Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹3.4 CrAccepted-AOC 04 L BLOCK MARKET SECTOR 11 NOIDA 201301 UP GAUTAM BUDHA NAGAR | GAUTAM BUDDHA NAGAR | UTTAR PRADESH | 201301 | ₹3.4 Cr | L1 | Accepted-AOC L1 |
| 2 | L2₹3.6 Cr+₹14.0 L (4.11%)Rejected-AOC 5037 5038 URBAN ESTATE PH 1 PATIALA 147002 PUNJAB | PATIALA | PATIALA | PUNJAB | 147002 | ₹3.6 Cr+₹14.0 L (4.11%) | L2 | Rejected-AOC NOT L1 |
| 3 | L3₹3.5 Cr+₹13.0 L (3.81%)Rejected-AOC MATHOSHREE PLOT NO 55 SR NO 787 A BEHIND ASHWANI HOSPITAL GOVIND NAGAR NASIK 422 009 | NASIK | NASHIK | MAHARASHTRA | 422009 | ₹3.5 Cr+₹13.0 L (3.81%) | L3 | Rejected-AOC NOT L1 |
| 4 | L4₹3.6 Cr+₹21.6 L (6.31%)Rejected-AOC | ₹3.6 Cr+₹21.6 L (6.31%) | L4 | Rejected-AOC NOT L1 |
| 5 | Rejected-Technical FLAT NO 03 PANCHAVATI BUILDING ADARSH NAGAR CHICALIM GOA 403711 | SOUTH GOA | GOA | 403711 | - | - | Rejected-Technical Not enlisted in eligible category b(iii) |
| Sl No | Description | Qty | Unit | GEPS PROJECTS L1 | Sant Construction Co. L2 | M/s Prem Associates L4 | DURGAI ELECTRICALS L3 |
|---|---|---|---|---|---|---|---|
| 1.00 | Material and labour for Earth work in excavation by mechanical means (Hydraulic excavator)/ in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated in soft/integrated rock and disposal of surplus excavated soil as directed, within a lead of 50 m. | 508.8 | Cum | 251 ₹1,27,708.8 Lowest | 900 ₹4,57,920 | 720 ₹3,66,336 | 425 ₹2,16,240 |
| 2.00 | Material and labour for Cement concrete (1:4:8) type D2 as in foundations, filling and mass concrete all as specified and as directed. | 59.46 | Cum | 6,300 ₹3,74,598 | 7,700 ₹4,57,842 | 5,000 ₹2,97,300 | 4,500 ₹2,67,570 Lowest |
| 3.00 | Material and labour for RCC M30 design mix in Foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete | 183 | Cum | 8,400 ₹15,37,200 Lowest | 9,700 ₹17,75,100 | 9,000 ₹16,47,000 | 9,500 ₹17,38,500 |
| 4.00 | Material and labour for RCC M30 design mix in Walls, retaining walls, basement walls, ballast walls and the like; any thickness; above top of footings; including attached pilasters and buttresses | 53.32 | Cum | 8,800 ₹4,69,216 Lowest | 10,700 ₹5,70,524 | 9,000 ₹4,79,880 | 10,500 ₹5,59,860 |
| 5.00 | Material and labour for RCC M30 design mix in Columns, pillars, piers, posts and struts | 16 | Cum | 8,800 ₹1,40,800 Lowest | 11,000 ₹1,76,000 | 9,000 ₹1,44,000 | 12,500 ₹2,00,000 |
| 6.00 | Material and labour for RCC M30 design mix in Beams, cantilevers, bressummers, lintels over 1.5m span | 20 | Cum | 8,800 ₹1,76,000 Lowest | 11,500 ₹2,30,000 | 9,000 ₹1,80,000 | 12,500 ₹2,50,000 |
| 7.00 | Material and labour for RCC M30 design mix in Chajjas complete | 2.15 | Cum | 9,100 ₹19,565 | 13,000 ₹27,950 | 9,000 ₹19,350 Lowest | 13,000 ₹27,950 |
| 8.00 | Material and labour for RCC M30 design mix in Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like | 30 | Cum | 8,800 ₹2,64,000 Lowest | 9,700 ₹2,91,000 | 9,000 ₹2,70,000 | 13,000 ₹3,90,000 |
| 9.00 | Supply and fix of TMT bars 10mm dia & over cut to length bent to shape required including cranking bending spirally for hooping for columns, hooking ends and binding with and including MS wire (annealed) not less than 0.9 mm dia or securing with clips complete all as specified and directed | 41,600 | Kg | 90 ₹37,44,000 | 87 ₹36,19,200 Lowest | 114 ₹47,42,400 | 95 ₹39,52,000 |
| 10.00 | All as per item No.9 above but 6 to 8mm dia | 195 | Kg | 90 ₹17,550 Lowest | 90 ₹17,550 Lowest | 115 ₹22,425 | 95 ₹18,525 |
Tender Value
₹3.6 Cr
EMD Value
₹4.3 L
Closing Date
25 Jul 2025, 6:00 pmClosed
COL SAIKAT DE CWE NAVY VASCO
Commander Works Engineers (Navy) Vasco-da-Gama, Goa-403 802
UPGRADATION OF 11 KV TO 33 KV AND CONSTRUCTION OF MRS FOR ADDITIONAL LOAD REQUIREMENT AT INS GOMANTAK UNDER GE(P) VASCO, GOA
2025_MES_715873_1
85939
Open Tender
Civil Works
Item Rate
Vasco
Please refer Tender documents.
10 documents required · 10 mandatory
₹2,000
GE(P) Vasco
₹4.3 L
Yes
8 Sept 2025
20 Jun 2025
28 Jul 2025
20 Jun 2025
25 Jul 2025
11 Jul 2025
Amount
Material and labour for Earth work in excavation by mechanical means (Hydraulic excavator)/ in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated in soft/integrated rock and disposal of surplus excavated soil as directed, within a lead of 50 m.
Material and labour for Cement concrete (1:4:8) type D2 as in foundations, filling and mass concrete all as specified and as directed.
Material and labour for RCC M30 design mix in Foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete
Material and labour for RCC M30 design mix in Walls, retaining walls, basement walls, ballast walls and the like; any thickness; above top of footings; including attached pilasters and buttresses
Material and labour for RCC M30 design mix in Columns, pillars, piers, posts and struts
Material and labour for RCC M30 design mix in Beams, cantilevers, bressummers, lintels over 1.5m span
Material and labour for RCC M30 design mix in Chajjas complete
Material and labour for RCC M30 design mix in Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like
Supply and fix of TMT bars 10mm dia & over cut to length bent to shape required including cranking bending spirally for hooping for columns, hooking ends and binding with and including MS wire (annealed) not less than 0.9 mm dia or securing with clips complete all as specified and directed
All as per item No.9 above but 6 to 8mm dia
All as per item No.9 above but 5mm dia and over up to and including 10mm dia in stirrups, spacers and binders
Supply and fix of Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter, Use and waste of timber, putting together, erecting, striking and removal and maintaining in position until no longer required
Supply and fix of Formwork to faces of walls, retaining walls, abutments, parapets and staircase railings and similar work including attached pillasters, buttresses, etc.; vertical or to batter Use and waste of timber, putting together, erecting, striking and removal and maintaining in position until no longer required
Supply and fix of Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping) Use and waste of timber, putting together, erecting, striking and removal and maintaining in position until no longer required
Supply and fix of Formwork to chullah hoods, chajjas, troughs and similar items including edges Use and waste of timber, putting together, erecting, striking and removal and maintaining in position until no longer required
Supply and fix of Formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including sup- ports, overhangs, etc. also splays between floors and beams, etc. Use and waste of timber, putting together, erecting, striking and removal and maintaining in position until no longer required
Supply and fix of Formwork to fins, louvers, fascia Use and waste of timber, putting together, erecting, striking and removal and maintaining in position until no longer required
Supply and fix of Formwork to sides of pillars, posts, struts, piers, columns and stanchions
Supply and fix of Formwork to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floor and roofs n exc 20 cm wide and sides of RCC/ PCC bands in walls, horizontal or sloping and similar work exc 10cm but n exc 20cm wide, Use and waste of timber, putting together, erecting, striking and removal and maintaining in position until no longer required
Material and labour for Pre-cast cement concrete block masonry with solid blocks type C1 1:3:6 (20mm graded stone aggregate) set in CM 1:6 , exc. 10 cm in width and setting in mortar, complete
Material and labour for brickwork with fly ash brick, straight or curved on plan to any radius in half brick thick built in cement mortar 1:4 all as specified and directed.
Material and labour for Rendering 15mm thick in CM 1:4 on fair faces of brick work or concrete surfaces on wall finished even and smooth (without using extra lime or cement complete.
Material and labour for Rendering 10mm thick in CM 1:6 on fair faces of brick work or concrete surfaces on wall finished even and smooth (without using extra lime or cement complete.
Material and labour for Rendering 10mm thick in CM 1:6 on fair faces of brick work or concrete surfaces on ceiling finished even and smooth (without using extra lime or cement complete.
All as per item No.26 above butarea n.exc 1sqm
Supply and fix of Supply and fixing factory made uPVC door frame made of uPVC. extruded sections having an overall dimension (extruded section profile) 48x40 mm (tolerance ± 1 mm), with wall thickness 2.0 mm (± 0.2 mm), corners of the door frame Jointed with galvanized brackets and stainless steel screws, joints mitred and Plastic welded. The hinge side vertical of the frames reinforced by galvanized M.S. tube of size 19 X 19 mm and 1mm (± 0.1 mm) wall thickness and 3 nos. stainless steel hinges fixed to the frame complete all as specified by the manufacturer and as per directions of Engineer-in-charge
Supply and fix sheet glass 4.80mm thick plain frosted / pin headed quality and glazing fixed to aluminium ventilators/windows with glazing clips and neoprene gasket beading as directed in squares n.exc 0.50 sqm in each pane.
Supply and fix sheet glass 4.80mm thick plain frosted / pin headed quality and glazing fixed to aluminium ventilators/windows with glazing clips and neoprene gasket beading as directed in squares exc 0.50 sqm in each pane.
Material and labour for Green Marble work 18 to 20mm thick (table rubbed and polished) in steps, jambs, pillars, window cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with marble
Material and labour for machine cut kota stone slab flooring 20-25mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing, nosing complete.(Note:- Single piece if stone will be fix in the staircase treads/riser)
Material and labour for kota stone slab 20-25mm thick in skirting , dado, riser, steps and pillar laid over cement screed and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete. Note"-single piece of stone will be fix in the stair raiser.
Material and labour for screed bed or bedding layer of 15mm thick for laying of floor tiles in CM (1:6) complete all as specified and directed.
Material and labour for screed bed or bedding layer of 20mm thick for laying of floor tiles in CM (1:6) complete all as specified and directed.
Material and labour for non-skid coloured ceramic joint free tiles 7 to 8 mm thick area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm, in floors etc set and joints in near cement slurry and painted in white or colored cement to match complete all as specified and directed.
Material and labour for coloured Glazed ceramic tiles in vertical surface 350x 250x 7 mm/ 450X 350X 7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match
Supply and fix of MS Plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment
Supply and fix of MS Joist, channel, angle, or tee sections, fixed independently, without connecting plates, etc. (cut to ordinary lengths i.e. within 20mm of the length indicated)
Supply and fix of Purpose made butt hinges conforming to Fe-290 Gde-E-165 suitable for fixing to stone/ concrete door and window frames
Supply and fix of 1mm thick Steel rolling shutters, with out ball bearing, as specified including top cover, anchoring rod, hasp and staple and one shop coat of primer; erected in position as indicated, complete: push pull or manual type
Supply and fix of Safety lever locks mild steel with 4 levers for rolling shutters
Supply and fix of Ball bearing for rolling shutters
Material and labour for applying two coats of synthetic enamel paint over red oxide priming Surfaces of any description, over 10cm in width or girth, not otherwise described including preparation of new steel surfaces complete all as specified and directed.
Material and labour for preparation of new surface wall/ceiling by scrapping/rubbing, applying two coat of advanced anti-algal weather proof 100% acrylic smooth emulsion with silicon additives, over a coat of fiber reinforced elastomeric liquid water proofing membrane , on new plastered surfaces walls/ceiling and cornices brooming down or steel wire brushing scrapping down with steel scrapper smoke soot moulds moss and efflorescent slats barding oil and greasy spots etc and making proper surface by applying ready mix preparatory wall care putty wherever required complete all as manufacturers instructions. Note The Application of paint to be done by the authorised, applicators of approved make and contractor shall submit a written guarantee with the authorized dealer of 8 yrs for any type of colour of fading, peeling, flaking growth of fungus, seepage of water through the paint applied area any other damages to the paint). Also the dealer shall appoint a person to inspect and validate the application of the system is stage wise manner
Material & Labour for applying two coat of oil acrylic emulsion distemper on newly surfaces of wall over a coat of primer over wall care putty including preparation complete.
Material and labour for 2mm thick putty on newly plastered ceiling and applying two coat of acrylic distemper over a coat of primer including preparation of new plastered ceiling surface.
Material and labour for stone Broken or boulders bricks of gauge n exc. 63 mm, deposited, spread and leveled in layers n exc. 15 cm thick, watered and rammed to a true surface
Material and labour for 75 mm thick PCC (1 : 3 : 6) type C2 (40mm graded aggregate) Cement concrete as in plinth protection and flooring.
Returning, filling in, including spreading, leveling, watering and well ramming in layers not exc 25 cm.
Removing excavated material exc. 50m but n.exc 250m and depositing where directed at a level n exc. 1.5 m above the starting point
Filling under floors or in foundations including watering and consolidation
Material and labour for 100mm thick Plain Cement concrete type D- 2, 1:4:8 (40mm graded aggregate)
Material and labour for 100mm thick Plain Cement concrete type B- 1, 1:2:4 (20mm graded aggregate)
Supply and fix Rotational mounded polyethylene water storage tanks (cylindrical vertical with closed top thread type) hoisted and fixed in Position all as specified in SSR part I of capacity 500 Ltrs.
Supply and fix 20mm Ball valves high pressure of PTMT with epoxy coated Aluminium rod & high-density plastic bal Screwed for Iron pipe and fixed (Minimum weight 15mm-142 gms- 20mm-210 gms/25mm-455 gms/ 40mm- 690 gms
Supplying and laying of 20 mm dia, PVC pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as speculated
Supplying and laying of 25 mm dia, PVC pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as speculated
Supply and fix in repair 20mm Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed
Supply and fix PVC connections 15mm Size with PTMT nuts of length 450mm.
Supply and fix concealed angle cock fancy type chromium plated with capstan head, screwed down, high pressure screwed both ends for 15 mm bore iron pipe or for unions and fixed in repairs complete, all as specified and directed.
Supply and fix Vitreous china Wash Hand Basin, white, flat back of size 550x400mm excluding taps, waste pipe, chain and plug and porcelain stopper out including brackets including waste pipe
Supply and fix 32mm dia CP waste coupling all as specified and directed.
Supply and fix Vitreous china wash down water closet (pedestal pattern ) white (excluding fixing bolts flushing cistern and flush pipe ).
Supply and fix PVC low level flushing cistern 10 Ltrs capacity with complete accessories, PVC flush pipe, PVC over flow pipe, etc. and connected to water closet as per manufactures instruction and as directed by the Engineer in charge including removal of existing cistern etc.
Supply and fix in plastic water closet seat cover, white closed pattern with flat bottom and cover and mild steel chromium plated or aluminium hinging device of make fixed with CI brackets
Supply and fix for over head shower rose & shower arm with revolving joint and 100mm dia round shaped single flow (ABS body chromium plated all as specified and directed.,
Supply and fix corner glass shelf 300mm, matt finished, chromium plated (MCH/Colour CP) with bracketall as specified and as directed by the Engineer in charge.
Supply and fix cabinet mirror of size 330 mm X 430 mm with shelf as fixed in repairs all as specified and directed
Supply and fix in health faucet (hand shower with 1 M flexible tube with wall hook, chromium plated all as specified and as directed by the Engineer in charge.
Supply and fix 15mm Bib taps, cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed but fancy type.
Supply and fix of Pillar taps, fancy type, cast copper alloy, with capstan heads, chromium plated,screwed down high pressure, with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly-nuts, screwed for iron pipe
Supply and fix of 15mm Stop valves, cast copper alloy, screwed down, high pressure,with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed but fancy type, chromium plated
Material and labour for PVC (SWR) floor trap 75 mm dia plain with grating including jointing with solvent cement
Supply and fix PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to wall etc of 110mm dia including demolition and breaking up existing pipe.
Supply and fix PVC (SWR) pipes single socketed in any length with rubber ring joints laid in trenches or in floors etc of 110mm dia including demolition and breaking up existing pipe.
Supply and fix PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to floor/trenches etc of 75mm dia including demolition and breaking up existing pipe.
Supply and fix PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to wall etc of 75mm dia including demolition and breaking up existing pipe.
Supply and fix PVC SWR bend with oval access door of any radius 75mm dia complete
Supply and fix of PVC SWR bend with oval access door any radius 110 mm dia complete
Supply and fix of PVC SWR vent cowl 110mm bore
Supply and fix of PVC SWR vent cowl 75 mm bore
Material and labour for rendering 10 mm thick in CM 1:3 as in roof slab, Chajja drops, parapet roof on brick or concrete surfaces with water proofing compound(WPC measured and paid separately ) including roughening surfaces of old concrete by picking, sweeping clean and washing down with water to remove dust etc.
Preparation of concrete surfaces by scrubbing down with steel brushes and cleaning with water to remove all loose dirt / dust etc and applying the following roof treatment on roof/parapet complete all as directed:- (a) Applying 1st course of bituminious primer confirming to IS-3384 @ 0.4 lit/sqm over the screed bed. (b) Applying 2nd course of a coat of binding material with blown type bitumen of grade 85/25 heating to working temperature of 180 0 C and applied @ 1.2 kg/sqm. (c) Applying 3rd course of APP (Atactic polypropylene) based polymeric membrane minimum weighing 3.6 kg/sqm and minimum 3 mm thick reinforced with polyester non wove fabric (wt not less than 150 gms/sqm) laid with 75 mm side overlap and 100 mm overlap by forced / torch application as per manufactures instructions. (d) Applying 4th course of a coat of bonding material with blown type bitumen of grade 85/25 heating to working temperature of 180 degree C and applied @ 1.2 kg/sqm over APP membrane, complete all as specified and directed. (e) Applying 5th course of a coat of aluminium paint @ 200gm/sqm (min) in two coat .
Supply and fix of PVC (SWR) gully trap 125/110 mm, setting and jointing with solvent cement
Material and labour for Treating the backfill in contact with foundation at the rate of 7.5 litres of emulsion per square metre of vertical surface (Area of the sub structure in contact with backfill to be measured)
Material and labour for Treating the top surface of filled earth at the rate of 5 litres of emulsion per square metre of surface
Material and labour for Treating the soil under plinth protection at the rate of 5 litres of emulsion per square metre of surface area
Treating the soil along with external perimeter of building at the rate of 2.25 litre of emulsion per metre of the perimeter wall
Material and labour for Rendering 10mm thick in CM 1:4 on fair faces of brick work or concrete surfaces on wall finished even and smooth (without using extra lime or cement complete.
Earth work in excavation as in ordinary rock by mechanical means (Hydraulic excavator) means over areas (exceeding 1.5m in depth not exceeding 3.00m, 1.5 m in width as well as 10sqm on plan) including getting out and disposal of excavated earth lead up to 50 m and lift up to 1.5m, as directed by Engineer-in-charge.
Earth work in excavation as in ordinary rock by mechanical means (Hydraulic excavator) means over areas (exceeding 3.00m in depth not exceeding 4.50m, 1.5 m in width as well as 10sqm on plan) including getting out and disposal of excavated earth lead up to 50 m and lift up to 1.5m, as directed by Engineer-in-charge.
Earth work in excavation as in ordinary rock by mechanical means (Hydraulic excavator) means over areas (exceeding 4.50m in depth not exceeding 6.00m, 1.5 m in width as well as 10sqm on plan) including getting out and disposal of excavated earth lead up to 50 m and lift up to 1.5m, as directed by Engineer-in-charge.
Supply and fix 110mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls/laid in wall as in weep holes complete all as specified and directed.
Excavating in post holes (or similar holes) each n exc 0.5 cum, getting out in soft and disintegrated rock., returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25cm complete all as specified and directed.
Surface excavation n.exc 30cm deep and averaging 15cm deep and getting out in soft/disintegrated rock.
Material and labour for PCC Type B-1 1: 2:4 (20mm graded aggregate) as in coping including necessary formwork
Material and labour for preparation of new surfaces & applying two coats cement base paint over a coat of alkali resistant priming paint complete all as specified and directed.
Supply and fix Mild steel work like angle iron, flat iron etc in posts and struts in fencing including to shape as directed, drilling holes, notching for wire etc conforming to Fe 290 Gde E-165 all as specified and as directed.
Supply and fix Mild steel screw bolts (machine made) with hexagonal /square heads at one end and screwed the other or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square length of bolt exceeding 5 cm and not exceeding 10 cm long and dia of neck 12 mm all as specified and as directed.
Supply and fix PVC coated MS galvanised chain link fencing of size 75 x 75mm of any type of standard, rail straining bolts etc including provision of binding wire all as specified and as directed..
Material and labour for 100mm thick PCC type C-2, 1:3:6 (using 40mm graded aggregate), as in sub base of floor, all as specified and directed by Engr-In-Charge.
Material and labour for 100mm thick PCC type D-2 , 1:4:8 (using 40mm graded aggregate), as in sub base floor , all as specified and directed by Engr-in-charge.
Material and labour for applying two coats of synthetic enamel paint over red oxide priming Surfaces of any description, n. exc 10cm in width or girth, not otherwise described including preparation of new steel surfaces complete all as specified and directed.
Supply and fix Framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165 and including for portion framed and hung as gates, including pintle hinges, stops, hand-made sliding bolts etc, complete all as specified and directed.
Material and labour for precast cement concrete slab for manhole/drain covers slab 1:2:4 type B1 using 20mm graded stone aggregate set in CM 1:4 complete all as specified and as directed.
Supply and fix for 75mm dia PVC (SWR) pipes single socketed, in any length with rubber ring joint fixed in walls for weep holes complete all as specified and directed.
Material and labour for cement concrete Type B1 1:2 : 4 (20mm graded aggregate) as in surface channels and drains complete all as specified and directed.
Material and labour for plain cement concrete in benching (surface channels and drains) type B2 1:2:4 (20 mm graded stone aggregate).all as specified and as directed.
Material and labour for plain cement concrete type B1 1:2:4 (ung 20 mm graded stone aggregate) in coping, including weathering, slightly rounded or chamfered angle and throating, as directed.
Material and labour for rendering cement plaster 1:4 , 15 mm thick using water proofing compound on fair faces of brick work or concrete surfaces finished even and smooth without ung extra cement.
Supply only liquid water proofing compound.
Supply and fix 150 mm dia PVC (SWR) pipes single socketed in any length with rubber rings joints laid in trenches or in floors all as specified and as directed..
Material and labour for concrete bed, type C-2, 1:3:6 for drain pipes including packing under and haunching against the des of pipes after they are laid and tested for150mm pipes all as specified and as directed.
Supply and fix 75mm dia cast iron (sand cast pipe) soil, west, vent pipes of any length with or without ears with cement joints fixed to wall all as specified and as directed..
Supply and fix cast iron cowl 75mm dia.
Supply and fix only Septic tank hume pipe 10 users capacity exc. in soft disintegrated rock, pcc filling etc including RFR and disposal of surplus spoil complete.
Construction of Soakage well 1.8m dia and 3.0m deep , Excavation in hard soil/ Soft Rock. Foundation with PCC (1:3:6) , Fly ash brick work in CM (1:4), RCC cover slab including Precast Manhole cover , and filling with brick bats complete all as per CWE (N) Drg No : AFB/TD/120 Dt: 07/08/99 Sheet NO: ½ & 2/2
Material and labour for Hard core in broken stone or boulders of gauge n exc 63 mm, deposited, spread and leveled in layers n exc 15 cm thick, watered and rammed to a true surfaces complete all as specified and directed.
Plain cement concrete 1:4:8,Type D2 (using 40 mm graded stone aggregate), 75mm thick as in sub base all as specified and as directed.
Providing and laying 80mm thick factory made chamfered edge cement concrete paver block of M-30 grade with approved colour, design & pattern as in footpath, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of coarse sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with fine sand and cutting of paver block as per required size and pattern, finishing and sweeping extra sand; complete.
Material and labour for providing, cement concrete type B1, 1:2:4 (20mm graded aggregate) as in kerbs or mud stops, rounded or chamfered on edges and including necessary formwork(straight or curved) all as specified and as directed.
Material and labour for moorum/red bajri filing in floors or pavings, laid in layers n exc 15 cm thick spread, leveled and rammed including watering.
Material and labour for PCC 1:5:10 type E2 using 40mm graded aggregate in foundations, filling and mass concrete complete.
Material and labour for PCC 1:2:4 type using 20mm graded aggregate in foundations, filling and mass concrete complete all as specified and directed.
Excavation in trenches in hard/dense soil not exceeding 1.5 m width and not exceeding 1.5m in depth getting out complete.
Excavation in trenches in soft/disintegrated rock not exceeding 1.5 m width and not exceeding 1.5m in depth and getting out complete.
Cutting existing steel/GI/CPVC/CI tubing for alterations or additions for any dia/size including inserting necessary fitting such as tee, elbow, reducer in position including threading work complete.
Supply and laying/fixing of 25 mm dia CPVC pipes with all fittings such as elbow, bends, sockets, nipples and union etc SDR 11 and plain CPVC SDR 11 fitting on wall/ceiling or laying in trenches floor including all fittings/ accessories complete.
Supply and laying/fixing of 40 mm dia CPVC pipes with all fittings such as elbow, bends, sockets, nipples and union etc SDR 11 and plain CPVC SDR 11 fitting on wall/ceiling or laying in trenches floor including all fittings/ accessories complete.
Supply and fix gate valve with iron wheel head screwed both ends for iron pipe and fixed in 25 mm dia pipe complete.
Supplying and making indoor cable end terminations with heat shrinkable jointing kit with all accessories including lugs suitable for 11 KV (earthed) 3 core 185 sqmm XLPE aluminium conductor cable as required.
Supplying, laying or fixing or passing through pipe, testing and commissioning 1100 volts grade PVC insulated PVC sheathed steel tape / wire armoured underground stranded aluminium conductor cable of following nominal cross sectional area:-
(a) 10 sq mm 4 core
(b) 120 sq mm 3.5 core
Supplying, laying, testing and commissioning XLPE insulated screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) with stranded aluminium conductor 6.35 KV(UE)/11 KV(E) of size 185 sqmm 3 core complete.
Supplying and laying synthetic Rubber insulated mat 2.5 mm thick class 'B' to withstand 45 KV dielectric strength ISI marked as per IS-15652:2006 having size 2 m x 1 m. for electrical shock safety up to 11 KV voltage complete.
Supplying and laying synthetic Rubber insulated mat 3 mm thick class 'C' to withstand 65 KV dielectric strength ISI marked as per IS-15652:2006 having size 2 m x 1 m. for electrical shock safety up to 33 KV voltage complete.
Supply and fix LED street light fixture 70 watt powder coated pressure die cast aluminum body with driver Input voltage: 140-270 Volt AC, freq 50 Hz, Operating temp range -15 deg to 50 deg centigrade, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2 , P. F.≥0.95, IP- 66,IK-10, CRI >80, under voltage and over voltage protection, EMIEMC as per CISPR -15, lenses for beam angle as per IESNA type I/II/III as per the requirement, life time (LED, Driver & electrical circuitry) of minimum 50000 burning hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 5700°K /6000°K/6500°K (As per ANSI Bin), SDCM (Standard Deviation Color Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect including connections with suitable size FRLS, PVC insulated copper conductor cable and earthing et. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output. LM 79 & LM 80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminum housing such that LED junction temperature shall not rise above 90°C).
Supply and fix copper strip for earth continuity conductor or main earthing lead fixed to wall or recess or chases or buried in ground or drawn in pipes or any other indicated situation (to be measured beyond 7.5 m from earth pit) of following sizes:-
Material and labour for earthing with galvanized steel earth plate electrode 600 mm x 600 mm x 6 mm buried directly in ground vertically to a depth not less then 2.25 meter below normal ground level with top edge of the plate not less then 1.50 meter below normal ground level connected to galvanized earth strip 32 x 6 mm by means of bolts, nuts, check nuts and washers complete up to and including test point made out of 40 x 6 mm aluminium flat including earthing pit, charcoal common salt ,earth strip 32 x 6 mm up to 7.5 m, 20 mm dia medium grade GI watering pipe ,G.I. protection pipe 40 mm dia up to 7.5 m long, PCC pit in PCC 1:2:4 type B-1 using 20 mm graded stone aggregate, CI pit cover with locking arrangement all as shown in electrical plate No. 3 of SSR Part-1 (2009) including excavation & earth work as required.
Material and labour for earthing with copper earth plate electrode 600 mm x 600 mm x 3.15 mm buried directly in ground vertically to a depth not less then 2.25 meter below normal ground level with top edge of the plate not less then 1.50 meter below normal ground level connected to earth plate with copper strip 32x6 mm by means of bolts ,nuts ,check nuts and washers up to and including test point made out of 40 x 6 mm bronze flat including earthing pit, charcoal common salt, earthing lead 32x6 mm up to 7.5 m long, 20 mm dia medium grade GI watering pipe, GI Protection pipe 40 mm dia up to 7.5 m long, PCC pit in PCC 1:2:4 type B-1 using 20 mm graded stone aggregate, CI pit cover with locking arrangement all as shown in electrical plate No. 3 of SSR Part-1 (2009) including excavation and earth work as required.
Supplying, installing, testing & commissioning indoor type floor mounted air insulated metal clad 33 kV, VCB Panel 4 way (1IC+3OG), totally enclosed, fully interlocked draw out type breaker as per IEC 62271-100 & IEC 62271-200 with latest amendments, single break, trip free mechanism, manually charged and auto/ manually closing breaker with short circuit fault level of 26.3 kA for 3 sec, fully internal arc tested in all three chambers at 26.3 kA for 1 sec with self contained, fully interlocked, breaker featured with mechanical on/off indicator with hand trip device, spring release coil, S/T coil and auxiliary switch of 6 NO+ 6 NC and equipped with following switch gears and accessories including cable end termination box for connection of 3Cx185 sqmm XLPE 33 KV cable (cable entry from bottom side). The basic insulation level of entire panel shall be 70KV(RMS) / 170KV(Peak). Panel shall have micro processor based numerical relay with O/L, S/C, instantaneous, E/F protection. Arc flash protection. HT panel shall be compatible for SCADA/ BMS applications and shall be complete with compatible hardwares and meters provided with RS 485 port with modbus There must be a viewing window on VCB chamber door as per Internal arc test report. Details of incoming & outgoing VCBs are as under:-
Incoming VCB
(a) Vacuum Circuit Breaker, 800 A, 33 KV, 50 Hz, 3 pole, 26.3 kA (3 Sec), completely sealed pole assembly.
(b) Dual core dual ratio resin cast 3 CTs 50-25/1-1A of accuracy class 0.5 for metering and 5P10 for protection. with adequate burden.
(c) Resin cast PT with ratio 33 KV / √3 / 110 V / √3, 50 VA, Class 0.5 with HT fuses.
(d) Digital Multifunction Meter (KWH, KVAR, PF, Frequency, Current & Voltage) with communicable RS 485 port.
(e) Master Trip circuit relay.
(f) Microprocessor based IDMT relay (3OC+1E/F).
(g) Trip/Neutral/Close Breaker Control Switch
(h) Heater with thermostat to work on 230 V AC.
(j) Indication by LED lamps to work on 24 V DC for Breaker Close / Open / Trip / Spring charged / Circuit healthy/ DC supply failure/ VCB open / R-Y-B phases.
(k) Push buttons as required
Outgoing VCBs - 3 Nos
Each outgoing VCB shall have following accessories
(a) Vacuum Circuit Breaker - 630 A, 33 KV, 50 Hz, 3 pole, 26.3 kA (3 Sec), completely sealed pole assembly.
(b) Dual core resin cast 3 CTs 25/1-1A of accuracy class 0.5 for metering and 5P10 for protection. with adequate burden.
(c) 12 Window display annunciator with accept & reset push buttons for indication of Oil temperature indication (Alarm & Trip), Winding temperature indication (Alarm & Trip), Buchholtz (Alarm & Trip), DC supply failure & 33 KV incoming VCB open.
(d) Digital Multifunction Meter (KWH, KVAR, PF, Frequency, Current & Voltage) with communication port.
(e) Master Trip circuit relay.
(f) Microprocessor based IDMT relay (3OC+1E/F).
(g) Trip/Neutral/Close Breaker Control Switch
(h) Heater with switch & thermostat to work on 230 V AC.
(j) Indication by LED lamps to work on 24 V DC for Breaker Close / Open / Trip / Spring charged / Circuit healthy/ R-Y-B phases
(k) Aux Relay for transformer protection (The rating of power transformer is 33KV/11 KV, 1250 KVA).
(k) Push buttons as required
Note:- Any other fittings/ accessories necessary for satisfactory operation of the VCB Panel shall be provided whether it is specifically mentioned or not in the item.
Supplying, laying, testing and commissioning XLPE insulated screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) with stranded aluminium conductor 19 KV(UE)/33 KV(E) of size 185 sqmm 3 core complete.
Supplying and making indoor cable end terminations with heat shrinkable jointing kit with all accessories including lugs suitable for 33 KV (earthed) 3Cx185 sqmm XLPE aluminium conductor cable as required.
Supplying, installing, testing & commissioning outdoor type step down transformer 33 KV/11 KV, 1250 KVA, AC 3 phase, 50 Hz confirming to IS:2026 (Part 1 to 5), copper wound (Electrolytic grade 99.9% pure copper), core made of Prime quality CRGO steel, MOH grade or better, ONAN type cooling, delta connected on primary side (HV side) and star connected on secondary side (LV side) in accordance with vector group DY-11 with neutral brought out on secondary and having tapings at ±2.5%, ±5% and ±7.5% OFF LOAD tap changing gear provided on HV winding, first filling of filtered dehydrated oil conforming to IS:335 with and including following standard accessories:-
(a) Oil conservator with filling hole and drain cock.
(b) Oil level gauge with 50, 300 & 900C marking
(c) Oil seal type transparent breather with silica gel.
(d) Air release plug.
(e) Two numbers earthing terminals with lugs.
(f) OFF LOAD changing gear.
(g) Drain valve/ filter valve.
(h) Buchholtz relay (double float) with shut off valve on both side.
(j) Radiators with valves.
(k) Lifting lugs with fastening holes.
(l) Four numbers jacking pads.
(m) Two numbers inspection covers.
(n) Two numbers thermometer pockets.
(o) WTI and OTI dial type 150 mm dia with alarm and trip contact and having provision for transmitting temperature to VCB panel.
(p) Wireless thermal sensors along with ZigBee concentrator & necessary arrangement to get the data of the same.
(q) Pressure release device
(r) Rating and diagram plate and flow chart
(s) Marshalling box
(t) HV and LV both side cable end box
(u) Bottom mounting channel
(v) Flanged bi-directional rollers
(w) Explosion vent with diaphragm
(x) Valve in equalising pipe
(y) Pulling eyes
(z) Any other fittings/ accessories necessary for satisfactory operation of the transformer shall be provided whether it is specifically mentioned or not in the item.
Supplying, installing, testing & commissioning outdoor type step down transformer 33 KV/0.433 KV, 100 KVA, 3 phase, 50 Hz, ISI marked as per IS:1180 (Part-1)/2014 with amendment No 4, EEL-2, Vector group Dyn11, ONAN cooling, copper wound (Electrolytic grade 99.9% pure copper), core made of Prime quality CRGO steel, MOH grade or better, OFF load tap changing arrangement on HV side in steps of ±2.5%, ±5% and ±7.5% with cable end box on both HV/LV side and first filling of filtered dehydrated oil conforming to IS:335 with following standard accessories:-
(a) Lifting lug for transformer and tank.
(b) Earthing terminal rating and diagram plate.
(c) Air release device.
(d) Oil filling inlet pipe with plug.
(e) Drain outlet pipe with brass gate valve.
(f) Conservator tank with oil level indicator
(g) Oil seal type transparent breather with silica gel
(h) Two numbers inspection covers.
(j) Two numbers thermometer pockets.
(k) WTI and OTI dial type 150 mm dia with alarm and trip contact and having provision of transmitting temperature to remote VCB panel.
(l) Any other fittings/accessories necessary for satisfactory operation of the transformer shall be provided whether it is specifically mentioned or not in the item.
Supplying, installing, testing & commissioning of 11 KV, 630 amp, 3 phase, 50 Hz, 21 KA for 3 second, dust & vermin proof with copper bus bars, fully interlocked, extensible type indoor Ring Main Unit (RMU) consisting of two numbers 630 Amp manual load break switch (for Incoming side) & one number 630 amp VCB module motorised operation (outgoing side). All live parts of the switchboard like VCB, bus bars etc should be enclosed in robotically laser welded single stainless steel tank 3 mm thick having IP 67 degree of protection filled with SF6 gas as dielectric medium. RMU should be complete with all accessories such as dual core Ring CTs, self powered microprocessor based numerical relay 3 O/C + 1 E/F, manometer, Air insulated metering module, voltage indications, mechanical indications for breaker ON / OFF / Trip / Spring charged duly powder coated in Siemens grey shade RAL 7032 confirming to all relevant IS & IEC standards including the following items:-
VCB module shall have following accessories :- (a) 11 KV, 630 amp, 21 KA for 3 second manually operated vacuum circuit breaker. (b) Push buttons for breaker ON/OFF (c) Self Powered Microprocessor Relay (3 O/C + 1 E/F) with rechargeable battery & power pack. (d) Three numbers dual core, dual ratio 11 KV CTs 125-75/1+1 A, 2.5 VA, accuracy class 5P10 for protection & class 0.5 for metering duly connected at 75/1-1A amp and programmed for 1250 KVA load from factory. (e) Mechanical Indications for breaker ON, OFF, EARTH, TRIP, Spring Charged-Discharged. (f) Right angle boots for cable terminations. (g) Power pack 2x12 V, 12 AH with compatible battery charger. (h) Mimic diagram on front panel complete with status indicators.
Air insulated metering module comprising of :- (a) Resin cast PTs of the ratio 11 kV / √3 / 110 V / √3, 50 VA, Class 0.5 with HT fuses on primary side and MCB on secondary side. (b) Digital Multifunction Meter (KWH, KVAR, PF, Frequency, Current & Voltage) (c) LED bulb for illumination (d) Space Heater with thermostat
Make : Simens (8DJHST)/ Schneider (FBX) / ABB (SafePlus- XT).
Note:- All items / components / accessories which are useful and necessary for efficient working of the RMU shall deemed to be included in it irrespective whether such items are specifically mentioned or not in the item
Supply and fix DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc ISI marked as per IS-16205 (Part-24) including cutting/ jointing laid in existing trenches, wall, floor etc as required for the following nominal sizes:-
(a) 160 mm outer dia and 135 mm inner dia
(b) 40 mm outer dia and 32 mm inner dia
Supplying, installing, testing & commissioning floor mounted float cum boost SCR controlled 24 volts, 25 A, single phase 3 feeder Battery charger with inbuilt battery compartment not less than 2 mm thick powder coated suitable for 2x12 V, 100 AH batteries and DC distribution board in a common cubical. Charger shall have a double wound transformer (provided with best quality CRGO laminations for high efficiciency), an SCR / diode bridge, smoothing choke, capacitors and electronic circuits for controlling the voltage. The charger should have fitted with a digital voltmeter & ammeter, LED indications for mains supply, mode of charging (float or boost), battery polarity reverse & over load conditions. It shall have protection for over load, short circuit, reverse polarity & surge / transient. The charger have to alarm on fuse blowing & short circuit. All protections to charger & its meters shall be provided with suitable rating MCB only. The output voltage regulation have to be better than 1% and load regulation better than 2%. The other technical specifications shall be as under:-
(a) Input working voltage - 180-270 volts
(b) Nominal input voltage - 230 volts AC, 50 Hz, single phase.
(c) On load input power factor - > 0.80
(d) On load unit watt efficiencies - > 80%
(e) No load losses of complete charger - <10%
(f) Ripple contents on load (rms) - 1% to 5%
(g) Over load - 110% for 30 minutes and should give visual indication for over load condition.
(h) Boost charging - 2.4 volts / cell
(j) Float charging - 2.15 volts / cell
(k) Float cum boost charging - Automatically changes from one state to another state as per battery condition and should give the visual indication for either float or boost based on charging mode.
(l) Reverse polarity - No damage should be caused. A visual indication should appear with an audio alarm.
Supplying, installing, testing & commissioning 12 volts, 100 AH, SMF, VRLA rechargeable batteries including necessary connections with suitable size copper conductor cable, battery terminals etc as required.
Supplying, laying, testing & commissioning of armoured solid core copper control cable with proper end terminations of following nominal sizes:-
(a) 2.5 sqmm 12 core
(b) 2.5 sqmm 4 core
(c) 2.5 sqmm 2 core
Supplying, installing, testing & commissioning floor mounted indoor type cubical MV panel board, suitable for 415V, 3 phase, 4 wire 50 Hz, AC supply design veried as per IEC-61439 (Part-1 & 2) of 2020 fabricated from stainless steel sheet (SS 316) both side polished totally enclosed, dust, weather & vermin proof, 2 mm thick having TPN copper busbar of rating 1.5 times that of controlling MCCB supported on SMC insulators with short circuit withstand capacity 35 MVA for 1 second, bottom base channel of MS section not less than 75 mm x 50 mm x 5 mm thick, entire panel shall have a common copper earth bar of size 25 mm x 5 mm at the rear with 2 Nos earth stud, solid connections from main bus bar to switch gears with required size of bus bars and control wiring with min 1.5 sqmm PVC insulated copper conductor cable, cable alleys, cable gland plates in two half including digital multifunctional display meter, phase indication lamp & its connection with following controls:-
Incoming:-
One Number MCCB, 160 A, 4 Pole, 16 KA (Ics= Icu), 415V, thermally adjustable between 70 to 100%. Make - Legrand cat ref No. 420017 or equivalent in Schneider or ABB.
Outgoing:-
(a) One number MCCB, 63 A, 4 Pole, 16 KA (Ics= Icu) thermally adjustable between 70 to 100%. Make - Legrand cat ref No. 420013 or equivalent in Schneider or ABB.
(b) Two Numbers MCCB 40 A, 4 Pole, 16 KA (Ics=Icu) thermally adjustable between 70 to 100%. Make - Legrand cat ref No. 420012 or equivalent in Schneider or ABB.
(c) One MCB double pole, 16 A, 10 KA, C series ISI marked. Make - Legrand cat ref No. 408633 or equivalent in Schneider or ABB.
(d) Timer one output 16 A, 240 volts Astronomical type. Make - Legrand cat ref No. 412654 or equivalent in Schneider Acti 9 or ABB.
Material and labour for hot dip galvanised iron octagonal pole of height 9 mtrs minimum galavnising of 100 microns, top 70 mm, bottom 130 mm and 3 mm sheet thickness in single section without any weld joints with square plate of minimum dimensions 225 x 225 x 12 mm foundation bolts, single arm GI bracket of 1.0 m for mounting the street light fitting, bakelite sheet with one MCB SP 6 A, and 16 mm stud type connectors - 04 Nos inside the pole at the door opening for cable connections with foundation bolt of size M24 x 700 mm including necessary earth work, PCC foundation as required. Note - Pole shaft shall be as per BSEN 10025, IS 5986, ASTM A572. Foundation as per manufacturers instructions.
Supply and fix set of 4 Nos. 9.5 litre GI bucket painted in post office red colour with primer coat of red oxide paint and written with white paint 'FIRE' and mounted on MS angle iron frame over roof sheet with bracket of appropriate size & capacity including filling of sand as required.
Supply and fix carbon dioxide (CO2) type fire extinguishers confirming to IS 2878-1976 and cylinders fully charged of capacity 4.5 Kg complete.
Supply and fix foam fire extinguishers, portable type 9 litre capacity hanged on wall with bracket complete as required.
Supply and fix ABC powder fire extinguisher Mono Ammonium Phosphate (MAP 90 based portable stored pressure) of following capacities:-
Supply and fix First Aid Box with kit as approved by St. John Ambulance Brigade/Indian Red Cross conforming to IS - 2217 : 1963 complete.
Supply and fix Safety instruction chart in word duly framed with 5 mm thick glass (Approximate front area 1.20 sqm) as required
Supply and fix Shock treatment chart duly mounted on a wooden frame with 5 mm thick glass (Approximate front area 1.20 sqm) as required.
Material and labour for point wiring with 1100 volts grade PVC insulated FRLS multistranded copper conductor cable 1.5 sqmm and earth continuity conductor with 1.5 sqmm using colour code drawn into and including concealed rigid non metallic PVC conduit medium grade not less than 25 mm dia ISI marked ivory colour with all conduit fittings / fixing accessories and sunken modular GI metal boxes 1.0 mm thick and modular mounting cover plates with frame of approved colour for mounting modular switches, sockets, fan regulators etc as required for the following:-
One light point or one fan point controlled by one switch.
One socket outlet 6 amp controlled by one switch on the same board with other switches.
One socket outlet 6 amp controlled by one switch on independent board.
Material and labour for point wiring with 1100 volts grade PVC insulated FRLS multistranded copper conductor cable 4.0 sqmm and earth continuity conductor 4.0 sqmm using colour code drawn into and including concealed rigid non metallic PVC conduit medium grade not less than 25 mm dia ISI marked ivory colour with all conduit fittings / fixing accessories and sunken modular GI metal boxes 1.0 mm thick and modular mounting plates with frame of approved colour for mounting modular switches, sockets as required for 3 pin 16 amps socket outlet point controlled by one switch.
Supply and fix modular switch one way 6 amp 1 module.
Supply and fix modular switch one way 16 amp 1 module.
Supply and fix modular socket 6/16 - 2/3 pin combined 2 module .
Supply and fix modular socket 6 amp 2/3 pin combined 2 module.
Supply and fix ceiling rose 3 plates polycarbonate body complete.
Supply and fix MCBs of 'C' series having breaking capacity 10 KA, ISI marked including required wiring connections with copper lugs of suitable size provided in MCB DBs, single pole MCB 6A to 25A, 240V as required.
Supply and fix LED security light fixture 35 watt powder coated pressure die cast aluminum body with driver Input voltage: 140-270 Volt AC, freq 50 Hz, Operating temp range -15 deg to 50 deg centigrade, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2 , P. F.≥0.95, IP- 66,IK-10, CRI >80, under voltage and over voltage protection, EMIEMC as per CISPR -15, lenses for beam angle as per IESNA type I/II/III as per the requirement, life time (LED, Driver & electrical circuitry) of minimum 50000 burning hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 5700°K /6000°K/6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect including connections with suitable size FRLS, PVC insulated copper conductor cable and earthing et. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output. LM79 & LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminum housing such that LED junction temperature shall not rise above 90°C)
Supply and fix MCCB four pole, 160 amps, 16 KA thermally adjustable between 70 to 100% including 4 spreader link set of same make as that of MCCB for connection, required lugs as required.
Supply and fix rigid non-metallic PVC conduit exclusive of boxes (junction/terminal) but inclusive of all tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc 25 mm external dia for telephone cable and TV socket complete.
Supply and fix MCB distribution board, triple pole and neutral, powder coated CRCA steel sheet suitable for MCCB incomer up to 160 amp, 6 way, 415 volts, degree of protection IP 43 - IK- 09 with reversible double door, recess mounted, having 250 amp insulated tinned copper bus bar, neutral busbar, earth bar, din bar, detachable gland plate, interconnection, earthing connection, blanking plates in unused spaces as required
Material and labour for pipe in pipe chemical earthing with GI pipe electrode 3.0 m long having outer pipe dia 50 mm & inner pipe dia 25 mm duly filled with highly conductive and anti corrosive compound of required quantity in ground by digging a bore of 100 mm dia surrounded by soil friendly backfill compound including connection with galvanised earth wire 4 mm dia from earth electrode to the equipment to be earthed duly protected in 15 mm medium grade GI pipe up to 7.5 m, making PCC pit of size 0.3 m x 0.3 m x 0.3 m (inner size) in mix 1:3:6 type C1 with PCC 1:2:4 type B-1, CI cover with frame & locking arrangement and testing on completion to achieve value not more than 2.0 ohm complete.
Supply and fix RJ 11 socket with metal box and top plate complete.
Supply and fix TV Socket Co-Axial with metal box and top plate complete.
Supply and fix LED surface mounted batten 20 watt, powder coated die cast / extruded aluminium Body (Thickness ≥ 1.20 mm) and construction as per IS : 10322 with driver (Replaceable) as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, freq 50 Hz, Operating temp range -15 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection, THD < 10% , P. F.≥0.95, IP20, CRI >80, Flicker free, (flicker should be below 5%), life time (LED Driver & electrical circuitry), of minimum 50000 burning hours with 70% of initial Lumen maintained till life ends, CCT 5700°K /6000°K/6500°K (As per ANSI Bin), SDCM (Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and fixture shall be of relevant BIS standard and trade mark certificate (T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete in all respect including connections with suitable size FRLS, PVC insulated copper conductor cable and earthing etc as required with Minimum 5 year OEM warranty. System lumen efficacy 120 lm/Watt output. LM79 & LM80 Test report from NABL lab for all testing required for LED fixtures as BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminum housing such that LED junction temperature shall not rise above 90°C).
Supply and fix recessed mounted 12 watt round LED ceiling light SMD type with diffuser spring loaded having lumen output not less than 120 lumen/watt suitable for fixing in 3" junction boxes casted in roof slab including connection complete.
Supply and fix GI pipe bracket 25 mm dia light grade of 1.2 m long bent to shape for street light fitting with MS clamps nuts, bolts & washers including painting complete.
Supply and fix ceiling fan 1200 mm sweep, BEE star rated with brush less direct current (BLDC) motor, class of insulation: B, 3 Nos blades, up to 90 cm long down rod, canopies, shackle kit, safety rope, copper winding, power factor not less than 0.9, service value(CM/M/W) minimum 6.00, air delivery minimum 210 Cum/Min, 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max), insulation resistance more than 2 mega ohm, suitable for 230V, 50 Hz complete.
Supply and fix Fresh air fan of size 200 mm sweep PVC body complete with louvers connecting up including suitable size three core flexible copper cable from ceiling rose to exhaust fan as required.
Supply and fix Heavy duty exhaust fan of size 450 mm sweep 900 rpm metal body with louvers connecting up including suitable size three core flexible copper cable from ceiling rose to exhaust fan as required.
Sant Construction Co. (BID ID -3363343)
DURGAI ELECTRICALS (BID ID -3363690)
M/s Prem Associates (BID ID -3371037)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .