SE ETC NOIDA
220 KV SUB STATION SECTOR-20 NOIDA
Replacement of damaged 33 kV main bus and jumpers connected therewith including supply at 132 kV S/S Sec-45 Noida under ETD-I Noida
2020_UPTCL_443207_1
E-T-88/ETCN/2019-20
Open Tender
Electrical Works
Item Rate
30 days
NOIDA
Please refer Tender documents.
2 documents required · 2 mandatory
₹1,770
EE ETD NOIDA
₹13,500
13 Apr 2020
4 Mar 2020
31 Mar 2020
4 Mar 2020
31 Mar 2020
4 Mar 2020
Amount
Supply
Bolted type tension fitting for Twin Moose conductor with turn buckle for 70 KN disc Insulator suitable for main bus with hardware fitting D shackle, D Socket ball hook york plate D clip tension clamp as per technical specification/sample
Bolted type tension fitting for Twin Moose conductor without turn buckle for 70 KN main bus suitable for disc Insulator with hardware fitting D shackle, D Socket ball hook york plate D clip tension clamp as per technical specification/ sample
Fired wedge type 'C' connector (RPG make) suitable for Moose to Panther conductor having 1250 Amp. capacity.
Fired wedge type 'C' connector (RPG make) suitable for Moose to Zebra conductor having 1250 Amp. capacity
Bimetallic 33 KV Isolator Clamp made of aluminium Alloy LM-6 complete with GI Nuts, Bolts and washers suitable for ACSR Twin Panther Conductor as per technical specification/sample
Bimetallic 33 KV Isolator Clamp made of aluminium Alloy LM-6 complete with GI Nuts, Bolts and washers suitable for ACSR Twin Zebra Conductor as per technical specification/sample
Bimetallic 33 KV Isolator Clamp made of aluminium Alloy LM-6 complete with GI Nuts, Bolts and washers suitable for ACSR Twin Moose Conductor as per technical specification/sample
2 Bolts 250 mm spacing, spacer for Twin Moose conductor as per technical specification/sample
2 Bolts 100 mm spacing, spacer for Twin Zebra conductor as per technical specification/sample
1 Bolts 60 mm spacing, spacer for Twin Panther conductor as per technical specification/sample
Opening / Cutting of old inter connection R, Y & B phase of 33 KV main bus I, II & III sections made of Tarantula conductor between bus section below gantries, step by step during bus-bar strengtheing work carefully as neighbor saction may be charged including opening/ cutting of PG Clamps/ Isolator Clamps etc.
Opening / Cutting of existing jumpers from 33 KV Mainbus-bar I, II & III and all associated clamps, step by step during strengthening of bus-bar of various size & capacity conductors.
Dismantling of 33 KV main old bus-bar I, II & III sections of R, Y & B phase of Tarantula conductor by lowering down and complete dismantling of its fitting etc and shifting of all old material from switch yard to store.
Stringing and proper sagging of 33 KV new main bus I, II & III sections by twin moose conductor including shifting of new material from store to working site and fitting of tension clamps, hosting of disc insulators, tension fitting, PG clamps and spacers etc. and cutting the conductors as per requirement.
Fixing of fired wedge type 'C' connector (RPG make) suitable for Moose to Panther / Moose to Zebra conductor having 1250 Amp. capacity.
Reconnection of main bus-bar droper jumpers from 33 KV new main bus I, II & III to isolator by twin Panther/Zebra/ conductor after fitting of new isolator clamps and spacers etc. including shifting of material from store.
Reconnection of main bus below the gantry in bus section step by step during replacement of 33 KV main bus I, II & III of twin moose conductor by required clamps, fittings and spacers as required to complete the work in all respect.
BARKATI ENTERPRISES
VIDHI ENTERPRISES
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .