Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹28.8 LAccepted-AOC | L1 | Accepted-AOC REASONABLE | |
| 2 | L2₹31.8 L+₹2.4 L (8.00%)Rejected-Finance FLAT NO 10 S NO 98 PLAT NO 78 SAI SAYAJI PARK A RIGHT BHUSARI COLONY KOTHRUD PUNE 411 038 | PUNE | MAHARASHTRA | 411038 | L2 | Rejected-Finance HIGH RATE | |
| 3 | L3₹34.6 L+₹5.2 L (17.8%)Rejected-Finance | L3 | Rejected-Finance HIGH RATE |
Tender Value
₹40 L
EMD Value
₹80,000
Closing Date
26 Jul 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
SHRI PRAVEEN KUMAR, IDSE
GE KHADAKWASLA, NDA KHADAKWASLA, PUNE-23
REPAIRS TO ROOF MANGALORE TAYLOR TILES ROOF DRAIN WATER PIPES AND OTHER REQD WORK IN ZONE B AREA AT NDA KHADAKWASLA
2023_MES_606234_1
8723/E8
Open Tender
Civil Works
Item Rate
180 days
GE KHADAKWASLA
AS PER TENDER DOCUMENT
9 documents required · 9 mandatory
₹500
GE KHADAKWASLA
₹80,000
Yes
20 Nov 2023
27 Jun 2023
28 Jul 2023
27 Jun 2023
26 Jul 2023
14 Jul 2023
27 Jun 2023 - 13 Jul 2023
Amount
Dismantling of single layer Mangalor/Taylor pattern tiles in roofing complete all as specified and directed.
M&L for providing roof tiles Mangalore/Taylor pattern interlocking at side joints, laid dry in patches where required complete all as specified and directed Notes for item No.1&2 : (i) The height at which wk is to be carried out is exc 6mtr and n exc 20mtr, (ii)necessary scafolding required deemed to to included in rates quoted
All as per item No. 2 above item No 2 but except tiles
Dismantling of single layer Mangalor/Taylor pattern tiles in roofing for ridge or hip tiles complete all as specified and directed.
M&L for ridge or hip tiles to suit Mangalore/Taylor pattern of roofing tiles, bedded and jointed in cement mortar (1:6) where required complete all as specified and directed. Notes for item No. 4 & 5 : (i) The height at which wk is to be carried out is exc 6mtr and n exc 20mtr, (ii) necessary scafolding required deemed to to included in rates quoted
All as per item No. 5 above but except ridge tiles
Dismantling of battans for tiles of any size including tilting fillets spacing exc. 15 cm complete all as specified and directed.
M&L for second class hard wood clean sawn battens at 30 cm centre, sectional area exc 5 & n.exc 15 sqcm complete all as specified and directed.
Ditto all as per item No. 7 above but except battens
Dismantling timber scantling 40 Sqcm and over in section and at any position as in unframed work complete all as specified and directed.
M&L for second class hard wood in scantling exc 40 Scm in area clean sawn for unframed work complete all as specified and directed.
Fixing only for second class hard wood in scantling clean sawn for unframed work complete all as specified and directed. Note:- Timber scantling obtained from Item No 10 shall be re-used.
Dismantling timber scantling under 40 Sqcm in section and at any position as in unframed work complete all as specified and directed.
M&L for second class hard wood plain fillets section exc 13 Sqcm and b not exc 25 Sqcm, square, rectungular or tringular in section, clean sawn, secured with nails or brads for unframed work complete all as specified and directed.
Dismantling boarding, any description, fixed in any position with nails complete all as specified and directed.
M&L in repairs for second class hard wood 20 to 25 mm thick weather boarding clean sawn, rebated on thick edge to give 20 mm laps and fixed, complete all as specified and directed. Notes for item No.15 & 16 : (i) The height at which wk is to be carried out is exc 6mtr and n exc 20mtr, (ii)necessary scafolding required deemed to to included in rates quoted
Ditto all as per item No 16 above but except boarding Note:- Boarding obtaining from Item No 15 shall be re-used.
Corbel & brackets Repairs S&F in repairs wooden brackets over stone corbels of size 1.21x1.11x0.81 mtr and thickness 5.5'' decorative type moulded or as per the size and design of existing bracket, madeup of 1st class teak wood incl carefully removing the existing all as specified and as directed.
M&L for repairs to stone corbels using SS dowels and epoxy resin complete all as specified and as directed
M&L for complete removal of exisisting treatment of truss and applying two coats of synthetic enamel paint over a coat of red oxide complete all as specified and directed.
S&F in repairs Polycarbonate bird spike ( pigeon control spike) of existing shape and size, fixed with nails, screws or any suitable means at Dome of Sudan block, Vyas Libray etc complete all as specified and directed. Note: Quoted Rate is deemed to be included for necessary scafolding required.
Demolition of PCC block /stone boulder masonry built in cement mortar or cement lime mortar complete all as specified and directed.
M&L for precast cement concrete block masonry exc. 10 cm width with solid blocks of PCC ,type C 1 (1:3:6) (20mm graded stone agg)and setting in cement mortar (1:6) complete all as specified and as directed
M&L for brickwork with subclass 'B' bricks, straight or curved on plan to any radius in half brick thick walls, built in cement mortar (1:4) complete all as specified and directed.
Dismantling plain or corrugated steel sheeting, any gauge, thickness complete all as specified and directed.
S&F 0.63mm thick galvanised, corrugated mild steel sheeting with two corrugations side lap, fixed with cranked hook bolts in roofs, walls etc class-2 with zinc coating grade 275 complete all as specified and directed.
S&F for 0.63mm thick plain galvanised, mild steel sheeting as in ridge, hips, valley gutters, drip and straight flashings class-2, with zinc coating grade 275 complete all as specified and directed.
S&F 0.50 mm thick TCT (total coated thickness) pre-coloured galvalume sheets with minimum base metal thickness of 0.45 mm, single skin high rib/multi rib profile galvalume sheeting having 1000-1020 mm width and 28-30 mm high crest @ maximum 250-255 mm pitch (centre) with sheets manufactured out of 0.50 mm this TCT (total coated thickness) high tensile galvalume sheets having tensile strength 550 MPA with 18-20 micron top coat over 5 micron primer and 8-10 micron alkyld backer zinc aluminium alloy AZ-150, sheets having a dip metallic zinc (43.5%0 aluminium (55%) & silicon (1.5%) with total mass coating of 150 gms/sqm on both sides, having wide pans with minimum 3 small stiffening ribs for effective water shedding and special male/female ends with full return legs on laps for purlin support and fixed as per existing profile of roof complete all as specified and directed.
S&F 0.71 mm thick plain aluminium sheeting, alloy 31000 H-4 in ridges, hips, valley gutter, drip and strainght flashing (length and girth as fixed) etc complete all as specified and directed
S&F RMP sheeting 1.5 mm thick with 1.5 corrugation side lap fixed with coach screw and PVC washer in roof, wall etc complete all as specified and directed.
Dismantling of ceiling boarding in description fixed in any position complete all as specified and directed.
M&L for 4mm thick Non Asbestos cement plain sheet 600 x 600 for ceiling and including anodized aluminium grid work 610 x 610 mm with using 36.5mmx23.5mmx 1.5mm thick main tee, 23.5 x23.5mmx1.28mm cross tee and 25x25x1.5mm angles fixed to perimeter of wall for false ceiling including necessary supporting hanger with 3.0mm dia GI wire and 'J' bolts washer nuts for securing frame work to ceiling suspended @ 120 cm C/C both ways, size of grid shall be 610x610mm complete all as specified and directed.
S&F in repair 12mm thick Prelaminated particle board, interior grade, prelaminated one side with decorative choice lamination & other side balancing white lamination, fixed with screws to timber frame /snap grid work complete all as specified and directed.
S&F 20mm thick second class hardwood, boarding as in ceilings,clean sawn with butt joints & fixed with nails in any situation complete all as specified and directed.
M&L for painting two coats of Synthetic enemal paint over a coat of pink primer on new wooden surfaces complete all as specified and directed.
M&L for one coats of synthetic enamel painting to wooden surfaces including preparation of old surfaces complete all as specified and directed..
M&L for taking down existing water proofing treatment of any description and layers from wall/roofs including screed bed or bedding layers of mortar of any complete and cleaning the surfaces free from dust and scrubbing down with water complete all as specified and clearing the premises all as directed. Notes :(i) The height at which wk is to be carried out is exc 6mtr and n exc 20mtr, (ii)necessary scafolding required deemed to to included in rates quoted
Demolition of cement concrete (unreinforced)/brickbat work incl china mosiac used for roof treatment of any description and in any position not otherwise specifically provided for padding layer for roof treatment/ at junction of wall and chajjas and removing out of MOD land complete all as specified and directed.
M&L for PCC (1:2:4) type B-0 (using 12.5mm size graded stone aggregates) avg thickness 40mm as in padding on roof any thick including water proofing compound @ 3% by weight of cement shall be caried out complete all as specified and directed Note WPC shall be measured and paid separatsly under respective item
M&L for rendering 10mm thick on fair faces of brick work or concrete surfaces in CM 1:3 using water profing @ 3% of cement Note: WPC shall be measured and paid separately under respective item
M&L for preparing plastered surfaces @ 0.25 kg/Sqm with primer and applying water proofing treatment on roof /wall surfaces, edges and vertical surfaces using APP modified membrane 3 mm thick with non woven polyster mat as reinforcement weighing not less than 3.5 Kg/Sqm using butane torch by torch on application with a side lap of 10cm and 15cm end lap, and applying one coat of aluminium top reflecting coating above the membrane complete all as specified and directed.
Supply only intergal water proofing compound complete all as specified and directed.
M&L for preparing old plastered / concrete surfaces of roof/wall with wire brush and with water thoroughly to remove all dust/dirt and loose particles and applying 3 coats of Dr fixit New coat / Asian paint damp proof on roof surfaces including crack seal sealent if required at crack portion of roof/wall all application as per manufacturer instructions and including waranty certificate provided by applicator/company complete all as specified and directed.
Taking down GI tubing including all necessary connections including cleaning for refixing, 15 mm bore pipe complete all as specified and directed
Ditto all as per item No 44 above but 20 mm dia pipe
Refixing old steel tubing 15 mm bore pipes and connections in new or old positions (walls, ceiling, floors etc) complete all as specified and directed.
Refixing old steel tubing 20 mm bore pipes and connections in new or old positions (walls, ceiling, floors etc) complete all as specified and directed.
M&L for fixing GI tubing 15mm dia medium grade with all fittings and fixtures like GI tees, elbows, diminishing pieces, cut pieces etc complete fixed to wall, ceiling or laid in floors complete all as specified and directed.
Ditto all as per item No 48 above but 20 mm dia pipe.
Disconnecting existing water tanks setting aside (or lowering if required) for repairs, cleaning etc and hoisting if required, reconnecting and refixing in position all as specified in SSR for capacity 500 ltr & upto & including 1000 lts complete all as specified and directed.
Dismantiling water tank exc 500 lit and not exc 1000 lit and removing complete all as specified and directed.
S&F three layered Rotational moulded polyethylene water storage 1000 litres tank (cylindrical vertical with closed top) hoisted and fixed in position and Including 20 mm dia PTMT float valves complete all as specified in SSR part I complete all as specified and directed.
S&F three layered Rotational moulded polyethylene water storage 500 litres tank (cylindrical vertical with closed top) hoisted and fixed in position and Including 20 mm dia brass float valves complete all as specified in SSR part I complete all as specified and directed.
Dismantling of any dia CI /PVC or reinforced concrete drain pipes jointed in cement mortar and taking out of wall/trenches, if required complete all as specified and directed.
M&L for providing cast iron soil, waste and vent pipes in any length with or without ears with cement joints fixed to walls using pipes 100 mm bore complete all as specified and directed.
M&L for providing cast iron, soil & waste and vent pipes in any length, with or without ears with cement joints fixed to walls using pipes 75 mm bore complete all as specified and directed.
S&F of CI bends (any radius) diminishing pieces or taper,100mm bore complete all as specified & directed.
S&F of CI bends (any radius) diminishing pieces or taper,75 mm bore complete all as specified & directed.
S&F rainwater PVC (SWR) 110mm dia pipes as in single socketed in any length with rubber ring joints fixed to walls complete all as specified and directed.
S&F for 75mm dia PVC (SWR) grade single socketed pipes in any length complete with rubber ring joints fixed to wall complete all as specified and directed
S&F PVC (SWR) 110mm dia bends any radius complete all as specified and directed.
S&F for 75mm dia PVC (SWR) bends any radius complete all as specified and directed
Taking down eaves gutters and rainwater pipes (any size or pattern), including all fittings, heads, shoes, bends, swan-necks, etc., including cleaning or refixing or removal to Store (measured overall as fixed along the centre line over fittings and accessories) complete all as specified and directed.
S&F Mild steel sheet eaves gutters, galvanised class 3, half round with rounded edges Dia 150mm, thickness of sheet 1.25mm including holderbats, distance pieces, etc. complete all as specified and directed.
Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and directed.
S&F Framed work for framed chajja, grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work con- forming to Fe.290.Gde-E-165 complete all as specified and directed.
S&F Bands, straps, supports or stays for rainwater, ventilating pipes, including bolts, if required: hooks (stay), heavy, for large gates; hook and pintle hinges: large hasps and staples; chains; hand made sliding bolts; clamps; hold fasts; wall ties; hooks for hanging fans; plain angle cleats for securing purlins to wood trusses or rafters; knee piece inserts; two way and three way straps, plate washers and similar small articles conforming to Fe-290 Gde-E-165 complete all as specified and directed.
M&L for 16 to 18mm thick granite (of any type any colour) work (table rubbed & polished ) in steps, jambs, pillars, window door - cills/jambs, cooking platforms and like in cement morter (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite including dismanting of existing complete all as specified & directed.
Taking down old cement plaster on brick or stone walls, etc including raking out joints, hacking for key, scrubbing down with water, etc complete all as specified and directed.
M & L for 15 mm thick rendering on fair faces or brick work or concrete surfaces in cement mortar (1:4) surface finished even and smooth (with out using extra cement) complete all as specified and directed.
M&L for applying two or more coats of 100% premium acrylic emulsion paint having VOC less than 50 gms / litres and UV resistance as per complete all as specified and directed
M&L for preparation of new steel surfaces and applying two coats of synthetic enamel paint over a coat of redoxide primer complete all as specified and directed.
Sunil Constructions
DARSHAN ENTERPRISES
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .