Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹6.8 LAccepted-AOC | ₹6.8 L | L1 | Accepted-AOC Awarded |
| 2 | L2₹7.4 L+₹54,741.92 (8.03%)Rejected-AOC | ₹7.4 L+₹54,741.92 (8.03%) | L2 | Rejected-AOC Reject |
| Sl No | Description | Qty | Unit | Vijay Pannu L2 | Sunil Kumar Contractor Bhambhewa L1 |
|---|---|---|---|---|---|
| 1.00 | Supply and jointing four core Aluminum armour cables of approved make insulated and sheathed with PVC for starter pannel box including cost of jointing, materials as well as carriage, loading, unloading etc. complete in all respect up to the entire satisfaction of Engineer- in-Charge. 35 mm 4 core Aluminums armour cable | 200 | Metre | 650 ₹1,30,000 | 580 ₹1,16,000 Lowest |
| 2.00 | Drilling of 450 mm dia of bore through bokky type instrument complete in all respect including charges for shifting of infrastructures as per IS Code 12818: 1992 | 80 | Metre | 950 ₹76,000 | 850 ₹68,000 Lowest |
| 3.00 | Hire charges for Hydraulic excavator/Loader like JCB/Pock lain, Hitachi etc with all accessories having bucket
capacity Hire Charges for excavator with over 0.75 cum bucket capacity | 6 | Per Hour | 6,000 ₹36,000 | 5,000 ₹30,000 Lowest |
| 4.00 | Providing and fixing 300 mm M.S. cap on top of bore as for suitable pipe with nut and bolt complete in all respect as per directions of Engineer-in-charge | 2 | Each | 2,000 ₹4,000 | 1,500 ₹3,000 Lowest |
| 5.00 | Providing and fixing of 200 Amp. Main switch complete in all respects. | 2 | Each | 13,000 ₹26,000 | 12,500 ₹25,000 Lowest |
| 6.00 | Providing and fixing UPVC cap for 11` (275 mm) outer dia UPVC pipe (10kg/cm2) duly ISI marked IS Code 12818:1992 complete in all respect as per directions of Engineer-in-charge | 2 | Each | 950 ₹1,900 | 850 ₹1,700 Lowest |
| 7.00 | Providing and lowering 11` (275 mm) outer dia UPVC filter Jali (10 Kg/CM2) duly ISI marked IS Code 12818:1992 complete in all respect as per directions of Engineer-in-charge | 60 | Metre | 90 ₹5,400 | 80 ₹4,800 Lowest |
| 8.00 | Providing and lowering 11` (275 mm) outer dia UPVC pipe (10 Kg/CM2) duly ISI marked IS Code 12818:1992 complete in all respect as per directions of Engineer-in-charge | 80 | Metre | 1,700 ₹1,36,000 | 1,650 ₹1,32,000 Lowest |
| 9.00 | Providing and lowering of u-PVC coloumn pipes in 3.05 m length, threading both side with socket (Class Heavy), gaskets, lowering into tubewells and testing including carriage, loading, unloading etc. complete in all respects to the satisfaction of Engineer-in-Charge (Make Ashirwad, Finoexpipes, Supreme, ISI Marked) 80 mm i/d) | 20 | Each | 3,700 ₹74,000 | 3,500 ₹70,000 Lowest |
| 10.00 | Supplying, erection, testing and commissioning of submersible pumping sets as per BIS SPECIFICATION No. 8034-1989 (as amended upto date for pumps) and IS 9283-1979 (as amended upto date for motor) the pump motor sets should be capable of pumping clear fresh cold water having characteristics as specified in Clause-4 of IS 8034-1989 and Clause 4.1 of IS 9283-1979
LPM 240 Head 70 BHP 7.50 | 2 | Each | 55,000 ₹1,10,000 | 52,000 ₹1,04,000 Lowest |
Tender Value
₹5.9 L
EMD Value
₹11,887
Closing Date
15 Sept 2025, 3:00 pmClosed
BHANU PARKASH SHARMA
Jind PHED No. 1
2 Nos. Shallow tubewell at village Barsola
2025_HRY_469974_1
202515522711 CED5 44F4 9424 4E3B3605902E568PUH
Open Tender
Civil Works
Works
60 days
BARSOLA
4 documents required · 4 mandatory
₹1,000
₹11,887
Yes
3 Dec 2025
4 Sept 2025
15 Sept 2025
4 Sept 2025
15 Sept 2025
4 Sept 2025
Amount
Supply and jointing four core Aluminum armour cables of approved make insulated and sheathed with PVC for starter pannel box including cost of jointing, materials as well as carriage, loading, unloading etc. complete in all respect up to the entire satisfaction of Engineer- in-Charge. 35 mm 4 core Aluminums armour cable
Drilling of 450 mm dia of bore through bokky type instrument complete in all respect including charges for shifting of infrastructures as per IS Code 12818: 1992
Hire charges for Hydraulic excavator/Loader like JCB/Pock lain, Hitachi etc with all accessories having bucket capacity Hire Charges for excavator with over 0.75 cum bucket capacity
Providing and fixing 300 mm M.S. cap on top of bore as for suitable pipe with nut and bolt complete in all respect as per directions of Engineer-in-charge
Providing and fixing of 200 Amp. Main switch complete in all respects.
Providing and fixing UPVC cap for 11` (275 mm) outer dia UPVC pipe (10kg/cm2) duly ISI marked IS Code 12818:1992 complete in all respect as per directions of Engineer-in-charge
Providing and lowering 11` (275 mm) outer dia UPVC filter Jali (10 Kg/CM2) duly ISI marked IS Code 12818:1992 complete in all respect as per directions of Engineer-in-charge
Providing and lowering 11` (275 mm) outer dia UPVC pipe (10 Kg/CM2) duly ISI marked IS Code 12818:1992 complete in all respect as per directions of Engineer-in-charge
Providing and lowering of u-PVC coloumn pipes in 3.05 m length, threading both side with socket (Class Heavy), gaskets, lowering into tubewells and testing including carriage, loading, unloading etc. complete in all respects to the satisfaction of Engineer-in-Charge (Make Ashirwad, Finoexpipes, Supreme, ISI Marked) 80 mm i/d)
Supplying, erection, testing and commissioning of submersible pumping sets as per BIS SPECIFICATION No. 8034-1989 (as amended upto date for pumps) and IS 9283-1979 (as amended upto date for motor) the pump motor sets should be capable of pumping clear fresh cold water having characteristics as specified in Clause-4 of IS 8034-1989 and Clause 4.1 of IS 9283-1979 LPM 240 Head 70 BHP 7.50
Bidder Name
Amount
Vijay Pannu (GSTN-NA) BID ID -1335535
Sunil Kumar Contractor Bhambhewa (GSTN-NA) BID ID -1335435
Vijay Pannu (BID ID -1335535)
Vijay Pannu (BID ID -1335535)
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .