Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹19.9 LAccepted-AOC | L1 | Accepted-AOC being L1 | |
| 2 | L2₹23.5 L+₹2.0 L (9.52%)Rejected-AOC | L2 | Rejected-AOC OTHER THAN L1 | |
| 3 | Rejected-Technical | - | Rejected-Technical NO in WLR of QE Dec 23 by CEPZ |
Tender Value
₹19.9 L
EMD Value
₹40,000
Closing Date
3 Apr 2024, 9:00 amClosed
Lt Col Anurag Anand
HQ 135 WORKS ENGINEER
REPAIR/ MAINT OF 33/11 KV GRID STATION INCL MAINT OF 11 KV NETWORK AT RAKHMUTHI UNDER GE (S) AKHNOOR
2024_MES_637077_2
CWE/JA-37/2023-24
Open Tender
Electrical and Maintenance Works
Works
180 days
RAKHMUTHI AKHNOOR
AS PER TENDER DOCUMENTS
9 documents required · 9 mandatory
₹500
GE SOUTH AKHNOOR
₹40,000
Yes
4 Sept 2024
1 Mar 2024
10 Apr 2024
1 Mar 2024
3 Apr 2024
15 Mar 2024
1 Mar 2024 - 14 Mar 2024
Amount
Complete overhauling and servicing of 33 KV outdoor type VCB including disassembly of operating mechanism parts, spring charging motor and mechanism well cleaning with petrol and CRC-226, replacing unserviceable parts/accessories oiling and greasing of moving parts, dismantling checking and well cleaning of pole insulator, checking of vacuum interrupters, well cleaning mechanism linkages drive insulators and fiber reinforced plastic frame around the vacuum interrupters including routine and periodical test, complete all as specified and directed by Engineer-in-Charge. (Note : Supply only spares will be measured and paid separately)
Supply only the following spares of VCBs and connected control and switchgear accessories.
Supply only spring charging motor with gear and connector for VCB of voltage 30 Volts DC or as required at site compatible with OD VCB
Supply only Closing and tripping coil for SF6/VCB as per site requirements.
Supply only Auxillary switch for 33/11 VCB as per site requirements.
Supply only Limit switch for 33 KV VCB as per site requirements.
Supply only Hooter suitable for 33/11 KV breaker
Supply only T&C switch with locking arrangement.suitable for 33 KV breaker
Supply only LED Indicating lamps of desired colour dual input type.
Supply only Vaccum Interrupting unit (bottle type) suitable for SF 6 breaker
Supply only Control Cable 8 core armoured control 2.5 sqmm copper for interconnecting from remote panel to VCB outdooor unit all as directed
Supply only Control cable 4 core armoured control cable 2.5 sqmm copper for interconnecting from remote panel to VCB outdooor unit.
Supply and fixing new CT outdoor type oil immersed ratio 75-50/5+5A (three core type) Class I & 5P10 VA Burden-15 with first oil filled suitable for 33 KV power supply by providing suitable size of nuts, bolts on existing structure complete including taking out old unserviceable CTs, complete all as specified and directed by Engineer-in-Charge. Make-Jyoti(JSL)/Gyro/Laxmi/ Areva, schneider
Supply, fixing, commissioning and testing of 33000 x 110 volts / √3 outdoor type single pole potential transformer and self air cooled type having 200 VA burden suitable for metering of equipment installed on existing structure with suitable fixing arrangement including dismantling of old PTs, complete all as specified and directed by Engineer-in-Charge. Make : Huphen, Areva, schneider
Supply and fixing in replacement of 33 KV rotating , horizontal type, isolator switch 400 Amp complete with all fixing arrangements after disconnecting all electric connections, and keeping aside for offering credits, complete all as specified and directed by Engineer-in-Charge.
M&L for scrapping laid out aggregate of any size and removing from site and cleaning of dirt and vegetation from site and relaying of the same in switchyards, complete all as specified and directed by Engineer-in-Charge.
Preparation of iron fencing complete 33 KV grid including gates of iron gates by scrapping of rusted materials, and painting with two coats of aluminium paint of approved make and colour, complete all as specified and directed by Engineer-in-Charge.
M&L for painting of HT 33 KV HT grid steel structure including all MS channel isolators, CTs, PTs and MOCBs, VCBs, bus bar and other steel structure with synthetic enamelled aluminium paint on structure abd other colour code for equipment after proper surface preparation, complete all as specified and directed by Engineer-in-Charge.
M&L for Jumpers works in PTs, CTs, MOCBs, isolator, DO fuse by using parallel grove clamp, Tee clamp Tee clamps other connectors required by using ACSR conductor any sizess (Dog/Mouse) including dismantling old conductor and clamp all as specified and as directed by Engr in charge
M&L for repalcement of PG clamps, parallel grove clamps, tee clamps, GI nuts bolts of required size other connectors for connecting ACSR conductor for jumpering all as specified and as directed by Engr in charge
M&L for earthing complete with galvanised steel earth plate electrode 600x600x6mm thick burried directly in ground /earth pit not less than 2.25m deep below the ground level with top edge of the plate not less than 1.5 m below the normal ground level connected to DB/Panel by using GI strip of 32x6 mm sleeved using red colour PVC sleeving as earthing lead soldering/rivetted to earth plate at one end and connected to existing structure by means of nut, bolts etc complete with PCC pit (1:3:6) type PCC cover with handle, funnel with watering pipe wire mess GI protection pipe for earthing lead complete all as specified and as directed.
Supply and fixing Danger notice plate of 1.6 mm thick MS sheet,vitreous enamelled white with letters, figures and conventional skull and bones with MS clamp, bolts and nuts of approved size for HT 33 KV/ 11 KV mark complete
M & L for Prestressed concrete pole, 11.0 metres long. 152mm x 152mm at top and 152mm x 260mm at bottom, class 9, Incl taking down old pole and remove from site complete all as directed.
M & L for PCC 1:2:4 type B-2 (using 40 mm graded aggregate). For foundation, filling, mass concrete, coping etc incl finishing of external surfaces without applying extra cement incl dismantaling old PCC etc complete all as specified and directed.
M & L for PCC 1:4:8 type D-2 (using 40 mm graded aggregate). For foundation, filling, mass concrete, coping etc incl dismantling old PCC complete all as specified and directed by Engineer-in-Charge.
M & L for PCC 1:3:6 type C-2 (using 40 mm graded aggregate). For foundation, filling, mass concrete, coping etc incl dismantling old PCC complete all as specified and directed by Engineer-in-Charge.
Supply and lay cable XLPE insulated screened PVC bedded, galvanised steel strip or wire armored, electric power cables (heavy duty) 33000 volts grade earthed with stranded aluminium conductor of size 120 Sq mm, 3 core, including taking down of existing old unserviceable cable of any type and size complete all as specified and directed by Engineer-in-Charge.
Supply and lay cable XLPE insulated screened PVC bedded, galvanised steel strip or wire armored, electric power cables (heavy duty) 11000 volts grade earthed with stranded aluminium conductor of size 240 Sq mm, 3 core, including taking down of existing old unserviceable cable of any type and size complete all as specified and directed by Engineer-in-Charge.
Supply and lay cable XLPE insulated screened PVC bedded, galvanised steel strip or wire armored, electric power cables (heavy duty) 11000 volts grade earthed with stranded aluminium conductor of size 95 Sq mm, 3 core, including taking down of existing old unserviceable cable of any type and size complete all as specified and directed by Engineer-in-Charge.
M & L for excavation in trenches,for laying under ground cable,pipe lines, errection of poles and stays in any type of soil not exc 1.5 Mtr wide and not exc. 1.5 m in depth for foundation and getting out complete all as specified and as directed.
M & L for excavation in trenches,for laying under ground cable,pipe lines, errection of poles and stays in any type of soil not exc 3.0 Mtr wide and not exc. 3.0 m in depth for foundation and getting out complete all as specified and as directed.
M & L for returning filling in including spreading, levelling, watering and ramming in layers not exceeding 25 cm thick with earth obtained from excavation all as specified and as directed.
M & L for removal of surplus soil to a distance not exceeding 50 mtrs and depositing where directed at a level not exceeding 1.5 mtr above the starting point all as specified and as directed.
M & L for unwashed sand cushioning below and around cable in trenches with river sand all as specified and as directed by EIC.
Supplying and laying un-reinforced precast concrete cable cover HV, Type 1, flat, size 300mmx l80mm x 40mm complete all as directed by EIC.
S & F 80mm bores of tubes 'light grade' galvanised with all fittings and fixed complete with electric pole, laid in trenches for passing of XLPE cable all as specified and as directed by EIC.
S & F 100 mm bores of tubes 'light grade' galvanised with all fittings and fixed complete with electric pole, laid in trenches for passing of XLPE cable all as specified and as directed by EIC.
Supply and fixed cable jointing kit for 33KV grade cable for outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium condcutor cable of size but 120 sqmm all as specified and as directed by EIC.
Supply and fixed cable jointing kit for 11 KV grade cable for indoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium condcutor cable of size but 50 sqmm to 95 sqmm all as specified and as directed by EIC.
Supply and fixed cable jointing kit for 11 KV grade cable for outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium condcutor cable of size but 50 sqmm to 95 sqmm all as specified and as directed by EIC.
Supply and fixed cable jointing kit for 11 KV grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium condcutor cable of size but 50 sqmm to 95 sqmm all as specified and as directed by EIC.
Supply and fixed cable straight through jointing kit for 11 KV grade cable for in door termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium condcutor cable of size but 240 sqmm to 300 sqmm
Supply and fixed cable straight through jointing kit for 11 KV grade cable for out door termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium condcutor cable of size but 240 sqmm to 300 sqmm
S&F Copper strip of size 20x3 mm as in earth continiuty conductor fixed to wall on batten or recess or cases or buried in ground or any other situation for loop earthing as required at site al as specified and directed by engr in charge
Disconnecting electrical connections from HT 33/11 KV transformer of any descriptions by opening of earth & control connections of any type, sealing of oil leakage, replacement of unserviceable parts and filtration of oil, cleaning the transformer, including making all HT connections, control cable connection, earth connection etc including testing the transformer after necessary repairs, complete all as specified and as directed by Engineer-In-Charge. Note: Spares required for repair/ replacement of unserviceable parts shall be measured and paid separately under relevant items
Supply and fixing in replacement of primary coil of transformer of any capacity, made of super enameled copper winding wire/ strip of existing insulation, gauge and specifications, complete all as specified and as directed by Engineer-In-Charge. Note: Primary coil shall have same number of turns of winding wire and with matching to manufacturer design.
Supply and fixing in replacement of secondary coil of transformer of any capacity, made of super enameled copper winding wire/ strip of existing insulation, gauge and specifications, complete all as specified and as directed by Engineer-In-Charge. Note: Secondary coil shall have same number of turns of winding wire and with matching to manufacturer design.
Disconnecting electrical connections from HT and LT sides of old unserviceable/ damaged/ burnt step down transformers of any descriptions, capacity upto 400 KVA, any type and taking down from the platforms or mounted on exisiting position (four poles/ two pole structure) by hydraulic cranes of suitable capacity and transporting by truck/ lorry to the workshop, opening top cover, draining out the transformer oil in clean barrels, cleaning of sludge from oil tank and conservator tank, cleaning and polishing of tapping contact point, opening carefully copper wire/ strip wound LT coils and rewinding the same after providing new necessary insulating packing material by using the same old strip/ wire, refitting top cover with replacement of studs, nuts, bolts, washers and gasket after repairs/ replacement of unserviceable parts and cleaning the transformer and making the transformer absolutely leak proof, pouring in the insulating oil in the transformer, placing in original position on four pole/ two pole structure/ platform at site and making all HT/LT connections including testing the transformer after necessary repairs, complete all as specified and as directed by Engineer-In-Charge. Note: Spares required for repair/ replacement of unserviceable parts shall be measured and paid separately under relevant items of BOQ.
Replacement of old unserviceable/ damaged 33 KV HT bushing assembly with new HT bushing assembly (Set of three) with insulated brass stud including nuts, bolts and washers, suitable for transformer of any type, any capacity complete all as specified and as directed by Engineer-In-Charge.
Replacement of old unserviceable/ damaged 11 KV HT bushing assembly with new HT bushing assembly with insulated brass stud including nuts, bolts and washers, suitable for transformer of any type, of any capacity, complete all as specified and as directed by Engineer-In-Charge.
Replacement of old unserviceable/ damaged cork sheet gasket with new cork sheet gasket, suitable for transformer of any capacity, complete all as specified and as directed by Engineer-In-Charge.
Dehydration and filtration of transformer oil after draining out oil from transformer by the dehydration machine at site or nearby transformer workshop to achieve di-electric strength 40 KV at 4mm gap, complete all as specified and as directed by Engineer-In-Charge. Note: (i) Cost of transportation of dehydration machine and other required materials and tools, plants shall be deemed to be included in the quoted rates. (ii) Test certificate of di-electric strength from Govt auth Lab shall be produce before and after dehydradation and filtration process for each transformer.
Replacement of old unserviceable/ damaged air breather assembly with new air breather assembly with silica gel suitable for 33/11 KV transformer including nuts, bolts and washers complete all as specified and as directed by Engineer-In-Charge.
Replacement of old unserviceable/ damaged air breather assembly with new air breather assembly with silica gel capacity 500 gm suitable for 11/.440 KV transformer including nuts, bolts and washers complete all as specified and as directed by Engineer-In-Charge.
Supply only fresh transformer oil to top-up and filling in the existing transformer, di-electric strength not than 45 KV, meeting Bureau of Indian Standards: IS 335-1993 (Reaffirmed-2005) specification, examined in a 100mm thick layer at 270°C, clear, transparent and free from all type of suspended matter or sediment, complete all as specified and as directed by Engineer-In-Charge. Make: IOCL/ HPCL/ BPCL/ Reliance.
Preparation of old, external surface of 33/11 KV transformers of any capacity , by removing the scrap, rust, washing including cleaning and spray painting with two coats of synthetic enamel paint including numbering MES No in white colour synthetic enamel paint, at site or at workshop, complete all as specified and as directed by Engineer-In-Charge.
Preparation of old, external surface of 33/11/0.44 KV transformers any capacity, by removing the scrap, rust, washing including cleaning and spray painting with two coats of synthetic enamel paint including numbering MES No in white colour synthetic enamel paint, at site or at workshop, complete all as specified and as directed by Engineer-In-Charge.
M&L Lightening arresters expulsion type complete with all fittings, transmission class, discharge capacity 65 kilo amp, 33000 volts, complete all as specified and directed by Engineer-in-Charge.
M&L Lightening arresters expulsion type complete with all fittings, transmission class, discharge capacity 12 kilo amp, 11000 volts, complete all as specified and directed by Engineer-in-Charge.
M&L for Gang operated Isolating Switch 11 kV Triple pole vertical type, mechanically operated, mounted on insulator and steel frame, with operating mechanism worked from ground level, for current rating upto 400 amps, 15 insulators, incl drop out fuse assy, complete all as specified and directed by Engineer-in-Charge.
Supply and fixing Electrical accident / shock treatment chart mounted on wodden frame, complete all as specified and directed by Engineer-in-Charge.
M&L for guarding cradles, made to shape hexagonal/rectangular or any other shape fabricated with GI 4 mm dia wire including binding wire, complete all as specified and directed by Engineer-in-Charge.
S&F Disc type insulator porcelain, vitrous 145 mm high and 255 mm dia ball and socket type, (white, brown or green) complete single disc assembly for ACSR conductor having working pressure 11000 volts grade, complete all as specified and directed by Engineer-in-Charge.
S&F Pin type, porcelain, vitreous, white, brown or green insulator including one galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nut,150mm height, 150mm dia for 11000 volts grade, complete all as specified and directed by Engineer-in-Charge.
S&F post type, porcelain, vitreous, white, brown or green insulator including one galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nut, for 33000 volts grade, complete all as specified and directed by Engineer-in-Charge.
Cross arms, bracings, supports,clamps and back plates fabricated from structural steel sections including nuts, bolts, washers,welding, bending cold or hot,drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of paint including old U/S taking down, complete all as specified and directed by Engineer-in-Charge.
M&L for Hardcore Aggregate of guage n. exc 25mm deposited, spread and levelled in layers n exc. 15 cm thick, to a true surface, complete all as specified and directed by Engineer-in-Charge.
M&L for stay assembly with stay rod of dia 20mm complete with accessories as shown in electrical plate No. 1 (loop type insulator, stay clamps, excavation and concrete measured separately) as specified and directed by Engineer-in-Charge.
M&L for Loop type insulator, vitreous porcelain, white, brown or green Large size, with overall dimensions 90mmx140mm, clearance of hole 25.5mm all as specified and directed by Engineer-in-Charge.
Servicing and complete overhauling of VCB 11 KV Indoor type 630 Amps capacity including disassembly of operating mechanism parts, well cleaning with petrol & CRC-226, replacing of moving parts, re-assembly, fine setting of mechanism, replacement of unserviceable parts and re-assembly of parts including well cleaning the complete panel board main bus bar, de-carbonizing all joints, bus bar, CTs’ PTs spouts, metal parts and making VCB perfect operation in manual and electric mode including all routine and preventive maintenance, complete all as specified and directed by Engineer-in-Charge.
Routine preventive and annual maintenance of RTCC Panel, dismantling complete and cleaning, repair / replacement of burnt out electrical accessories, checking of connections , repair and replacement of complete internal wiring, current and earth fault relay, voltmeter, ammeter, tripping coil with system, burnt out elecrical parts etc. as existing specification, setting of relays with provided values, complete all as specified and directed by Engr-in-charge. All minor/ Burnt spares/works, bolts, nuts, washers, connectors, pins, panel hinges, locks, allignment, lubricants etc shall also be included in quoted rates.
Supply and fixing by stringing stretching and strengthening on insulators ACSR conductor of desired size including aluminium binding wire of suitable cross sectional area including joints sleeve for jointing conductors of equal or unequal size and for jumpers connections including treatment of connector and ACSR conductor joints/jumpers with conducting jelly, and taking down of UNSV conductors, complete all as specified and directed.
M/S SHARMA ENTERPRISES
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .