Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance OFFICE NO 206 D WING EXTENSION RAIKER CHAMBERS DEONAR VILLAGE ROAD GOVANDI EAST MUMBAI 400088 | MUMBAI | MUMBAI | MAHARASHTRA | 400088 | Admitted-Finance |
| 2 | Admitted-Finance 216 CITI TOWER SECTOR 15 CBD BELAPUR NAVI MUMBAI 400 614 | NAVI MUMBAI | THANE | MAHARASHTRA | 400614 | Admitted-Finance |
| 3 | Admitted-Finance | Admitted-Finance |
Tender Value
₹33.8 L
EMD Value
₹67,600
Closing Date
9 Jan 2023, 3:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Chief Engineer GSS
DCSEM, DAE, V.S. Bhavan, Anushaktinagar, Mumbai-400094
Providing Lighting Arrangement for Swimming pool in PTAAF complex, Tenis, kabbadi and Volleyball Court in Anushaktinagar, Mumbai
2022_DCSEM_729210_1
DCSEM/CQD/QSC/GSS/22-23/NIT-38
Open Tender
Electrical Works
Item Rate
180 days
PTAAF complex at Anushaktinagar, Mumbai
Please refer Tender Documents
8 documents required · 8 mandatory
₹0
₹67,600
3 Mar 2023
16 Dec 2022
10 Jan 2023
16 Dec 2022
9 Jan 2023
16 Dec 2022
16 Dec 2022 - 23 Dec 2022
Amount
Design, manufacture, testing at works, supply, assembling, installation, and erection of 11 mtr HDG High Mast (above ground level), top dia 100mm bottom dia 360mm pole internally & externally hot dipped galvanised, similar to M/s Bajaj cat ref BHMRL11B or equivalent, fabricated out of 3mm thick sheet as per relevant I.S, complete with Hot deep galvanized Bracket made up of MS angle / C channel/ flat suitable for installation of 6 nos LED flood light fixtures, built in junction box, base plate as per detailed specifications & drawings. Junction box should be provided 450 mm above base plate with 4 Nos brass terminals on epoxy insulator,6 no 6A SP MCB & 1 no. neutral link mounted on 4 mm thick Bakelite sheet, 2mm GI gland plate etc. Base plate should have 4 nos holes suitable for mounting on M30 RCC foundation 300 mm above FGL. The cost of pole shall include the cost of RCC foundation , foundation bolts, anchor plates, nuts, washers, min 2 nos. HDPE PLB pipe 40/33 mm dia bend to shape approx. 1.0 m in length, & including excavation in all types of soil/foot path cutting , temporary reinstatement, back filling, dewatering, consolidation, disposal of excess earth within the radius of 3000 m and making good to the original finish etc. as per enclosed detailed specifications & drawings, as required to complete the work in all respect as per instructions of the E-I-C.
Design, manufacture, testing at works, supply, assembling, installation, and erection of 9 m (above ground level ) Octagonal pole internally & externally hot dipped galvanised similar to BOP -9031 M/s Bajaj or equivalent, fabricated out of 3mm thick sheet as per relevant I.S, complete with Hot deep galvanized Bracket made up of MS angle / C channel/ flat suitable for installation of 2 nos LED flood light fixtures, built in junction box, base plate size 200 X 200 X16 mm, as per detailed specifications & drawing. Junction box should be provided 500 mm above base plate with 4 Nos brass terminals on epoxy insulator, 2 no 6A SP MCB & 1 no. neutral link mounted on 4 mm thick Bakelite sheet, 2mm GI gland plate etc. Base plate should have 4 nos holes suitable for mounting on M30 RCC foundation 200 mm above FGL. The cost of pole shall include the cost of RCC foundation , foundation bolts, anchor plates, nuts, washers, min 2 nos. HDPE PLB pipe 40/33 mm dia bend to shape approx. 1.0 m in length, & including excavation in all types of soil/foot path cutting , temporary reinstatement, back filling, dewatering, consolidation, disposal of excess earth within the radius of 3000 m and making good to the original finish etc. as per enclosed detailed specifications & drawings, as required to complete the work in all respect as per instructions of the E-I-C.
Installation, testing and commissioning of department supply ( Including transportation from DCSEM store to site ) 1.1 kV grade PVC/XLPE insulated, inner sheath PVC tapped and outer sheath extruded PVC, multi stranded aluminium conductor, GI strip armoured 4 C x 10 sq. mm aluminium conductor power cable, fixed on wall/columns/slab or in existing hume pipe/trench/G.I. sleeves/pipes or in existing trench at a depth of 900 mm below ground level excluding excavation in all types of soils/soft rock if any, sand bedding, laying of baked bricks as per IS on side and top, including consolidating, temporary reinstatement, back filling, dewatering, if necessary, disposal of excess earth within the radius of 3000 mtrs, all as per drawings, specifications, and as per instructions of E.I.C.
In ground
In existing RCC hume pipes/G.I. pipes trench/
On wall/beam/column with necessary heavy duty spacers/saddles etc.
End jointing of 4 C x 10 sq. mm aluminium conductor cable by crimping, with supply of all jointing materials like solder less heavy duty tinned copper socket, long nipple cable gland, insulation tape, flux, Suitable brass earth tag for duplicate earthing for cable gland with 8SWG GI wires interconnecting GI pole/Al. pole and as per the instructions of E.I.C.
Supply, installation, testing & commissioning of following LED luminaries having a minimum efficacy of 130 lm/watts with cool white/ neutral white colour temperature & pressure die cast Aluminium housing having IP66 protection etc. All the accessories shall be housed in side light fixture with suitable connector. Scope also includes providing interconnection with 3Cx2.5 sq. mm copper conductor PVC insulated PVC sheathed flexible cable, earthing of fixture, PVC coated Galvanized steel conduit to be provided for exposed flexible cable, etc. (Independent wiring to be done for each fixture from terminal box). Note: 1) The fixture to be got approved by department before manufacturing/supply. The fixtures shall have replacement warranty of 5 years from date of supply. Warranty certificates shall be submitted to department at the time of supply.
LED Flood light luminaire suitable for outdoor swimming pool lighting having minimum output of 46500 lumens, efficacy of 130 lm/watts, CRI 70, IP66, IK08, Surge protection 4 kV, THD ≤10%, Aluminium Die cast housing, optical lense, polycarbonate optical covers. The scope of work includes lighting design for swimming pool using software to get the following parameter at surface of the swimming pool. a) Average Lux 250 b) overall Uniformity ( Emin/Eav) : 0.5 c) Glare : <55
LED Flood light luminaire suitable for outdoor Kabaddi & Volleyball court having minimum output of 24000 lumens, efficacy of 130 lm/watts, CRI 70, IP66, IK08, Surge protection 4 kV, THD ≤10%, Aluminium Die cast housing, optical lense, polycarbonate optical cover. The scope of work includes lighting design for outdoor Kabaddi & Volleyball court using software to get the following parameter at surface of the swimming pool. a) Average Lux 250 b) overall Uniformity ( Emin/Eav) : 0.5 c) Glare : <55
LED Flood light luminaire suitable for outdoor tenis court having minimum output of 37500 lumens, efficacy of 130 lm/watts, CRI 70, IP66, IK08, Surge protection 4 kV, THD ≤10%, Aluminium Die cast housing, optical lense, polycarbonate optical cover. The scope of work includes lighting design for outdoor tenis court using software to get the following parameter at surface of the swimming pool. a) Average Lux ____ b) overall Uniformity ( Emin/Eav) : 0.5 c) Glare : <55
Earth Station: Providing earth station with heavy dipped GI earth plates electrode 600 x 600 x 6.0 mm in size at the depth minimum of 2.5 m below ground level (bottom of Plate) confirming to IS 3043 complete with all required materials like coke / charcoal, salt, G.I nut bolts, washers, 19 mm dia GI pipe (B class), 150 mm thick concrete wall chamber duly plastered having size of 500 x 500 x 500 mm, heavy duty (minimum 6 mm thick) M.S chequered plate cover, associated materials like 40 x 40 x 5 mm angle iron frame work, hinged locking arrangements, complete with funnels, GI test links (50 x 6 mm), two runs of 25 x 6mm G.I strips for connecting G.I plate & test link etc. including excavation of ground in all types of soils, refilling & removal of excess earth within a radius of 3000 m etc. all as required as per the drawings, specifications & instructed by Engineer-in-charge. Note:- 1. The chamber cover & frame shall be got approved by Department & painted with two coats of red oxide & one coat of enamel paint. 2. Painting of earth value & test date on cover plate. 3. All earthing stations in one building shall be interconnected to each other . 4. Earthing strips shall be welded with the earthing plate before galvanizing & two holes on each strip & plate shall be made for fixing the screws.
Earthing strips: Supply, installation, testing & commissioning of 25mmx 3 mm hot dipped strip in ground excluding excavation in all type of soil, interconnection of earth strip & continuous welding the joints in all four contact ages, painting the joint with black bituminous compound, painting with two coats of black bituminous compound for earth strip in ground etc. all as required & instructed by the E-I-C. Excavation will be paid separately.
6 ways VTPN DB: Supply, installation, testing & commissioning of readymade double door 6 ways VTPN DB having IP43 similar to model No.:507726 of M/s Legrand with ready made cable end box, supply, installation ,testing & commissioning of following equipment i.)32A TP C-curve MCB, 10kA BC.- 5 nos. ii.) 40-63A TP MCB -1 no. iii.)63A, 30mA FP RCB0 - 1nos Note : Danger board, SLD shall be provided.
Earth excavation in hard rock/soft rock & breaking the existing drain walls & reinstatement
Excavating of soft soil including shorting or dewatering, removing of bricks/tiles etc. refilling and consolidation of the surface. Disposing the excess earth within a 3000 meter radius as directed by engineer-in- charge.
Cutting of asphalt road / concrete flooring /drain of 200 mm depth by using hydraulic drilling machine as required and stacking of rocks, refilling and consolidation of the surface. Disposing the excess earth within a 3000 meter radius as directed by engineer-in-charge
Excavating in hard rock including shorting or dewatering, removing of bricks/tiles etc. refilling and consolidation of the surface. Disposing the excess earth within a 3000 meter radius as directed by engineer-in- charge.
Providing Plain cement concrete 1:3:6 using graded stone aggregate of 20 mm maximum size including consolidation, stacking, soling, frame work, shuttering, finishing, curing etc. Complete all as directed by Engineer in charge. Complete all as per specification & as directed by EIC.
Removing and relaying of old Shahabad stone/ paver blocks (60/ 80 mm thick) with care with out causing any damages to adjacent footpath and paved area etc. , stacking properly the serviceable materials and disposal of unserviceable materials within 150 m lead all as per specification and as per direction of Engineer-in-charge.
Supply & installation of 50mm dia. HDPE pipe with all fixing accessories in ground at a depth of 500 mm below ground level excluding excavation in all types of soils, including consolidating, temporary reinstatement, back filling, dewatering, all as required & as instructed by EIC.
Arathi Electricals
PRANIT PROCONCO
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .