Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹26.7 LAccepted-AOC | L1 | Accepted-AOC ACCEPTED | |
| 2 | L2₹29.1 L+₹2.2 L (8.10%)Rejected-Finance | L2 | Rejected-Finance 2ND LOWEST | |
| 3 | L3₹29.3 L+₹2.3 L (8.71%)Rejected-Finance | L3 | Rejected-Finance 3RD LOWEST | |
| 4 | L4₹32.4 L+₹5.4 L (20.1%)Rejected-AOC | L4 | Rejected-AOC REJECTED | |
| 5 | L5₹32.6 L+₹5.6 L (21.0%)Rejected-Finance | L5 | Rejected-Finance 5TH LOWEST |
Tender Value
Refer Docs
EMD Value
₹54,000
Closing Date
10 Nov 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
R S SHUKLA EE
GARRISON ENGINEER I GOPALPUR MILITARY STATION PO GOLABANDHA DIST GANJAM ODISHA 761052
REPAIR REPLACEMENT OF APFC PANELS AND ALLIED WORKS AT GMS
2020_MES_388562_1
8000/62/20-21/0963/E8
Open Tender
Civil Works
Item Rate
270 days
GOPALPUR MILITARY STATION
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
Yes
GARRISON ENGINEER I GOS
₹54,000
Yes
27 Nov 2020
21 Oct 2020
12 Nov 2020
21 Oct 2020
10 Nov 2020
4 Nov 2020
60 days
Amount
(b) 70 KVAR to 125 KVAR
S&F in replacement of power capacitor box type of the following capacities :- (a) 3 KVAR box type heavy duty capacitor 440V Make:- L&T / HAVELLS/ ABB / SIEMENS
(b) 5 KVAR box type heavy duty capacitor 440V Make:- L&T / HAVELLS/ ABB / SIEMENS
(c) 10 KVAR box type heavy duty capacitor 440V Make:- L&T / HAVELLS/ ABB / SIEMENS
(d) 15 KVAR box type heavy duty capacitor 440V Make:- L&T / HAVELLS/ ABB / SIEMENS
(e) 20 KVAR box type heavy duty capacitor 440V Make:- L&T / HAVELLS/ ABB / SIEMENS
(f) 25 KVAR box type heavy duty capacitor 440V Make:- L&T / HAVELLS/ ABB / SIEMENS
Supply and fix Contactors capacitor duty rating 3 phase 415 V suitable for 3 KVAR Make:- L&T / HAVELLS/ ABB / SIEMENS
Supply and fix Contactors capacitor duty rating 3 phase 415 V suitable for 5 KVAR Make:- L&T / HAVELLS/ ABB / SIEMENS
Supply and fix Contactors capacitor duty rating 3 phase 415 V suitable for 10 KVAR Make:- L&T / HAVELLS/ ABB / SIEMENS
Supply and fix Contactors capacitor duty rating 3 phase 415 V suitable for 15 KVAR Make:- L&T / HAVELLS/ ABB / SIEMENS
Supply and fix Contactors capacitor duty rating 3 phase 415 V suitable for 20 KVAR Make:- L&T / HAVELLS/ ABB / SIEMENS
Supply and fix Contactors capacitor duty rating 3 phase 415 V suitable for 25 KVAR Make:- L&T / HAVELLS/ ABB / SIEMENS
Supply and fix timer 5 A 0 - 60 seconds 230 V Make:- L&T / HAVELLS/ ABB / SIEMENS
Supply and fix display/relay unit computerised control of Power Factor Digital type 4 steps 440 V Make:- L&T / HAVELLS/ ABB / SIEMENS
Supply and fix display/relay unit computerised control of Power Factor Digital type 8 steps 440 V Make:- L&T / HAVELLS/ ABB / SIEMENS
Supply and fix display/relay unit computerised control of Power Factor Digital type 12 steps 440 V Make:- L&T / HAVELLS/ ABB / SIEMENS
Supply and fix LED Indicator 20mm dia replaced by old indicator Make:- L&T / HAVELLS/ ABB / SIEMENS
Supply and fix LED Indicator 15mm dia replaced by old indicator Make:- L&T / HAVELLS/ ABB / SIEMENS
Supply & Fix MCB 4 pole 63A .10 KA 415 V incl taking down old U/S MCB Make:- L&T / HAVELLS/ ABB / SIEMENS
Supply & Fix switch fuse unit TPN 500 Volts 3 phase with HRC fuses suitable for interior mounting in panel capacity of 63 Amps each incl taking down old U/S switch. Make:- L&T / HAVELLS/ ABB / SIEMENS
Supply & Fix MCCB 3/4 POLE 100 A 16 KA 415 V incl taking down old U/S MCCB Make:- L&T / HAVELLS/ ABB / SIEMENS
All as per item no 18 above but 200 Amps 4 pole 36KA, 415 V Make:- L&T / HAVELLS/ ABB / SIEMENS
Supply, Installation & commissioning of APFC panel 55 KVAR outdoor floor mounting type busbar capacity 25x8 alumimum Bus bar 3 and 1/2 bar DMC Insulator with busbar supporter body 3.15mm CR sheet colour totally powder coated with siemens grey box type capacitor following in 05/06/08 steps including PCC work complete all as specified and directed. . make of panel CPRI approved make of switch gear : L&T ,ABB, Siemens, HAVELLS Incoming (i) 160 Amps MCCB 4 Pole 35 KA - 1 No. Outgoing (i) 5 KVAR box type - 2 No (ii) 10 KVAR box type - 1 No (iii) 15 KVAR box type - 1 No (iv) 20 KVAR box type - 1 No
Supply, Installation & commissioning of APFC panel 75 KVAR indoor floor mounting type busbar capacity 25x8 alumimum Bus bar 3 and 1/2 bar DMC Insulator with busbar supporter body 3.15mm CR sheet colour totally powder coated with siemens grey box type capacitor following in 05/06/08 steps including PCC work complete all as specified and directed. . make of panel CPRI approved make of switch gear : L&T ,ABB, Siemens, HAVELLS Incoming (i) 200 Amps MCCB 4 Pole 35 KA - 1 No. Outgoing (i) 5 KVAR box type - 2 No (ii) 10 KVAR box type - 3 No (iii) 15 KVAR box type - 1 No (iv) 20 KVAR box type - 1 No
Earthing complete with galvanized steel earth plate electrode 60cm x 60cm x 6mm thick buried directly in ground (earth pit not less than 2.25 mtrs deep below ground level) with top edge of the earth plate at a depth of not less than 1.5 mtr below ground level connected to galvanized iron strip 25 x 4 mm as earthing lead by means of bolts, nuts and washers made out of GI/steel earth strip protected by GI light grade pipe of 40 mm dia and connecting to main panel board/switch board/control board all shown in electrical plate No 3 of SSR Pt I incl PCC chambers in 1:2:4 and RCC cover slab with 8mm dia MS bars reinforced at 10 cm center to center both ways incl earth work like excavation, returning filling back disposal etc complete all as specified and directed.
Checking of street/security lights breakdown maint of overhead lines/9/11 mtr pole/swan neck poles by checking out the cables/carbon removal / connectors / mcbs etc and locating the fault and replacing with necessary cables for jumpers/ clamps & connectors/terminal box etc, making good, cleaning and lubricating the parts etc complete all as specified and directed. Note 1: quoted rate inclusive of vehicle with ladder and manpower job card received from power house and after completion of work job card return to power house . Note 2 Drivers/PCBs/cables/fittings/terminal box/ disc/pin insulators, are measured and paid separately under relavent items
Supply and fix in replacement of Driver for 45W LED fittings complete all as specifed and directed. Make : C&S / Havells/ HPL/ Sysca
Supply and fix in replacement of Driver for 20/25W LED fittings complete all as specifed and directed. Make : C&S / Havells/ HPL/ Sysca
Supply and fix in replacement of PCB for 45watts street light fittings with lens complete all as specified and directed. Make : C&S / Havells/ HPL/ Sysca
Supply and fix in replacement of MCPCB for 20/25 watts street light fittings with lens complete all as specified and directed. Make : C&S / Havells/ HPL/ Sysca
Supply and fix in replacement of Timer panel, made of MS Enclosure factory made consisting digital timer 24 hour set up with contactor rating65 Amps TP of max load 12 KW complete with fixing arrangemetns on MS Channel of suitable size and necessary PCC Wk complete all as specified and directed. Make: HAVELLS/C & S / L & T/ INDO ASIAN
M&L for taking down the motorised / manual High Mast Lights circular grid accomodating MH/MV light fittings any cap over a ht of 15 mtr to the ground, taking aside, replacing the unsv control gears/ light fittings with LED fixtures and raising back to its original position upto 15 mtr etc complete all as specified and directed (Rates quoted shall be incl of replacing required accessories where specifically not mentioned but required to complete the Job except LED fixtures)
S & F in replacement of direct type LED retrofit lamp in street light fittings 30 watt 2500 lumen output, 6500 K colour temp complete all as specified and directed. Make : C&S / Havells/ HPL/ Sysca
S&F in replacement Digital/Anologue electro mechanical timer 24 hrs minimum setting 30 minutes for daily working contact rating 16 Amps, 240 Volts, AC with initial charging, battery backup having supply reserve failure etc complete all as specified and directed. Make : C&S / Havells/ HPL/ Sysca/ L & T
Supply and fix in replacement of automatic modular contactor with manual override , 40 Amps 1P 50HZ suitable for timer switch of street light complete all as specified and directed Make : C&S / Havells/ HPL/ Sysca/ L & T
Supply and fixing in replacement MCCB adjustable / fixed thermal type 3/ 4 pole 415 volts of capacity 250 amps including disconnection of LT line suppy ,extraction of loop & refixing with proper lugs all as per existing requirement on site 36 KA complete all as specified and directed. Make Standard/ Havells/ L & T / MDS/Legrand/HPL
Supply and fixing in replacement MCCB adjustable / fixed thermal type 3/ 4 pole 415 volts of capacity 160-200 amps including disconnection of LT line suppy ,extraction of loop & refixing with proper lugs all as per existing requirement on site 36 KA complete all as specified and directed. Make Standard/ Havells/ L & T / MDS/Legrand/HPL
Supply and fixing in replacement On load change-over switch I-O-II patern 4 pole 415 volts of capacity 200 amps including disconnection of LT line suppy ,extraction of loop & refixing with proper lugs all as per existing requirement on site open execution type to suit the existing withing the panel with extended lugs complete all as specified and directed. Make Standard/ Havells/ Indo-asian/Legrand/HPL
Supply and fixing in replacement On load change-over switch I-O-II patern 4 pole 415 volts of capacity 250 amps including disconnection of LT line suppy ,extraction of loop & refixing with proper lugs all as per existing requirement on site open execution type to suit the existing withing the panel with extended lugs complete all as specified and directed. Make Standard/ Havells/ Indo-asian/Legrand/HPL
Supply and fix street light fitting LED type of 45 watt New generation energy saving & environmental friendly long life versatile pressure die-cast aluminium IP66 roadway luminaire with high power LEDs as light source and electronic dirver complete all as specified and directed.
Supply and fix in replacement of security light fitting LED type of 20 watt New generation energy saving & environmental friendly long life Versatile pressure die-cast aluminium IP66 luminaire with high power LEDs as light source and electronic driver. complete all as specified and directed. Make C&S /WIPRO/ CG / Phillips / Havells (Note : must for warrenty of 3 yrs to 5 yrs)
Supply and fix post-top lantern 15 watt ruby clear energy saving, environmental friendly, long life aesthetically designed with IP 65 symmetrical light distribution, spun aluminium landscape luminaire with high power LEDs as light source etc complete all as specified and directed. make : Havells Cat part no RUBYMINIPT15WLED757PSYMTOPC /Bajaj /CG /philips
M&L in replacement of LED flood lights of cap 120 W cap D-clamp fitting of powder coatedpressure die cast aluminium High power LED with heat resistant toughed glass with connected accessories complete all as specifed and directed. (Make syska/hPL/Havells/C&S)
S & Fix in replacement of flat /round 3 core copper conductor PVC insulated & PVC Sheathed cable , 1100V grade complete all as specified and directed. (Make : Havells/RR KABEL/HPL/Anchor)
Supply & fix PVC conduit pipe 20mm dia with fixing arrangement with flat iron with nut bolts on pole complete all as specified and directed.
M/S. KISHAN ENGINEERING
M/s Bapujee Builders and Traders
M/s TECH TEAM
MM ENGINEERING SYSTEMS
S J ENTERPRISES
R K Traders
M/s MAA BHAIRABI ENTERPRISES
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .