Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹7.3 LAccepted-AOC | ₹7.3 L | L1 | Accepted-AOC Lowest price |
| 2 | L2₹9.4 L+₹2.1 L (28.6%)Rejected-Finance H NO 787 22 JHANG COLONY ROHTAK 124001 | ROHTAK | HARYANA | 124001 | ₹9.4 L+₹2.1 L (28.6%) | L2 | Rejected-Finance High Price |
Tender Value
Refer Docs
EMD Value
₹13,500
Closing Date
10 Feb 2021, 5:00 pmClosed
Director
Maharaja Agrasen Medical College Agroha (Hisar)
Replacement of LT Panel and Cables of Electrical Niche near Lift in OPD Building at MAMC Agroha
2021_HRY_157303_1
Tender/2021/LT Panel Cable
Open Tender
Electrical Works
Works
45 days
Maharaja Agrasen Medical College Agroha (Hisar)
Please refer Tender documents.
2 documents required · 2 mandatory
₹1,000
Yes
₹13,500
Yes
23 Feb 2021
23 Jan 2021
11 Feb 2021
23 Jan 2021
10 Feb 2021
23 Jan 2021
Amount
HSR 31.12 ( C ) Moulded case Circuit breakers. Supply and erection of moulded case circuit breaker on wall or on exiting pedestal including bonding to earth and necessary connections. (ii)100 amp. To 220 amp. 415 v,25 KA 3 -phase.
HSR 31.12 (iv) 300 amp. To 400amp. 415 v,35 KA 3 -phase.
HSR 31.12 (v)500amp. To 600amp. 415 v,35 KA 3 -phase.
(HSR 31.21)xxx Supply and erection of PVC pipe of 6 kg. Pressure, laid 1 metre below ground level complete, including digging refilling of the trench with jointing etc:- (a) PVC pipe 120 mm dia
(HSR 31.21)xxx (b) PVC pipe 80 mm dia
(Q) Earthing (HSR 31.22)iii Earthing with GI earth plate 600 mm x 600 mm x 6 mm thick including accessories and providing masonry enclosures with cover plate having locking arrangement and watering pipe etc. (but without charcoal or coke and salt) complete as required
(HSR 31.22)(v) Extra for charcoal or coke and salt for G.I plate or copper plate earth electrode.
(HSR 31.22)(xi) P/F 25mm x 5mm GI strip in 40 mm dia GI pipe from earth electrode as required
(HSR 31.22)(xv) P/F 25mm x5 mm GI strip on surface or in recess for connections etc as required wilth all labour and materials
(HSR 31.25) Supply and erection of under ground cable 1 metre below ground level covered with sand and bricks including necessary connections, digging and refilling of trenches:- (xxviii) 70 sqmm 3.5 core cable (Armoured)
(HSR 31.25) (xxx) 120sqmm 3.5 core cable (Armoured)
(HSR 31.25) (xxxiv)300 sqmm 3.5 core cable (Armoured)
(HSR 31.26) S/E of under ground cable,loose in existing pipe or trenches complete with necessary connections:- (xxviii) 70 Sq. mm 3.5 core Ard Cable
(HSR 31.26) (xxx) 120 Sq. mm 3.5 core Ard Cable
(HSR 31.26) (xxxiv)300 Sq. mm 3.5 Core Ard Cable
(HSR 31.28) Supply and erection of suitable compression type brass cable glands for underground cable:- (iv) 70 sqmm to 95 sqmm cable 3 to 3.5 core
(HSR 31.28) (v) 120Sqmm to 185 sqmm Cable 3 to 3.5 Core
(HSR 31.28) (vii) 300 Sqmm to 400 sqmm Cable 3 to 3.5 Core
(HSR 31.35)(ix) S/E of Aluminium lugs heavy duty incuding crimping etc. upto the entire satisfaction of the Engineer-in -charge of the work (g) 50 sqmm
(HSR 31.35)(ix) (h) 70 sqmm
(HSR 31.35)(ix) (j) 120 sqmm
(HSR 31.35)(ix)(k) 150 sqmm
(HSR 31.35)(ix) (n) 300 sqmm
HSR 31.35 (xi) Supply and erection of cable route marker made of 50 cm long 10mm dia M.S. rod welded/revitted at the top with 10cm dia 5mm thick GI plate inscribed with cable word on it, having a cross arm 30cm long of the same dia welded at the bottom, in exsisting trench 45 cm below ground level.
(HSR 31.48) S/E of MS saddles and clamps on wall /RCC parapit for fixing underground cable a distance of 0.60 mtr. Centre to centre fixed by means of rawl plug including the cost of all labour and materials required complete the job in all respect.
(HSR 31.74) Supply,erection of heavy duty 4 pole on laod changeover load breaker switch comprising of switches 63 amp to 400 amp. suitable for operation on 415 volt 50hz AC supply complete with handle assembly having door interlock and padlocking arrangeemt on existing panel including making necessary connections with petty materails required to complete the job. (ii) 100 amp. 4 pole ON Load changeover switch
(HSR 31.74) (iii) 200 amp. 4 pole ON Load changeover switch
(HSR 11.2) First class brick work laid in cement sand mortar 1:6 in foundation and plinth
N.S. (LT panel ) Supply , erectiion ,testing and commissioning of cubical tybe L.T. panel outdoor(double door) dust and vemins proof free standing floor mounting made out of 2MM thick CRCA sheet with 75mmx40mmx6mm chanel iron base frame painted with stove enamelled power coated paint suitable for operation on 3 phase 4 wires 50Hz A.C. supply having ammeter and voltmeter and indicating lamp. Excluding the cost of MCCB's but including the cost of items as per Anx.A Sr. No. 29
Janta Electric Store
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .