Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹18.3 LAccepted-AOC 172 SHANIWAR PETH TRIMBAKESHWAR SOCIETY OFF SHANIWAR WADA PUNE 411030 PUNE CITY MAHARASHTRA 411030 INDIA | PUNE | MAHARASHTRA | 411030 | ₹18.3 L | 1 | Accepted-AOC Lowest 1 Bidder |
| 2 | 2₹21.1 L+₹2.7 L (15.0%)Rejected-AOC | ₹21.1 L+₹2.7 L (15.0%) | 2 | Rejected-AOC Not the lowest 1 Bidder |
Tender Value
₹21.4 L
EMD Value
₹42,836
Closing Date
24 Apr 2025, 3:00 pmClosed
Principal Technical officer
CSIR NCL Pune 411008
Replacement of Roof Top Solar water heating system at GJ Hostel and SITC of Roof Top solar water heating system at HR II Hostel at CSIR NC
2025_CSIR_232389_1
Elect/ GJ and HRII Solar water Heating/25-26/01
Open Tender
Electrical Works
Works
90 days
CSIR NCL Pune
As per NIT
3 documents required · 3 mandatory
₹500
Director NCL Pune
₹42,836
20 Jun 2025
9 Apr 2025
25 Apr 2025
9 Apr 2025
24 Apr 2025
9 Apr 2025
9 Apr 2025 - 24 Apr 2025
Amount
Supply & Installation Testing and commissioning of 500LPD ETC typeSolar Water heating system with Heating coil, non pressurized thermo siphon 58x2100mm ETC tubes with INTIGRATED GI with glass line coating hot water storage tank of Stainless Steel 2mm thickness and MS powder coated Stand as per MNRE specifications complete with 5 years warantee of UNIVERSUN/ SUDARSHAN/ASHIRWAD make.
Supplying & Erecting 40mm dia 3.4mm minimum thickness Polyethylene Composite pipe, confirming to IS15450:2004 duly joined by compression/crimp fitted accessories, with internal as well as external end sealing arrangement for solar water heater system as per specifion.(1 1/2") inch Composite pipe of Kitec/Unipro make.
Supplying & Erecting 32mm dia 2.8mm minimum thickness Polyethylene Composite pipe, confirming to IS15450:2004 duly joined by compression/crimp fitted accessories, with internal as well as external end sealing arrangement for solar water heater systemas per specifion.1 1/4" inch Composite pipe of Kitec/Unipro make.
Supplying & Erecting 25mm dia 2.45mm minimum thickness Polyethylene Composite pipe, confirming to IS15450:2004 duly joined by compression/crimp fitted accessories, with internal as well as external end sealing arrangement for solar water heater systemas per specifion1" inch Composite pipe
Supplying & Erecting 20mm dia 2.00mm minimum thickness Polyethylene Composite pipe, confirming to IS15450:2004 duly joined by compression/crimp fitted accessories, with internal as well as external end sealing arrangement for solar water heater systemas per specifion3/4" inch Composite pipe of Kitec/Unipro make.
Supplying & Erecting 16mm dia 1.75mm minimum thickness Polyethylene Composite pipe, confirming to IS15450:2004 duly joined by compression/crimp fitted accessories, with internal as well as external end sealing arrangement for solar water heater systemas per specifion. 1/2" inch Composite pipe of Kitec/Unipro make.
Supplying & Erecting Elestomeric Nitrile rubber/Foam tube type sleeves for coating & insulating on provided Polyethylene Composite pipe having 9mmthickness and inner diameter 42mm for solar water heater system.
Supplying & Erecting Elestomeric Nitrile rubber/Foam tube type sleeves for coating & insulating on provided Polyethylene Composite pipe having 9mmthickness and inner diameter 32mm for solar water heater system.
Supplying & Erecting Elestomeric Nitrile rubber/Foam tube type sleeves for coating & insulating on provided Polyethylene Composite pipe having 9mmthickness and inner diameter 28mm for solar water heater system.
Supplying & Erecting Elestomeric Nitrile rubber/Foam tube type sleeves for coating & insulating on provided Polyethylene Composite pipe having 9mmthickness and inner diameter 22mm for solar water heater system.
Supplying & Erecting Elestomeric Nitrile rubber/Foam tube type sleeves for coating & insulating on provided Polyethylene Composite pipe having 9mmthickness and inner diameter 19mm for solar water heater system.
Supply Installation , Testing & Commissioning, 1 1/4" Ball Valve with ISI standards of Zoloto/Snap/Parco make.
Supply Installation , Testing & Commissioning, 1" Ball Valve with ISI standards of Zoloto/Snap/Parco make.
Supply Installation , Testing & Commissioning of 1 1/4" Non Return Valve with ISI standards of Zoloto/Snap/Parco make.
Supply Installation , Testing & Commissioning of 1 " Non Return Valve with ISI standards of Zoloto/Snap/Parco make.
Supply Installation , Testing & Commissioning of 1/2 " Non Return Valve with ISI standards of Zoloto/Snap/Parco make.
Supply Installatio , Testing & Commissioning 1/2” Hot water taps as per ISI standards Jaquar/Kohler make.
Supply & Installation GI Pipe "B" Class with GI fittings, pipes for system & venting, other minor accessories like elbow, union, Tee, barrel nipple, FTA, & teflon tape etc.
Supply & Installation of Fabricated stand made out of MS angle 35mmx35mm duly painted with two coats of red oxide & two coats of enamel paint for 1500LPD cold water tank.
Supply & Installation of Fabricated stand made out of MS angle 35mmx35mm duly painted with two coats of red oxide & two coats of enamel paint for 1000LPD cold water tank.
Supply & installation of Sintex type triple layer cold water tank of capacity 1500Ltrs on the provided MS angle stand.
Supply & installation of Sintex type triple layer cold water tank of capacity 1000Ltrs on the provided MS angle stand.
Dismantling the existing solar water heating system upto 500 LPD capacityalong with piping etc. from roof top and bringing down to ground.
Supplying & fixing completely assembled MDS make main Power VTPN distribution board, 3 phase 4way with 4 pole Lexic make MCB 63A cat No608702--1No as incomer & 12Nos of 6-20A SPMCBs Lexic make as O\G. The distribution box should be fixed on wall with Anchor fastners. Enclosure should be double door type with IP 43 potection Legrand make,Cat No.507725 with cable end boxes. Rate is inclusive of Lexic make metal enclosure,MCBs & cable end boxes. (For Heaters in Solar tank at GJ Hostel)
Supplying & fixing on T.W. Board Main SPN Distribution board Legrand Ekinox make 8 way cat no:507611 with3 no. of Legrand make DP MCB 40 A, 10KA breaking capacity as I/C & 3 nos of RCCB 2 pole 16/25A as O/G. Rate is inclusive of enclosure, MCBs & connections. Separate Connector should be provided for neutral & Earthing.(For Heaters in Solar tank)
Supplying & laying on wall/cable tray PVC armoured cable, 3.5 core x 35sqmm, Polycab /Gloster /Asian Make, Aluminium conductor, 1.1Kv grade at NCL site. (Before supplying cable, actual measurement at site should be taken in consultation with site engineer.) The cable should be fixed to the tray with M.S. screws.
Supplying & laying on wall/ cable tray PVC armoured cable, 2 core x 4sqmm, Polycab /Gloster /Asian Make, copper conductor, 1.1Kv grade at NCL site. (Before supplying cable, actual measurement at site should be taken in consultation with site engineer.) The cable should be fixed to the tray with M.S. screws.(Heaters in Solar Tank)
Termination of 3.5 core, 35 Sqmm Akuminium conductor armoured cable with suitable size of Aluminium crimping type lugs into the existing power DB and other end into load. The siemens type cable gland should be used for termination of cable
Termination of 2 core, 4 Sqmm Copper conductor armoured cable with suitable size of Copper crimping type lugs into the existing power DB and other end into load. The siemens type cable gland should be used for termination of cable
Apex Industries (BID ID -844029)
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .