Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹29.8 LAccepted-Finance | L1 | Accepted-Finance L1 | |
| 2 | L2₹31.2 L+₹1.4 L (4.81%)Accepted-Finance 90 MYLAPORE CHENNAI TAMIL NADU 600004 | CHENNAI | TAMIL NADU | 600004 | L2 | Accepted-Finance L2 | |
| 3 | L3₹34.9 L+₹5.1 L (17.2%)Accepted-Finance | L3 | Accepted-Finance L3 | |
| 4 | L4₹42.0 L+₹12.2 L (41.1%)Accepted-Finance 7 ANIL ROY ROAD KOLKATA 700029 | KOLKATA | KOLKATA | WEST BENGAL | 700029 | L4 | Accepted-Finance L4 | |
| 5 | Not Admitted-Fee/PreQual/Technical COIMBATORE COIMBATORE TAMIL NADU | - | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
Tender Value
Refer Docs
EMD Value
₹78,720
Closing Date
19 Aug 2020, 3:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Executive Engineer (Electrical), IIT Madras
Executive Engineer (Electrical), Engg Unit, Admin Block 3rd Floor, IIT Madras, Chennai-600036
Provision of AHUs and extension of chilled water lines to terrace of Campus Cafe for Multi purpose Hall in IIT Madras
2020_IITM_54467_1
08/2020-21/ELDB
Open Tender
Electrical Works
Item Rate
90 days
IIT MADRAS CHENNAI
As per tender specified
2 documents required · 2 mandatory
₹0
₹78,720
G-MEET
20 Oct 2020
5 Aug 2020
20 Aug 2020
6 Aug 2020
19 Aug 2020
14 Aug 2020
6 Aug 2020 - 6 Aug 2020
12 Aug 2020
90 days
Amount
Equipments
Double Skinned Floor mounted Air Handling Units
Supply,installation,testing & commissioning of factory fabricated Double Skin Chilled Water Floor Mounted verticle/horizontal AHU suitable for EC motor complete with control module EC motor controllers with IO points as per requirement with RS 485 , fabricated out of extruded aluminium section with 0.8mm pre-coated galvanised steel sheet outside and 0.8 mm plain galvanised steel sheet inside with blower, blower shall be Plug Type IP55 protection with class F insulation of efficiency class IE3 suitable for operation on 415 volts ± 10%, 50 Hz ± 5% AC supply, 6 Row chilled water cooling coil (hydrophilic coated plain tube) with copper header made of Aluminium finned Copper tube with coil section with SS end plates, pre-filter section of 10 micron particle size with an efficiency of 90%, polished stainless steel drain pan made out of 18 G sheet etc
The AHU panels shall be insulated with 40mm thick & min 38 Kg/m³ density PU foam.The complete AHU shall conform to standard technical specification. The face velocity across cooling coil shall be limited to 500FPM maximum and minimum of 35 mm external static pressure shall be considered.( 1 set of commissioning filters shall be supplied along with AHU)
TR (Actual) Air Volume CFM
40 TR 16000 CFM
VENTILATION SYSTEM -FRESH AIR & EXHAUST
Circular / Rectangular Inline fans with 15mm SP of following capacity
Chilled Water Piping
Supplying, laying/ fixing, testing and commissioning of following nominal sizes of chilled water piping inside the building (with necessary clamps, vibration isolators and fittings but excluding valves, strainers, gauges etc.) duly insulated with following closed cell elastometric nitrile rubber of minimum 45 Kg / cu m density, thermal conductivity 0.037 W/MK or better at 20 deg mean temperature class 'O' insulation applied by suitable adhesive complete including repairing of damage to building etc. as per specifications and as required complete in all respect.
Note:- The Pipes of sizes 150mm & below shall be M.S. 'C' class as per IS : 1239 and pipes size above 150mm shall be welded black steel pipe heavy class as per IS: 3589, from minimum 6.35mm thick M.S. Sheet for pipes upto 350 mm dia. and from minimum 7mm thick MS sheet for pipes of 400 mm dia and above.
100mm dia
80mm dia
65mm dia
Condensate Drain Piping
UPVC piping complete with U-Trap for the AHUs,fittings & accessories as per specification and as required.
50 mm dia
Supplying, fixing, testing and commissioning of following valves, strainers, gauges in the chilled water plumbing duly insulated to the same specifications as the connected piping and adequately supported as per specifications.
BUTTERFLY VALVE (MANUAL) with C I body SS Disc, Nitrile Rubber Seal & O- Ring PN 16 pressure rating for chilled water/hot eater circulation as specified
100mm dia
80mm dia
BALANCING VALVE WITH BUILT IN MEASURING FACILITY with C I body flanged construction with EPDM coated disc with long pitch with protected out pipe insulation & PN 16 pressure rating for chilled / hot water circulation as specified.
100 mm dia
Y - STRAINER of Ductile CI Body flanged ends with stainless steel strainer for chilled / hot water circulation including insulation as specified.
80 mm dia
Supply, installation, testing and commissioning of following sizes electronic, self balancing, pressure independent type dynamic balancing valve (PIBCV) with integrated 2 way modulating control valve in single body along with actuator (BMS compatible) capable of accepting up to 10V DC and up to 20mA electric input signal & shall provide similar transduced feedback output signal to control system & proportionate thermostat, transformer, including connetions cabling etc. as required, Maximum close off pressure less not be less than 6 Bar for upto 50mm valve and 7 Bar for 65mm & above. Valves should have pressure rating of PN16 minimum.
80 mm dia
Supply, installation, testing and commissioning of mercury filled 'V' form thermometer with copper well of approved make complete as required.
Providing and fixing in position Stainless steel 'Water Pressure gauges complete with SS syphon.,gauge valves, mounting, fittings (0 - 7 Kg/Cm2)
Supply and fixing of Automatic Purge valve made of brass, float type, complete with shut off valve
15 mm dia
Ducting, Insulation & Grills
Rectangular GI Ducting
Supply, installation of factory fabricated completely finished and boxed ducts (including the duct flange). All sheet shall be Class VIII – light coating of zinc, nominal 120 gsm / sqmt surface area including two sides and Lock Forming Quality prime material along with mill test certificates. TDF type flanges with rubber gaskets of thickness to match the dimensions of the ducts shall be used for connecting two ducts complete with necessary Hitech supports. The duct sealing requirement shall be of class 'B' to ensure the duct leakage shall not to exceed as per SMACNA leakage class 12. The Duct to be manufactured and tested as per SMACNA standard for Class-500 pascals.
Thickness 1.25 mm Ducting
Supply, installation of factory fabricated completely finished oval spiral ducts. The Duct to be manufactured and tested as per SMACNA standard.
Acoustic Lining of Duct
Supply and fixing of acoustic lining of supply air duct and plenum with 25 mm thick resin bonded glass wool having density of 32kg/m³, with Reinforced Plastic tissue paper and 0.5 mm thick perforated aluminum sheet fixed to inside surface of ducts with cadmium plated nuts, bolts, stick pins, CPRX compound etc. complete as required and as per specifications.
Duct Thermal Insulation
Supplying and fixing of following thickness duly laminated aluminum foil of mat finish closed cell Nitrile rubber (Class "O") insulation on existing duct after applying suitable adhesive for Nitrile rubber. The joints shall be sealed with 50 mm wide and 3 mm thick self adhesive nitrile rubber tape insulation complete as per specifications and as required
19 mm thick
Supplying and fixing of Thermal insulation of exposed ducts with 50mm thick EPS Insulation finished with sand cement plastering.
Fire Dampers
Supplying, Fixing,testing and commissioning of fire dampers in supply air duct/main branch and return air path as and where required of required sizes i/c control wiring,the damper shall be motorized and spring return so as to close the damper in the event of power failure automatically and open the same in case of power being restored. The spring return action shall be inbuilt mechanism and not externally mounted. The damper shall also be closed in the event of fire signal complete as required and as per specifications.
Fire dampers
Actuator
Supply, installation, testing and commissioning of Motorized (ON-OFF Type) duct mounted GI volume control damper with enthalpy sensor and necessary control wire (minimum 1.5 sqmm) for integration within AHU room.
Damper
Actuator
Grills, Diffusers and Louvers
Supply,installation,testing & commissioning of Powder coated extruded Aluminium Supply air grille with aluminium volume control dampers as per specification
Supply,installation,testing & commissioning of Powder coated extruded Aluminium Return air grille but without volume control dampers as required
Supplying & fixing of Fresh air intake louvers bird screen type with prefilter and aluminium wire mesh (Aluminium extruded only) as per specification and sizes will be as per shop drawing.
Supplying & fixing of door transfer grills for toilets as required
Underdeck Roof Insulation
Supply, installation, testing and commissioning of thermal underdeck insulation with 25mm plain Closed Cell plain nitrile rubber (Class 'O') of density 40-60 Kg/m³, thermal Conductivity of 0.037 W/mK at 20 deg c temperature along with complete required supports as per specifications.
AHU Room Accoustic Insulation.
Supplying, fixing acoustic lining on wall and ceiling of AHU rooms with 50mm thick, density 32 kg/cu.m resin bonded glass fiber insulation friction fixed in 610mm x 610 mm frame work made of 25X50X50X50X25 mm made out of 0.6mm thick GI sheet U shaped channel and covered with reinforced fiber glass tissue and finished with 0.80 mm perforated aluminium sheet etc. complete as required and as per specifications.
Suvidha Engineers India Pvt Ltd
TRAC FUJICO AIR SYSTEMS LLP
Airtech India
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .