Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹43.5 LAccepted-AOC | L1 | Accepted-AOC Lowest | |
| 2 | L2₹44.5 L+₹25,865.68 (0.59%)Rejected-Finance 704 SILVER DEAL DAFFODIL WING 1 B T KAWADE ROAD PUNE 411 001 | PUNE | PUNE | MAHARASHTRA | 411001 | L2 | Rejected-Finance Not Lowest | |
| 3 | L3₹47.8 L+₹3.6 L (8.11%)Rejected-Finance | L3 | Rejected-Finance Not Lowest | |
| 4 | L4₹50.7 L+₹6.5 L (14.6%)Rejected-Finance 1 NEAR AKBARIYA MASJID WIMBERLYGUNJ SOUTH ANDAMAN ANDAMAN NICOBAR 744206 | SOUTH ANDAMANS | ANDAMAN AND NICOBAR ISLANDS | 744206 | L4 | Rejected-Finance Not Lowest | |
| 5 | L5₹53.9 L+₹9.7 L (21.9%)Rejected-Finance S NO 50 8 MAMTA SOCIETY VADGAONSHERI BEHIND AYYAPPA TEMPLE PUNE 411014 | PUNE | PUNE | MAHARASHTRA | 411014 | L5 | Rejected-Finance Not Lowest |
Tender Value
₹58 L
EMD Value
₹1.1 L
Closing Date
21 Sept 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE PUNE
HEADQUARTERS COMMANDER WORKS ENGINEERS GEN CARIAPPA MARG, PUNE-411 001
84785REPAIRS, MAINTENANCE / REPLACEMENT OF HT 11 KV RING MAIN / DETERIORATED CABLES AT HQ SC , HQ CESE, SCOM, 16 QG, SFC, ZRO, NEW RSI, GURUDWARA ROAD, KOHIMA LINE,KG LINE, TELEPHONE EXCHANGE SUB STAION ETC IN THE AREA OF AGE E/M NORTH UNDER GE (NOR
2022_MES_547259_1
84785REPAIRMAINTOFHTATGENPUNE
Open Tender
Electrical and Maintenance Works
Item Rate
273 days
GE North Pune
AS PER TENDER
9 documents required · 9 mandatory
₹1,000
GE North Pune
₹1.1 L
Yes
23 Nov 2022
24 Aug 2022
23 Sept 2022
24 Aug 2022
21 Sept 2022
7 Sept 2022
Amount
Excavation in trenches not exc 1.5 m wide and not exc 1.5 metre depth for laying of UG cable / pole foundation etc getting out including forming bottom surface to required level and gradient in soft /loose soil complete all as specified and as directed.
Returning, Filling in including spreading,leveling, watering and well ramming in layers not exc. 25 cm thick in soils, complete all as specified and as directed.
Removing surplus soil to a distance not exc 50.00 m away and depositing where directed at a level not exc 1.50 m above the starting point, complete all as specified and as directed.
Supply and laying 120 mm outer dia, double walled corrugated (DWC) HDPE duct pipe conforming to IS- 14930 Pt-II with antirodent and non flame propogating properties of approved colour complete with fittings for cable protection complete all as specified and as directed.
M&L for Clean dry river sand in trenches / ducts for cushioning to cable, 8 cm in depth before laying the cable and 15 cm in depth after laying the cable complete all as specified.
M&L for cement concrete in foundation, filling and mass concrete type B1 1:2:4 (20 mm graded aggregate) for LT Panel board foundation/Fencing Fountation/Yard Boundary and making good the road cutting areas complete all as specified and directed.
M&L for cement concrete 1:4:8 (40 mm graded aggregate) as Lean Concrete in Foundation of Poles etc, including Formwork (as if required), complete all as specified and as directed.
M&L for cement concrete 1:3:6 (20 mm graded aggregate) as in coping of pole etc including form work & finishing the surfaces even & smooth with out using extra cement complete all as specified
Preparation of old surfaces of ceiling of any description and applying one coat of white wash (lime) complete all as specified and as directed.
M&L for complete removal of existing finish/treatment on walls, prepararing surface and make surface free from loose particles, oil stains etc and applying two coats of cement based paint all as directed.
M&L for complete removal of existing finish/treatment on walls, preparing surface and make surface free from loose particles oil stains etc and applying two coats of dry apex ultima all as specified and as directed.
M&L for complete removal of existing finish/treatment of steel surface of any description not otherwise described over 10 cm width or girth and applying, two coats of synthetic enamel paint over a coat of red oxide complete all as specified.
M&L for complete removal of existing finish/treatment of old wood and wood based materials of any description not otherwise described over 10cm width or girth and applying, two coats of synthetic enamel paint over coat of pink primer complete all as specified.
S&F in repair aluminium lugs duly crimped at end termination of Transformer/ LT distribution panel connected with various sizes of LT cable including all allied works such as disconnecting cable from supply site, removing from gland, making equal length of each core of cable and refixing the same with new metal gland all as specified and as directed.
a) Upto 3.5 core x 35 Sqmm.
b) 3.5 core x 50 Sqmm
c) 3.5 core x 70 Sqmm
d) 3.5 core x 95 Sqmm
e) 3.5 core x 120 Sqmm
f) 3.5 core x 185 Sqmm
g) 3.5 core x 240 Sqmm
h) 3.5 core x 400 Sqmm
Note:-(i) Each job includes the 04 Nos aluminium lugs at one end termination, insulating material and 01 No metal gland etc.
M&L for Checking the fault in the LT distribution cable of any size and length at any location with fault detector machine and fixing only straight through cable joint kits (LT) and LT UG cable as required length after determining the fault location including earth work at any strata as required depth and width and testing complete all as specified and as directed by Engr- in- charge. Note:- i) Fault detector machine & other equipment shall be arranged by the contractor within 1 hour of complaint received. ii) Cable jointing kit and LT UG cables shall be measured and paid seperatly as supply only under relevant items.
Supply only cable jointing kit 1100 volt (1.1KV) grade cable for straight through heat Shinkable type, tubuler sleeve version joint kit complete with jointing material and accessories suitable for XLPE/ PVC armoured aluminium conductor cable of the following sizes complete all as specified.
a) From 25 sq.mm to 50 sq.mm of 3.5 core.
b) From 3.5 core x 70 Sq mm and upto 150 Sqmm.
c) From 3.5 core x 185 Sqmm and upto 400 Sqmm.
Checking the fault in HT cable, of any size and length at any location, 11000 Volts AC system with fault detector machine and inserting straight through cable joints kits (HT) after determining the fault location including earth work at any strata as required depth and width and testing complete.Note :- (i) fault detector machine & other equipment shall be arranged by the contractor within 1 hour of complaint received. (ii) HT Cable jointing kit cables shall be measured and paid seperatly as supply only under relevant items.
Supply only cable jointing kit 11 KV (Earthed ) grade cable for straight through heat shrinkable type joint complete with jointing material and accessories suitable for XLPE armoured aluminium conductor cable of following sizes:-
(a) 3 core x 95 Sqmm
(b) 3 core x 120 Sqmm to 185 Sqmm.
M&L for cable end jointing kit 11 KV (Earthed ) grade cable for indoor termination heat shrinkable type joint complete with jointing material and accessories suitable for XLPE armoured aluminium conductor cable of following sizes:-
(a) 3 core x 95 Sqmm
(b) 3 core x 120 Sqmm to 185 Sqmm.
M&L for cable end jointing kit 11 KV (Earthed ) grade cable for outdoor termination heat shrinkable type joint complete with jointing material and accessories suitable for HT XLPE armoured aluminium conductor cable of following sizes:-
(a) 3 core x 95 Sqmm.
(b) 3 core x 120 Sqmm to 185 Sqmm.
Supply and laying testing and commissioning HT XLPE cable , insulated, screended, PVC bedded, galvanised steel strip or wire armoured, electic power cable (heavy duty) with staranded aluminium conductor, conforming to IS : 7098 (Part II), 11 KV "E" grade, cross sectional area laid in pipe/ducts/ trenches/ under floor/ under road all as specified of following sizes:- Note :- Excavation, earth work, cable ptotection pipe measured and paid sepretaly .
(a) 3 core x 95 Sqmm
(b) 3 core x 120 Sqm.
S&F for switch air break gang operated HT 11 KV Volt grade out door type, triple pole of capacity 200 amps rating mounted on Polymer based on 15 insulator complete set with expulsion fuse set single pole drop out type including Expulsion fuse carriers and fuse element Upto 25 Amp and fitted on steel frame vertical mechanically operated mechanism from ground level consisting of operating rod of 25 mm bore Heavy grade GI pipe of suitable length worked from ground level and with locking arrangements incl pad locks with key flat iron clamp 50 mm x 6 mm including taking down old unseviceable one complete all as specified and as directed.
S&F in replacement of unserviceable Automatic transfer switch 400 A ,4 pole ,36 KA 440 volt 50/60 Hz inbuilt in sheet metal enclosure with adjustable thermal & fixed magnetic setting relay with bus bar spreader links for connecting both incoming and outgoing cables with suitable connections with suitable size of glands etc complete including testing & commissioning all as specified and as directed by the Engineer-in-Charge.
S&F for Insulator Pin / post type polymer based including one galvanishing MS spindle, nuts & washers for 11000 volt grade and fixing to the structure and binding of conductor including removal of unserviceable one from the HT 2 pole/ 4 pole structure complete all as specified and directed.
S&F for Alkathine PVC pipe for bus/ jumper connection as insulating material at 4 pole/ 2 pole structere in the area complete all as specified and as directed.
S&F for HT Aluminium ferrules / lugs of suitable size with chromium plated nut bolts for connection of GOD / DO / cable end jumpers including removal of unserviceable one complete all as specified and as directed.
S&F for Aluminium tubing heavy duty of size 32 mm outer dia 12 mm thick with necessary clamps, bolts nuts and washers of suitable size, mounted on polymer based 11 KV insulators connection with jumpers including removal of unserviceable one complete all as specified and directed.
Refixing only for Cross-arms, Bracings, Supports, Clamps and Back Plates (serviceable materials i.e. Structural Steel Sections obtained from Item No. here-in-before) including Nuts, Bolts, Washer, welding, bending cold or hot, drilling holes for Bolts, in any shape or size as indicated/ directed and inclusive of one coat of Aluminium Primer one Under Coat and One Finishing Coat of Aluminium Paint, complete all as specified and as directed.
M&L for Cross arms, bracings, supports, clamps and back plate fabricated from structural steel sections including nuts, bolts, washers, welding, bending hot or cold, drilling holes for bolts in any shape or size as indicated or directed and inclusive of one primer coat one under coat and one finishing coat of aluminium silver paint includind taking down rusted unserviceable cross arm complete all as specified.
S&F Lightening arrestor non linear resistor type conforming to IS 3070 (part-3) 1993 complete, line discharge class-3, nominal discharge current 10 KA (peak) , 12 KV rated system, voltage peak value high current impluse of 4/10 micro Sec. wave shape 100 KA (peak) assembly suitable for 11 KV, long duration descharge class-II with insulation level 28/75 KV and mounted on hot dip galvanized steel structure including all clamps, nuts, bolts and washers and connecting to earth with 4 mm dia GI wire including removal of extg unsv one complete all as specified and as directed.
Taking down the existing servicable incoming and out going HT/LT UG cable of any type/ description with all connections from panel/transformer/GOD etc near 2/4/6/8 pole structure and relocate and reconnections with necessary excavation of soils and replacement of cable lugs, bolts and nuts etc complete all as specifified and as directed.
S&F chain link MS galvanised fencing of GI line wires, 65 x 65 mm mesh, 05 mm size and type to any type of standards, rails, straining bolts, etc. including provission of binding wire including painted with synthetic enamel aluminium paint all as specified and as directed.
M&L for stone aggregate of sze 35 to 40 mm spreading over sand layer in the sub station areas including proper levelling all as directed and shown at site all as directed by Engr-in-Charge.
M&L for stone aggregate of size 20 to 25 mm spreading over sand layer in the sub stations areas including proper levelling all as directed by Engr-in-Charge.
M&L for Angle Iron, fountation poles, cross arms, brazings, supports,, clamps and back plate fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of paint. Note: The PCC for fountation of Fencing Pole shall be measured and paid separately.
Supply and laying in repairs synthetic/silicon Insulating sleeves having stripping, increased flexibility, tear & High Temp resistant and dielectric strength of suitable thickness straight/Curved suitable for HT 11 KV ACSR Conductor/ Bus Bar Lines fixed in structures , free from any insertions leading to detoriation of insulating properties and confirming to IS-15652:2006 complete all as specified and as directed. Note : The upper surface should have colour coding of Red / Yellow / Blue as Phase indication.
M&L for stringing and fixing in position of ACSR conductor in OH line 3 phase 4 wire/ 1 phase 2 wire of any size as per site requirement including provision of aluminum binding wire complete incl removing of old unsv ACSR conductor complete all as specified and as directed.
Labour only for painting and repair to HT 11 KV, 4/6/8 pole structure of 11 meter height steel poles including replacement of all perished ACSR conductor (ferret) of Horizontal bus bar and down conductors for GOD system on structure, jumpering and binding with aluminium conductor to the post insulators/ pin insulators and providing PVC sleeves to the down conductor with colour code R, Y & B, replacing all rusted nuts & bolts on the above pole structure all as directed.
All as per item No 38 here- in- above but for two pole strtucture complete all as directed.
Note for item No 38 & 39 :- Spares required shall be measured and paid seperately.
M&L for Danger notice plate of 1.6mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with M.S. clamps, bolts and nuts of approvrd size, for LT, 20 x 15 cm size all as specified and as directed
M&L for Danger notice plate of 1.6 mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with M.S. clamps, bolts and nuts of approvrd size, for HT, 20 x 20 cm size all as specified and as directed.
Taking out the unsv & perished panel board doors/ body from the panel board replace with same size made out of CRCA sheet of 3.00 mm thick duly fabricated welded the door hinges and having proper locking arrangement to the existing LT panel doors by means of replacing the door hinges, nuts bolts & washers etc and making doors operatablein including two coats of synthetic enamel paint over a coat of red oxide primer with spray painting match with existing colour complete all as specified and as directed.
Note :- (i) T&P as required shall be arranged by the contractor such as welding machine etc.
M&L for painting of feeder pillar/ out door LT panels/DG sets at various places including scraping rusts, cleaning of duct, old paint applying of two coat of synthetic enamel paint over the surface of panel board with spray painting complete all as directed.
S&F for MCCB, TPN, 415 Volts, Adjustable type, 400 Amps with breaking capacity 36 KA, Ics = 100% Icu with suitable fixing arrangements in the panel with refixing the existing cable, including removing of old unsv itemscomplete all as specified and directed.
S&F for MCCB, TPN, 415 Volts, Adjustable type, 250 Amps with breaking capacity 36 KA, Ics = 100% Icu with suitable fixing arrangements in the panel with refixing the existing cable, including removing of old unsv itemscomplete all as specified and directed. Make-L&T/schneider/ABB
S&F for MCCB, TPN, 415 Volts, Adjustable type, 200 Amps with breaking capacity 25 KA,Ics = 100% Icu with suitable fixing arrangements in the panel with refixing the existing cable, including removing of old unsv itemscomplete all as specified and directed.
S&F for MCCB, TPN, 415 Volts, Adjustable type, 160 Amps with breaking capacity 25 KA, Ics = 100% Icu with suitable fixing arrangements in the panel with refixing the existing cable, including removing of old unsv itemscomplete all as specified and directed.
S&F for MCCB, TPN, 415 Volts, Adjustable type, 125 Amps with breaking capacity 25 KA, Ics = 100% Icu with suitable fixing arrangements in the panel with refixing the existing cable, including removing of old unsv itemscomplete all as specified and directed.
S&F for MCCB, TPN, 415 Volts, fixed type, 100 Amps with breaking capacity 18 KA with suitable fixing arrangements in the panel with refixing the existing cable, including removing of old unsv itemscomplete all as specified and as directed.
S&F for MCCB, TPN, 415 Volts, fixed type, 63 Amps with breaking capacity 18 KA with suitable fixing arrangements in the panel with refixing the existing cable, including removing of old unsv itemscomplete all as specified and directed.
Treaming of tree branches around over head electric lines and cleaning 3 Mtrs from the line, removing cut materials ( tree branches) from site and stacing properly where directed. Grith of branch ( where cutting took place) not exceeding 50 mm complete all as specified.
All as per item No 53 here- in- above but grith exceeding 50 mm but not exceeding 100 mm complete all as specified.
All as per item No 53 here- in- above but in above but grith exceeding 100 mm but not exceeding 150 mm complete all as specified.
Cutting unaxious green growth and wild grass by manual labour or by machine at Electrical Installation Premises, around Pole, along the boundary Fencing and Clearing off the shrubs, vegetation grass, bushes, plants and saplings grown below HT lines and all sub-stations in the area and clearing the rubbish material rubbish from the Site of Work and deposting where directed not exc. 100 Metre from the starting Point, complete all as specified and as directed by Engr-in-charge. Note :- The Item shall be operated maximum 3 times in the entire period of the Contract and the measurement will be taken every time independently for Payment.
M&L for 80 mm bore pipe galvanised steel pipe light grade laid in trenches etc complete as in protection of UG all as specified and as directed.
S&F in replacement Automatic power factor controller 8 stage 415 volts AC 50 Hz power supply complete all as specified and directed. Make: L&T equivalent in GE/NEPTUNE
S&F in replacement (LTXL) type MD ultra heavy duty box / cylindrical type LT 415/440 volts three phase 50 Hz Power Factor correction capacitors with Operating losses 0.35 W/kVAr, Peak Inrush current 500 x In, Max. Ambient temp 70 degree C and Over current withstand capability 3 x In of capacity 25 KVAR complete as per site requirement all as specified and directed.
All as per item No 60 here- in- above but 15 KVAR capacity.
All as per item No 60 here- in- above but 10 KVAR capacity.
S&F in repairs / replacement capacitor type MO C10 Duty contactor 3 Pole, 415 V, capacity 10 kVAr, 2NO + 2NC having coil voltage 240 Volts all as directed by Engineer-in-Charge. Make : L&T Model No. CS96156 its equivalent
S&F in repairs / replacement capacitor type MO C15 Duty contactor 3 Pole, 415 V, capaccity of 15 kVAr, 2NO + 2NC having coil voltage 240 Volts all as directed by Engineer-in-Charge. Make : L&T Model No. CS90019 or its equivalent
S&F in repairs/replacement capacitor type MO C25 delta Duty contactor 3 Pole, 415 V, capacity 25 kVAr, 2NO + 2NC having coil voltage 240 Volts all as directed by Engineer-in-Charge. Make : L&T Model No. CS96322 or its equivalent
S&F MCX 43, 4P Power Contactor 400 Amps, 415 Volt, 50 Hz AC suitable for panel including removal of existing unserviceable one compete all as specified and as directed. Make: Simens/ L&T/ Schneider.
S&F MNX 225, 3P Power Contactor 300 Amps, 415 Volt, 50 Hz AC suitable for panel including removal of existing unserviceable one compete all as specified and as directed. Make: Simens / L&T / Schneider.
S&F MNX 110, 3P Power Contactor 160 Amps, 415 Volt, 50 Hz AC suitable for panel including removal of existing unserviceable one compete all as specified and as directed. Make: Simens / L&T / Schneider.
S&F MNX 50 3P Power Contactor 45 Amps, 415 Volt, 50 Hz AC suitable for panel including removal of existing unserviceable one compete all as specified and as directed. Make: Simens/ L&T/ Schneider.
S&F in repairs Machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 60 mm thickness, M-35 Grade with grey cement and no pigments all as directed and specified by Engineer-in-charge.
Taking up and replacing carefully paver blocks/ PCC blocks of any size and shape required to be displaced for excavation purpose of the cable laying including the sand /red bajri /shingles beneath the same and consolidating the same after refiling of the earth.
M&L for Road cutting works / repairs of any depth incld scartifying or picking gravelled macadam or bituminius macadam surfaces in area not exc 400 Sqm exc 50 mm and not exc 100 mm deep removing the same to a distance 50 m and staking where directed and sweeping free from dust and mud or water scoring sunken surfaces in roads paths etc cutting around edges to at least 25 mm in depth making good by filling in screened & graded road metal watering and well ramming (incld supply of road metal) applying evently priming / tack coat primer using paving bitumen @ 05 Kg per 10 Sqm and providing bituminious permix asphaltic semi dense concrete (design mix) 30 mm thick (consolidated ) thickness with 5.5% binder content by weight of toal mix laid with mechanical paver rolled and compacted to required camber and gradient with 8 to 12 ton power roller complete all s specified and as directed .
M/S - KRUPA ELECTRICALS
GANESH ELECTRICALS AND AIR CONDITIONERS
SBS Enterprises
PARAMOUNT ELECTRICALS
Rama Electricals
CHAITANYA WINDWELL
Mahindra Electric Stores
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .