Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹16.7 LAccepted-AOC | L1 | Accepted-AOC AS PER BOQ | |
| 2 | L2₹19.4 L+₹1.8 L (10.4%)Rejected-AOC | L2 | Rejected-AOC AS PER BOQ | |
| 3 | L3₹19.9 L+₹2.3 L (13.1%)Rejected-AOC NEAR INDUSTRIAL ESTATE THANDA PADDAR UDHAMPUR J K 182101 | UDHAMPUR | JAMMU AND KASHMIR | 182101 | L3 | Rejected-AOC AS PER BOQ | |
| 4 | L4₹19.9 L+₹2.3 L (13.2%)Rejected-AOC VILLAGE POST JAGANOO TEHSIL UDHAMPUR JAGANOO UDHAMPUR1 UDHAMPUR JAMMU KASHMIR 182124 UDYAM JK 22 0011509 | UDHAMPUR | JAMMU AND KASHMIR | 182124 | L4 | Rejected-AOC AS PER BOQ | |
| 5 | L5₹22.5 L+₹4.9 L (27.6%)Rejected-AOC | L5 | Rejected-AOC AS PER BOQ |
Tender Value
₹20.9 L
EMD Value
₹41,800
Closing Date
5 Aug 2020, 6:00 pmClosed
GE Army Dhar Road Udhampur
GE Army Dhar Road Udhampur
REPAIRS TO ROOF CHAJJAS RCC PARAPET WALL PLASTERING AND PLUMBING WORK IN OTM ACCN AT JINDRAH
2020_MES_359649_1
8066/NIT-20/2020-21
Open Tender
Miscellaneous Works
Item Rate
240 days
Jindrah under GE Army Dhar Road Udhampur
Please refer Tender documents.
5 documents required · 5 mandatory
₹500
Yes
GE Army Dhar Road Udhampur
₹41,800
Yes
16 Oct 2020
9 Jul 2020
7 Aug 2020
9 Jul 2020
5 Aug 2020
22 Jul 2020
9 Jul 2020 - 21 Jul 2020
Amount
Dismantling AC sheets of any description in roof covering including ridges, wind ties etc complete all as specified and directed.
Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and directed.
S&F rolled mild steel work in tubular trusses, purlins etc. including special shaped washer etc complete using ERW or induction butt welded tubes conforming to IS 1161-1979 Gde St-240 and painted one shop coat of zinc chromate primer paint (including preparation of surface) at contractor's workshop before fabrication complete all as specified and directed.
All as per srl item No 03, here-in-before but re-fixing & fabrication only complete all as specified and directed.
S&F pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50 thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed.
All as per srl item No 05 above, but plain galvalume sheet as in ridge, hips, valley gutter, drip etc complete all as specified and directed.
M&L for brick work with sub class 'B' bricks straight or curved on plan exc 6 mtr mean radius built in cement mortar 1:6 including demolition of existing brick work or stone/boulder masonry built in cement mortar complete all as specified and directed.
All as per srl item No 7 above but except bricks. (Note: Old usable bricks retrieved vide srl item No 7 and 8 shall be reused).
Dismantling of existing water proofing treatment (unreinforced cement concrete polymeric water proofing membrane and cement mortar) not exceeding 15 cm thickness complete all as specified and directed.
M&L for 40mm thick plain cement concrete 1:2:4 type B1 using 20mm graded stone aggregates and finishing the surfaces even and fair as in padding concrete for roof slab including mixing of water proofing compound complete all as specified and directed. (Note: WPC shall be measured and paid for separately as supply only).
M&L for rendering 10mm thick on fair faces of brick work or concrete surfaces, finished even and fair in cement mortar (1:4), using water proofing compound complete all as specified and directed. (Note: WPC shall be measured and paid for separately as supply only).
Supply only integral water proofing compound, ISI marked, complete all as specified and directed.
M&L for applying evenly a tack coat of industrial bitumen 85/25 at the rate of 1.2 kg per square metre including cleaning surfaces complete all as specified and directed.
M&L for APP based polymeric membrane minimum weight not less than 3kg/sqm and minimum 3mm thick reinforced with polyster non-woven fabric (weight not less than 150 gm/sqm) laid on roofs using butane torch, and sealing all joints after and including applying bitumenous primer @ 0.40 litre per square metre over clean RCC roof surfaces, complete all as specified and directed. Make : Hyperplas of IWL India Ltd Chennai/Texas India Ltd Gurgaon/Bengal Bitumen Pvt Ltd or its equivelant
Taking down cement plaster, any description on brick or stone or cement concrete walls including raking out joints, hacking for key, scrubbing down with water complete all as specified and directed.
M&L for 15 mm thick cement plaster on fair faces of brick work in cement mortar 1:6 finished even and smooth without using extra cement complete all as specified and directed.
M&L for 15 mm thick rendering on other than fair faces of brick work or cement concrete surfaces in cement mortar 1:4, finished fair and even without using extra cement complete all as specified and directed.
M&L for 5 mm thick cement plaster on fair faces of brick work or concrete surfaces in ceiling using cement mortar 1:4 finished even and smooth without using extra cement complete all as specified and directed.
M&L for two coats of cement base paint over a coat of primer including preparation of new plastered surfaces complete all as specified and directed.
M&L two coats of oil bound distemper over a coat of primer including preparation of new plastered surfaces complete all as specified and directed.
M&L for applying three coats of white washing on new/undecorated wall surfaces, including preparation of new plastered surfaces, complete all as specified and directed.
M&L for applying two coats of synthetic enamel paint (1st grade) over a coat of red oxide primer on new steel surfaces of any description over 10 cm width or girth including preparation of surfaces complete all as specified and directed.
M&L for applying one coat of synthetic enamel paint over old painted steel & Iron surfaces of any description, not otherwise described over 10cm width or girth, including preparation of surfaces complete all as specified and directed.
Dismantling timber scantlings under 40 sqcm in section, as in fillets, rails, rafters, purlins etc unframed work complete all as specified and directed.
Dismantling wall and ceiling boards (fibre, pulp, gypsum, POP, insulation, etc.) or insulation boards/slabs/blankets, any thickness, including cover fillets complete all as specified and directed.
M&L for 4mm thick Asbestos cement plain building boards fixed to MS work/timber framework with screws complete all as specified and directed.
M&L for providing designer ceiling of size 600x600x4mm thick, pre painted ceiling board tiles of approved texture, laid on hot dipped galvanised iron imposed grid system with 24mm wide T-section, exposed flanges which shall be powder coated white. The frame work shall comprises of main runnder made from 0.33mm thick GS sheet and of size 24x32x300mm and spaced at 1200mm centre to centre fixed to the structural soffits by approved hangers at 1200mm maximum centres. Hangers of GI wire, 4mm dia to be fixed by approved rawl plug, level and justers and screws etc. The last hanger at the end of feach main runner shall not be greater than 450mm from adjacent wall. Flush fitting of 1200mm long cross tee (with double stitching) to be interlocked between main runner at 600mm to kbe supported independently. 600x600mm modules to be formed by fitting 600mm long cross tee centrally between the 1200mm cross tee. Tee, perameter wall angle shall be of 0.45mm thick GS sheet complete all as specified and directed. Make : Saint Gobain/Everest.
M&L cleaning and removing all scale and dirt etc from tanks and from mouths of circulating pipes etc of capacity exc 250 & not exc 500 ltrs complete all as specified and directed.
M&L cleaning and removing all scale and dirt etc from tanks and from mouths of circulating pipes etc of capacity exc 500 & not exc 1000 ltrs complete all as specified and directed.
S&F rotational moulded polyethylene water storage tanks of 500 ltrs capacity double layer (cylinderical vertical with closed top) hoisted and fixed in position all as specified in SSR Part-I including dismantling of existing water tank complete all as specified and directed.
S&F rotational moulded polyethylene water storage tanks of 1000 ltrs capacity double layer (cylinderical vertical with closed top) hoisted and fixed in position all as specified in SSR Part-I including dismantling of existing water tank complete all as specified and directed.
Refixing existing water tanks of exceeding 250 ltrs and not exceeding 500 ltrs capacity includind dismantling of existing water tank complete all as specified and directed. (Note: Old usable water tanks retrieved vide srl item No 20 and 22 shall be reused).
Refixing existing water tanks of exceeding 500 ltrs and not exceeding 1000 ltrs capacity includind dismantling of existing water tank complete all as specified and directed. (Note: Old usable water tanks retrieved vide srl item No 21 and 23 shall be reused).
S&F ball valve high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball screwed for iron pipe and fixed of bore of dia of pipe 20mm (Min wt 210gm) complete all as specified and directed.
S&F 20mm bore GI pipe medium grade galvanised with all fittings fixed to walls, laid in floors and ceilings etc including taking up or down old steel tubing and connections complete all as specified and directed.
S&F 15mm bore GI pipe medium grade galvanised with all fittings fixed to walls, laid in floors and ceilings etc including taking up or down old steel tubing and connections complete all as specified and directed.
M&L for 100mm thick plain cement concrete 1:2:4 type B1 using 20mm graded stone aggregates and finishing the surfaces even and fair as in padding concrete to roof slab for water tank including mixing of water proofing compound complete all as specified and directed. (Note: WPC shall be measured and paid for separately as supply only).
Demolition of cement concrete (reinforced) other than ground floors as in beams, stair cases, landings, chajjas and similar suspended work (reinforcement cut as required to facilitate demolition) complete all as specified and directed.
Use and waste of form work to rough finished surface of sides and soffits of suspended slabs such as roof slabs, floor slabs, landings, chajjas and similar work; not exceeding 200mm thick (Horizontal or sloping) complete all as specified and directed.
Use and waste of form work to rough finished surfaces of edges of concrete flats, treads, RCC/PCC bands in walls, chajjas, horizontal or sloping and similar work exc 10cm but n exc 20cm wide complete all as specified and directed.
S&F mild steel TMT bars 10 mm dia and over cut to length, bent to shape required including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.90 mm dia or securing with clips complete all as specified and directed.
All as per srl item No 41 above but 6 to 8 mm dia complete all as specified and directed.
M&L reinforced cement concrete type B-1 1:2:4 (using 20 mm graded stone aggregates) as in slabs supported on walls, chajjas, beams, landings, deck slab and like complete all as specified and directed.
SHANTI ENTERPRISES
K S BUILDERS
NARESH KUMAR KHAJURIA
Rakesh Kumar Malia
MandeepConstructionCo
M/S SANJAY STEEL WORKS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .