Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹5.9 CrAccepted-AOC | ₹5.9 Cr | L1 | Accepted-AOC Being Lowest |
| 2 | L2₹5.9 Cr+₹22,436.36 (0.04%)Rejected-Finance | ₹5.9 Cr+₹22,436.36 (0.04%) | L2 | Rejected-Finance Not Lowest |
| 3 | L3₹6.0 Cr+₹13.5 L (2.30%)Rejected-Finance UTARLAI KAWAS BARMER RAJASTHAN 344 001 | BARMER | RAJASTHAN | 344001 | ₹6.0 Cr+₹13.5 L (2.30%) | L3 | Rejected-Finance Not Lowest |
| 4 | L4₹6.4 Cr+₹51.8 L (8.83%)Rejected-Finance JODHPUR ROAD UTARLAI BARMER RAJ 344035 | BARMER | RAJASTHAN | 344035 | ₹6.4 Cr+₹51.8 L (8.83%) | L4 | Rejected-Finance Not Lowest |
| 5 | L5₹6.6 Cr+₹69.6 L (11.9%)Rejected-Finance STREET NO 11 SECTOR NO 04 TILAK NAGAR SAGAR ROAD BIKANER RAJASTHAN 334001 | BIKANER | RAJASTHAN | 334001 | ₹6.6 Cr+₹69.6 L (11.9%) | L5 | Rejected-Finance Not Lowest |
Tender Value
Refer Docs
EMD Value
₹6.5 L
Closing Date
3 Jun 2021, 6:00 pmClosed
CE (AF) Gandhinagar
HQ CE (AF) Gandhinagar Lekawada Patia Chiloda PO CRPF Campus Gandhinagar 382042
Work Services for Induction of New System at AF Stn Utarlai
2021_MES_428643_1
82353/E8
Open Tender
Civil Works
Lump-sum
540 days
GE (AF) Utarlai
As per NIT
8 documents required · 8 mandatory
₹3,000
GE (AF) Utarlai
₹6.5 L
Yes
22 Jul 2021
6 Mar 2021
4 Jun 2021
6 Mar 2021
3 Jun 2021
5 May 2021
13 Mar 2021 - 25 Mar 2021
Amount
NOTE: Schedule ‘A’ Part I to XIII are under Ser No. 2.00 to 14.00. are Prepriced by MES. Bidders shall insert their lumpsum amount in the Green coloured field under Col-6 only.
Lump sum price worked out for Building / Structures as listed in Sch `A’ Part I.
Lump sum price worked out for Excavation & Earthwork as listed in Sch `A’ Part II
Lump sum price worked out for Internal Water Supply as listed in Sch `A’ Part III
Lump sum price worked out for Internal Electrification as listed in Sch `A’ Part IV
Lump sum price worked out for Road/Path/Hard Standing as listed in Sch `A’ Part V
Lump sum price worked out for Sewage Disposal as listed in Sch `A’ Part VI
Lump sum price worked out for External Water Supply as listed in Sch `A’ Part VII
Lump sum price worked out for External Electric Supply as listed in Sch `A’ Part VIII
Lump sum price worked out for Lightening Protection as listed in Sch `A’ Part IX
Lump sum price worked out for Fire Alarm System as listed in Sch `A’ Part X
Lump sum price worked out for Cooling Appliancies as listed in Sch `A’ Part XI
Lump sum price worked out for Security Fencing and Gate as listed in Sch `A’ Part XII
Lump sum price worked out for Chiler Type AC Plant as listed in Sch `A’ Part XIII
SCHEDULE 'A' PART - XIV Fittings & fixtures is not prepriced by MES and prepriced rates indicates 0.0 under column 5 signified this fact only. Bidder shall insert their rates in Green filed under Col-6.
INTERNAL ELECTRIFICATION
Supply and fixing ceiling fan 1400mm sweep complete with blade, canopy and down rod, energy efficient 5 star rated high speed with minimum 2 yrs warranty including copper winding and connecting up to and including provision of flexible three core copper conductor cable 23/0.0076 from ceiling rose to connector block etc complete all as specified and directed.
Supply and fixing metallic Exhaust fan 300mm sweep 240 V AC single phase complete with lovers and shutters of any sweep including provision of flexible three core copper conductor cable of 23/0.0076 upto ceiling rose and grouting 04 Nos full threaded bolts and nuts etc complete all as specified and directed.
Supply and fixing LED batten single tube 1 x 20 W (4 feet long) 230V AC, IP20, 6000K, Rated CCTenergy efficient with automic ballast bipin holders starter blocks, diffusers etc complete with all accessories internally pre wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size complete all as specified and directed.
Supply and fixing LED batten single tube 1 x 10 W (2 feet long) 230V, AC, IP20, 6000K Rated CCTenergy efficient with automic ballast bipin holders starter blocks, diffusers etc complete with all accessories internally pre wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size complete all as specified and directed.
Supply and fixing LED Building Security light luminaire LED 15 W, IP66, 5700K with lumen efficiency not less than 110 lumen/watt pf 0.8 IP-45 with aesthetically designed sheet aluminium housing and UV stabilised acrylic cover complete with lamp and internal connection including bracket made of 40 mm dia GI pipe light grade fixed with MS Clamp of suitable size grouted on wall with suitable nos of screws complete all as specified and directed.
Material & labour for MCB single pole 5 to 30 Amp 240 volt C curve 10 KA, IP 20 complete all as specified and directed.
Supply and fixing Power unit for AC including MCB SP of 25 Amp and one START and one STOP push button complete all as specified and directed.
Material & labour for flame proof point wiring complete using colour code with two run of 1.5 Sqmm(nominal area single core multi-stranded copper conductor FRLSH PVC insulated and unsheathed multistrandard copper conductor cable 650/1100 V grade conforming to IS-694 drawn through and including ERW steel conduit 20 mm dia (external flame froof) heavy grade (IS Marked) including necessary all accessories/fixtures , concealed in wall , ceiling including sunken type pressed steel terminal boxes with flame retardant sheet of approved shade 3 mm thick including providing continuous earth wire with one single run of 1.5 sq mm single core mult-stranded copper conductor FRLSH, PVC insulated and unsheathed cable 1100 volts grade conforming to IS 694 for one light point controlled by one way flame proof switch etc , complete all as specified and directed Note : The cost of cutting chases in wall /floor/ceiling wherever required and making good the surface as exists shall be deemed to be included in respective items of schedule
Material & labour for flame proof and weather proof(protection class IP 65) enclosure suitable for LED tube light fitting including lamp (tube), 1x36/40 watt 230 v 5700 CCRT lumen efficiency not less than 100 lumen/watt pf 0.8 with aluminium cast alloy LM-6 inside and outside light grey expoxy costing, prewired complet all accessories fixed on wall or on ceiling including mounting stand and connecting up complete with 23/0.0076 flexible three core copper cable in flexible steel conduict with flame proof cable glands complete all as specified and directed.
Supply & fix flame proof Exhaust fan ,single phase 230/240 volts, 50 Hz of size 300mm sweep, heavy duty with louvers etc complete all as specified and as directed.
Supply & fix LED 150 W rectangular high bay light energy saving environmental friendly. Iong life minimum. IP54 protection prewired and including connector for connecting lamp with all flxing accessories etc complete all as specified and as directed .
Supply & fix PVC copper conductor 3 core 2.5 Sqmm multistranded 1100 volts grade drawn through rigid PVC conduit 25 mm dia concealed in wall/ceilings etc complete all as specified and as directed. .
Supply & fix PVC copper conductor 3 core 1.5 Sqmm multistranded 1100 volts grade drawn through rigid MS ERW conduit medium grade 20 mm dia fixed on prestressed concrete pole by using suitable steel clamps etc complete all as specified and as directed. .
Supply and install hi wall split unit air conditiner indoor/outdoor complete with cordless remote control unit and with inbuilt air ionizer and plasma filter for better indoor air quality capacity 2 TR including minimum 3 star rating etc complete all as specified and as directed. .
Supply and fixing of voltage stabilizer for automatic operation single phase naturally air cooled indoor type & designed for input variation between 170 V to 260 V with output voltage stablized at 230 V with accurancy of + 2.5% and of capacity 5.0 KVA etc complete all as specified and as directed. .
REFRIGERATION AND AIR CONDITIONING
Supply and fixing of voltage stabilizer copper wounded for automatic operation single phase naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stablized at 230 V with accuracy of + 2.5% and of capacity 1.0 KVA complete on wall and making necessary electric connection with AC unit complete all as specified and directed.
Supply and installed refrigerators electric driven single phase of capacity 195 Ltrs BEE 5 rated including suitable mounting unit complete all as specified and directed.
FIRE ALARM SYSTEM
Supply and fixing of stove enamelled black MS conduit 25mm dia ISI marked on ceiling or recessed as required making good the same disturbed surfaces complete all as specified and directed
Supply and fixing of stove enamelled black MS conduit 20mm dia ISI marked on ceiling or recessed as required & repairing & making good the same disturbed surfaces complete all as specified and directed
Supply and draw in steel conduit multi strand copper conductor wire 1.0 Sqmm single core, FRLS 1100 Volt grade complete all as directed. Number of to be drawn through each conduit shall be decided by Engineer-in-Charge complete all as specified and directed Note For item No 1 to 9 Indian Standard (IS)-2189 must be followed.
Supply and fixing Automatic type fire extinguisher(Modular) Clean agent 5Ltrs. Capacity, suitable for ABC class of fire and electric with initial filling in brand new cylinder with epoxy polyster powder coated finish on external surface, ceiling mounted fitted effective discharge 95%,Area coverage:3 mtrs ,Disharge minimum 8 sec ,state of art pressure gauge,Nominal gas storage pressure confirming to IS: 15683, etc. complete all as specified and directed
S&F CO2 tube suppression system fire class A B C material MS ISI certified burst pressure 15 bar complete with fitting arrangement ready to use in panel tube base fire suppression accessories complete.
Supply and fixing light weight sqeeze grip Carbon-di- oxide type fire extinguisher of 4.5 kgs. Capacity,CO2 gas filled in brand new seamless cylinder with powder coated finish, made out of Manganese steel, with wheel type valve, discharge Nozzle, bend & horn, wall mounting bracket /floor trolley mounting accessories with suitable signage'scomplete, confirming to IS: 15683-2018 complete all as specified and directed
Supply, installation, testing and commissioning of 10 zones repeater panet for intro phasing the main panel having provision of audio, video indicator in main panel zone for remote indicator complete all as specified and directed
Suppy and fix board of size 4'x3' with instruction printed "lF A FIRE OCCURS" complete all as specified and directed
Supply and fix fire sign board with standard marking for fire fighting services such as '(I) stairs exit: (ii) In case of fire (iii) fire exit (iv) fire alarm call (v) fire hose real (vi) emergency key board" or any type of sign board as required at site. The size of fire indicators shall be of 300mmx150mmx5mm thick complete all as specified and directed
Supply and install of fire display board thickness 12mm with wooden side border duly marked with name of bldg with details and layout diagram, & location, radiant sticker with approved colour including fixing arrangement on wall .size of board : 1.0M x 1.2 M all as specified and directed by EIC. Note: Layout diagram and description details to be collected from engineer in charge complete all as specified and directed
SEWAGE DISPOSAL
Material and labour for 150mm dia SGSW pipes grade 'A', excavation in soft soil at average depth of 1.5 m inclusive of manhole and RCC/CI manhole cover pipes laid on PCC 1:3:6 type C2 stone aggregate 40mm graded bed including packing under hauching against sides complete all as specified and directed.
EXTERNAL WATER SUPPLY
Material and labour for construction of for Valve Pit /Chamber in PCC solid block masonry (1:5:8) built in CM 1:6 ,over 150 mm thick PCC foundation 1:3:6 type C2, 10mm thick internal CM 1:6 & 12mm thick external plaster in CM 1:4 provided with 3 mm thick MS sheet cover 3.15 mm thickness along with angle iron frame of size 40x40x6 mm and MS angle iron chamber frame fixed in coping in PCC 1:2:4 type B-1 with locking arrangement and handle, painting of MS work with one coat of red oxide primer and two coat of synthetic enamel black paint complete including excavation & earth work in any type of strata complete all as shown on drawing No.CEAA/TD/57sheet No 1.1,dated 28.05.92,amended upto 31.12.92, but of internal size 900mm(L) x 900mm(B) x 900mm (D) etc complete all as specified and directed.Note : Excavation Retuning filling is including in the item
Supply, installing testing and commisioning of centrifugal pump sets electrical driven working voltage range 370-450 volts 3 phase 18 meter head , 5HP capacity, discharge capacity 13.2 LPS and suction and deliver end 80/65mmbore complete inclusive of suitable relay , starter mounted on enclosures and PCC foundation complete all as specified and asm directed.
Supply, installing testing and commisioning of centrifugal pump sets electrical driven working voltage range 370-450 volts 3 phase 16 meter head , 3HP capacity, discharge capacity 9.3 LPS and suction and deliver end 65/50mmbore complete inclusive of suitable relay , starter mounted on enclosures and PCC foundation complete all as specified and asm directed.
Material & labour for cutting the existing 150mm DI pipe bore in position for providing the ferrule with clamps,nuts,bolts and necessary threading all as directed. Note: excavation and earth work will be measured separately complete all as specified and asm directed.
EXTERNAL ELECTRIFICATION
Material & labour for sand cushioning all round the cable for protection by natural tibba sand complete all as specified and asm directed.
Supplying and laying stone patti 40-50 mm thick, 25-30 cm wide abutting each other for cable protection complete all as specified and asm directed.
Supply, install, test and commission weather proof feeder pillar box(1.0x0.45x0.90) fabrication with 3.15 mm thick CRCA sheet mounted on 50x50x6mm MS angle consists of the following items:- complete all as specified and asm directed. (a) Aluminium bus bar 3 phase & neutral of capacity 400 Amps. (b) MCCB 4 P 250 Amps 35 KA -01 No (incoming) OUT GOING (i) MCCB 3 pole 100 Amps-02 Nos (ii) MCCB 3 pole 63 Amps-03 Nos (iii) MCB SPN 6 to 32 Amps-02 No (iv) Multifuction Meter-01 No (v) CT 500/5 Amps (vi) RYB indicating lamp Set of 3-01 No (vii) Space for spare MCCB-02 Nos
Supply & fix double compression copper stain less steel gland for fixing armoured cable in panel of 4 core 25 to 50 sqmm size complete all as specified and asm directed.
Supply & fix double compression copper stain less steel gland for fixing armoured cable in panel of 4 core 16 sqmm size complete all as specified and asm directed.
Supply & fix double compression copper stain less steel gland for fixing armoured cable in panel of 2 core 10 sqmm size complete all as specified and asm directed.
Supply & fix LED street light luminaries 1 x 70 watt, IP65 protection with minimum system efficacy >85lm /watt made of pressure die cast housing toughened glass in the front & lens complete with all accessories and connecting from ceiling rose to terminal block of light fitting with cable 3 core 0.50 sq mm all as and fixed on and including Galvanized (hot dip) bracket fixed on wall complete all as specified and asm directed.
Supply & fix FRP pole box of size not less than 300x200x125 mm fixed to poles with 6 Amps MCB SP 230 Volts AND 3 WAY connector including clamps bolts and GI washers complete all as specified and asm directed.
Supply, install, testing and commissioning weather proof feeder pillar box outdoor type (1.0x0.45x0.90) fabricated with 3.15mm thick CRCA sheet mounted on 50x50x6mm MS angle consists of the following items Aluminium bus bar 3 phase& neutral of capacity 100 Amps Incoming. (i) MCCB 4 pole 63 Amps, 35 KA - 01 Nos. Outqoinq: (i) MCCB 3 pole 32 Amps - 01 No.(ii) MCB TPN 6 to 32 Amps - 01 Nos. (iii) MCB SPN 6 to 32 Amps - 04 Nos. (iv) Multifunction meter - 01 Nos. (v) CT 500/5A (vi) RYB indicating Iamp set of 3 - 01Nos. (vii) Space for spare MCCB - 02 Nos complete all as specified and asm directed.
Supply, install, testing and commissioning weather proof feeder pillar box outdoor type (1.0x0.45x0.90) fabricated with 3.15mm thick CRCA sheet mounted on 50x50x6mm lvlS angle consists of the following items:- Aluminium bus bar 3 phase& neutral of capacity 160 Amps lncominq: (i) MCCB 4 pole 100 Amps, 35 KA - 0'1 Nos. Outooinq: (i) MCCB 3 pole 63 Amps - 01 No.(ii) MCB TPN 6 to 32 Amps - 0'1 Nos. (iii) MCB SPN 6 to 32 Amps - 04 Nos. (iv) Multifunction meter - 01 Nos. (v) CT 500/5A (vi) RYB indicating lamp set of 3 - 01Nos. (vii) SDace for sDare MCCB - 02 Nos complete all as specified and asm directed.
SECURITY WALL
Supply & fixg galvanised punched tape concertina coil of 1050mm dia (dia of coil when unstretched) and 2.6mm dia of core wire and shall not be less than 78 Nos of spiral in each 10RM length and fixed on angle iron post/struts with 3.15mm dia GI wire complete all as specified and as directed.
CHILER TYPE AC PLANT
Supply, installation, testing and commissioning of monoblock, self-priming, single-stage, centrifugal volute type pump, suitable for 4.0 LPS water flow rate and 12 MWC head, having cast iron casing, enclosed type dynamically balanced phosphor-bronze/SS impeller, high tensile steel shaft, carbon steel stuffing box (sealed by mechanical seal), deep groove ball bearings, TEFC squirrel cage induction motor having IE- 3 efficiency and conforming to IS: 12615- 2018, base plate, mounting channel frame, elastomeric insulation, accessories and fittings, viz. mechanical seal, pressure gauges, thermometers, drains, coupling, coupling guard, vibration isolation arrangement by means of spring / rubber type mounting suitable for operation on 3- Phase, 415 V ± 10%, 50 Hz AC supply complete all as specified and directed by the engineer-in-charge. Make: Kirloskar, Mather & Platt, Crompton Greaves NOTES:[i] Necessary civil work viz. foundation for placement of pump, mounting of star/delta starter panel and pump accessories shall be covered in the scope of work complete all as specified and as directed..
Supply, installation, testing and commissioning of monoblock, self-priming, single-stage, centrifugal volute type pump, suitable for 8.8 LPS water flow rate and 10 MWC head, having cast iron casing, enclosed type dynamically balanced phosphor-bronze/SS impeller, high tensile steel shaft, carbon steel stuffing box (sealed by mechanical seal), deep groove ball bearings, TEFC squirrel cage induction motor having IE- 3 efficiency and conforming to IS: 12615- 2018, base plate, mounting channel frame, accessories and fittings, viz. mechanical seal, pressure gauges, thermometers, drains, coupling, coupling guard, vibration isolation arrangement by means of spring / rubber type mounting suitable for operation on 3- Phase, 415 V ± 10%, 50 Hz AC supply complete all as specified and directed by the engineer-in-charge. Make: Kirloskar, Mather & Platt, Crompton Greaves NOTES:[i] Necessary civil work viz. foundation for placement of pump, mounting of star/delta starter panel and pump accessories shall be covered in the scope of work.
Supply & fix multilayered HDPE storage tank of 7500 litre capacity made up of 100% virgin material, having 100% UV stabilized white outer layer, threaded lid, extra insert lid for protection against algae formation complete with inter-connection piping and non-return valve etc. complete all as specified and directed.
Supply & fix SS- 304 closed expansion tank of 05 litre capacity with pressure rating to suit the system pressure and sized adequately to compensate for water expansion due to operating temperature variations, conforming to IS: 2825- 1969 for 'non-fired pressure vessels' complete with inter-connection piping, non-return valve, safety relief valve and pressure gauge, insulated with 50 mm thick elastomeric insulation and cladded with 26 gauge aluminium complete with accessories complete all as specified and as directed.
Auomatic star/delta starter for chilled water circulation pump [2.0 HP]
Auomatic star/delta starter for condenser water pump [3.0 HP]
Auomatic star/delta starter for cooling tower fan motor [2.0 HP]
Supply, installation, commissioning and testing of factory made, CPRI type tested, outdoor, cubical compartmental type "HVAC Panel" of suitable size, conforming to IEC 61439-1 &2, IEC 61641, having both sides openable with hinged double doors & locking arrangement and IP 42 protection made out of 3.15 mm thick mild steel CRCA sheet, supported and fixed on structural frame of angle iron of suitable size, including earthing stud, labeling, painting to all internal & external exposed steel surfaces with powder coating paint (7 tank process), duly fixed in ground with PCC foundation (1:2:4) type B1, with danger notice plate of 1.6 mm thick mild steel sheet, vitreous enameled (white) with letters figures and conventional skull and bones in signal red colour, suitable for 3- Phase 4 Wire system, 500 V grade with necessary wiring, PVC sheathed stranded copper conductor of appropriate length & size, including fixing lugs, bolts, screws etc. complete with accessories complete all as specified and as directed. The HVAC Panel shall comprise of the following:
Busbar Chamber: [i] 01 Set (3L + N) of copper busbar of rated capacity 160 A, covered with PVC insulated sleeves including insulator, nuts, bolts, etc. with complete connection Incoming: [i] 100 A, 415 V, Ics = Icu = 25 kA, conforming to IEC 60947- 2, 50 Hz, FP MCCB with adjustable overload settings, adjustable short-circuit settings, adjustable neutral protection, adjustable earth- fault settings, instantaneous protection and microprocessor based trip unit- 01 Nos. [ii] Cl 1.0 multi-function meter capable of measuring V, A, F, PF, W/VA, Wh/VAh, Runhrs. Onhrs & interrupts- 01 Nos. [iii] LED phase indicators (Red, Yellow, Blue)- 01 Set Outgoing: [i] 40 A, 415 V, Ics = Icu = 25 kA, conforming to IEC 60947- 2, 50 Hz, FP MCCB with adjustable thermal settings (0.70- 1 X In) & fixed magnetic settings with compression lug connectors and thermal magnetic trip unit (TMD)- 03 Nos. [for chillers] [ii] 32 A, 415 V, Ics = Icu = 25 kA, conforming to IEC 60947- 2, 50 Hz, FP MCCB with adjustable thermal settings (0.70- 1 X In) & fixed magnetic settings with compression lug connectors and thermal magnetic trip unit (TMD)- 01 Nos. [for AHU] [iii] 16 A, 415 V, Ics = Icu = 25 kA, conforming to IEC 60947- 2, 50 Hz, FP MCCB with adjustable thermal settings (0.70- 1 X In) & fixed magnetic settings with compression lug connectors and thermal magnetic trip unit (TMD)- 05 Nos. [for CHWP, CDWP and cooling tower] [iv] 32 A, 230 V, 50 Hz, SPN MCB (C- curve)- 01 Nos. [for AC Plant
Room] [v] LED phase indicators (Red, Yellow, Blue)- 09 Set [vi] Cl 1.0 multi-function meter capable of measuring V, A, F, PF, W/VA, Wh/VAh, Runhrs. Onhrs & interupts- 09 Nos. NOTES: [i] The panel shall be completely Ethernet communication ready to communicate with Energy Management System & shall be Web based application in-built. [ii] The Panel shall be with wireless energy sensor on incomer and outgoing feeders for monitoring (V, I, P, PF, Energy), voltage loss alarm, Unbalance in phases. Same shall be communicated through Ethernet communication gateway to centralized Energy Monitoring System
Supply, installation, testing and commissioning of 65 mm NB cast steel bolted cover Y-type strainer with CCS body conforming to ASTM A- 216 Gr. WCB, AISI 304 screen with 1.2 mm diameter perforation, 20 kg/cm2 body test pressure & 20 kg/cm2 maximum working pressure and standard flange end conforming to BS 10 Table F / Class-150 with necessary accessories complete all as specified and directed.
Suply, installation, testing and commissioning of wafer type PN 1.6 rated short pattern CI butterfly valve having Gr. FG-200 CI body conforming to IS 210: 2009, seat having EPDM rubber lining, CF 8 stainless steel disc, AISI- 410 stainless steel stem, 2.4 MPa body test pressure & 1.6 MPa seat test pressure and standard flange end conforming to BS 10 Table D/E & ANSI B 16.1 CI- 125 with necessary accessories complete all as specified and as directed.
Supply, installation, testing and commissioning of precise balancing, double regulation type cast iron balancing valve having FG 200 cast iron body conforming to IS 210: 2009, copper alloy trim, stainless steel 2 Cr. 13 stem, 2.4 MPa body test pressure & 1.6 MPa maximum working pressure and standard flange ends with necessary accessories complete all as specified and as directed.
Supply & fix of CL 150 # rated 25 mm NB ball valve, designed & manufactured as per IS: 9890 (1981) and tested as per BS 6755 Part- I, having floating type three piece design, CS body, SS- 304 ball, PTFE seal/packing/gasket, CS fastners and lever and screwed/socket weld end connection, etc. with accessories complete all as specified and directed.
Supply, laying / fixing, testing and commissioning of chilled water circulation piping including necessary fittings viz. bends, tees, reducers, flanges, air purge valves, drain valves, structural support, necessary clamps, vibration isolators, etc. including painting and supporting / fixing the pipe in excavated trenches or on floor / wall / ceiling with clamps, hangers, angles, channels (using anchor fastners) with necessary accessories duly insulated with FM approved highly- flexible, closed-cell thermal insulation of elastomeric foam based on synthetic rubber (NBR) of apppropriate thickness laminated with 12 micron aluminium foil facing with reinforced glass scrim tested for service temperature range 0- 105 ˚C as per EN 14706, EN 14707 & EN 14304, thermal conductivity λ ≤ 0.037 W/mK at mean temperature θm = 20 ˚C as per EN 12667 & EN ISO 8497, water vapour diffusion resistance factor μ ≥ 12000 as per EN 12086 & EN 13469, water absorption by volume 0.2% as per ASTM C 1763 & ASTM C 209, Class 0 fire performance as per BS 476 Part 6: 1989, Class 1 surface spread of flame as per BS 476 7: 1997, flammability HB, V-0 as per UL- 94, having good resistance to mechanical impact, excellent resistance to ozone, oil and chemicals, zero ozone depletion potential along with adhesives and other necessary accessories complete all as specified and directed.
[i] The pipe size 150 mm NB & below shall be MS 'C' class as per IS 1239 (Part- 1): 2004 & IS 1239 (Part- 2): 2011. [ii] The pipe size above 150 mm NB shall be welded black steel pipe heavy class as per IS 3589: 2001. [iii] Minimum thickness of MS sheet for pipe size above 150 mm NB and up to 350 mm NB shall be 6.35 mm and it shall be 7 mm for pipe size 400 mm NB and above.
Supply, installation, testing and commissioning of cast steel bolted cover Y-type strainer with CCS body conforming to ASTM A- 216 Gr. WCB, AISI 304 screen with 1.2 mm diameter perforation, 20 kg/cm2 body test pressure & 20 kg/cm2 maximum working pressure and standard flange end conforming to BS 10 Table F / Class-150 duly insulated with FM approved highly- flexible, closed-cell thermal insulation of elastomeric foam based on synthetic rubber (NBR) of apppropriate thickness laminated with 12 micron aluminium foil facing with reinforced glass scrim tested for service temperature range 0- 105 ˚C as per EN 14706, EN 14707 & EN 14304, thermal conductivity λ ≤ 0.037 W/mK at mean temperature θm = 20 ˚C as per EN 12667 & EN ISO 8497, water vapour diffusion resistance factor μ ≥ 12000 as per EN 12086 & EN 13469, water absorption by volume 0.2% as per ASTM C 1763 & ASTM C 209, Class 0 fire performance as per BS 476 Part 6: 1989, Class 1 surface spread of flame as per BS 476 7: 1997, flammability HB, V-0 as per UL- 94, having good resistance to mechanical impact, excellent resistance to ozone, oil and chemicals, zero ozone depletion potential along with adhesives and other necessary accessories complete all as specified and directed.
Suply, installation, testing and commissioning of wafer type PN 1.6 rated short pattern CI butterfly valve having Gr. FG-200 CI body conforming to IS 210: 2009, seat having EPDM rubber lining, CF 8 stainless steel disc, AISI- 410 stainless steel stem, 2.4 MPa body test pressure & 1.6 MPa seat test pressure and standard flange end conforming to BS 10 Table D/E & ANSI B 16.1 CI- 125 duly insulated with FM approved highly- flexible, closed-cell thermal insulation of elastomeric foam based on synthetic rubber (NBR) of apppropriate thickness laminated with 12 micron aluminium foil facing with reinforced glass scrim tested for service temperature range 0- 105 ˚C as per EN 14706, EN 14707 & EN 14304, thermal conductivity λ ≤ 0.037 W/mK at mean temperature θm = 20 ˚C as per EN 12667 & EN ISO 8497, water vapour diffusion resistance factor μ ≥ 12000 as per EN 12086 & EN 13469, water absorption by volume 0.2% as per ASTM C 1763 & ASTM C 209, Class 0 fire performance as per BS 476 Part 6: 1989, Class 1 surface spread of flame as per BS 476 7: 1997, flammability HB, V-0 as per UL- 94, having good resistance to mechanical impact, excellent resistance to ozone, oil and chemicals, zero ozone depletion potential along with adhesives and other necessary accessories complete all as specified and directed by engineer-in-charge.
Suply, installation, testing and commissioning of 40 mm NB wafer type PN 1.6 rated swing check type multidoor reflux valve (NRV), designed & tested as per IS 5312 (Part- 2): 1986, suitable to handle clear water having turbidity up to 5000 PPM, having CI body, door and diaphram, leaded tin bronze seat rings and flange drilling standard end connection, etc. duly insulated with FM approved highly- flexible, closed-cell thermal insulation of elastomeric foam based on synthetic rubber (NBR) of apppropriate thickness laminated with 12 micron aluminium foil facing with reinforced glass scrim tested for service temperature range 0- 105 ˚C as per EN 14706, EN 14707 & EN 14304, thermal conductivity λ ≤ 0.037 W/mK at mean temperature θm = 20 ˚C as per EN 12667 & EN ISO 8497, water vapour diffusion resistance factor μ ≥ 12000 as per EN 12086 & EN 13469, water absorption by volume 0.2% as per ASTM C 1763 & ASTM C 209, Class 0 fire performance as per BS 476 Part 6: 1989, Class 1 surface spread of flame as per BS 476 7: 1997, flammability HB, V-0 as per UL- 94, having good resistance to mechanical impact, excellent resistance to ozone, oil and chemicals, zero ozone depletion potential along with adhesives and other necessary accessories complete all as specified and directed.
Supply, installation, testing and commissioning of precise balancing, double regulation type cast iron balancing valve having FG 200 cast iron body conforming to IS 210: 2009, copper alloy trim, stainless steel 2 Cr. 13 stem, 2.4 MPa body test pressure & 1.6 MPa maximum working pressure and standard flange ends duly insulated with FM approved highly- flexible, closed-cell thermal insulation of elastomeric foam based on synthetic rubber (NBR) of apppropriate thickness laminated with 12 micron aluminium foil facing with reinforced glass scrim tested for service temperature range 0- 105 ˚C as per EN 14706, EN 14707 & EN 14304, thermal conductivity λ ≤ 0.037 W/mK at mean temperature θm = 20 ˚C as per EN 12667 & EN ISO 8497, water vapour diffusion resistance factor μ ≥ 12000 as per EN 12086 & EN 13469, water absorption by volume 0.2% as per ASTM C 1763 & ASTM C 209, Class 0 fire performance as per BS 476 Part 6: 1989, Class 1 surface spread of flame as per BS 476 7: 1997, flammability HB, V-0 as per UL- 94, having good resistance to mechanical impact, excellent resistance to ozone, oil and chemicals, zero ozone depletion potential along with adhesives and other necessary accessories complete all as specified and directed by engineer-in-charge.
Supply, installation, testing and commissioning of 50 mm NB electronic, self-balancing, pressure independent type dynamic balancing valve rated for minimum 25 bar working pressure with integrated 2-way modualating control valves in a single body and actuator capable of accepting upto 10 V DC and up to 20 mA electric signal and provide similar transduced feedback output to control system duly insulated with FM approved highly- flexible, closed-cell thermal insulation of elastomeric foam based on synthetic rubber (NBR) of apppropriate thickness laminated with 12 micron aluminium foil facing with reinforced glass scrim tested for service temperature range 0- 105 ˚C as per EN 14706, EN 14707 & EN 14304, thermal conductivity λ ≤ 0.037 W/mK at mean temperature θm = 20 ˚C as per EN 12667 & EN ISO 8497, water vapour diffusion resistance factor μ ≥ 12000 as per EN 12086 & EN 13469, water absorption by volume 0.2% as per ASTM C 1763 & ASTM C 209, Class 0 fire performance as per BS 476 Part 6: 1989, Class 1 surface spread of flame as per BS 476 7: 1997, flammability HB, V-0 as per UL- 94, having good resistance to mechanical impact, excellent resistance to ozone, oil and chemicals, zero ozone depletion potential along with adhesives and other necessary accessories complete all as specified and directed by engineer-in-charge. NOTES: [i] Maximum close off pressure shall not be less than 6 bar for upto 50 mm valves. [ii] Maximum close off pressure shall not be less than 7 bar for 65 mm & above.
Supply & fix of CL 150 # rated 20 mm NB ball valve, designed & manufactured as per IS: 9890 (1981) and tested as per BS 6755 Part- I, having floating type three piece design, CS body, SS- 304 ball, PTFE seal/packing/gasket, CS fastners and lever and screwed/socket weld end connection, etc. with accessories duly insulated with FM approved highly- flexible, closed-cell thermal insulation of elastomeric foam based on synthetic rubber (NBR) of apppropriate thickness laminated with 12 micron aluminium foil facing with reinforced glass scrim tested for service temperature range 0- 105 ˚C as per EN 14706, EN 14707 & EN 14304, thermal conductivity λ ≤ 0.037 W/mK at mean temperature θm = 20 ˚C as per EN 12667 & EN ISO 8497, water vapour diffusion resistance factor μ ≥ 12000 as per EN 12086 & EN 13469, water absorption by volume 0.2% as per ASTM C 1763 & ASTM C 209, Class 0 fire performance as per BS 476 Part 6: 1989, Class 1 surface spread of flame as per BS 476 7: 1997, flammability HB, V-0 as per UL- 94, having good resistance to mechanical impact, excellent resistance to ozone, oil and chemicals, zero ozone depletion potential along with adhesives and other necessary accessories complete all as specified and directed
Supply, laying / fixing, testing and commissioning of 15 mm NB drain piping including necessary fittings viz. bends, tees, reducers, flanges, air purge valves, drain valves, structural support, necessary clamps, vibration isolators, etc. including painting and supporting / fixing the pipe on floor / wall / ceiling with clamps, hangers, angles, channels (using anchor fastners) with necessary accessories complete all as specified and as directed.
Supply & fix of CL 150 # rated 15 mm NB ball valve, designed & manufactured as per IS: 9890 (1981) and tested as per BS 6755 Part- I, having floating type three piece design, CS body, SS- 304 ball, PTFE seal/packing/gasket, CS fastners and lever and screwed/socket weld end connection, etc. with accessories complete all as specified and directed.
Supply, installation, testing and commissioning of automatic air-vent valve with 20 mm end connections, brass OT 58 body and cover, polyacetal lever, high density expanded polyethylene float, EPDM rubber plug, stainless steel spring, polyamide cap etc. suitable for maximum operating pressure of 16 bar and maximum operating temperature 115 °C respectively, installed on all high points in the water piping system to automatically remove the trapped air complete all as specified and directed.
Supply & fix of 6" dual scale (°F/°C), lower mount (radial), bimetal thernometer having 0.5 NPT process connection, Grade A accuracy class as per ASME B40.200, stem diameter 6.35 mm, laminated safety glass window, stainless steel 304 case, steam, process connection & joint, aluminium dial & pointer, IP67 protection, scale range 0- 60 °C complete with accessories, etc. as specified and directed.
Supply & fix of 4" bourdon tube pressure gauge conforming to EN 837-1, having copper alloy process connection & pressure element, plastic black pointer & case, plastic crystal-clear window, snap-fitted in case, accuracy class 2.5, scale range 0- 25 bar complete with accessories, etc. as specified and directed.
Supply, installation, testing and commissioning of fire damper, at least of 120 minutes fire-rating, spring activated on melting of fusible link having melting point 67.13° C complete with smoke detector / thermister, fusible link etc. and actuator as required for operation, located in the SA / RA ducts, at all fire rated crossovers (shafts, walls, etc.). along with control panel (located in such a way that the reset can easily be done), interlocked with the building management system for the fire detection or HVAC to trip / close in the event of fire/smoke in the respective zone and tested as per ULL- 555 and certified by CBRI complete all as specified and directed by engineer-in-charge. The fire dampers shall meet the following criteria: [a] Bare fire dampers with 400 mm sleeve [b] Control panel actuator, including electrical spring type actuator, remote indication of the fire damper position. [c] Interconnection wire for the fire detection & alarm system with the AHU and the smoke dampers [d] Sealing any openings around the sleeve of the fire dampers with approved fire sealant as per the specification & recommendations of the manufacturer. Motorized, spring return type, combination fire and smoke damper Control panel actuator, including electrical spring type actuator, remote indication of the fire damper position.
Motorized, spring return type, combination fire and smoke damper
Control panel actuator, including electrical spring type actuator, remote indication of the fire damper position.
Supply & fix of supply / return / exhaust air diffusers / grilles / louvers of powder coated aluminium with aluminium volume control dampers with anti smudge ring & removable core complete all as specified and directed by engineer-in-charge.
Supply & fix of FM approved highly- flexible, closed-cell thermal insulation of elastomeric foam based on synthetic rubber (NBR), laminated with 12 micron aluminium foil facing with reinforced glass scrim tested for service temperature range 0- 105 ˚C as per EN 14706, EN 14707 & EN 14304, thermal conductivity λ ≤ 0.037 W/mK at mean temperature θm = 20 ˚C as per EN 12667 & EN ISO 8497, water vapour diffusion resistance factor μ ≥ 12000 as per EN 12086 & EN 13469, water absorption by volume 0.2% as per ASTM C 1763 & ASTM C 209, Class 0 fire performance as per BS 476 Part 6: 1989, Class 1 surface spread of flame as per BS 476 7: 1997, flammability HB, V-0 as per UL- 94, having good resistance to mechanical impact, excellent resistance to ozone, oil and chemicals, zero ozone depletion potential along with adhesives and other necessary accessories complete all as specified and directed.
19 mm thick thermal insulation
13 mm thick thermal insulation
Supply & fix of FM approved fibre-free, super-silent, microbe resistant, easy to apply 10 mm thick acoustic duct lining insulation of open cell elastomeric foam based on synthetic rubber tested for acoustic performance as per EN ISO 354, EN ISO 11654: 1997 & ASTM C 423, service temperature range -20- 85 ˚C as per EN 14706 & EN 14304, thermal conductivity λ ≤ 0.047 W/mK at mean temperature θm = 20 ˚C as per EN 12667, Class 1 surface spread of flame as per BS 476 7: 1997, flammability HB, V-0 as per UL- 94, anti-microbial behaviour (no fungal growth visible with the naked eye & no bacterial growth) as per EN ISO 846, air erosion resistance (no erosion, cracking or delamination at air velocity of 10000 FPM) as per ASTM C 1071- 05, density 140- 180 kg/m3 along with adhesives and other necessary accessories complete all as specified and directed.
Security Fencing and Gate
Material & labour for drilling holes of 25 mm dia with double flute type drill bits of hilti TE-C3X to the required depth of 300 mm by hilti rotary hammer drilling machine, clearing with brush and jet of clean air. Grouting of 16 mm dia bolt to hard rock all as per manufactures instruction including providing and supply heavy duty injection adhesive hilti hit RE 500 for rebar fixing in wet/dry conditions. The system should be made of two foils consisting of resin and hardner foil pack. The chemical should have ETA, DIBT and corrosin approval. The installation and the setting instruction should be strictly followed as per the manufactures recommendations. Make:-Hilti or equivalent and complete all as specified and directed. Note Rates shall be inclusive of testing pull out test of rabars for design capacity of 8 tonne for rebars casted
Supply & fix 2.5sqmm 3core copper cable from street light pole junction box to light fitting complete all as specified and directed.
Supply & fix High Bay light 150 W with lumen efficiency not less than 100 lumen/watt, with powder coated PDC aluminum body and PC optical lenses, 5700 K CCT, pf 0.8, IP45 including all accessories and fittings for suspension from ceiling complete all as specified and directed.
BABU LAL PARIHAR
M/S Tanisha Traders
M/s godara infratech and power industries
FRIZO INDIA PVT LTD
DHARIWAL TRADERS PRIVATE LIMITED
MAHARISHI GAUTAM CONSTRUCTIONS
M/s Mohata Buildcon
Jagdish Prashad and Company
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .