Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹32.0 LAccepted-AOC N A | NA | NA | 121004 | L1 | Accepted-AOC Lowest bidder | |
| 2 | L2₹33.8 L+₹1.3 L (3.92%)Rejected-Finance BHAGAT SINGH CHOWK SURATGARH 335804 DISTT SRIGANGANAGAR RAJ | GANGANAGAR | RAJASTHAN | 335804 | L2 | Rejected-Finance OTHER THAN LOWEST BIDDER | |
| 3 | L3₹35.5 L+₹2.9 L (8.97%)Rejected-Finance WARD NO 02 LAKHUWALI PO THE PILIBANGAN DISTT HANUMANGARH RAJASTHAN 335803 | HANUMANGARH | RAJASTHAN | 335803 | L3 | Rejected-Finance OTHER THAN LOWEST BIDDER | |
| 4 | L4₹37.7 L+₹5.1 L (15.6%)Rejected-Finance WARD NO 26 OLD 36 NEW NEAR FIRE BRIGADE OFFICE RCP TAL COLONY ROAD SURATGARH 335804 SRI GANGANAGAR RAJ | SURATGARH | SRI GANGANAGAR | RAJASTHAN | 335804 | L4 | Rejected-Finance OTHER THAN LOWEST BIDDER |
Tender Value
Refer Docs
EMD Value
₹84,860
Closing Date
3 Sept 2024, 6:00 pmClosed
Maj Uday Shankar Roy
GE AF Suratgarh
SPECIAL REPAIR TO INSTRUMENT ROOM AND TYRE BAY AT AF STN SURATGARH
2024_MES_659653_1
8180/E8
Open Tender
Civil Works
Item Rate
180 days
Suratgarh
As per Tender Documents
10 documents required · 10 mandatory
₹500
GE AF Suratgarh
₹84,860
Yes
30 Sept 2024
25 Jun 2024
5 Sept 2024
25 Jun 2024
3 Sept 2024
10 Jul 2024
Amount
BOQ (SPECIAL REPAIR TO INSTRUMENT ROOM AND TYRE BAY AT AF STN SURATGARH)
Dismantling of stone slabs and tiles of any description or thickness in floors, aprons etc laid, bedded and pointed in any type of mortar, complete all as specified and directed.
Dismantling of floors health or walls tiling and stone floor including cement mortar bedded (but not backing) & removing serviceable tiles to store and rubbish off the premises, complete all as specified and directed.
M&L for non skid ceramic coloured tiles of 7mm to 8mm thick, (square/rectangular) area of each tiles exc 0.11 sqm but not exc 0.18 sqm (including size 400mmx400mm), as in floors etc set & jointed in neat cement slurry and pointed in white or coloured cement to match the colour of tiles over and including screed bed or bedding layer of 15mm thick in CM 1:6, complete all as specified and directed.
M&L for Vitrified ceramic tiles 10mm thick (square/ rectangular) polished area of each tiles not exc 0.36 Sqm in floors etc., set and jointed in neat cement slurry and pointed in white or colour cement to match with and including screed bed or bedding layer of 15mm thick in CM (1:6), complete all as specified and directed.
M&L for Vitrified ceramic tiles 10mm thick (square/ rectangular) polished area of each tiles not exc 0.36 sqm in vertical surfaces such as skirting etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match with and including rendering 10mm thick in CM 1:4, complete all as specified and directed.
S&F for glazed ceramic tiles size 350mmx250 mmx7mm /450x350x7mm thick on vertical surfaces, set & joined in neat cement slurry and pointed in white or coloured cement to match the colour of tiles over and including rendering10mm thick in CM1:4 complete all as specified and directed by Engineer-in-charge.
M&L for 25mm thick granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window-cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite, complete all as specified and directed by Engineer-in-charge.
Demolition of cement concrete unreinforced in groundfloors and pavings not exc 15cm thickness below or above ground level etc, complete all as specified and directed.
M&L for 75mm thick PCC 1:4:8 type D-2 using 40mm graded stone aggregate as in sub bases, complete all as specified and directed.
M&L for machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658-2021 of 60mm thickness, M-35 Grade with grey cement and pigments, complete all as specified and directed by Engineer-in-charge.
M&L for 25mm thick sand filling under floors or in foundation including watering and consolidation. complete all as specified and directed.
Dismantling of brick tiles or terracing tiles sinlge layer on roofs, complete all as specified and directed.
Dismantling of mud in roofs, any thickness including plastering and leeping (whether full thickness removed or only a part there of) complete all as specified and directed.
M&L for wire brushing neat cement slurry with 3kg of cement per sqm at top and bottom of base coat and cleaning top surface, complete all as specified and directed.
M&L for PCC 1:2:4 type B1 (using 20mm graded stone aggregate) providing, cement concrete in kerbs of mud stops, rounded or chamfered on edges, complete all as specified and directed.
M&L for 50mm thick PCC 1:2:4 type B-1, (using 20mm graded stone aggregate) padding average to be provided in slope, complete all as specified and directed.
M&L for 10mm thick rendering on roof for laying in CM 1:4 waterproofing treatment, with using WPC , complete all as specified and directed. Note:-WPC will be measured and paid separately as supply only.
Supply only integral Waterproofing compound, complete all as specified and directed.
M&L for APP based polymeric membrane minimum weighting 3 Kg/Sqm and minimum 3mm thick reinforced with polyester non woven fabric (wt not less than 150 gms/sqm) laid over a tack coat of industrial bitumen 85/25 at the rate of 1.2 kg per sq.m including cleaning over primed surface, complete all as specified and as directed by Engr in Charge.
M&L for 40mm thick brick tiles laid on mud mortar and joints grouted flush in cement mortar (1:3) mixed with 5% of crude oil by weight of cement on mud phuska, complete all as specified and directed.
All as per ser item No 20.00 here in before but except tiles, complete all as specified and directed.
M&L for providing and injecting chemical emulsion for post constructional anti-termite treatment of soil under existing floors using emulsion @ one litre per litre per hole, 300mm apart including drilling and plugging 12mm dia holes with cement mortar 1:2 (1 cement :2 coarse sand) to match the existing floors, complete all as specified and directed.
M&L for providing and injecting chemical emulsion for Post constructional anti-termite treatment along the external wall below concrete or masonry apron using chemical emulsion @ 2.25 litres per linear metre including drilling and plugging holes etc. in apron, complete all as specified and directed.
Post construction treatment at points of contact of wood work by chemical emulsion (in oil or kerosene based solution) @ 0.50 ltr / hole by drilling 6mm dia. Hole at a down ward angle of 45 degree at 150mm centre to centre and sealing the same, complete all as specified and directed by Engr-In-Charge.
Taking down cement plaster on stone walls including raking out joints, hacking for key, scrubbing down with water, complete all as specified and directed.
M&L for rendering 10mm thick plaster on brick or concrete surfaces in cement mortor (1:6) finished the surface even and smooth without extra cement as internal surfaces of wall, complete all as specified and directed.
M&L for rendering 15mm thick on concrete or brick masonry surfaces or surface other than fair face of brickwork in CM 1:4 as in external surfaces of wall, complete all as specified and directed.
M&L for rough cast plaster over 10mm thick plaster in CM 1:6, complete all as specified and directed.
M&L for 5mm thick, rendering in CM 1:4 plaster on surfaces of ceiling and finishing the surface even and smooth without using extra cement, complete all as specified and directed.
M&L for preparation of newly plastered surfaces of walls/ceiling and applying two coats of oil bond distemper over a coat of 2mm thick wall putty, complete all as specified and directed.
M&L for applying two coats of exterior acrylic emulsion (weather proof treatment) over a coat of primer, in camouflaging patterns , including preparation of new surfaces like brooming down or steel wire brushing scraping down smoke soot, moulds mass and efflorescent salt and trading oil and greasy spots, complete all as specified and directed.
M&L for preparing old painted surfaces by washing, rubbing down and stopping of distempered and painted surfaces and applying two coats of oil bond distemper over 1.5mm thick one coat of wall putty surfaces of walls and ceiling complete all as specified and directed by Engineer-in-charge.
Taking down door chowkat or frame including shutter area not exc 1.50 sqm each and removing to store, complete all as specified and directed.
Taking down door chowkat or frame including shutter area exc 1.50 sqm and not exc 4.00 sqm, complete all as specified and directed.
S&F for solid PVC Door frame of size 50mmx47mm made out of 5mm plain colour PVC sheet reinforced with M.S square tube, in opening, complete all as specified and directed.
S&F for factory made solid panel PVC door shutter 30mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails, M.S. frame shall be covered with heat moulded plain colour PVC `C' channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles & plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S frame welded/ sealed to the stiles, & rails with suitable PVC sheet beading, & joined together with solvent cement, in the frame at site, complete all as specified and directed.
S&F for mild steel butt hinges medium weight 100mm size. mild steel cold rolled, complete all as specified and directed.
S&F for aluminium handle, cast type, anodiesed of size 150mm & fix to shutter, complete all as specified and directed by Engineer-in-Charge.
S&F for aluminium anodised, barrel tower bolt of extruded section and fix of length 150mm, complete all as specified and directed.
S&F for floor door stopper of aluminium 150mm size, complete all as specified and directed.
M&L for 75mm thick PCC 1:3:6 type C-2 (using 40mm graded stone aggregate) as in plinth protection flooring, complete all as specified and directed.
Dismantling of water tanks and removing to store capacity of tank exc 501 and not exc 1000 ltr, complete all as specified and directed.
S&F for rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR part-I ,500 ltr capacity including, 20mm dia ball brass valves, high pressure, with polyethylene float and fly nut complete, screwed for iron pipe or brass ferrule and fixed, complete all as specified and directed.
Taking up or down steel tubing and connections including cleaning for refixing or removal to store 15mm bore to walls, ceiling etc, complete all as specified and directed.
All as per ser item No. 44.00 here in before but 20mm dia pipe, complete all as specified and directed.
Cutting chases, pinning in, making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring, etc and making good, cutting not exc 10 cm girth, complete all as specified and directed.
S&F for medium grade GI tubing 15mm bore with all fittings , to walls, ceiling or laid in floors etc, complete all as specified and directed.
All as per ser item No. 47.00 here in before but in 20mm bore pipe, complete all as specified and directed.
S&F in repairs gun metal globe or gate valves with iron wheel head screwed both end for iron pipe and 15mm bore pipe, complete all as specified and directed.
S&F in repairs gun metal globe or gate valves with iron wheel head screwed both end for iron pipe and 20 mm bore pipe, complete all as specified and directed.
S&F in repairs stop cock copper alloy but fancy type and chrominum plated screwed down high pressure with crutch or butterfly handle screwed both ends for iron/pipe or for union and fixed 15mm bore, complete all as specified and directed.
S&F in repairs 15mm bore bib taps cast copper alloy chromoum plated fancy type with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule, complete all as specified and directed.
S&F in repairs Soap dish, any type, fixed to plugs with chromium plated brass screws, complete all as specified and directed.
S&F in repairs towel rail 600mm long of Brass C.P 'D' type fixed with and including chromium plated brass screws and wooden /plastic cleats, complete all as specified and directed.
M&L for solar control film 25 micron reflective type sticked to glass panes as per instructions of manufactures, complete all as specified and directed.
S&F 2 levers brass mortice lock vertical type, size 100mm including escutcheon plates and two keys complete all as specified and directed by Eng-in-Charge.
Demolition of wall ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/slabs/blankets, any thickness, including cover fillets, complete all as specified and directed.
S&F for designer gypsum ceiling board of size 595mm x595mmx12mm thick as in ceiling, fixed with screws on GI grid frame work of size 600mm x600mm, GI T-section of size 25mm x25mmx1.25mm, GI L-section 25mm x25mmx1.25 mm, hanging arrangements with roof with GI wire not less than 2.00mm dia, complete all as specified and directed by Engineer-in-Charge.
S&F for hangers 6mm dia GI (upto 1200mm length) adjusting level fixed to roof slabs by means of ceiling cleats made out of GI flat 40mmx3mm size 60mm long and expansion hold fasteners 12.5mm dia, 40mm long, complete all as specified and directed.
S&F for PVC (SWR) floor trap, plain with grating including jointing with solvent cement 75mm dia out let, complete all as specified and directed.
S&F for PVC (SWR) multi floor trap with grating including jointing with solvent cement 100mm dia out let, complete all as specified and directed.
S&F for PVC (SWR) pipes of 110mm dia, single socketed fixed to walls, complete all as specified and directed.
S&F for PVC (SWR) pipes of 75mm dia, single socket fixed to walls, complete all as specified and directed.
S&F for 100mm bore of pipe stack clamps out of 50mm by 5mm flat iron and 16mm dia round iron stays, including bolts and nuts and securing ends of stays to wall or roof, complete all as specified and directed.
S&F for PVC (SWR) bends of 110 mm dia, any radius, complete all as specified and directed.
S&F for PVC (SWR) vent cowl, 100mm dia, complete all as specified and directed.
M&L for brick work with subclass B bricks, straight or curved on plan exc 6 m mean radius in CM 1:6, complete all as specified and directed.
M&L for half brick works with sub class B bricks straight or curved on plan exc 6 m mean radius built in CM 1:4, complete all as specified and directed.
M&L for PCC 1:2:4 type B2 (using 40mm graded crushed stone aggregate) as in surface channels and drains etc, complete all as specified and directed.
Demolition of reinforced concrete of any description and in any position not other wise specifically provided, complete all as specified and directed.
Demolition of cement concrete bed in haunching and breaking up RCC drain pipes set in cement mortar of 150mm dia, complete all as specified and directed.
Excavating over areas not exc 1.5m deep getting out in soft/loose soil, complete all as specified and directed.
All as per ser item No 73.00 exc 1.5m and not exc 3 m deep, complete all as specified and directed.
All as per ser item No 73.00 exc 3m and not exc 4.5m deep, complete all as specified and directed.
M&L for concrete bed in PCC 1:4:8 type D2 (using 40mm graded stone aggregate) to drain pipes including packing under and haunching against the sides of the pipes after laying & testing for the 150mm dia, complete all as specified and directed. Note:- NP3/DCW pipe will be measured and paid seperetely.
M&L for reinforced concrete NP2 drain pipes 150mm dia pipes confirming to IS laid in trenches and jointed in CM 1:2, complete all as specified and directed.
M&L for cutting in to existing manhole for connectiing new drain 150mm bore, making good to pipe & rendering cutting out existing benching for & forming branch channel in PCC 1:2:4 type B1 smooth finished & reforming benching as required, complete all as specified and directed.
M&L for plain cement concrete 1:3:6 Type B1 using 20mm graded aggregate as in coping including form work etc, complete all as specified and directed.
M&L for precast cement concrete type B1 1:2:4 (using 20mm greded stone aggregate) as in manhole cover slab setting in C:M 1:6, complete all as specified and directed.
M&L for TMT bars 8mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips, complete all as specified and directed.
M&L for TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips, complete all as specified and directed.
Returning filling in soil including spreading, levelling and well ramming in layers not exc 25cm thick in layer etc, complete all as specified and directed.
Removing excavated material not exc. 50 m and depositing where directed at a level not exc. 1.5 m above the starting point, complete all as specified and directed.
S&F for vitreous china wash down water closet white with trap including connection to joint pipe, flushing pipe or Cistern, antisyphonage pipe, including making, etc complete including making good to floor etc, complete all as specified and directed,
S&F for vitreous China urinals, half stall (back or corner wall type), complete including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement; fixing automatic flushing cistern with brackets, flush pipe, grating and Union for discharge pipe. (Exclusive of fixing supply pipe to flushing cistern, trap and waste pipe), complete all as specified and directed.
S&F for tubular towel rail brass chromium plated, 20mm dia, D type, 60cm long between flanges, complete all as specified and directed. complete all as specified and directed.
S&F for chromium plated shower roses with or without swivel joints, 125mm dia suitable for 15mm pipe, complete all as specified and directed.
S&F for PVC connection 15mm size, 450mm long with PTMT nuts both side, complete all as specified and directed.
S&F 15mm Stop valve angle cock fancy type, chromium plated with long shunk and cup (concealed type) high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for union, complete all as specified and directed.
S&F 15mm cast copper alloy, chromium plated bib taps fancy type with crutch or butterfly handle, screwed for iron pipe or for brass ferrule, complete all as specified and directed.
S&F for 10 ltrs capacity PVC valveless, syphonic action type, flushing cistern with PVC flush pipe 32mm dia, low level, white, with inlet ball valve, float and handle including brackets, complete all as specified and directed.
S&F for vitreous china wash hand basin oval type, CP swan neck pillar tap ,waste coupling etc, complete all as specified and directed.
S&F for PVC waste pipe 32mm dia 80cm long with socket, complete all as specified and directed.
M&L for cleaning of RCC surfaces by using steel brushes then loosing the rust by using B11 chemical of pedilite (Dilute folic acid) or equivalent complete all as specified and directed by Engineer in charge.
M&L for washing the reinforcement with distilled water (PH value 7) by using pressure jet machine, complete all as specified and directed by Engineer in charge.
M&L for repairing of distorted concrete in slab / beams /lintels / slab projections /chhajjas/columns etc. up to a depth not exc depth of 100mm of surface using (Pedilite / Nitocold) tapecrete cementous polymer modified chemical as per manufacturers instructions, complete all as specified and directed by Engineer in charge.
M&L for guniting work to RCC work in columns , beams , chajjas, balconies , slabs , landings and roof projection etc by removing loose concrete using adhesive plaster of grade 1:3.25 (01 part of cement and 3.25 part of coarse sand ) with a average thickness of 50 mm and making the surface even and smooth including mixing plasticiser as per manifacturers instructions of Make Sika / Fos Roc / Pidilite / Bostrik / Make as approved. The adhesive plaster is to be placed by pressure gunitting nozzle using gunitting plant providing gunitting pressure @ 2.50 kg/Sqm including fixing of welded wire mesh fabric of wire not less than 95mmx95mmx3mm including all necessary formwork / scaffolding and making the surfaces even smooth by using 5 mm thick cement mortar plaster in CM (1:3), complete all as specified and directed by Engineer in charge.
M&L for reinforcement of 8mm dia TMT bar as in repairs, welded at the rate of 0.60 m C/C embedded 75 mm at each end into existing beam using hilty chemical or equivalent, complete all as specified and directed by Engr in charge.
M&L for reinforcement of 10mm dia and above TMT bar as in repairs, welded in columns, beams etc embedded 75mm at each end into existing wall and any RCC me,mbers using hilty chemical or equivalent complete all as specified and directed by Engr in charge.
Providing and fixing Powder coated aluminium (minimum thickness of powder coating 50 micron) work for doors, Windows ( sliding two or three track / openable), ventilators and partitions (Fixed portions) with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket, handle ,lock, etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ paneling, C.P. brass/ stainless steel screws, complete all as specified and directed by Engr-in-Charge
S&F for 4.8mm thick sheet glass, ordinary quality and in square exc 0.5 sqm in each pane in any position complete all as specified and directed.
S&F in repair door closer hydraulically regulated, design No 3 universal type suitable for door shutter 851 mm to 1000 mm in width and of weight 61 to 80 Kg each cast iron body, complete all as specified and directed.
S&F for forsted sheet glass 3 mm thick, ordinary quality and glazing with oil putty (in metal frames etc) in squares not exceeding 0.5 sqm in each pane, complete all as specified and directed.
S&F for stainless steel wire cloth, 0.36mm nominal dia of wire and average width of aperture 1.40 mm and fixed with stainless steel wire staples, complete all as specified and directed.
S&F for aluminium chequered grills as on aluminium windows, weight not exc .0.50 kg/sqm and fixed including taking down of old unservicable grill, complete all as specified and directed. by the Engineer in charge.
M&L for machine cut kota stone slab 18mm to 20mm thick as in flooring / stair case landing, laid over and including 15mm thick cement screed base in CM 1:6 and jointed with grey cement slurry mixed with pigment to match the shade of slab including rubbing and mirror polishing, complete all as specified and directed.
M&L for PCC 1:4:8 type D2 (using 40mm graded stone aggregate) as in foundation , filling and mass concrete complete all as specified and as directed by the Engr-in-Charge.
M&L for hardcore of broken bricks in loose filling with aggregates of gauge 80mm to 150mm in soakage pits, soakage wells, complete all as specified and directed.
M&L for RCC beams, cantilevers, slab, bressummers, lintels over 1.5m span in 1:2:4 type B1 (using 20mm graded aggregate) complete all as specified and directed.
Use and waste of formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilever, shelves including sup-ports, overhangs etc also splays between floors and beams etc complete flat in rough finished surfaces of concrete, complete all as specified and directed.
Use and waste of formwork to edges of concrete flats, treads, breaks in floors,window cills, concrete railings,openings in concretewalls, floor and roofs n exc 20 cm wide and sides of RCC/PCC bands in walls, horizontal sloping and similarwork exc 5cm but not exc 10cm, complete all as specified and directed.
M&L for 150mm internal bore dia Double wall corrugated PE pipes laid in trenches and jointed and testing complete with all necessary hardware, complete all as specified and directed.
S&F for 8mm thick hollow printed coloured PVC sheet wall lining/panelling including frame work (sample kept in GE office) made of 1mm thick PVC sheet in strips and channels feathered at the edges for fixing of wall lining inclusive of solvent cement and fixing at site , complete all as specified and directed by the Engineer-in-Charge
Surface excavation not exc 30cm deep and averaging 15cm deep in soft/loose soil and getting out, complete all as specified and directed
M&L for RCC, 1:2:4, type B1 (using 20 mm graded stone aggregate) Precast cement concrete cover slab for manhole and similar article with plain face, set in cement mortar 1:4 complete all as specified and direceted.
Taking down DB/main switch of any size and making good disturbed surface of wall/floor, complete all as specified and directed Note - Temporary power supply shall be provided by contractor.
Taking down unsv submain wiring aluminium/copper etc and making good the disturbed surfaces of walls/ floor etc matching with the existing surface, complete all as specified and directed Note :- Temporary power supply shall be provided by contractor.
Taking down carefully aluminum point wiring (light, fans, socket etc) complete including battens and fittings such as switch, ceiling rose, light fittings, regulators, socket, etc. and making good disturbed surface of wall/floor, etc. complete all as specified and directed Note :- Temporary power supply shall be provided by contractor.
M & L for point wiring (concealed) complete with FRLS PVC insulated unsheathed 1100 Volts grade, conforming to IS-694, 1.5 sq mm (nominal area) multi stranded copper conductor cable drawn though in and including non metallic medium grade rigid PVC conduit accessories, ISI marked, 19/20 mm dia including all accessories, concealed in walls/floors/ceilings etc by cutting chases using machine and making good the disturbed surface, with and including sunken type pressed steel/welded MS terminal box 1.2 mm thick bakelite laminated sheet top cover 3 mm thick and 1.5 sq mm copper earth continuity wire connected to earth dolly complete for the following complete all as specified and as directed by Engr-in-charge.
One light/fan/exhaust fan point controlled by by one switch, complete all as specified and directed.
One switch socket outlet 3 pin 6 amp on same board, complete all as specified and directed.
All as per ser item No 120.00 above here in before but 1.5 sqmm cable size and 1.5 sqmm earth continuity wire for one 3 pin socket outlet, 5 amps on Independent board, complete all as specified and directed.
All as per ser item No 120.00 here in before but with 2.5 sqmm FRLS copper cable for one 15/5 Amps Multipurpose power point.Including 2.5 Sqmm FRLS copper conductor cable for earth continuity conductor and connecting it to earth, complete all as specified and directed.
All as per ser item No 120.00 above here in before but 4 sqmm cable size with 4 sqmm earth continuity wire for one 3 pin socket outlet, 15 Amps on independent board.(AC/Geyser) complete all as specified and directed.
S&F for 5 Amp switch piano, flush type single pole one way, complete all as specified and directed.
S&F for socket flush type 6 amps, 5 pin, 230v, complete all as specified and directed.
S&F for switch socket combination multipurpose 2-in-1 flush type 3 pin 16 amps and 3 pin 6 amps, 230v incl dismentling taking down unsv one, complete all as specified and directed.
S&F for stepped type (0-4 step) electronic regulator for ceiling fan 1200 mm, 240 volts, 100 Watts, single pole, including connecting, testing, complete all as specified and directed.
S&F for ceiling rose surface bakelite three terminal, complete all as specified and directed.
S&F for LED batten fitting ' 2'long, 10 watt,CDL 230 Volts , decorative ultra slim square profile LED lighting fixture with extruded polycarbonate. The luminarie should have a color temperature of 3000K complete with all accssories internally pre wired and including connecting up to ceiling rose with 0.5 sqmm two core copper flexible conductor cable with mounting casing box 2 nos including dismentling taking down unsv fitting any type, complete all as specified and directed.
S&F for LED fitting, 20 watt, CDL, 230 Volts, 4 feet long , decorative ultra slim square profile LED lighting fixture with extruded polycarbonate. The luminarie should have a color temperature of 6500K complete with all accssories internally pre wired and including connecting up to ceiling rose with 0.5 sqmm twin core copper flexible conductor cable incl LED lamp and mounting casing box 2 nos including dismentling taking down unsv fitting any type, complete all as specified and directed.
S&F for LED 2'x2' size backelite panel light 36 Watt environmental friendly, new generation, aesthetically designed, ultra modern recess mounting luminaries with high brightness SMD LEDs as light source 28 Watt with nominal system lumen output of 2800 lumens and a minimum system efficiancy of 100 lm/W. The luminarie shall have a rated system lifetime of 50,000 burning hours at L70. The luminarie should have a color temperature of 6500K and CRI > 70. The luminarie shall meet IP 66 rating and IK 09 rating with THD < 20% and PF >0.9, complete all as specified and directed.
S&F for LED building security light 30 watt, 230V with lens and toughened glass top.The luminarie should have a color temperature of 6500K, IP 65 complete PF > 0.95 with all accessories and including connecting up to ceiling rose with 0.5 sqmm three core copper flexible conductor cable, One GI medium grade 20/25 mm dia bracket of total length 50 cm and fixed to wall with 2 Nos MS Clamp and fastener, complete all as specified and directed.
S&F for PVC body Exhaust fan, 250mm sweep, AC, single phase complete with all accessories and electric connection including making necessary holes in walls, complete all as specified and directed.
M&L for submain wiring with two single core PVC insulated unsheathed 1100 volt grade multi stranded FRLSH Copper conductor cable of size 1.5 sqmm (Nominal area) drawn through in and including non metallic medium grade rigid PVC conduit accessories, ISI marked, 19/20 mm dia including all accessories, concealed in walls/floors/ceilings etc by cutting chases using machine and making good the disturbed surface, size with all fittings and accessories alongwith one single core green colour PVC insulated unsheathed 1100 volt grade multi stranded FRLSH Copper conductor cable of size 1.5 sqmm as earth lead and connected to earth dolly and making good to disturbed surfaces, complete all as specified and directed. NOTE: (a) Two run of cable with one run of earth wire and one run of conduit will be measured as one length.
M&L for submain wiring with two single core PVC insulated unsheathed 1100 volt grade multi stranded FRLSH Copper conductor cable of size 6.00 sqmm (Nominal area) drawn through in and including non metallic medium grade rigid PVC conduit accessories, ISI marked, 19/20 mm dia including all accessories, concealed in walls/floors/ceilings etc by cutting chases using machine and making good the disturbed surface, size with all fittings and accessories alongwith one single core green colour PVC insulated unsheathed 1100 volt grade multi stranded FRLSH Copper conductor cable of size 6.00 sqmm as earth lead and connected to earth dolly and making good to disturbed surfaces, complete all as specified and directed. NOTE: (a) Two run of cable with one run of earth wire and one run of conduit will be measured as one length.
M&L for submain wiring with four single core PVC insulated unsheathed 1100 volt grade multi stranded FRLSH Copper conductor cable of size 10 sqmm (Nominal area) drawn through in and including non metallic medium grade rigid PVC conduit accessories, ISI marked, 19/20 mm dia including all accessories, concealed in walls/floors/ceilings etc by cutting chases using machine and making good the disturbed surface, size with all fittings and accessories alongwith one single core green colour PVC insulated unsheathed 1100 volt grade multi stranded FRLSH Copper conductor cable of size 10 sqmm as earth lead and connected to earth dolly and making good to disturbed surfaces complete all as specified and directed. NOTE:-Four runs of cable with one run of earth wire and one run of conduit will be measured as one length.
S&F for electric water heater (GEYSER), storage type steel body with copper inner tank and heating element upto 2 KW capacity 25 litre, BEE 5 Star rated complete with all accessories such as safety valve, thermostate, NRV, connection piece etc single phase AC 240 Volts, 50 Hz including connecting cable with Plug top one, complete all as specified and directed. Note. Unserviceable geyser to be deposited to E&M Store Yard .
S&F for sheet metal vertical TPN double door DB, IP 43 protection, 4 Way, 415 Volt, TPN with 200 Amps rated bus bar and with neutral, earthing bar complete mounting of 4 pole MCCB 125 Amps, 16 KA, DPX 160 series as incoming and MCB's TP 63 Amps, 10 KA - 3 Nos as out Going and fixed complete all as specified and directed. Note:- MCCB & MCB paid to be separately.
S&F for sheet metal TPN single door DB one Way IP 43 protection, 415 Volt, fixed in MCB TPN 6A-32Amp Amps, complete all as specified and directed. Note:-MCB paid to be separately.
S&F for MCB distribution board, IP 43 protection, double door, metal enclosure, SPN, 230 Volts, 8 way with 200 Amps rated bus bar and with neutral, earthing bar, complete all as specified and directed.
S&F for MCB distribution board, IP 43 protection, Single door, metal enclosure, SPN, 230 Volts, 4 way with 200 Amps rated bus bar and with neutral, earthing bar complete all as specified and directed.
S&F for sheet metal enclosure with socket plug top single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB of 20 amps , 240 Volts, complete all as specified and directed.
S&F for sheet metal single door DB 4 Way, 415 Volt, 100 Amps rated bus bar chamber made of ETP Grade copper, complete all as specified and directed.
S&F for MCCB four pole 125 Amps with breaking capacity 16KA , 415 Volts, thermal & magnetic release including making all incoming/ outgoing connections outgoing electrical connection with suitable size of copper lugs etc. complete all as specified and directed by Engineer in Charge.
S&F for MCB TP (three poles), 63 Amps, breaking capacity 10 KA 'C' curve confirming to IS-8828, 240 volts, 50 HZ including making necessary incoming and outgoing electrical connection with suitable size of copper lugs etc, complete all as specified and directed.
S&F for MCB TPN four poles, 6 to 32 Amps, breaking capacity 10 KA 'C' curve confirming to IS-8828, 240 volts, 50 HZ including making necessary incoming and outgoing electrical connection with suitable size of copper lugs etc, complete all as specified and directed.
S&F for MCB, SPN 6 to 32 amps, 415 Volts, 10 KA breaking cap, ‘’C” curve confirming to IS-8828, 240 volts, 50 HZ including making necessary incoming and outgoing electrical connection with suitable size of copper lugs etc, complete all as specified and directed.
S&F for MCB, Single Pole, 6 to 32 amps, 240 Volts, 10 KA breaking cap, ‘’C” curve confirming to IS-8828, 240 volts, 50 HZ including making necessary incoming and outgoing electrical connection with suitable size of copper lugs etc, complete all as specified and directed.
M&L for earthing with Galvanised Steel earth plate electrode 60cm x 60cm x 6mm thick buried directly in ground vertically at a depth not less than 2.25metre below normal ground level with top edge of earth plate at a depth not less than 1.5 metre below normal ground level, earth plate surrounded from all sides by 15cm thick packed layer of charcoal dust and common salt filling in alternate layers and electrode connections by using GI wire 4mm as earthing lead (upto the body of the equipment) by means of bolts, nuts, check nuts and washers made of galvanised iron and thimbles and protected by light grade 40mm dia GI pipe connected up to main DB/LT Panel /Test point and GI pipe medium grade 20mm bore for watering and including funnel , wire mesh , RCC pit cover and PCC chamber pit with PCC (1:3:6) type C-2 using 40mm graded stone aggregate, including excavation and earth work in any type of soil , returning , filling in approved soil and disposal of surplus soil to a distance not exceeding 50m all as specified and shown in electrical plate No 3 of SSR 2009 (Part-I) complete all as specified and directed.
Taking down Ceiling fans of any sweep and any size including cable connections and disconnecting of fan blades and removing the fan with blades deposit to store yard as it is in working condition for further hanging in its original position or any other position including as per direction of Engineer-in-Charge including it's fitting and fixtures after carrying out service includes cleaning, greasing and oiling, painting of fan with one coat of synthetic enamel spraying painting including marking of MES number with black paint after preparation of surface reassembling the fan etc including testing complete all as specified and as directed by Engr- in-charge. Note :- Any damage has to be made good by the contractor to make the item functional after testing.
Supply and lay LT UG cable 3.5 core 70 sqmm XLPE insulated armoured 1100 Volts grade heavy duty cable with PVC insulated stranded aluminium conductor laid in trenches, complete all as specified and directed.
S&F for GI tubing light grade 40mm bore on pole /wall with necessary clamps,nuts,bolts and washers/under road cross ISI marked, for cable protection, complete all as specified and directed.
Supply only HDPE Double wall corrugated pipe (DWC) confirming to IS-14930 (Part-II) of size 63mm including snap fit coupler as required for cable protection, complete all as specified and directed.
Excavation of road cutting by manually including making good to disturb surface after the completion of work with PCC 1:2:4 type B2 on top not less than 150mm thick including levelling and cambering according to existing road surface, refilling, watering, ramming etc, complete all as specefied and directed.
Material & labour for earthing with Galvanised Steel earth plate electrode 60cm x 60cm x 6mm thick buried directly in ground vertically at a depth not less than 2.25metre below normal ground level with top edge of earth plate at a depth not less than 1.5 m below normal ground level, earth plate surrounded from all sides by 15cm thick packed layer of charcoal dust and common salt filling in alternate layers and electrode connections by using Galvanised Iron strip of 25×4mm as earthing lead (upto the body of the equipment) by means of bolts, nuts, check nuts and washers made of galvanised iron and thimbles and protected by light grade 40mm dia GI pipe connected up to main DB/LT Panel /Test point and GI pipe medium grade 20mm bore for watering and including funnel , wire mesh , RCC pit cover and PCC chamber pit with PCC (1:3:6) type C-2 using 40mm graded stone aggregate, including excavation and earth work in any type of soil , returning , filling in approved soil and disposal of surplus soil to a distance not exceeding 50m all as specified and shown in electrical plate No 3 of SSR 2009 (Part-I) complete all as specified and directed. Note : GI strip and protection pipes 40 mm GI light grade up to 7.5 metre is included in unit rate.
Supply, install, commissioning and testing of commercial Air curtain unit for prevention of dust and conditioned air losses, single phase, 220 V, 50 HZ, made out of MS/CRCA sheet of minimum thickness 18 gauge finished with two coats of red oxide primer and final coat of synthetic enamel paint (oven baked) with MS - CRC 18 gauge square perforated suction grills, Aluminium alloy fans and single phase electric motor, nozzles etc, and door opening size 70" x 78" complete with fittings and accessories so as to produce 1 - 1.5 m/sec air velocity at floor level for door opening as specified and directed by Engineer in Charge.
Supply , assembly and erection of GI sheet with TDF flange rectangular/square duct made out of 'L' shaped hollow profile, duly factory boxed, incl all accessories such as Corner, Cleat, Carriage bolt, Gasket and appropriate sealant on longitudinal joints etc complete of size 24 Gauge, complete all as specified and directed by Engineer in Charge
M&L for duct insulation with resin bonded fibre glass wool roll of density 24 kg/Cum, with factory laminated aluminium vapour barrier, 50mm thickness of insulation as specified and including the following all as specified and directed by Engineer in Charge:- → (a) M&L for cleaning the duct surface (to be insulated ) by scrapping carefully with wire brush etc. to make the surface completely free of millscale, dirt, dust, grease and other foreign materials, taking special care so that all duct joints are sealed against any leakage. (b) M&L for applying rubber based adhesive CPRX compound. (c) M&L for sealing of all longitudinal joints and circular overlaps with and including Aluminium foil tape 50 mm wide,to make the insulation leakproof. (d) M&L for securing the insulation with and including mechanically fastened nylon/steel straps of size 12 mm/50 mm at maximum intervals of 1.2 mtr.
Excavation in trenches not exc 1.5m deep and not exc 1.5m wide in manholes laying of cable etc. and getting out any type of soil, complete all as specified and directed.
Contract Amount shall be derived after deducting the amount of Schedule of Credit in General Summary on serial page No 17(R) of tender documents.
M/S Shree Ram Enterprises (BID ID -3073240)
Gill Construction Co (BID ID -3064373)
M/s Shubham Enterprises (BID ID -3073515)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .