Loading…
Loading…
Eligibility, documents, scope, Go/No-Go checksEligibility, required documents, scope of work and Go/No-Go checks for this tender, in one click.
Tender Value
₹25.7 L
EMD Value
₹51,400
Closing Date
21 Oct 2026, 3:00 pm
Eligibility, documents, scope, Go/No-Go checksEligibility, required documents, scope of work and Go/No-Go checks for this tender, in one click.
No
No
Single Packet System
Normal Tender
No
Not Applicable
Lowest to Highest
63 days
Expenditure
Capital (Works)
WORKS
11 conditions · 8 needing a document upload
Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions.
1) Tenderer should attach self attested copy of PAN CARD and photo identification in support of their Identity. 2) The documents attached to the tender document should be clear and legible for evaluation of tenders. Proper care to be taken in this regard
A copy of document to be uploaded containing the following details: Name of the tenderer/ contractor, Validity of DSC, Complete address with pincode, Contact No.
Scanned copy of PAN card has to be enclosed
Scanned copy of TIN card has to be enclosed
A copy of NEFT form duly filled in the details as necessary along with a cancelled Cheque to be uploaded. (The tenderer/ contractor not having NEFT form may down load the empty NEFT form available in documents site)
Information/ certificates required as per Tender document for partnership deed, Article of association, MOU, JV AGREEMENT, Proprietary firm etc.
Self Attested copy of Experience Certificate of Previous Work Done -The bidder should submit documents related to completed/on-going similar service contracts during the last three previous financial years and the current financial year along with the details of payments received and percentage penalties imposed therein, to classify the completed/ on-going similar service contracts.
For materials of purchase value Rs.5 lakhs and above, inspection shall be done by third party i.e. M/s. RITES and all expenditure in connection with the inspection shall be borne by thetenderer/Contractor (5) For ISI marked products, if the order is placed on ISI certified manufacturers, the materials can be accepted on firm's WTC
Improvement of platforms at Arakkonam(AJJ) station in ADEN/AJJ sub division - Electrical arrangements thereof.
ME-29-II-1108-2026~SR
ME-29-II-1108-2026
Open
Works - General
90 Days
Chennai, Tamil Nadu
₹0
₹51,400
29 Sept 2026
29 Sept 2026
7 Oct 2026
95 items across 1 schedule
| # | Description | Unit | Qty | Rate | Amount |
|---|---|---|---|---|---|
| — | — | — | 25,69,863 | ||
| — | — | — | Above/ 48900.00 Below/P | ||
| Demolishing plain cement concrete in platform or elsewhere, disposal of material atleast 6m away from track centre within railway land by saw cutting/breaker as per site conditions to avoid any damage to nearby site complete in a manner as directed by the Section Engineer in charge at site. | — | 100.00 | — | — | |
| — | — | — | Above/ 511500.00 Below/P | ||
| Supply and provision of mass concrete for platforms or elsewhere with 1:2:4 ratio using 20mm graded blue metal complete in a manner as directed by the Section Engineer in charge at site. NOTE: i)Cement shall be Ordinary Portland Cement, 43 grade, conforming to IS: 456 or latest. ii)Proper compaction of cement concrete shall be ensured as per standard industrial practices. iii)The finished level should match with surface level properly | — | 100.00 | — | — | |
| — | — | — | Above/ 55500.00 Below/P | ||
| Laying/leading of 4 core 95 sq.mm LTUG Aluminium cable in the excavated trench, threading through pipe, clamping on walls and terminating in as many ends using suitable single compression cable glands, lugs , sockets and other items required complete as per site conditions in a manner complete as directed by Section Engineer in charge at site. Note:- 4Cx95 sq.mm LTUG Aluminium Cable alone will be supplied departmentally. | — | 1500.00 | — | — | |
| — | — | — | Above/ 30000.00 Below/P | ||
| Laying/leading of 4 core 50 sq.mm LTUG Aluminium cable in the excavated trench, threading through pipe, clamping on walls and terminating in as many ends using suitable single compression cable glands, lugs , sockets and other items required complete as per site conditions in a manner complete as directed by Section Engineer in charge at site. Note:- 4Cx50 sq.mm LTUG Aluminium Cable alone will be supplied departmentally. | — | 1000.00 | — | — | |
| — | — | — | Above/ 42000.00 Below/P | ||
| Laying/leading of 4 core 35 sq.mm LTUG Aluminium cable in the excavated trench, threading through pipe, clamping on walls and terminating in as many ends using suitable single compression cable glands, lugs , sockets and other items required complete as per site conditions in a manner complete as directed by Section Engineer in charge at site. Note:- 4Cx35 sq.mm LTUG Aluminium Cable alone will be supplied departmentally. | — | 1500.00 | — | — | |
| — | — | — | Above/ 36000.00 Below/P | ||
| Laying/leading of 4 core 25 sq.mm LTUG Aluminium cable in the excavated trench, threading through pipe, clamping on walls and terminating in as many ends using suitable single compression cable glands, lugs , sockets and other items required complete as per site conditions in a manner complete as directed by Section Engineer in charge at site. Note:- 4Cx25 sq.mm LTUG Aluminium Cable alone will be supplied departmentally. | — | 1500.00 | — | — | |
| — | — | — | Above/ 40500.00 Below/P | ||
| Laying of 63 mm dia High Density Polyethylene pipes in the excavated trench, clamping on walls / Steel members of platform shelter or elsewhere using suitable GI fixing arrangements and couplers and other accessories required at appropriate locations as per site conditions so that cable can be easily inserted and removed wherever need arises complete in a manner as directed by Senior Section Engineer-in-charge at site. Note: 63mm dia HDPE pipe alone will be supplied departmentally. | — | 1500.00 | — | — | |
| — | — | — | Above/ 25000.00 Below/P | ||
| Laying of 50 mm dia High Density Polyethylene pipes in the excavated trench, clamping on walls / Steel members of platform shelter or elsewhere using suitable GI fixing arrangements and couplers and other accessories required at appropriate locations as per site conditions so that cable can be easily inserted and removed wherever need arises complete in a manner as directed by Senior Section Engineer-in-charge at site. Note: 50mm dia HDPE pipe alone will be supplied departmentally. | — | 1000.00 | — | — | |
| — | — | — | Above/ 39200.00 Below/P | ||
| Installation, Testing and commissioning of 4 feet 30W LED light fitting Batten type suitable to work on 240V single phase 50 Hz AC with lamp and all standard accessories using suitable mounting and fixing arrangement as per industrial practices including supply connection from ceiling rose by using 3 core 1.5 sq. mm Fire Retardant Low Smoke PVC insulated, PVC round sheathed copper [White/Ivory colour] conductor flexible pendant chord conforming to IS:694/1990 or latest complete as per industrial standards and in a manner as directed by Senior Section Engineer in charge at site. Note: 4 feet LED 30W light fitting Batten Type with lamp alone will be supplied Departmentally | — | 400.00 | — | — | |
| — | — | — | Above/ 11580.00 Below/P | ||
| Installation, Testing and commissioning of 1200mm sweep BLDC ceiling fan onto the buildings or elsewhere using suitable clamping and fixing arrangement complete as per industrial practices including supply connection from ceiling rose by using 3 core 1.5 sq. mm fire retardant Low smoke PVC insulated, PVC round sheathed copper [White / Ivory colour] conductor flexible pendant chord conforming to IS:694/1990 or latest complete in a manner as directed by Senior Section Engineer in charge at site. Note: 1200mm sweep BLDC Ceiling fan alone will be supplied departmentally. | — | 60.00 | — | — | |
| — | — | — | Above/ 17520.00 Below/P | ||
| Installation, Testing and commissioning of 600mm sweep BLDC Air circulators onto wall / stanchion / rail post or elsewhere using suitable clamping arrangement made of 40mm X 6mm MS flat and MS plate of size of 300mm X 300mm X 6mm complete in a manner as per standard industrial standards and in a manner as directed by Section Engineer in charge at site. Note: 600mm sweep BLDC Air circulators alone will be supplied Departmentally. | — | 15.00 | — | — | |
| — | — | — | Above/ 45600.00 Below/P | ||
| Installation, Testing and commissioning of SMC box assembly similar to Sintex Catalogue reference No.GSJB- 1414 along with strip connector block, Neutral link, fuse bases and carriers onto lamp posts or elsewhere suing suitable clamping arrangements complete and in a manner as directed by Section Engineer incharge at site Note: SMC GSJB-1414 box, strip connector , neutral link, Earth link ,Fuse bases and fuse carriers, MS clamping arrangements alone will be supplied Departmentally. | — | 400.00 | — | — | |
| — | — | — | Above/ 64800.00 Below/P | ||
| Supply and stringing of overhead mains beneath platform shelters using 5 runs of 16 sq.mm PVC insulated and PVC sheathed multi stranded aluminium conductor cable duly by binding onto insulators of brackets provided vide item No. 14 below complete in a manner as directed by Section Engineer in charge at Site. Note: 1)5 runs of16 sq.mm cable are taken as 1m for unit purpose. 2)The earth wire should be lugged at both ends and has to be terminated in each MS clamp through Nuts and Bolts. | — | 300.00 | — | — | |
| — | — | — | Above/ 16290.00 Below/P | ||
| Supply and fixing of MS brackets, fabricated as per sketch enclosed, for supporting OH wire beneath platform shelters, mounted with 4 Nos. of porcelain vertical reel /shackle insulators and earth stud /bolt, finished with 2 coats of red primer and 1 coat of aluminium paint and complete with fixing arrangements as per drawing enclosed and in a manner as directed by Section Engineer in charges at site | — | 30.00 | — | — | |
| — | — | — | Above/ 136360.00 Below/P | ||
| Erection, testing and commissioning of 4 meter Double arm octagonal pole assembly onto the suitable RCC foundation and coping by using modern engineering practice including installation, testing and commissioning of LED luminaries including all wiring works from nearby junction box as per industrial standards complete in a manner as directed by Section Engineer in charge at site. Note: 1) The foundation design and drawing along with supporting IS specifications suitable for Octagonal poles supplied by Railways and as per site conditions should be submitted for approval before starting the work 2) Four metre Double arm Octagonal pole and accessories along with luminaries alone will be supplied departmentally. | — | 40.00 | — | — | |
| — | — | — | Above/ 20320.00 Below/P | ||
| Installation, Testing and commissioning of 70W LED street fittings using suitable GI tubular mounting arm bent to act as tubular support for anchoring arrangement onto walls including supply connection from ceiling rose/junction box or elsewhere by using 3 core 1.5 sq. mm Fire retardant low smoke PVC insulated, PVC round sheathed copper [White/Ivory colour] conductor flexible chord conforming to IS:694/1990 or latest as per industrial standards in a manner as directed by Section Engineer in charge at site. Note: 70W LED street light fittings alone will be supplied departmentally. | — | 80.00 | — | — | |
| — | — | — | Above/ 2116.00 Below/P | ||
| Installation, Testing and commissioning of time switch assembly comprising of: - a)1 No. timer switch with daily setting similar to L&T catalogue reference J648B1 [FM1 Quartz]. b)1 No. 3 pole 25A power contactor conforming to IS: 13947/P4/1993 or latest, c)1 No. 40A DP [MCB type] isolator conforming to IS: 13947/P3/1993 or latest, d)1 No. Neutral link etc. e)1 No. Earth link etc. f) Suitable rated control fuses all duly pre-wired and mounted on an appropriate sized well-seasoned wooden plank of thickness not less than 12 mm and duly housed into and powder coat finished enclosure of size not less than 300mm X 450mm X 300mm and made of 2mm thick Sheet Steel complete and provision of the same onto the wall or elsewhere using suitable fixing arrangements complete and in a manner as directed by Section Engineer in charge at site. Note: Timer switch, Power contactor, MCB, Neutral Link, Earth link, fuses, wooden box, Enclosures alone will be supplied Departmentally. | — | 4.00 | — | — | |
| — | — | — | Above/ 42960.00 Below/P | ||
| Installation, Testing and Commissioning of the LT Earthing arrangements duly by excavating/ auguring of earth pit in all kinds of soil/concrete surface or elsewhere, construction of masonry earth pit enclosure, provision of cover etc, complete including supply / leading / laying / burying and concealing of GI strip 32 X 6 mm along with proper sleeve from earth electrode to proposed MDB / SDB or elsewhere and in a manner as directed by Senior Section Engineer in charge at site. N o t e : 1) Masonry earth pit enclosure and cover shall be as per drawing number EL/P/TYPE/1022. 2) LT Earthling Electrode alone will be supplied Departmentally. | — | 30.00 | — | — | |
| — | — | — | Above/ 950.00 Below/P | ||
| Installation, Testing and commissioning of 4 feet 20W LED light fitting Batten type suitable to work on 240V single phase 50 Hz AC with lamp and all standard accessories using suitable mounting and fixing arrangement as per industrial practices including supply connection from ceiling rose by using 3 core 1.5 sq. mm Fire Retardant Low Smoke PVC insulated, PVC round sheathed copper [White/Ivory colour] conductor flexible pendant chord conforming to IS:694/1990 or latest complete as per industrial standards and in a manner as directed by Senior Section Engineer in charge at site. Note: 4 feet LED 20W light fitting Batten Type with lamp alone will be supplied Departmentally | — | 10.00 | — | — | |
| — | — | — | Above/ 174000.00 Below/P | ||
| Supply and drawing of inside mains using 2 runs of 2.5 sq. mm [from MCB DB to switch boards and from switch boards to switch boards or elsewhere] Fire Retardant Low Smoke PVC insulated unsheathed multistranded copper conductor cables of 1100V grade [conforming to IS:694/1990 or latest] duly inside the PVC conduit concealed/laid vide item No:24 below complete as per the specification enclosed and in a manner as directed by Section Engineer in charge at site. Note: - 2 runs of 2.5 sq. mm copper conductor are taken as 1m for quantity purpose. | — | 2000.00 | — | — | |
| — | — | — | Above/ 138000.00 Below/P | ||
| Supply and Drawing of earth wire using 1.5 sq.mm Fire Retardant Low Smoke PVC insulated unsheathed multi-stranded copper conductor cables of 1100V grade [conforming to IS:694/1990 or latest] duly along wires vide item No 20 above,22 below or elsewhere complete in a manner as directed by Senior Section Engineer in charge at site. | — | 6000.00 | — | — | |
| — | — | — | Above/ 208000.00 Below/P | ||
| Supply and drawing of inside mains using 2 runs of 4 sq. mm [from MCB DB to switch boards and from switch boards to switch boards or elsewhere] Fire Retardant Low Smoke PVC insulated unsheathed multistranded copper conductor cables of 1100V grade [conforming to IS:694/1990 or latest] duly inside the PVC conduit concealed/laid vide item No:24 below complete as per the specification enclosed and in a manner as directed by Section Engineer in charge at site. Note: - 2 runs of 4 sq. mm copper conductor are taken as 1m for quantity purpose. | — | 2000.00 | — | — | |
| — | — | — | Above/ 3400.00 Below/P | ||
| Installation, Testing and commissioning of the 300mm sweep BLDC Exhaust fan onto the buildings or elsewhere using suitable clamping and fixing arrangement complete as per industrial practices including supply connection from ceiling rose by using 3 core 1.5 sq. mm fire retardant Low smoke PVC insulated, PVC round sheathed copper [White / Ivory colour] conductor flexible pendant chord conforming to IS:694/1990 or latest complete as per industrial standards and in a manner as directed by Senior Section Engineer in charge at site. Note: 300mm sweep BLDC Exhaust fan alone will be supplied departmentally. | — | 20.00 | — | — | |
| — | — | — | Above/ 295000.00 Below/P | ||
| Supply and Concealing of 25mm dia rigid PVC conduits [IVORY colour] conforming to IS:9537 Part3(2021) or latest[ISI marked] with wall thickness not less than 2mm along with Bends, Junction Boxes and other items required along with manpower as per site conditions complete including cutting/ chipping the wall/ceiling or elsewhere and making good the same including replastering and painting wall to original condition /clamped at regular intervals, not exceeding 500 mm in a manner as directed by Section Engineer in charge at site as per industrial standards and as per specification for wiring/ rewiring enclosed. [Approximate length of PVC conduit] | — | 5000.00 | — | — | |
| — | — | — | Above/ 9408.00 Below/P | ||
| Supply of modular frame plate with matching cover plate suitable for 12 modules duly accommodated onto suitable modular switch board box made of 1.2mm thick GI Sheet complete with 16A SP MCB and recess mounting/ concealing the same onto the wall using suitable fixing arrangements including cutting/ chipping/ making recess on the wall or elsewhere and painting etc., complete including fixing ,testing and commissioning of Switches and sockets supplied vide Item SL.No's 33 34 35 36 including all internal wiring connections in a suitable manner as directed by Section engineer in charge at site. Note: - i)1 No. 12 Module frame plate with matching cover plate and 1 No. Modular GI box are taken as 1 No for quantity purpose and should match with IS codes with latest amendments. ii) Note: MCBs shall be of conforming to IS: 8828/1996 or latest with rated short circult capacity of 10kA | — | 16.00 | — | — | |
| — | — | — | Above/ 6336.00 Below/P | ||
| Supply of modular frame plate with matching cover plate suitable for 8 modules duly accommodated onto suitable modular switch board box made of 1.2mm thick GI Sheet complete with 16A SP MCB and recess mounting/ concealing the same onto the wall using suitable fixing arrangements including cutting/ chipping/ making recess on the wall or elsewhere and painting etc., complete including fixing ,testing and commissioning of Switches and sockets supplied vide Item SL.No's 33 34 35 36 including all internal wiring connections in a suitable manner as directed by Section engineer in charge at site. Note: - i)1 No. 8 Module frame plate with matching cover plate and 1 No. Modular GI box are taken as 1 No for quantity purpose and should match with IS codes with latest amendments. ii) Note: MCBs shall be of conforming to IS: 8828/1996 or latest with rated short circult capacity of 10kA | — | 16.00 | — | — | |
| — | — | — | Above/ 741.00 Below/P | ||
| Supply of modular frame plate with matching cover plate suitable for 4 modules duly accommodated onto suitable modular switch board box made of 1.2mm thick GI Sheet complete with 16A SP MCB and recess mounting/ concealing the same onto the wall using suitable fixing arrangements including cutting/ chipping/ making recess on the wall or elsewhere and painting etc., complete including fixing ,testing and commissioning of Switches and sockets supplied vide Item SL.No's 33 34 35 36 including all internal wiring connections in a suitable manner as directed by Section engineer in charge at site. Note: - i)1 No. 4 Module frame plate with matching cover plate and 1 No. Modular GI box are taken as 1 No for quantity purpose and should match with IS codes with latest amendments. ii) Note: MCBs shall be of conforming to IS: 8828/1996 or latest with rated short circult capacity of 10kA | — | 3.00 | — | — | |
| — | — | — | Above/ 630.00 Below/P | ||
| Supply of modular frame plate with matching cover plate suitable for 2 modules duly accommodated onto suitable modular switch board box made of 1.2mm thick GI Sheet complete ,recess mounting/ concealing the same onto the wall using suitable fixing arrangements including cutting/ chipping/ making recess on the wall or elsewhere and painting etc., complete including fixing ,testing and commissioning of Switches and sockets supplied vide Item SL.No's 33 34 35 36 including all internal wiring connections in a suitable manner as directed by Section engineer in charge at site. Note: - i)1 No. 2 Module frame plate with matching cover plate and 1 No. Modular GI box are taken as 1 No for quantity purpose and should match with IS codes with latest amendments. | — | 3.00 | — | — | |
| — | — | — | Above/ 86.00 Below/P | ||
| Installation, Testing and commissioning of Call Bell suitable for operation on 230 V, 50Hz, single-phase AC supply using suitable arrangement including supply connection from ceiling rose by using 3 core 1.5 sq. mm Fire retardant Low Smoke PVC insulated, PVC round sheathed copper (White/Ivory colour) conductor flexible pendant chord in a manner as directed by Section Engineer in charge at site. Note: Call Bell alone will be supplied Departmentally | — | 2.00 | — | — | |
| — | — | — | Above/ 2850.00 Below/P | ||
| Installation, Testing and commissioning of 4 feet 20W LED inverter light fitting Batten type with lamp and all standard accessories using suitable mounting and fixing arrangement as per industrial practices including supply connection from ceiling rose by using 3 core 1.5 sq. mm Fire Retardant Low Smoke PVC insulated, PVC round sheathed copper [White/Ivory colour] conductor flexible pendant chord conforming to IS:694/1990 or latest complete as per industrial standards and in a manner as directed by Senior Section Engineer in charge at site. Note: 4 feet LED 20W inverter type light fitting Batten Type with lamp alone will be supplied Departmentally | — | 30.00 | — | — | |
| — | — | — | Above/ 43350.00 Below/P | ||
| Wiring to light, fan, exhaust fan points [Medium point i.e. length between 3 to 6 mtr] by supply and drawing of 2 runs of 1.5 sq. mm Fire Retardant Low Smoke PVC insulated copper multi-stranded copper cables of 1100 V grade [conforming to IS: 694/1990 or latest] duly inside the PVC conduit concealed vide item No. 24 above complete with provision of 6A Modular switch conforming to IS: 3854/2023 or latest, 1 No. 3 plate ceiling rose conforming to IS: 371/1999 or latest and with all standard accessories complete and in a manner as directed by Section Engineer in charge at site. | — | 150.00 | — | — | |
| — | — | — | Above/ 18150.00 Below/P | ||
| Wiring to light, fan, exhaust fan points [Long point i.e. length between 6 to 9 mtr] by supply and drawing of 2 runs of 1.5 sq. mm Fire Retardant Low Smoke PVC insulated copper multi stranded copper cables of 1100 V grade [conforming to IS: 694/1990 or latest] duly inside the PVC conduit concealed vide item No. 24 above complete with provision of 6A Modular switch conforming to IS: 3854/2023 or latest, 1 No. 3 plate ceiling rose conforming to IS: 371/1999 or latest and with all standard accessories complete and in a manner as directed by Section Engineer in charge at site. | — | 50.00 | — | — | |
| — | — | — | Above/ 1320.00 Below/P | ||
| Supply of 6A Modular switches conforming to IS: 3854/ 1997 or latest in a manner as directed by Section Engineer-in charge at site. The unit shall be integrated into modular plates/boxes, including internal wiring terminations. | — | 60.00 | — | — | |
| — | — | — | Above/ 4560.00 Below/P | ||
| Supply of 6A Modular sockets conforming to IS: 1293/ 2019 or latest in a manner as directed by Section Engineer-in charge at site. The unit shall be integrated into modular plates/boxes, including internal wiring terminations | — | 60.00 | — | — | |
| — | — | — | Above/ 1260.00 Below/P | ||
| Supply of 16A Modular switches conforming to IS: 3854/ 1997 or latest in a manner as directed by Section Engineer-in charge at site. The unit shall be integrated into modular plates/boxes, including internal wiring terminations. | — | 20.00 | — | — | |
| — | — | — | Above/ 1600.00 Below/P | ||
| Supply of 16/6A Modular sockets conforming to IS: 1293/ 2019 or latest in a manner as directed by Section Engineer-in charge at site. The unit shall be integrated into modular plates/boxes, including internal wiring terminations. | — | 20.00 | — | — | |
| — | — | — | Above/ 5776.00 Below/P | ||
| Supply, Installation, Testing and commissioning of PVC junction box comprising of 1 No. 4 way 32A per way strip connector block and including fixing of 1 No. 3 plate ceiling rose conforming to IS: 371/1999 or latest and fixing the same close to lamp including wiring from junction box to lamp fitting by using 3 core 1.5 sq. mm fire retardant Low smoke PVC insulated, PVC round sheathed copper (White/Ivory colour) conductor flexible chord [conforming to IS: 694/1990 or latest]in a manner as directed by Sr. Section Engineer in charge at site. | — | 38.00 | — | — | |
| — | — | — | Above/ 920.00 Below/P | ||
| Installation, Testing and commissioning of 32A ,FP,MCB with Enclosure onto wall or elsewhere using suitable angle iron frame work and mounting and fixing arrangements as per industrial standards including all wiring and cable termination works at both Incoming and outgoing sides complete in a manner as directed by Section Engineer in charge at site. Note: 32A, FP, MCB with Enclosure alone will be supplied Departmentally. | — | 10.00 | — | — | |
| — | — | — | Above/ 186250.00 Below/P | ||
| Laying of RCC pipe of 150mm internal diameter and 25mm thick with suitable collar conforming to NP2 class as per IS No:458 including jointing using gunny bag and cement grouting complete including all works and materials required for successful commissioning as per site conditions and in a manner as directed by Section Engineer incharge at site. Note: 150mm dia RCC pipe alone will be supplied Departmentally | — | 1250.00 | — | — | |
| — | — | — | Above/ 36960.00 Below/P | ||
| Laying of precast Reinforced Cement Concrete (RCC) square-type cable chamber of internal clear dimensions 457x457x457 mm at the railway platform for laying electrical cables, including cutting, breaking, and dismantling of existing concrete or stone platform flooring, excavation of soil to the required depth, proper disposal of debris, providing two opposite knockouts/holes of 150 mm diameter for the entry and exit of cable protection pipes, lowering, aligning, leveling, and securely placing the precast chamber, grouting the pipe entry joints and packing all surrounding sides and gaps with a rich cement grout/mortar mix to ensure water tightness and structural stability, and supplying and fixing a matching precast RCC top cover with recessed lifting arrangements such that the finished top surface is perfectly flush and at the same level as the surrounding platform to avoid tripping hazards; all works complete as per standard drawings, technical specifications, and strictly according to the directions of the Section Engineer-in- Charge. Note: RCC cable chamber ,Top cover alone will be supplied Departmentally. | — | 21.00 | — | — | |
| — | — | — | Above/ 10280.00 Below/P | ||
| Installation, Testing and commissioning of 150W LED flood light fittings using suitable GI tubular mounting arm bent to act as tubular support for anchoring arrangement onto walls including supply connection from ceiling rose/junction box or elsewhere by using 3 core 1.5 sq. mm Fire retardant low smoke PVC insulated, PVC round sheathed copper [White/Ivory colour] conductor flexible chord conforming to IS:694/1990 or latest as per industrial standards in a manner as directed by Section Engineer in charge at site. Note: 150W LED flood light fittings alone will be supplied departmentally. | — | 40.00 | — | — | |
| — | — | — | Above/ 134000.00 Below/P | ||
| Erection, testing and commissioning of 300mm width x 50mm height made of 2mm thick hot dip galvanized Sheet steel complete with all accessories including coupler plate, supports fabricated MS flats of sufficient thickness and same duly supported from walls/ceiling/roof purloins/steel members of platform shelter/Foot over Bridge or elsewhere using intermediate supports of MS flats complete including carrying out all civil works incidental to provision/supporting/grouting of cable tray supports complete as per industrial standards ,site conditions and in a manner as directed by Section Engineer-in-charge at site. Note: 1)The cable tray supports shall be applied with two coats of red oxide primer and finished with two coats of bright aluminium paint. 2)CabIe tray alone will be supplied Departmentally | — | 400.00 | — | — | |
| — | — | — | Above/ 11120.00 Below/P | ||
| Erection testing and commissioning of wall / hanging /floor mounting type Non illuminated sign /direction boards in Full elliptical /haIf elliptical/semi elliptical shape and Flat (single side/ double side). The display sheet shall be of unbreakable 040 translucent polycarbonate heet of 2 mm thickness. The text / graphics matter visibility shall not be less than 160 deg. The approved colour text and graphics shall be printed / router cut on monomeric calendered vinyl of 70 um thickness and shall be firmly pasted on display sheets. The mounting arrangement shall be hanging, wall mounting, ceiling mounting, pole mounting or floor mounting and as per site requirement. The signage shall have the integral mounting arrangements with sturdy structural frame and ACP cladding on the back side of the signage to avoid rusting and entry of dust. The LED board shall have uniform Illumination. Note: Single side/Double Side Signage boards alone will be supplied Departmentally | — | 40.00 | — | — | |
| — | — | — | Above/ 75660.00 Below/P | ||
| Removal of existing rail posts by cutting at a depth as per site condition ground level including breaking of cement concrete and refilling with all accessories including bringing surface to original condition including refilling of Mass Concrete complete in a manner as directed by section engineer incharge at site. Note: The removed Rail posts must be handed over to SSE/Electrical/Power Office at Arakkonam. | — | 60.00 | — | — | |
| — | — | — | Above/ 5250.00 Below/P | ||
| Installation,Testing and commissioning of 24W Recess Round/square LED light fitting suitable to work on 240V single phase 50 Hz AC with lamp and all standard accessories using suitable mounting and fixing arrangement as per industrial practices including supply connection from ceiling rose by using 3 core 1.5 sq. mm Fire Retardant Low Smoke PVC insulated, PVC round sheathed copper [White/Ivory colour] conductor flexible pendant chord [conforming to IS: 694/1990 or latest] in a manner as directed by Senior Section Engineer in charge at site. Note: 24W Recess Round/square LED light fitting with lamp alone will be supplied Departmentally | — | 35.00 | — | — | |
| — | — | — | Above/ 6620.00 Below/P | ||
| Installation, Testing and commissioning of SPN MCB DB's with 32A,DP,MCB as Incomer along with 6 No's of 6A,SP,MCB's as feeder controls along with Cable adaptor box on to the wall using suitable angle iron frame work and including cutting/chipping and re-plastering and bringing back walls to original condition including painting the walls to original condition complete including all cabling and termination works at both incoming and outgoing ends complete as per site conditions and as per industrial practices in a manner as directed by Senior Section Engineer in charge at site. Note: MCB DB,MCB, Cable adaptor box etc alone will be supplied Departmentally | — | 10.00 | — | — | |
| — | — | — | Above/ 1240.00 Below/P | ||
| Installation, Testing and commissioning of Mobile charging assembly of size (360x300x100mm) made of CRCA sheet with minimum thickness 1.2mm consisting of 6A 1 way switch and 6A sockets along with 25A,30 mA, DP,RCCB with suitable fixing arrangements complete in a suitable manner as directed by Section Engineer incharge at site Note: Mobile charging assembly alone will be supplied Departmentally | — | 20.00 | — | — |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
technicaldocuments.pdf
ATTACHMENT
Checklistlessthan50Lakh.pdf
ATTACHMENT
GCCandACS1-12.pdf
ATTACHMENT
GeneralinstructionstoTenderers.pdf
ATTACHMENT
ImportantinstructionstoTenderers.pdf
ATTACHMENT
ModelformofBGbondwithinstructions.pdf
ATTACHMENT
NEFTFORM.pdf
ATTACHMENT
Payment_clause_for_LED_luminaries_and_BLDC_fansasper2026.pdf
ATTACHMENT
Special_conditions_of_Contract_Electrical.pdf
ATTACHMENT
StandardGuaranteecertificateformat.pdf
ATTACHMENT
Undertakings.pdf
ATTACHMENT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .