Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Infra Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹22.2 LAccepted-AOC | L1 | Accepted-AOC Accepted | |
| 2 | L2₹27.9 L+₹5.2 L (23.0%)Rejected-Finance | L2 | Rejected-Finance Rejected due to highest rate quoted | |
| 3 | L3₹31.8 L+₹9.1 L (40.2%)Rejected-Finance A 47D RAM DUTT ENCLAVE UTTAM NAGAR NEW DELHI 110059 | WEST | DELHI | 110059 | L3 | Rejected-Finance Rejected due to highest rate quoted | |
| 4 | L4₹31.9 L+₹9.2 L (40.8%)Rejected-Finance N A | NEW DELHI | DELHI | 110001 | L4 | Rejected-Finance Rejected due to highest rate quoted |
Tender Value
₹42 L
EMD Value
₹84,000
Closing Date
16 Mar 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (AF) GURGAON
GE (AF) GURGAON
ADDITION ALTRATION TO BUILDING NO P96 AND P97 AT AF RAJOKRI AND PROVN OF PARTITION WALL ALONGWITH WOODEN DOOR FOR SEPARATION OF BOYS AND GIRLS TOILET AT KV SCHOOL RAJOKRI UNDER GE AF GURGAON
2024_MES_642915_1
GE/GUR-/NIT-79/2023-24
Open Tender
Civil Works
Item Rate
240 days
GE (AF) GURGAON
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE (AF) GURGAON
₹84,000
1 Apr 2024
17 Feb 2024
18 Mar 2024
17 Feb 2024
16 Mar 2024
2 Mar 2024
Amount
Demolition of Mud in roofs, any thickness including plastering and leeping, (whether full thickness removed etc complete all as specified and as directed.
M&L for 50 mm thick PCC (1:2:4) type B-0 (Using 12.50 mm graded stone aggregate) as in roof padding complete all as specified and as directed.
M&L for 15 mm thick plaster in cement mortar (1:4) mixed with water proofing compound on roof slabs finished even and smooth (without using extra cement) after cleaning of roof surfaces with wire brushes complete all as specified and as directed. Notes : WPC shall be measured and paid seperately.
M&L for water proofing treatment with APP (Atactic Polypropylene) modified polymeric membrane over roof consisting of cleaning of concrete or plaster surface of roof & parapet walls and applying evenly a bitumen primer confirming to IS 3488 @ 0.40 Kg per sqm followed by a tack coat @ 1.2 kg per sqm using 85/25 grade industrial hot blow bitumen over it laid with APP modified polymeric water proofing membrane minimum weight 3.6 kg/sqm reinforced with non woven polyester fabric (weight not less than 160 grams per sqm) unrolled and bonded to substrata with logitudinal and end laps 100 mm as per manufacturer's instructions complete all as specified and as directed.
M&L for Cutting grooves in brick wall, 75mm wide and 65mm deep and shaping horizontal face of groove with cement mortar 1:3 complete all as specified and as directed.
M&L for providing plain cement concrete (1:2:4) type B0 (using 12.5 mm graded crushed stone aggregate) as in coping or roof kerbs on roof chamfered on edge including trowelling slightly complete all as specified and as directed.
M&L for screed bed or bedding layer of mortar 15 mm thick in cement mortar (1:4) for laying cement concrete roof tiles complete all as specified and as directed.
M&L for Cement concrete tiles 25cm x 25cm x 22 mm thick, machine pressed; set jointed and pointed in neat cement slurry in floors, and cut and polished, set with grey cement and pigments complete all as specified and as directed.
M&L for brick work with sub class 'B' brick, straight or curved on plan exc 6.0 mtr mean radius built in cement mortar 1:6 etc complete all as specified and as directed.
M&L for half brick work with sub class 'B' brick, straight or curved on plan exc 6.0 mtr mean radius built in cement mortar 1:4 etc complete all as specified and as directed.
M&L for Mild steel round bars 6 to 8 mm dia, cut to length, bent to shape required including cranking, bending for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips etc complete all as specified and as directed.
M&L for providing reinforced cement concrete (1:2:4) type B1 (using 20mm graded crushed stone aggregate) as in beams, cantilevers, bressummers, lintels over 1.5m span complete all as specified and as directed.
M&L for Mild steel TMT bars 10 mm dia and over, cut to length, bent to shape required including cranking, bending for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips etc complete all as specified and as directed.
All as per item No 13 here-in-before but 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders complete all as specified and as directed.
Use and waste formwork to sides and soffits of floor or roof beams, beam haunchings,girders, bressummers,lintels, cantilevers, shelvesincluding supports,overhangs,etc. also splays between floors in rough finished flat surfaces and etc complete all as specified and as directed.
Demolition of cement concrete (un-reinforced) in ground floors and pavings n exc 15 cm thickness (below or above ground level) complete all as specified and as directed.
M&L for PCC (1:2:4), type B2 (using 20 mm graded crushed stone aggregate), 100 mm thick as in flooring finished even & smooth without using extra cement all as specified. ( add recron 3s fibre qty as per manufacturers nstruction when the concrete is green and fresh and rates are included in this item) complete all as specified and as directed.
M&L for plastic dividing strip,1.5 mm thick, 100 mm wide and inserted in position, conform to design complete all as specified and as directed.
M&L for PCC 1:2:4 type B1 (using 20mm graded stone aggregates) as in lintels upto 1.5m clear span, cills, steps, seismic and other similar bands, plinth courses, coping, bed plates and the like including weathering, slightly rounded or chamfered angles and throating including necessary form work, complete all as specified.
M&L for providing reinforced cement concrete (1:2:4) type B1 (using 20mm graded crushed stone aggregate) as in Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and as directed.
Use and waste formwork to soffits of suspended slabs such as roof slabs, floorslabs, landings and similar work not exceeding 200 mm thick rough finished in flat surface complete all as specified and as directed.
M&L for 20 mm thick Granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, win dow-cills, cooking plat forms and like in cement mortar (1:4) including point ing in white cement (1:2) us ing marble dust with admix ture of pigment to match with shade of granite complete all as specified and as directed.
S&F powder coated anodized aluminum frame for partition, doors, windows, ventilations with one or more rebates including joining cleat for fixing etc. complete all as specified and as directed.
S&F powder coated anodized aluminum door shutters, aluminum section weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber neoprene packing, aluminium anodized handles suitable size 2 Nos in each door,100 mm long aluminum anodized hinges (3 Nos), anodized aluminum snap beading screws etc. complete all as specified and as directed.
S&F powder coated Anodised aluminium window and ventilator shutters, fixed/side hung type without sash bars, aluminium sections weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, anodised aluminium fittings such as peg stays 150mm long (1 No.). hinges type B-21 100mm long (2 No.) suitable handle (1 No.) complete all as specified and as directed.
S&F Anodised aluminium grill (anodised transparent or dyed to required shade according to IS: 1868 with minimum anodic coating of grade AC 15) of approved design/pattern, with approved standard section and fixed to the existing window frame with C.P. brass/ stainless steel screws @ 200 mm centre to centre, including cutting the grill to proper opening size for fixing and operation of handles and fixing approved anodised aluminium standard section around the opening, complete all as specified and as directed.
S&F for 5.50 mm thick sheet glass ordinary quality and glazing each pane fixed with neoprene rubber gasket in aluminium frame work complete all as specified and as directed.
S&F for 4.8/5.0 mm thick sheet glass ordinary quality and glazing each pane n exc 0.50 Sqm fixed with neoprene rubber gasket in aluminium frame work complete all as specified and as directed.
S&F for 4.80/5.0 mm thick frosted glass ordinary quality and glazing each pane n exc 0.50 Sqm fixed with neoprene rubber gasket in aluminium frame work complete all as specified and as directed.
S&F for Stainless steel wire cloth, 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staple including necessary beading complete all as specified and as directed.
S&F 9 mm thick prelaminated particle board exterior grade in bottom panel of Aluminium door including rubber gasket, aluminium glazing clips complete all as specified and as directed.
S&F aluminium (Die cast) body Door closer hydraulically regulated, designation No. 2, universal type, suitable for door shutters of 701 to 850 mm in width and of weight between 36 to 60 kg and fixed complete all as specified and as directed.
S&F Mortice lock, vertical type of brass 100 mm 4 Levers with duplicate keys complete all as specified and as directed.
M&L for guniting work to RCC work in column, flooring, side walls, beam, slab, etc by removing loose concrete cover etc, cleaning of surface with wire brush and applying epoxy paint to rusted reinforcement and S&F welded wire mesh fabric or wire net less than 95 X 95X 3 mm adhesive, plaster grade for concrete admixture 1 part of cement and 3.5 part of sand and average thickness 40 mm and making the surface even including 15mm thick plastering in cement mortar (1:4) on brick or concrete surfaces including finishing the surfaces even and smooth, without using extra cement plumb and making surface true to geometry in line and including necessary form work to be carried at upto double storey building Note.- Where ever reinforcement required will be measured and paid seperatly etc complete all as specified and as directed.
Taking down cement plaster on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water, etc and including removal of debris and rubbish from the site complete all as specified and as directed.
M&L for 10 mm thick rendering in cement mortar (1:3) on vertical surfaces for backing of tiles etc complete all as specified and as directed.
M&L for Glazed ceramic coloured tiles in vertical surface 350x 250x 7 mm/ 450X 350X 7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match complete all as specified and as directed.
M&L for rendering 15 mm thick in cement mortar (1:6) on brick work or concrete surfaces finished even and smooth (without using extra cement) complete all as specified and as directed.
M&L for 15 mm thick plastering in two layers (10+5) mm in cement mortar (1:4) on brick or concrete surfaces including rendering on fins, fascias, chajja, parapets etc and finishing the surfaces even and fair (without using extra cement), top layer shall be with WPC as per manufacturer's instruction complete all as specified and as directed. Note: WPC shall be measured and paid separately.
M&L for rendering 10mm thick in cement mortar (1:3) as in ceilings finished even and smooth (without using extra cement) complete all as specified and as directed.
Supply only intergral water proofing compound ISI Marked complete all as specified and as directed.
M&L for preparation of newly plastered or unplastered/undecorated surface of wall and applying two or more coat distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gms/litre, of approved manufacturer, of required shade and colour complete, as per manufacturer's specification complete all as specified and as directed.
M&L for Complete removal of existing surfaces of wall and applying two or more coat distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gms/litre, of approved manufacturer, of required shade and colour complete, as per manufacturer's specification complete all as specified and as directed.
M&L for preparation of newly plastered or unplastered/undecorated surface of ceiling and applying two or more coat distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gms/litre, of approved manufacturer, of required shade and colour complete, as per manufacturer's specification complete all as specified and as directed.
M&L for Complete removal of existing surfaces of ceiling and applying two or more coat distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gms/litre, of approved manufacturer, of required shade and colour complete, as per manufacturer's specification complete all as specified and as directed.
M&L for preparation of newly plastered surfaces of wall and applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces complete all as specified and as directed.
M&L for Complete removal of existing surfaces of wall and applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces complete all as specified and as directed.
M&L for providing 1-3mm thick wall care putty on wall before applying oil bound distemper and making the surface uniform complete all as specified and as directed.
M&L for providing 1-3mm thick wall care putty on ceiling before applying oil bound distemper and making the surface uniform complete all as specified and as directed.
M&L for preparation of newly plastered surfaces of wall and applying two coats of cement base paint on walls complete all as specified and as directed.
M&L for Complete removal of existing treatment from external surfaces of walls, parapets, fins/ facia, chajjas by wire brushing and washing, rubbing down and stopping of surfaces and levelling/ edging the disturbed places/ edges using necessary filling compound of cement based putty to obtain smooth regular/ even finish surface using sand paper and applying two coats of cement base paint on walls complete all as specified and as directed.
M&L for preparation of newly plastered or unplastered/undecorated surface of wall and applying three coat of white wash complete all as specified and as directed.
M&L for preparation of old decorated surface of walls by brooming down or steel wire brushing scrapping down smoke spot moulds moss and efflorescent salts and treating oily & greasy spots and filling of holes and cracks with with suitable material like cement or plaster of paris etc and thereafter applying one coat of white wash on wall complete all as specified and as directed.
M&L for preparation of newly plastered or unplastered/undecorated surface of ceiling and applying three coat of white wash complete all as specified and as directed.
M&L for preparation of old decorated surface of ceiling by brooming down or steel wire brushing scrapping down smoke spot moulds moss and efflorescent salts and treating oily & greasy spots and filling of holes and cracks with with suitable material like cement or plaster of paris etc and thereafter applying one coat of white wash on wall complete all as specified and as directed.
M&L for preparation of old painted surfaces of wood & wood based of any description over 10 cm in width or girth and applying one coat of synthetic enamel paint complete all as specified and as directed.
Removing bldgs demolished materials / debries exc. 1.50 km but n exc. 5 km and depositing where directed complete all as specified and as directed.
S&F in repair 110 mm dia PVC (SWR) pipes single socketed in any length with rubber rings joints fixed to walls/spout in roof slab complete all as specified and as directed.
S&F in repair 110 mm dia PVC (SWR) bends with rubber rings joints fixed as required complete all as specified and as directed.
Disconnecting existing tanks exc 500 & n exc 1000 litres, setting aside (or lowering if required) for repairs, cleaning, etc. and hoisting if required reconnecting and re-fixing in position (Cleaning repairing, etc. measured separately) complete all as specified and as directed.
S&F for Pressed steel frames 105X60mm (made out of 1.25mm thick MS Sheet) for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc complete all as specified and as directed.
M&L for cement concrete (1:3:6) type C1, (using 20 mm graded stone aggregate) as in filling of door frames of pressed steel and in bed blocks etc complete all as specified and as directed.
S&F factory made 35 mm thick flush shutters , solid core construction with block board core and plywood face pannel commercial type on both faces complete all as specified and as directed.
S&F 100 mm Butt hinges, Stainless steel and fixed complete all as specified and as directed.
S&F 200mm long aluminium anodised, barrel tower bolts of extruded section complete all as specified and as directed.
S&F 150 mm size extruded aluminium alloy handles fabricated type anodised and fixed complete all as specified and as directed.
S&F 250 mm long aluminium alloy anodised sliding door bolts with hasp stapple (bolt type) and fixing clips of sheet cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast sections or cast aluminium alloy complete all as specified and as directed.
M&L for preparation of new or previously untreated wooden surfaces of any description not otherwise described over 10 cm width or girth and applying two coats of synthetic enamel paint over one coat of pink primer complete all as specified and as directed.
M&L for prepration of new Steel surfaces of any description, not otherwise described, over 10cm width or girth & applying two coats of synthetic enamel paint complete all as specified and as directed.
Dismantling and taking down fluorescent tube light single/double of any wattage or size street light fittings for repair or replacement of burnt/worn out accessories or carrying to MES store for reuse or takeing in schedule of credit (Accessories or components to be provided free for replacement by department) complete all as specified and as directed.
Taking down carefully copper/aluminium point wiring light ,fan, socket or power complete, such as switches, ceiling roses, pendents, regulators, sockets etc.removing materials to store for keeping in safe costudy or for taking credit (credit for above items should be made as per conditioned separately) and making good disturbed surface of walls, floors etc. complete all as specified and as directed.
Taking down unserviceable / serviciable MCB DB's/AC's box to deposit in store for keeping in safe custody for reuse or takeing in schedule of credit of any size/rating complete all as specified and as directed.
Taking unserviceable sub main wiring of any type/size including wires, conduits/battens etc complete all as specified and as directed.
Taking down and S&F in replacement bracket made of GI-pipe light grade fitting 1.2 m in length and fixed on wall including necessary MS clamps nuts, bolts etc complete all as specified and as directed.
M&L for point wiring with two runs of FRLS PVC insulated unsheathed, 1100 V grade cable multi stranded copper conductor of size 1.5 sqmm drawn through in and including PVC conduit size of not less than 20mm concecled in wall / surface including provn of pressed steel terminal box of suitable size with 3mm thick plastic laminated sheet cover/modular white cover plate with frame as required module and modular metal flux box as required module at site for mounting switch, socket and regulator along with earth wire of PVC insulated, unseathed, 1100 V grade cable multi stranded copper conductor of size 1.5 sqmm complete all as specified and as directed for the following:-
One light point controlled by one switch one way.
One celling/exhaust fan point controlled by one switch one way.
One socket out let 5 Amps 5 pin on independent board.
One socket outlet 5 Amps 5 pin on same board with other switches.
All as per item No 75 here in before but with cable size 2.5 Sq mm for one 3/5 pin 15 Amps socket out let on independent board and multistrand insulated copper earth continuity conductor of size 2.5 sqmm complete all as specified and as directed.
S&F in replacement of switch piano, flush type, 5 Amps, single pole, one way complete all as specified and as directed.
S&F in replacement of switch piano, flush type, 15 amps, single pole, one way complete all as specified and as directed.
S&F in replacement of socket outlet 2in1, 3 pin 5 Amps flush type complete all as specified and as directed.
S&F in replacement of socket outlet 2in1, 6 pin 15/5 Amps flush type complete all as specified and as directed.
S&F in replacement of ceiling rose surface bakelite two to three terminals complete all as specified and as directed.
S&F in replacement of ceiling fan regulator stepped electronic type 300 watt rating complete all as specified and as directed.
S&F in replacement of modular switches 6 Amps single pole one way complete all as specified and as directed.
S&F in replacement of modular switches 16 A single pole one way complete all as specified and as directed.
S&F in replacement of modular socketes out let 6 Amps 5 pin complete all as specified and as directed.
S&F in replacement of modular socket out let 6/16 A 3 pin combined shuttered complete all as specified and as directed.
S&F in replaceent of MCB DB sheet metal enclosure single pole and neutral 240V with 200 Amp suitable size plate and common neutral link all enclosed in standard steel sheet flush mounting type factory fabricated Acrylic double door complete confirming to IP 43 without MCB and with enclosure blank plates for unused way suitable for 12 way complete all as specified and as directed.
All as per item No 97 above but 8 way, complete all as specified and as directed.
All as per item No 97 above but 4 way, complete all as specified and as directed.
Taking down and supply, laying, jointing and testing XLPE LT insulated, PVC outer sheathed, galvanised steel strips armoured, heavy duty power cable with aluminium conductor suitable for rated voltage of 1100 Volts grade earthed system and conforming to IS : 7098 of 1995 and of size 3.5core x 50Sqmm and laid in trenches/ducts/pipe or on poles complete all as specified and as directed.
M&L for sub main wiring with 2 Run of 4 Sqmm cable and one run of 4 sqmm PVC insulated, unsheathed FR cable of multistranded copper conductors 1100 volt grade IS- 694 marked drawn through and including non metalic PVC conduit pipe medium grade ISI marked (not less than 20 mm dia) along with fittings and accessories concealed on wall and surface on ceiling complete all as specified and as directed.
All as per item No 101 but 2x2.5 sqmm and 1x2.5 sqmm complete all as specified and as directed.
All as per item No 101 but 2x6 sqmm and 1x 6 sqmm complete all as specified and as directed.
All as per item No 101 but 2x10 sqmm and 1x 10 sqmm complete all as specified and as directed.
S&F in replacement of sheet metal enclosure with socket plug top and MCB single pole and neutral with two pin and earth plug with one SP MCB 20 Amp 240 volt complete all as specified and as directed.
S&F in replaceent of MCB DB sheet metal enclosure Vertical Triple pole and neutral 415V with 200 Amp suitable size plate and common neutral link all enclosed in standard steel sheet flush mounting type factory fabricated Acrylic double door complete confirming to IP 43 without MCB and with enclosure blank plates for unused way suitable for 12 way complete all as specified and as directed.
S&F MCB, single pole & neutral, 240 Volts ( 40-63) Amps,10KA, 'B' series complete all as specified and as directed.
S&F MCB, single pole, 240 Volts (05 to 32) Amps,10KA, 'B' series complete all as specified and as directed.
Supply and fixing 415V 10KA 'B' curve miniature circuit breaker (MCB) of Triple pole and Neutral 40 to 100 Amps and current carrying capacity in the DB complete with connection testing and commissioning complete all as specified and as directed.
S&F MCCB, Three pole & neutral, 415 Volts 125 Amps, 25KA complete all as specified and as directed.
S&F LED flood light 100 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistantcomplete with driver and lamp complete all as specified and as directed.
S&F LED street light fitting 70 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and as directed.
S&F LED lights fitting 1x 22W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and as directed.
S&F LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and as directed.
S&F LED luminaire 600 mm x 600 mm, 35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete all as specified and as directed.
S&F exhaust fan, steel body AC single Phase. 230V of size 450mm sweep with, blades, and frame and louvers complete all as specified and as directed.
M&L for cutting opening through brick wall 230mm thick built in cement morter suitable for exhaust fan 450mm sweep including making good dismantled surface/position in cement morter 1:3 or cement concrete 1:2:4 type B-1 as required complete all as specified and as directed.
S&F exhaust fan made of sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, Copper winding of sweep 300 mm sweep complete all as specified and as directed.
Excavation in trenches not exceeding 1.5 m wide and and not exceeding 1.5 m depth in loose/soft soil and getting out soil all as specified and as directed.
Returning, filling in, with excavated soil including spreading, levelling, watering and well ramming in layers not exceeding 25 cm complete all as specified and as directed.
Removal of surplus soil to distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point complete as specified and as directed.
M&L for boring/auguring suitable hole & insertion of pipe not less than 300 mm below existing PCC/road/hard standing including GI pipe 40mm complete all as specified and as directed.
M&L for sand in trenches including spreading for cushioning of LT UG cable complete all as specified and as dirceted.
Supply and laying burnt clay fly ash building bricks for protection of LT cable cover complete all as specified and as directed.
Taking down the existing cables from trenches of size 3.5core 50 Sqmm 1100 Volt grade complete all as specified and as directed.
M & L for Earthing complete with GI earth plate electrode 60cmx60cmx6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below normal ground level) with top edge of the plate not less than 1.5 metre below normal ground level, connected to and including using GI wire 4mm dia as earthing lead by means of bolts, nuts, check nuts and washers of galvanized iron or steel, earth plate surrounded by packed layer of char coal dust and common salt, 15cm thick all around bottom and top and watering pipe 20mm bore of GI medium grade with funnel, wire mesh and 40 mm dia GI protection pipe light grade all as shown in electrical plate No 3 of SSR Part-I and connected to earthing test point, main switch board and testing on completion including excavation, earth work concrete pit with 80mm thick RCC cover in RCC 1:2:4 type B-1 duly reinforced with MS bars 8mm dia @ 150C/C both ways and pit chamber in PCC 1:2:4 type B-1 with 2 Nos suitable lifting handles of 12mm MS bar complete all as specified and as directed.
S&F Steel windows or ventilators, fixed type, with glazing bars complete all as specified and as directed.
M&L for plain cement concrete 1:4:8 type D-2 (using 40mm graded stone aggregate) as in foundation, filling & mass concrete, sub base complete all as specified and as directed.
M&L for Machine cut kota stone slab flooring 20-25mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab over and including 20mm thick screed bed in CM 1:4 and polishing complete all as specified and as directed.
KISHAN SINGH AND CO
akhil enterprises
M/S Rohit Enterprises
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .