair, refixing, replacement of unserviceable components, reconnecting, commisioning and testing to the entire satisfaction of Engineer-in-Charge. NOTE: Supply only spares/components will be measured and paid for separately under respective items of BoQ.
Supply only LED pilot lamp, RYB indication complete all as specified.
Supply only MCCB suitable for 415 volts AC supply, 50 Hz, 4 pole with over load and short circuit protection, adjustable thermal & adjustable magnetic release type, complete all as specified of rating: -
63 Amp, 16 kA.
100 Amp, 25 kA.
160 Amp, 25 kA.
200 Amp, 36 kA.
Cutting out existing worn out/ damaged CRCA sheet of LT panel board and providing new CRCA sheet of thickness not less than 2 mm including necessary welding, sheet metal repair work and applying a coat of anti corrosive primer after preparation of surfaces complete.
Making LT panel doors operateable to the entire satisfaction of Engineer-in-Charge by providing new hinges of existing size & pattern including necessary welding, sheet metal repair work and applying a coat of anti corrosive primer after preparation of surfaces and filling the undulation with ready made putty for MS/steel surfaces, complete.
Two coats of synthetic enamel paint applying a coat of anti corrosive primer after preparation of surfaces with spray gun including preparation of surfaces and filling the undulation with ready made putty for MS/steel surfaces and a coat of red oxide primer complete.
NOTES FOR SERIAL ITEM 12 TO 15: Repair work & painting to LT panel shall be carried out after taking necessary power shutdown from MES
NOTE: (i) To maintain utmost security at AF Station, contractor will arrange his workmen along with T&P in a manner that nonfunctional Fault of LT line & panel is made functional swiftly within 24 hour of receiving of complaint from the MES, during entire contract period. (ii) Not withstanding with the provision of "Compensation for Delay' envisaged under condition 50 of IAFW-2249, General Conditions of Contracts, additional compensation @ Rs. 500/- day will be charged from contractor in case he fails to make the LT line & panel functional to the entire satisfaction of Engineer-in-Charge within 24 hour of receiving of complaint from the MES regarding non working LT line & Panel.
M/s Sahib and Company
J.K & Company
MASTER CONSTRUCTION CO
siddharthenterprises
M/S Kuldip Construction Co.
BHARAT ENTERPRISES
NEW GURBINDER INDUSTRIES
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .