| Sl No | Description | Qty | Unit | Devraj Enterprises L2 | Raj Engineering Co. L1 |
|---|---|---|---|---|---|
| 1.01 | Supply / Fabrication of L T Panel Board cubical type, floor mounting, dust & vermin preventing construction, of the minimum size 1200 X 1200 X 350 mm, suitable for indoor fixing, made out of 16 SWG CRCA sheet, with provisions for cable entry from bottom and having chambers as described below. The panel should have separate cable alleys and bus bar alleys. It should be suitable for operation and maintenance from the front and having removable covers at the back and having doors complete with locks etc. at the front for each chamber. The rating of main bus bars has to be 400 Ampere for three phases and half for the neutral in Aluminium construction duly sleeved with phase indicating heat shrinkable Sleeves. It should painted through powder coating process and with complete provisions suitable for all the switchgears as below to be fitted / installed properly with complete mounting accessories as per requirement with complete internal connections of switchgears and control gears with the main bus bars in the Panel through copper cable or bus bars along with making all the required wiring connections for all measuring and indicating instruments with all the accessories, thimbles, ferrules etc. complete in all respect as per requirement. The Panel should have chambers and insertions as per following details. Make for following Switchgeras- L&T/Schneider/BCH/C&S/DJB approved. Make for following metering instruments -L&T/Schneider/AE/DJB approved.One Incomer Chamber havingfollowinginsertions-Moulded Case Circuit Breaker (MCCB) of rating 400 Amp, four Pole, 415V, AC of breaking capacity of 36 KA or more - 01 No.. One Metering Chamber for the Incomer having following insertions-Ampere Meter 96X96 mm Digital type - 01 No. Volt Meter 96X96mm Digital type. -01 No.Ampere Meter selector switch. - 01 No.Volt meter selector switch. - 01 No.Indicating Lamp, Led type for Three Phases -03 Nos.MCB, 6 Amp, SP, ‘C’ Curve. - 03 Nos.Current Transformer 200/5 ampere. - 03 Nos.Two Outgoing Chambers with each having following insertions-MCCB of rating 250 Amp, 3 Pole, 25KA, 415V, AC.- 01No.Contactor 200 A, TP, 415V AC -2 Nos.Contactor 250 A, TP, 415V AC-1 No.
Timer for starter -1 No.Add on block 1 No + 1 NC -2 Nos. Overload Relay for 60 HP -01 No.Voltage unbalance Relay -01 No.Push Buttons with contact Block for On/Off -02 Nos.
Ampere Meter Digital type. -01 No.Volt Meter Digital type. -01 No.Ampere Meter selector switch. -01 No.Volt meter selector switch. -01 No.Indicating Lamp, Led type for phase indication -03 Nos.Indicating Lamp, Led type for On/Off -02 Nos.MCB, 6 Amp, SP, ‘C’ Curve. -03 Nos.Current Transformer 100/5 ampere. -03 Nos.One Outgoing Chambers with each having following insertions-Moulded Case Circuit Breaker (MCCB) of rating 63 Amp, Triple Pole, 415V, AC of breaking capacity of 25 KA or more - 01 No.. Contactor TP 32 Amperes -01 No.Over Load Relay for 5 HP - 01 No.Add On Block 1NO 1NC - 01 No.Single Phase Preventor - 01No.Ampere Meter 96X96 mm Digital type - 01 No. Indicating Lamp, Led type -05 Nos.MCB, 6 Amp, SP, ‘C’ Curve. - 03 Nos. | 1 | Nos. | 2,70,000 ₹3,18,600 | 2,59,000 ₹3,05,620 Lowest |
Tender Value
Refer Docs
EMD Value
₹6,300
Closing Date
10 Sept 2026, 3:15 pmClosed
EE ENM M 4
DELHI JAL BOARD C-Block Near Divya Jyoti Apartment, Sector-19 BPS Rohini, Delhi-89
Fabrication of LT Panel Board for SPS near Jharoda metro Station Wazirabad Timarpur AC 03
2026_DJB_297893_39
NIT No. 10(2026-27)M-4
Open Tender
Miscellaneous Works
Item Rate
30 days
EE ENM M 4
Please refer Tender documents.
3 documents required · 3 mandatory
₹500
Account No 50448339804
₹6,300
Yes
24 Sept 2026
3 Sept 2026
10 Sept 2026
3 Sept 2026
10 Sept 2026
3 Sept 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1.01 | Supply / Fabrication of L T Panel Board cubical type, floor mounting, dust & vermin preventing construction, of the minimum size 1200 X 1200 X 350 mm, suitable for indoor fixing, made out of 16 SWG CRCA sheet, with provisions for cable entry from bottom and having chambers as described below. The panel should have separate cable alleys and bus bar alleys. It should be suitable for operation and maintenance from the front and having removable covers at the back and having doors complete with locks etc. at the front for each chamber. The rating of main bus bars has to be 400 Ampere for three phases and half for the neutral in Aluminium construction duly sleeved with phase indicating heat shrinkable Sleeves. It should painted through powder coating process and with complete provisions suitable for all the switchgears as below to be fitted / installed properly with complete mounting accessories as per requirement with complete internal connections of switchgears and control gears with the main bus bars in the Panel through copper cable or bus bars along with making all the required wiring connections for all measuring and indicating instruments with all the accessories, thimbles, ferrules etc. complete in all respect as per requirement. The Panel should have chambers and insertions as per following details. Make for following Switchgeras- L&T/Schneider/BCH/C&S/DJB approved. Make for following metering instruments -L&T/Schneider/AE/DJB approved.One Incomer Chamber havingfollowinginsertions-Moulded Case Circuit Breaker (MCCB) of rating 400 Amp, four Pole, 415V, AC of breaking capacity of 36 KA or more - 01 No.. One Metering Chamber for the Incomer having following insertions-Ampere Meter 96X96 mm Digital type - 01 No. Volt Meter 96X96mm Digital type. -01 No.Ampere Meter selector switch. - 01 No.Volt meter selector switch. - 01 No.Indicating Lamp, Led type for Three Phases -03 Nos.MCB, 6 Amp, SP, ‘C’ Curve. - 03 Nos.Current Transformer 200/5 ampere. - 03 Nos.Two Outgoing Chambers with each having following insertions-MCCB of rating 250 Amp, 3 Pole, 25KA, 415V, AC.- 01No.Contactor 200 A, TP, 415V AC -2 Nos.Contactor 250 A, TP, 415V AC-1 No.
Timer for starter -1 No.Add on block 1 No + 1 NC -2 Nos. Overload Relay for 60 HP -01 No.Voltage unbalance Relay -01 No.Push Buttons with contact Block for On/Off -02 Nos.
Ampere Meter Digital type. -01 No.Volt Meter Digital type. -01 No.Ampere Meter selector switch. -01 No.Volt meter selector switch. -01 No.Indicating Lamp, Led type for phase indication -03 Nos.Indicating Lamp, Led type for On/Off -02 Nos.MCB, 6 Amp, SP, ‘C’ Curve. -03 Nos.Current Transformer 100/5 ampere. -03 Nos.One Outgoing Chambers with each having following insertions-Moulded Case Circuit Breaker (MCCB) of rating 63 Amp, Triple Pole, 415V, AC of breaking capacity of 25 KA or more - 01 No.. Contactor TP 32 Amperes -01 No.Over Load Relay for 5 HP - 01 No.Add On Block 1NO 1NC - 01 No.Single Phase Preventor - 01No.Ampere Meter 96X96 mm Digital type - 01 No. Indicating Lamp, Led type -05 Nos.MCB, 6 Amp, SP, ‘C’ Curve. - 03 Nos. | 1 | Nos. | 80 | ₹80 |
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.75 MB
BOQ_397067.xls
BOQ • 0.26 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .