Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹4.6 CrAccepted-AOC GROUND FLOOR C 151 OKHLA INDUSTRIAL AREA PHASE 1 SOUTH EAST DELHI SOUTH WEST DELHI DELHI 110070 | NEW DELHI | DELHI | 110070 | ₹4.6 Cr | L1 | Accepted-AOC L1 |
| 2 | L2₹6.8 CrRejected-AOC A 7 TALKATORA INDUSTRIAL ESTATE TALKATORA ROAD LUCKNOW UTTAR PRADESH 226011 UDYAM UP 50 0008626 | LUCKNOW | UTTAR PRADESH | 226011 | ₹6.8 Cr | L2 | Rejected-AOC L2 |
| 3 | L3₹9.6 CrRejected-AOC B 46 INDUSTRIAL AREA SECTOR 59 NOIDA UP 201301 | GAUTAM BUDDHA NAGAR | UTTAR PRADESH | 201301 | ₹9.6 Cr | L3 | Rejected-AOC L3 |
| 4 | Not Admitted-Fee/PreQual/Technical | - | - | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
Tender Value
₹5.1 Cr
EMD Value
₹5.1 L
Closing Date
22 Feb 2021, 1:00 pmClosed
Executive Engineer
Executive Engineer NHP Irrigation Department Sector 5 3rd floor NHP Data Center
Supply, Install., Testing and Comm. of 300 Digital Water Level Recorder (DWLRs)(Non-Vented pressure type / Acoustic type) with Telemetry, including fencing and establishment of Data Acquisition system along with its maintenance for Real Time GW Level
2021_WBIRR_157197_1
HRY/NHP/PIEZOMETERS/GW/02
Open Tender
Miscellaneous Goods
1825 days
Panchkula
Please refer tender Documents
3 documents required · 3 mandatory
₹0
₹5.1 L
Panchkula (Online)
31 Aug 2021
21 Jan 2021
22 Feb 2021
21 Jan 2021
22 Feb 2021
17 Feb 2021
5 Feb 2021
Amount
Digital Water Level Recorders (DWLRs) –Non Vented Pressure Type / Acoustic Type,with telemetry system
Supply of Digital Water Level Recorders (DWLRs) with non –vented hydrostatic pressure type sensor with barometric pressure correction for individual station, with measurement range (as per attached list) of up to 30 meter along with sensor cable, as per list of installation sites specified in Table-I, and Conductivity sensor along with sensor cable as specified in Table-I including junction box and necessary accessories with battery operated data logger and GSM & GPRS telemetry system, complete as per the technical specifications. OR Supply of Digital Water Level Recorder, with Acoustic type water level sensor with measurement range of up to 150 meter, as per list of installation specified in Table- I, and Conductivity sensor along with sensor cable as specified in Table-I along with interface cable including junction box, with all necessary accessories with battery operated data logger and GSM & GPRS telemetry system, complete as per the technical specifications. (Bidder should clearly specify the type of offered sensor for DWLR system in the technical responsiveness form) (Bidder has to supply only one type of either sensor)
Supply of Digital Water Level Recorders (DWLRs) with non –vented hydrostatic pressure type sensor with barometric pressure correction for individual station, with measurement range (as per attached list) of up to 50 meter along with sensor cable, as per list of installation sites as specified in Table-I, and Conductivity sensor along with sensor cable as per list of installation sites specified in Table-I including junction box and necessary accessories with battery operated data logger and GSM & GPRS telemetry system, complete as per the technical specifications. OR Supply of Digital Water Level Recorder, with Acoustic type water level sensor with measurement range of up to 150 meter, as per list of installation specified in Table- I, and Conductivity sensor along with sensor cable as per list of installation specified in Table-I along with interface cable including junction box, with all necessary accessories with battery operated data logger and GSM & GPRS telemetry system, complete as per the technical specifications. (Bidder should clearly specify the type of offered sensor for DWLR system in the technical responsiveness form) (Bidder has to supply only one type of either sensor)
Establishment of Data Centre -all equipment’s and services as per Technical specifications
Server along with server rack, Monitor, and 3 KVA online UPS as per technical specification
IT Hardware which includes required Static IP, Router, Switches, firewall system as per technical specifications
High speed synchronous internet connection (min. 8 mbps upload and download) for five years
Digital Water Level Recorders (DWLRs) –Non Vented Pressure Type / Acoustic Type, with telemetry system
Installation, Testing and Commissioning of Digital Water Level Recorders (DWLRs) with non –vented hydrostatic pressure type sensor with barometric pressure correction for individual station with measurement range (as per attached list) of up to 30 meter along with sensor cable, as per list of installation sites specified in Table-I, and Conductivity sensor along with sensor cable as per list of installation sites specified in Table-I, including junction box and 5 meter signal cable and necessary accessories with battery operated data logger and GSM & GPRS telemetry system, complete as per the technical specifications. OR Installation, Testing and Commissioning Digital Water Level Recorder, with Acoustic type water level sensor with measurement range of up to 150 meter,as per list of installation specified in Table- I, and Conductivity sensor along with sensor cable as per list of installation specified in Table- I along with interface cable including junction box, with all necessary accessories with battery operated data logger and GSM & GPRS telemetry system, complete as per the technical specifications. (Bidder should clearly specify the type of offered sensor for DWLR system in the technical responsiveness form) (Bidder has to supply only one type of either sensor)
Installation, Testing and Commissioning of Digital Water Level Recorders (DWLRs) with non –vented hydrostatic pressure type sensor with barometric pressure correction for individual station with measurement range (as per attached list) of up to 50 meter along with sensor cable, as per list of installation sites specified in Table-I, and Conductivity sensor along with sensor cable as per list of installation sites specified in Table-I, including junction box and 5 meter signal cable and necessary accessories with battery operated data logger and GSM & GPRS telemetry system, complete as per the technical specifications. OR Installation, Testing and Commissioning Digital Water Level Recorder, with Acoustic type water level sensor with measurement range of up to 150 meter,as per list of installation specified in Table- I, and Conductivity sensor along with sensor cable as per list of installation specified in Table- I along with interface cable including junction box, with all necessary accessories with battery operated data logger and GSM & GPRS telemetry system, complete as per the technical specifications. (Bidder should clearly specify the type of offered sensor for DWLR system in the technical responsiveness form) (Bidder has to supply only one type of either sensor)
Construction of Fencing with wire mesh (76 mm x 76 mm x 12 mm gauge) around the piezometer site as per drawing attached including Fabrication and supply, fixing and painting of Fencing angle iron, sign board of frame size 0.75 m x 0.6 m x 1.2 mm thick with cross strips and provisionto fix on wire mesh frame. Overall size of fencing will be 1 m x 1 m x 1.7 m above ground as per Drawing and Design including all labour and material etc. required as per technicalspecifications.
Cleaning of Piezometer using Air Compressor Development of tube well in accordance with IS : 2800 (part I) and IS: 11189, with required capacity air compressor, running the compressor for required time till well is fully developed (for 5 hours) including all accessories and labour charges (For All 300 Piezometer Locations as specified in this tender)
Establishment of Data Centre -all equipment’s and services as per Technical specifications
Installation, Testing and Commissioning of Server along with server rack, Monitor, and 3 KVA online UPS as per technical specification
Installation, Testing and Commissioning of IT Hardware which includes required Static IP, Router, Switches, firewall system as per technical specifications
Installation, Testing and Commissioning of High speed synchronous internet connection (min. 8 mbps upload and download) for five years
Integration of GSM &GPRS data with the existing State Hydrology Data Center and Cloud Server and e-SWIS/NHP Server with all ancillary equipment, as per technical specifications.
Five Years Operation & Maintenance after commissioning and Comprehensive Warranty for DWLRs with Telemetry system along with accessories, installed at designated locations as specified in schedule, after final acceptance and up gradation of all software associated with DWLR systems. This includes replacement of batteries as &when required at bidders cost. The cost of communication using GSM & GPRS sim cards and other related charges.
Training of the purchaser's personnel at the supplier’s plant and/or/onsite in assembly, startup, operation, maintenance and/or repair of DWLR with telemetry and relevant software and supplied goods. Course topics will include sensor calibration, data logger configuration, data downloading, data retrieval, collection, Trouble shooting, processing maintenance requirements and procedure for equipment configuration, installation, site testing and commissioning including training kit containing course material in soft and hard copies as per technical specification.
ENCARDIO-RITE ELECTRONICS PVT LTD
Aaxis Nano Technologies Pvt. Ltd.
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid