| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹32.9 CrAdmitted-Finance NO 4 GROUND FLOOR ALAYAM SPACE ANANDHA ROAD ALWARPET CHENNAI 600 018 | CHENNAI | TAMIL NADU | 600018 | ₹32.9 Cr | L1 | Admitted-Finance |
| 2 | L2₹34.1 CrAdmitted-Finance K 99 LGF KALKAJI NEW DELHI 110 019 | NEW DELHI | SOUTH EAST DELHI | DELHI | 110019 | ₹34.1 Cr | L2 | Admitted-Finance |
| 3 | L3₹36.3 CrAdmitted-Finance NO 35 DADAGAPATTY SALEM SOUTH TALUK SALEM | SALEM | SALEM | ₹36.3 Cr | L3 | Admitted-Finance |
| 4 | L4₹39.3 CrAdmitted-Finance ERODE 638 002 | ₹39.3 Cr | L4 | Admitted-Finance |
| 5 | Rejected-Technical | - | - | Rejected-Technical See evaluation report |
| Sl No | Description | Qty | Unit | SOOD ASSOCIATES PVT LTD L2 | S.S.NATARAJAN AND CO L4 | AADHISHIVAM ENGINEERING CONSTRUCTION LLP L3 | KCP INFRA LIMITED L1 |
|---|---|---|---|---|---|---|---|
| 1.01BOQ uploaded on 11 Sep 2023 | |||||||
| 1.02GENERAL SUMMARY NOTE: Schedule ‘A’ Part IA and II to XIII under Ser No. 2.00 to 14.00 are Prepriced by MES. Bidders shall insert their lumpsum amount in the Green coloured field under Col-6 only. | |||||||
| 2.00 | Lumpsum price worked out by the contractor for “Miscellaneous Buildings/Structures” as listed in Schedule ‘A’ Part–IA. | 1 | Lumpsum | 80,05,000 ₹80.0 L | 91,39,103 ₹91.4 L | 80,00,000 ₹80 L | 88,05,500 ₹88.1 L |
| 3.00 | Lumpsum price worked out by the contractor for “Site Clearance/Development” as listed in Schedule ‘A’ Part–II | 1 | Lumpsum | 3,25,775 ₹3.3 L | 3,01,297 ₹3.0 L | 7,30,000 ₹7.3 L | 8,08,280 ₹8.1 L |
| 4.00 | Lumpsum price worked out by the contractor for "Internal Water Supply” as listed in Schedule ‘A’ Part–III | 1 | Lumpsum | 40,91,818.87 ₹40.9 L | 41,58,564 ₹41.6 L | 27,00,000 ₹27 L | 13,36,173 ₹13.4 L |
| 5.00 | Lumpsum price worked out by the contractor for “Internal Electrification” as listed in Schedule ‘A’ Part–IV | 1 | Lumpsum | 73,58,988.84 ₹73.6 L | 60,36,389 ₹60.4 L | 75,00,000 ₹75 L | 80,51,816 ₹80.5 L |
| 6.00 | Lumpsum price worked out by the contractor for “Road/Path” as listed in Schedule ‘A’ Part–V | 1 | Lumpsum | 1,01,65,136.66 ₹1.0 Cr | 1,07,11,633 ₹1.1 Cr | 95,00,000 ₹95 L | 97,09,935 ₹97.1 L |
| 7.00 | Lumpsum price worked out by the contractor for “Area Drainage” as listed in Schedule ‘A’ Part–VI | 1 | Lumpsum | 19,15,152.41 ₹19.2 L | 19,63,739 ₹19.6 L | 17,50,000 ₹17.5 L | 20,10,396 ₹20.1 L |
| 8.00 | Lumpsum price worked out by the contractor for “Sewage Disposal” as listed in Schedule ‘A’ Part–VII | 1 | Lumpsum | 12,68,589.33 ₹12.7 L | 16,81,886 ₹16.8 L | 12,00,000 ₹12 L | 13,67,330 ₹13.7 L |
| 9.00 | Lumpsum price worked out by the contractor for “Compound Wall & Gate” as listed in Schedule ‘A’ Part–VIII | 1 | Lumpsum | 12,37,845.59 ₹12.4 L | 17,95,710 ₹18.0 L | 12,00,000 ₹12 L | 12,11,124 ₹12.1 L |
Tender Value
₹27.3 Cr
EMD Value
₹15 L
Closing Date
5 Oct 2023, 6:00 pmClosed
Chief Engineer AF Bangalore
Chief Engineer AF Bangalore No. 2 DC Area MES Road Yeshwantpur Post Bangalore 560022
PROVN OF MD ACCN AT AFAC COIMBATORE
2023_MES_597095_1
801460/E8
Open Tender
Civil Works
910 days
AGE (I) (AF) COIMBATORE
As per NIT
8 documents required · 8 mandatory
₹3,000
AGE (I) (AF) Coimbatore
₹15 L
Yes
28 Oct 2023
20 May 2023
12 Oct 2023
31 Jul 2023
5 Oct 2023
21 Sept 2023
19 Aug 2023 - 31 Aug 2023
Amount
BOQ uploaded on 11 Sep 2023
GENERAL SUMMARY NOTE: Schedule ‘A’ Part IA and II to XIII under Ser No. 2.00 to 14.00 are Prepriced by MES. Bidders shall insert their lumpsum amount in the Green coloured field under Col-6 only.
Lumpsum price worked out by the contractor for “Miscellaneous Buildings/Structures” as listed in Schedule ‘A’ Part–IA.
Lumpsum price worked out by the contractor for “Site Clearance/Development” as listed in Schedule ‘A’ Part–II
Lumpsum price worked out by the contractor for "Internal Water Supply” as listed in Schedule ‘A’ Part–III
Lumpsum price worked out by the contractor for “Internal Electrification” as listed in Schedule ‘A’ Part–IV
Lumpsum price worked out by the contractor for “Road/Path” as listed in Schedule ‘A’ Part–V
Lumpsum price worked out by the contractor for “Area Drainage” as listed in Schedule ‘A’ Part–VI
Lumpsum price worked out by the contractor for “Sewage Disposal” as listed in Schedule ‘A’ Part–VII
Lumpsum price worked out by the contractor for “Compound Wall & Gate” as listed in Schedule ‘A’ Part–VIII
Lumpsum price worked out by the contractor for “External Water Supply” as listed in Schedule ‘A’ Part–IX
Lumpsum price worked out by the contractor for “External Electric Supply” as listed in Schedule ‘A’ Part–X
Lumpsum price worked out by the contractor for “Lightning Protection” as listed in Schedule ‘A’ Part–XI
Lumpsum price worked out by the contractor for “Fire Fighting” as listed in Schedule ‘A’ Part–XII
Lumpsum price worked out by the contractor for “Demolition/Dismantling” as listed in Schedule ‘A’ Part–XIII
SCHEDULE `A' Parts - I and Parts - XIV to XVII are not prepriced by MES and prepriced rates indicated 0.0 under column 5 signifies this fact only. Bidders shall insert their rates in Green field under Col-6.
SCHEDULE 'A' PART - I (Building or Works) : Design and Construction of Married Accn for Sqn Ldr & Flt Lt & MNS including servant quarters, garages/stilt in 7 storey (Stilt + 06 storey) framed construction with permanent specifications in RCC M-30 with fly ash brick masonry panel walls, ATT, PU based WPT, earthquake resistance as per latest IS etc complete all as specified and as shown on drawings.
Design and Construction of Married Accn for MWO/WO/JWO including garages/stilt in 5/6 storey (Stilt + 05 storey) framed construction with permanent specifications in RCC M-30 with fly ash brick masonry panel walls, ATT, PU based WPT, earthquake resistance as per latest IS etc complete all as specified and as shown on drawings.
SCHEDULE 'A' PART - XIV ( Fittings, fixtures & Miscellaneous items)
INTERNAL WATER SUPPLY : Supply and fix Brass chromium plated Angle Cock 15mm dia complete all as directed.
Supply and fix 15mm dia bore chromium plated Bib taps long body, cast copper alloy with crutch or butter fly handle, screwed down, screwed for iron pipe /PP-R pipes or for brass ferrule etc all as directed.
Supply and fix kitchen sink tap chromium plated finish dual flow pattern with and including silicon clack flexible hose swivel type fixed for 15mm dia bore of pipe all as directed.
Supply and fix Health faucet (ABS body) mild steel chromium plated suitable for 15mm dia pipe with and including1.25m long flexible tube and ABS wall hook including making connections and fixed in position complete all as directed.
Supply and fix chromium plated shower rose with and including shower arm and swivel joints, size 80mm all as directed.
Supply and fix 3 in 1 hot and cold water mixer control type, brass body chromium plated with wall shower connections fixed to 15mm dia bore of pipes all as directed.
Supply and fix Wash hand bsin mixer Tap with Hot and Cold water controls type, brass body chromium plated fixed to 15mm dia bore of pipes all as directed.
Supply and fix Bib taps suitable for washing machine, brass body, chromium plated fixed to 15mm dia of pipes all as directed. Note for items 20 to 27: All the items shall be ISI marked and shall be procured from approved manufacturers listed here-in-after.
INTERNAL ELECTRIC SUPPLY
S & F Exhaust fan made of sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, Copper winding of sweep 300mm with minimum 50 CFM complete, with cable 3 core of size 0.5 sqmm from ceiling rose to fan, including writing MES No 2cm height with synthetic enamel black paint all as specified and as directed.
Supply, Fixing and testing of 4ft LED surface & wall mounted batten LED luminaires, 18/20 Watts, extruded aluminium housing provided for efficient heat dissipation with polycarbonate diffuser and integral electronic driver fixed complete including all accessories and provision of PVC sheathed multisttanded copper conductor for connection complete all as specified and directed. Make : Havells Cat No ENDURALINEARNEOBS20WLED830SPCWH/ Wipro Cat No LM34-251XXX-57DDGI/ Philips Cat No BN150WLED20S-6500 PSCOD GR or equivalent as per Annexure
Supply, Fixing and testing of 2ft LED surface & wall mounted batten LED luminaires, 9/10 Watts, extruded aluminium housing provided for efficient heat dissipation with polycarbonate diffuser and integral electronic driver fixed complete including all accessories and provision of PVC sheathed multistranded copper conductor for connection complete all as specified and directed. Make : Havells Cat No ENDURALINEARNEOBS10WLED830SPCWH/ Wipro Cat No LM34-930300L57WCG1/ Philips Cat No BN021 LED 10S-6500 PSU GRS1 or equivalent as per Annexure
Supply, Fixing and testing of 4ft LED surface & wall mounted batten LED luminaires, 18/20 Watts, T8, 1980 Lumens with radar motion sensor with detection range 25 feet 360 degree auto dimming to 10 percent when no movement sensed for 30 sec (cool white 6500K) wall/ceiling mounted and integral electronic driver fixed complete including all accessories and provision of PVC sheathed multistranded copper conductor for connection complete all as specified and directed.
Supply, Fixing and testing of round ceiling mounted LED luminaires, 10/12 Watts, with radar motion sensor with detection range 25 feet 360 degree auto dimming to 10 percent when no movement sensed for 30 sec (cool white) wall/ceiling mounted and integral electronic driver fixed complete including all accessories and provision of PVC sheathed multistranded copper conductor for connection complete all as specified and directed.
Supply and Fix LED light fitting 1x9W/1X10W bulkhead luminaires including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size all as specified and as directed for 5th to 8th Floor
Supply and Fix LED light fitting 1x9W/1X10W bulkhead luminaires including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size all as specified and as directed above 8th Floor
Supply, Fixing and testing of surface mounted (ceiling) cylindrical profile luminaires with efficient illumination provides beautiful ambience in open ceiling and collaborative space suitable for 10/12 watt LED downlighter complete including all accessories and provision of PVC sheathed multistranded copper conductor for connection complete all as specified and directed. Make. Wipro Cat No LD30-101-36B-40-SS/ Philips Cat No DN170C LED10S-6500 PSU WH or equivalent as per Annexure
Supply, Fixing and testing of wall mounted cylindrical profile luminaires with efficient illumination provides beautiful ambience chrome and metal space suitable for 10/12 watt LED light complete including all accessories and provision of PVC sheathed multistranded copper conductor for connection complete all as specified and directed. Make: Philips cat No 32029/11/66 aquafit or equivalent as per Annexure
Supply, fixing and testing 20W High efficient LED Streetlight, pressure die cast housing alongwith prismatic polycarbonate diffuser and LEDs with secondary optics and IP-65 protection including fixing arrangement made out of 32 mm light grade MS pipe 1.2 M, bent to shape fixed with MS clamps and connecting with twin twisted flexible copper conductor cable of size 0.75 sqmm complete all as directed. Make- Bajaj Cat No- BCLST 20W LED1 V2/ Havells Cat No ENDURAPEARLSL20WLED757SASYTOPC/ Philips Cat No BRPO22 LED 20 CW MR S1PSUGR or equivalent as per Annexure Note: (for item Nos. 31 to 39):- All LED lights shall be of instant start and there shall be electrical isolation between input and output circuits of the driver and driver shall be inbuilt.
Supply, install, testing and commissioning of Geyser 25 Ltr capacity, high pressure upto 8 Bar ABS plastic body, anticorrossive protection horizontal/ vertical type 230 volt, AC including NRV stop cock cold and hot water connection 3 core electric cable upto power point etc complete all as directed. Make- Havells/Bajaj/Racold
Supply and Fix TV Socket/ telephone sockets all as directed Make: Schneider Cat No IN8431TV or equivalent as per Annexure
Supply and Fix Blank off Modular cover 1 module size complete all as directed. Note: Ports / Sockets shall be provided by user as per site requirement.
Supply and Fix Wall mounting fan 3 blade, 400 mm sweep with remote control for ease of operation, advanced touch screen panel for manual operation, heavy duty 1330 RPM, 4 speed, single phase 240 Volts AC 50 HZ including provision of 3 core 0.5 sqmm cable and connecting up complete all as specified and as directed. Make:Orient Model Wall 49 or equivalent as per Annexure
Supply and Fix Single pole and neutral enclosure with a two pin earth plug and socket 20 Amps complete with one double pole MCB 20 Amps complete all as specified and as directed. Make:- Schneider electric Cat No- NBKRENPSSN20 or equivalent as per Annexure
Supply and fixing smart three phase four wire energy meter BIS 16444:2015 (Reaffirmed 2020) fitted in new meter panel board/floor panels having current range 10-60 amps, 415 volts, accuracy class 1.0 all as directed including connecting incoming/outgoing cables with proper connectors.
Supply and fixing smart single phase four wire energy meter BIS 16444:2015 (Reaffirmed 2020) fitted in new meter panel board/floor panels having current range 10-60 amps, 415 volts, accuracy class 1.0 all as directed including connecting incoming/outgoing cables with proper connectors.
NOTE for items 45 & 46 : (i) Make: Secure Model liberty 200, L & T, Havells, HPL or equivalent as per annexure. (ii) Clearance cyber security to be obtained from user. (iii) Provision of the software for smart prepaid meters shall be the same OEM and developed in India only (Third party software is not acceptable), meter working with both prepaid and post paid technology. When data is not working due to any reason (like unpaid sim bill, network issue or any administrative issue) users can recharge the token automatically and manually in the meter keypad end to end solution provided by OEM of meters.
(iv)Third party/technology partner not allowed in any operations/stage. The system should have all possible payment/recharge modes, be it online and offline mode for officers convenience, system should have 2-3 options for every operation like token recharge in meters by cellular network, Bluetooth, RF,PLC and must manually officers not depend on smartphones for recharge of meters and for watch day to day meters data. User can check his mobile and on meter display like money balance, month wise unit, monthly amount, voltage current, PF, MD etc. The integration of software for servers and vending system shall be the responsibility of OEM. OEM has the option to provide additional server if he desires due to technical requirement without any extra cost to the department. However, no extra charge will be paid for connectivity to the server. OEM will be responsible for connectivity and smooth functioning with MES server without any hindrance.
Supply, install, test and commissioning LT electric control panel indoor, cubical type conforming to IP43 protection in accordance with IS 13947(part-I) 1993 made of 2 mm thick CRCA sheet for outer panel and 1.6mm thick for internal compartments totally enclosed weather duct and vermin proof, powder coated, CPRI type tested front and rear opening fault level of 50 KA, 433V 3 phase 4 wire 50 Hz with aluminium bus bar of capacity 300 Amps for phases and 200 Amps for neutral with suitable CT's cable alley etc and of suitable size for accomodating and including the following switch gear and instrumentation all as specified as directed for Offrs Qtr:-
Supply, install, test and commissioning LT electric control panel indoor, cubical type conforming to IP43 protection in accordance with IS 13947(part-I) 1993 made of 2 mm thick CRCA sheet for outer panel and 1.6mm thick for internal compartments totally enclosed weather duct and vermin proof, powder coated, CPRI type tested front and rear opening fault level of 50 KA, 433V 3 phase 4 wire 50 Hz with aluminium bus bar of capacity 300 Amps for phases and 200 Amps for neutral with suitable CT's cable alley etc and of suitable size for accomodating and including the following switch gear and instrumentation all as specified as directed for Sgt Qtr:-
Supply, install, test and commissioning LT electric Meter panel board , cubical type conforming to IS made of 2 mm thick CRCA sheet for outer panel and 1.6mm thick for internal compartments totally enclosed dust and vermin proof, powder coated with approximate dimensions, front hinged door, with locking arrangement front view transparent glass for taking meter reading for KWH meter, Backlite 6 mm thick sheet back plate for fixing meter, internal wiring with suitable capacity copper cables etc, 433V 3 phase 4 wire 50 Hz with aluminium bus bar of capacity 100 Amps for phases and 75 Amps for neutral with suitable CT's cable alley etc and for accomodating and including the following switch gear and instrumentation all as specified as directed (for 9 Nos JCO Qtr):-
(i) MCCB TPN 100 Amps 25 KA rupturing capacity as incoming - 1 No (ii) MCB SPN 32 Amps 10 KA capacity- 10 Nos (iii) Provision for fixing Single phase KWH meter - 10 Nos.
Supply, install, test and commissioning LT electric Meter panel board, cubical type conforming to IS made of 2 mm thick CRCA sheet for outer panel and 1.6mm thick for internal compartments totally enclosed dust and vermin proof, powder coated with approximate dimensions, front hinged door, with locking arrangement front view tranparent glass for taking meter reading for KWH meter, Backlite 6 mm thick sheet back plate for fixing meter, internal wiring with suitable capacity copper cables etc, 433V 3 phase 4 wire 50 Hz with aluminium bus bar of capacity 100 Amps for phases and 75 Amps for neutral with suitable CT's cable alley etc and for accomodating and including the following switch gear and instrumentation all as specified as directed for Offrs Qtr
(i) MCCB TPN 150 Amps 25 KA rupturing capacity as incoming - 1 No (ii) MCB TPN 40 Amps 10 KA capacity - 06 Nos (iii) Provision for fixing Three phase KWH meter - 06 Nos.
Supply, install, test and commissioning LT electric Meter panel board, cubical type conforming to IS made of 2 mm thick CRCA sheet for outer panel and 1.6mm thick for internal compartments totally enclosed dust and vermin proof, powder coated with approximate dimensions, front hinged door, with locking arrangement front view tranparent glass for taking meter reading for KWH meter, Backlite 6 mm thick sheet back plate for fixing meter, internal wiring with suitable capacity copper cables etc, 433V 3 phase 4 wire 50 Hz with aluminium bus bar of capacity 100 Amps for phases and 75 Amps for neutral with suitable CT's cable alley etc and for accomodating and including the following switch gear and instrumentation all as specified as directed for Sgt Qtr
(i) MCCB TPN 100 Amps 25 KA rupturing capacity as incoming - 1 No (ii) MCB SPN 32 Amps 10 KA capacity- 10 Nos (iii) Provision for fixing single phase KWH meter - 10 Nos.
M & L for Sub main wiring with 4 single core PVC insulated cable with copper conductor multistranded 1100 volts grade 6 sqmm in 25 mm dia PVC conduit with accessories concealed in wall/ceiling etc including 1x6 sqmm PVC insulated multistranded copper earth continuity conductor and connecting to main earth dolly complete all as specified and directed upto 4th Floor Note : One run of earth continuity conductor, one run of PVC conduit and four runs of copper conductor together taken as one length for measuring unit length
All as per item No 59 above but for 5th to 8th Floor
M & L for Sub main wiring with 2 single core PVC insulated cable with copper conductor multistranded 1100 volts grade 6 sqmm in 20 mm dia PVC conduit with accessories concealed in wall/ceiling etc including 1x6 sqmm PVC insulated multistranded copper earth continuity conductor and connecting to main earth dolly complete all as specified and directed upto 4th Floor Note : One run of earth continuity conductor, one run of PVC conduit and two run of copper conductor together taken as one length for measuring unit length
All as per item No 61 above but for 5th to 8th Floor
All as per item No 61 above but above 8th Floor
Sub main wiring with 2 single core PVC insulated cable with copper conductor multistranded 1100 volts grade 4 sqmm in 20 mm dia PVC conduit with accessories concealed in wall/ceiling etc including 1x6 sqmm PVC insulated multistranded copper earth continuity conductor and connecting to main earth dolly complete all as specified and directed upto 4th Floor Note : One run of earth continuity conductor, one run of PVC conduit and two run of copper conductor together taken as one length for measuring unit length
All as per item No 64 above but for 5th to 8th Floor
All as per item No 64 above but above 8th Floor
M & L for Sub main wiring with 2 single core PVC insulated cable FRLS with copper conductor multistranded 1100 volts grade 2.5 sqmm in 20 mm dia PVC conduit with accessories concealed in wall/ceiling etc including 1x2.5 sqmm PVC insulated multistranded copper earth continuity conductor and connecting to main earth dolly for building security lights complete all as specified and directed . Note : One run of earth continuity conductor, one run of PVC conduit and two runs of copper conductor together taken as one length for measuring unit length.
ROAD/PATH
M & L painting 2.5mm thick road marking strips not exc 10cm width or girth for layout of centre line, dashes, arrows, speed breakers, writing letters etc with thermoplastic road marking paint (reflective) of specified shade or colour by using fully automatic thermoplastic paint application machine fitted with profile shoe, glass beads, spensen, propane tank heater and profile shoe heater, driven by experienced operator on road surface including road marking paint spray machine as in lines, dashes, letter, arrows etc complete all as directed.
All as per item 69 above but exceeding 10cm width or girth.
SEWAGE DISPOSAL
M & L for Rungs formed out of MS rod of 16mm dia for steps encapsulated with PVC of size 180 mm x 270mm (130mm concealed with concrete and 140mm projected) all as specified and as directed.
S & F SFRC heavy duty cover of dia 560mm (clear open), 900mm outer to outer for manholes complete with specification as per IS 12592 (2002) comprising high tech concrete, FI 90x 1.35mm thick outer cover, 4mm TMT wire mesh (core wire) with hook 4mm, 8mm TMT bar @ 100C/C at bottom, 10mm TMT bar @ 100mm C/C at top, 16mm TMT bar for flushed handles, RCC M-35 (Design Mix) concrete, outer cover/collar of metal sheet 1.4mm thick and width 90mm all as specified and as directed.
EXTERNAL WATER SUPPLY
Cutting the existing cast iron water supply pipe line of 100 mm dia for inserting suitable size and sockets of size 80mm dia for taking branch connection for main water line complete all as directed.
S & F Non return Valve 50 mm dia, of gunmetal, screwed both ends ISI marked with all connected accessories complete all as specified and as directed.
Construction of valve chamber of size 600mmx600mmx900mm internal size suitable for 50mm Gate Valves including necessary earth work excavation, PCC 1:4:8 type D2 150mm thick for foundation, Brick masonry 230mm wall in cement mortar 1:4, PCC 1:2:4 type B1 for coping, 15mm thick rendering in cement mortar 1:4 including provision of mild steel sheet cover 3mm thick on 25x25x3 mm angle iron frame work embedded in coping with 2 coats of synthetic enamel paint over a coat of red oxide zinc chrome primer and locking arrangements complete all as specified and as shown on drawings.
Supply, install, test and commissioning of pumping set 7.5 HP, monoblock 3 Phase 400 V, electric driven 300 LPM at 44 mtr head, 2900 RPM, 415 V, 50 HZ inclusive of FASD starter with suitable capacity including necessary enclosure and PCC foundation etc., with all connected accessories complete all as specified and as directed.
Supply, install, test and commissioning of pumping set 5 HP, monoblock 3 Phase 400 V, electric driven 300 LPM at 36 mtr head, 2900 RPM, 415 V, 50 HZ inclusive of FASD starter with suitable capacity including necessary enclosure and PCC foundation etc., with all connected accessories complete all as specified and as directed.
S & F Cast iron Foot Valve 63 mm dia, ISI marked with all connected accessories complete all as specified and as directed.
EXTERNAL ELECTRIC SUPPLY
Returning and filling of trenches in two parts (i) using riddled soil obtained from excavated soil upto depth of 30cm (8cm below cable and remaining above cable) for cushioning of cable and (ii) refilling the trench of remaining depth with normal excavated soil all as specified and directed. Note: - Excavated soil shall be riddled by using sieve to separate composite particles etc as per IS 1255-1983 and refilling in trenches as in cable cushioning.
Supply, install, test and commissioning of transformer stepdown 100 KVA outdoor type Oil immersed, ONAN copper wound complete with all standard accessories, vector group DYN 11/0.415 suitable for continuous duty for operation on AC 3 phase, 50 HZ with off load Tap changer to vary secondary voltage+ 7.5 % in steps of 2.5% including transformer oil upto appropriate level all as per IS : 1180-2014 with energy efficiency level-2 and complete with and including PCC platform of size 1.50 Mtr X 1.50 MtrX 1.20 Mtr (above GL) and with and including following fitting/accessories all as directed:-
(a) Conservator with oil filing hole, drain plug, oil level indicator. (b) Two nosearthing terminal (c) Rating and diagram plate. (d) Air release plug, (e) Off load tap charger, (f) Silica gel breather, (g) Four nos Bi-directional rollers, (h) Drain cum filter valve, (j) Top filter vlave, (k) Thermometer pocket (l) Radiator with butterfly valves, (m) Explosion vent with single diaphragm, (n) HV cable box, (o) LV cables Note: Necessary provision is required to entry box of transformer for LT cables 3.5 core 185 Sqmm single run on LT side and 3 core 95 Sq mm cable on HT side including fixing arrangement in transformer with terminal box etc.
Supply, installation, testing and commissioning of Automatic Power Factor Control panel (APFC) panel of capacity 50 KVAR, indoor, floor mounted, pedestal type, cubical, compartmentalised self supported, CPRI approved make, front and rear openable, hinged type with locking arrangement, suitable ventilations on both sides with wire mesh, IP-23 protection with dust and vermin proof, etc., fabricated out of 3.15mm CRCA sheet duly powder coated, mounted/fixed on and including MS angle iron stand/frame 40 cm height from FFL, fabricated out of 50x50x6mm thick MS angles duly painted with black enamel synthetic paint over a red oxide primer duly grouted in PCC 1:3:6 foundation, control wiring copper stranded PVC insulated FRLS cables not less than 1.5 Sqmm, suitable size/capacity of copper strips for switch gear connection from main bus bar, earth bus strip of 32/6mm size for entire length of panel, suitable size of MS gland plate and aluminium lugs/thimbles for all incoming/outgoing cables etc., complete all as directed.
Supply & Fix Double compression copper/stainless steel gland for fixing armoured cable suitable for 3.5 core 300 Sqmm all as directed.
Supply & Fix Double compression copper/stainless steel gland for fixing armoured cable suitable for 3.5 core 185 Sqmm all as directed.
Supply & Fix Double compression copper/stainless steel gland for fixing armoured cable suitable for 3.5 core 120 Sqmm all as directed.
Supply & Fix Double compression copper/stainless steel gland for fixing armoured cable suitable for 3.5 core 95 Sqmm all as directed.
Supply & Fix Double compression copper/stainless steel gland for fixing armoured cable suitable for 3.5 core 70 Sqmm all as directed.
Supply & Fix Double compression copper/stainless steel gland for fixing armoured cable suitable for 3.5 core 50 Sqmm all as directed.
Supply & Fix Double compression copper/stainless steel gland for fixing armoured cable suitable for 3.5 core 35 Sqmm all as directed.
Supply & Fix Double compression copper/stainless steel gland for fixing armoured cable suitable for 2 core 10 Sqmm all as directed.
Supply & Fix LED 70 W street light fitting made up of pressure die cast housing with toughened glass and individual high power LEDs with secondary optics, IP 65 protection and impact resistance of IK07 including provision of suitable size dia GI light grade pipe 1.5m length bent to shape and necessary clamps etc for fixing the light fittings on wall/pole fixed complete all as directed . Make: Cat Co. LHETBXU7PA6J070 of Havells or its equivalent as per list of manufacturers.
Supply & Fix Junction boxes outdoor type weather proof made out of moulded PVC of size 250 x 200 x 100mm of make Sintex Cat No. GSJB 2520 or Hensol or equivalent to be fixed at the bottom of street light pole complete with arrangement for 2 Nos GI pipe for cable entry/exit, 01 No. MCB SP 6 Amps, 4 Pole connector for fixing cable etc., including one run of 3 core PVC sheathed 1.5 Sqmm copper cable for connection from junction box to street light upto a height of 7.5 m complete all as specified and as directed.
Earthing complete with galvanised steel earth plate electrode 600 x 600 x 6mm thick buried in ground vertically to a depth not less than 2.25m below ground level with top edge of the earth plate not less than 1.5m below normal ground level, connected to GI strip 32x6mm protected with 40mm bore GI light grade pipe by means of bolts, nuts, check nuts and washers made out of galvanised iron or steel connected to test point upto 7.5 mt away from earth electrode all as shown as per plate No 05 of SSR part - I including necessary earth work, PCC 1:2:4 type B1 chamber, RCC 1:2:4 type B1 using 20mm graded stone aggregate cover slab of 450 mm x 450mm x 40mm thick with 8 mm TMT bars at 150 mm C/C bothways with suitable GI handle, watering pipe 20 mm dia medium grade pipe with funnel, charcoal, salt and testing on completion all as directed. (DG Set - 38, Ext. electric supply - 38, Lightning protection - 6, Fire Fighting 6)
M&L for Earthing complete with copper earth plate electrode 600 x 600 x 3.15mm thick buried in ground vertically to a depth not less than 2.25m below ground level with top edge of the earth plate not less than 1.5m below normal ground level, connected to copper strip 20x3mm protected with 40mm bore GI light grade pipe by means of bolts , nuts, check nuts and washers made out of galvanized iron or steel connected to test point upto 7.5 mt away from earth electrode all as shown as per pate No 05 of SSR part – I including necessary earth work, PCC 1:2:4 type B1 using 20mm graded stone aggregate cover slab of 450 mm X 450mm X 40mm thick with 8 mm TMT bars at 150mm C/C bothways with suitable GI handle, watering pipe 20 mm dia medium grade pipe with funnel, charcoal, salt and testing on completion all as directed (For Lifts – 14)
Earthing complete with galvanised steel earth plate electrode 600 x 600 x 6mm thick buried in ground vertically to a depth not less than 2.25m below ground level with top edge of the earth plate not less than 1.5m below normal ground level, connected to galvanised earth lead wire 4.00mm GI earth continuity conductor including 15 mm bore pipe Light grade for protection of lead by means of bolts, nuts, check nuts and washers made out of galvanised iron or steel connected to maint switch control board upto 7.5 mt away from earth electrode all as shown as per plate No 03 of SSR part - I including necessary earth work, PCC 1:3:6 type C1 chamber, RCC 1:2:4 type B1 using 20mm graded stone aggregate cover slab of 50 mm thick with 8 mm TMT bars at 140 mm C/C with suitable GI handle, watering pipe 20 mm dia medium grade pipe with funnel, charcoal, salt and testing on completion and including taking out old unserviceable earthing with connected items all as directed. (Int. electric supply - 22, Ext. electric supply - 3 , Fire fighting- 6)
Supply and install drop out fuse unit assembly triple pole consisting of channel iron base, spring loaded phosphor bronze contact, outdoor for HT 11 KV up to 200 Amps with barrel fuse unit and fuse element complete all as specified.
Supply, fixing, testing and commissioning of 11 KV, 630 Amps, 20 KA manually operated load break switch with fuse units extensible outdoor type with 01 No. cable entering module as incoming, 01 No. fixed type with manual operated load break switch as outgoing, earth switch, bus bars complete all as specified and as directed.
M&L for earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc, as required 20x3mm copper strip.
FIRE FIGHTING
SCHEDULE 'A' PART XV : DG SET
Supply and installation, test and commissioning of acoustic proof diesel engine driven generating set fully wired 415 volts + 5% AC 3 phase 4 wire 50 Hz having capacity 82.5 KVA continuous rating at power factor 0.8 (lagging) as per IS 4722 and connections as per IE rules complete with integrated AMF control panel of suitable capacity with microprocessor based controller unit as per the latest engineering practices . DG set shall be mounted on common base plate with anti vibration pads and placed on PCC foundation of required size as recommended by OEM. The Gen Set shall conform to latest CPCB norms for noise and emission limits and necessary certificate from NAL or equivalant authority to this effect shall be submitted and all as specified and directed consisting of the following :-
(a) DIESEL ENGINE :- The engine shall be liquid cooled turbo charged after cooled type, all lube oil filter, fuel pump, injectors shall be housed outside recker cover to enable easy maintenance. Engine rating shall be as recommended by OEM @ 1500 RPM at NTP, 4 cylinders, fuel pump with mechanical governer, oil filter, Radiator with fan, exhaust and silencer pipe safety devices and other standard fitting such as speedo meter/hours meter etc conforming to IS:10002, BS 5514.
[b] ALTERNATOR: The alternator shall be self excited self regulated brush less and self ventilating type designed for an output of 82.5 KVA, 50 Hz, 415Volts 4 wire continous rating at 0.8 PF, with class 'F' or better insulation, screne protected, drip proof in IP- 23 enclosure and confirming to IS -4722 BS EN 60034-1 rated RPM 1500 and closed coupled with the engine incl control panel with accessories complete with electric supply terminal box with gland plate, earth terminal etc all as specified.
[c] ELECTRICAL SYSTEM The electrical system of the starter motor and charging alternator shall have the following components: (i) Batteries 1 No. - 12V DC x 130 AH or as recommended by OEM. (ii) 12 V electric starter motor, Battery charging alternator [d] FUEL TANK As recommended by OEM
Supply and installation, test and commissioning of acoustic proof diesel engine driven generating set fully wired 415 volts + 5% AC 3 phase 4 wire 50 Hz having capacity 50 KVA continuous rating at power factor 0.8 (lagging) as per IS 4722 and connections as per IE rules complete with integrated AMF control panel of suitable capacity with microprocessor based controller unit as per the latest engineering practices . DG set shall be mounted on common base plate with anti vibration pads and placed on PCC foundation of required size as recommended by OEM. The Gen Set shall conform to latest CPCB norms for noise and emission limits and necessary certificate from NAL or equivalant authority to this effect shall be submitted and all as specified and directed consisting of the following :-
(a) DIESEL ENGINE :- The engine shall be liquid cooled turbo charged after cooled type, all lube oil filter, fuel pump, injectors shall be housed outside recker cover to enable easy maintenance. Engine rating shall be as recommended by OEM @ 1500 RPM at NTP, 4 cylinders, fuel pump with mechanical governer, oil filter, Radiator with fan, exhaust and silencer pipe safety devices and other standard fitting such as speedo meter/hours meter etc conforming to IS:10002, BS 5514.
[b] ALTERNATOR: The alternator shall be self excited self regulated brush less and self ventilating type designed for an output of 50 KVA, 50 Hz, 415Volts 4 wire continous rating at 0.8 PF, with class 'F' or better insulation, screne protected, drip proof in IP- 23 enclosure and confirming to IS -4722 BS EN 60034-1 rated RPM 1500 and closed coupled with the engine incl control panel with accessories complete with electric supply terminal box with gland plate, earth terminal etc all as specified.
[c] ELECTRICAL SYSTEM The electrical system of the starter motor and charging alternator shall have the following components: (i) Batteries 1 No. - 12V DC x 105 AH or as recommended by OEM. (ii) 12 V electric starter motor, Battery charging alternator [d] FUEL TANK As recommended by OEM
SCHEDULE 'A' PART XVI : AVIATION OBSTRUCTION LIGHT
Supply & Fix Aviation obstruction light LED type comprising of aluminium housing with polycarbonate enclosure all as specified and as directed. Make: Bajaj Cat No. BGAV 302 LED or equivalent as per Annexure
Supply & Fix Single Phase Timer panel with 16 A Contactor fitted inside a steel enclosure all as specified and as directed. Make: IndoAsian model : Timelite 16A 3 pole / 230 V - Analog time switch Cat Ref TL016ABO or equivalent in Legrand/Havells or as per Annexure
SCHEDULE 'A' PART XVII : LIFTS
Supply, install, testing & commissioning of 08 Passengers Lifts (544 kg) suitable to serve G+09 upper floors with AC variable voltage & variable frequency (VVVF) drive, gear less complete with all standard accessories, simplex collective automatic & manual dual controlled operation with/without attendant, automatic centre/Telescopic opening doors with VVVF door drive (electric motor driven mechanism), sliding stainless steel doors, automatic rescue device (ARD) system, Over load device, 3D infra red sensor in full height of door & built in announcing system without hand set (04 Nos, one each in car, Machine room & near Ground floor landing door) complete all as specified below :- Note :Lift OEM to submit detailed specification/design parameters, construction drgs of all components of lifts as per IS-14665/NBC 2016 for approval of Garrison Engineer before execution of work. GE & Engr-in- charge shall ensure that detail drg recommendation within one month of issue of WO.
(a) Type of Lifts : 08 Passengers (b) Load capacity : 544 Kgs (c) Speed : 1.5 mtr/sec with variable speed motor (d) Power Supply : 415 volts, 3 phase AC, 50 Hz (e) Type of Drive : AC variable voltage & variable frequency drive along with converter unit. (f) Type of Machine : Low inertia gearless permanent magnet Synchronous motor, directly coupled Horizontal traction machine. (g) Car size (Inside) : Not less than 1.43Sqm (h) Car door & landing door at all floors : Automatic Centre / Telescopic opening with VVVF door drive, opening size not less than 800mmx2000mm, sliding type, fabricated by stainless steel sheet not less than 16 gauge having hair line finish (N - 304 ).
(j) Car enclosure : (i) Manufactured with stainless steel frame stainless steel sheet not less than 16 gauge with hair line finish (N-304) having stainless steel false ceiling with hair line finish, internal lighting arrangement with Four Nos LED light fitting for commercial supply and one No LED for emergency light, internal ventilation system provided with concealed arial flow/cross flow fan with auto cut off system and stainless steel grill/wire mesh for protection. (ii) Provision of standard thickness stainless steel hand rail 40mm dia inside the car cabin .(01 Side) including standard size Mirror on one side (k) Terminal buffers : Metal special spring/oil buffers as per manufacturer specification. The buffing stroke should not be less than 200mm. (l) Door opening (Inside) : Protected by centre / Telescopic opening stainless steel doors with hairline finish doors with clear opening size not less than 800 x 2000mm . (m) Car & counter weight Guide : Guide rails of'T Section Mild steel as per OEM design. Counter weight shall be cast iron as recommended by OEM. Flooring : Aluminium chequered plate 5mm thick complete.
(o) Signals :- (i) Combined luminous hall buttons with LCD/VFD hall position indicators at all floor. (ii) LCD/VFD for car position indicator to be fitted in COP made of stainless steel. (iii) One No car operating panel with luminous buttons in car (stainless steel). (iv) Car direction indicator in car & Landing (v) Battery operated alarm bell & emergency light (rechargeable) along with suitable maintenance free battery. (This system should be separate from ARD batteries). (vi) Overload warning feature in car cabinet(Display & announcing both type). (vii) Fireman’s switch one No per lift to be installed at ground Floor near landing door. (viii) All signal fixture & car operating panel on stainless steel face plate with hair line finish. (ix) Infra red door sensor safety edge of door for entire height. (x) Built in announcing system without hand set.02 Nos( One for lift car & ground floor landing door &one announcing system with hand set in machine room).
(p) Stops & Opening : 10-10 Stop and one side opening ( Same side ) at all floors. (q) Safety Device : (i) Automatic rescue device (ARD)/Automatic landing device with maintenance free battery having suitable capacity. The batteries must have auto charging facilities. (ii) The ARD actuation should be after failure of power supply and when ARD is operative the car should stop at the nearest floor and then automatically open. (r) Operation: Simplex, full collective automatic operation with/without attendant. (s) Machine Room : Located about the hoist way(details as per Bldg drg) (t) Hoist-Way Constn : Existing at site details as per Bldg drg (u) Civil Work : Necessary Civil work such as making good disturbed surface, modification to landing space to suits to car size necessary foundation to machine. (v) Control system : shall be enclosed loop type.
(w) Door shall have AC-VVVF controlled close loop operated. (x) Face plate shape shall be rectangular and stainless steel with hairline finish. (y) counter weight shall be of cast iron or as recommended by OEM. (z) One number wall mounted type telephone instrument of make Crompton Greaves / Beetel /OEM own make installed inside of car cabin along with fixing arrangement and telephone cable of suitable size from car cabin to machine room run along with trailing cable. The telephone instrument shall be connected in the telephone DB installed in the machine room. (za) One number electrically operated siren, operating voltage 240 volts having audible range of 0.5 Km of Make : KHERAJ Model No SS050 /OEM own make alongwith One Number inverter unit of suitable capacity but not less than 0.5KVA comprising of maintenance free battery connected with charging system including a separate switch/push button inside of car panel and electric wiring circuit upto the machine room. The siren shall be installed over the building at appropriate place and to be operated from.
Supply, install, testing & commissioning of 13 Passengers Lifts (884 kg) suitable to serve G+09 upper floors with AC variable voltage & variable frequency (VVVF drive) drive, gear less complete with all standard accessories, simplex collective automatic & manual dual controlled operation with/without attendant, automatic centre opening doors with VVVF door drive (electric motor driven mechanism), sliding stainless steel doors, automatic rescue device (ARD) system, 3D infra red sensor in full height of door & built in announcing system without hand set (04 Nos, one each in car, machine room & near Ground floor landing door) complete all as specified and directed. Note :Lift OEM to submit detailed specification/design parameters, construction drgs of all components of lifts as per IS-14665/NBC 2016 for approval of accepting officer before execution of work. GE & Engr-in-charge shall ensure that detail drg shall be forwarded to this HQ for approval with recommendation with in one month of issue of WO.
(a) Type of Lifts : 13 Passenger. (b) Load capacity : 884 Kgs. (c) Speed : 1.5 mtr/sec with single speed motor. (d) Power Supply : 415 volts, 3 phase AC, 50 Hz. (e) Type of Drive : AC variable voltage & variable frequency drive (f) Type of Machine : Low inertia gearless permanent magnet synchronous motor, directly coupled horizontal traction machine. (g) Car size (Inside) : Not less than 2.20 Sqm. (h) Car door and landing door at all floor : Automatic centre / Telescopic opening with VVVF door drive, opening size not less than 900mm x 2000mm, sliding type, fabricated by stainless steel sheet not less than 16 gauge having hairline finish (N-304).
(j) Car enclosure :- (i) Manufactured with stainless steel sheet not less than 16 gauge with hair line finish (N-304), having stainless steel false ceiling with hairline finish, internal lighting arrangement with 04 Nos LED light fitting for commercial supply and one No LED for emergency light each fitting complete, internal ventilation system provided with concealed arial flow/cross flow fan with auto cut off system and stainless steel grill/wire (ii)Provision of standard thickness stainless steel hand rail 40mm dia inside the car cabin. (3 Sides) (k) Terminal buffers : Metal special spring/ Oil buffers as per manufacturer specification. The buffing stroke shall not be less than 200mm. (l) Door opening (Inside) : Protected by centre/ Tlescopic opening stainless steel doors with hairline finish doors with clear opening size not less than 900 x 2000mm. (m) Car & counter weight Guide : Guide rails of 'T Section Mild steel as per OEM design. Counter weight shall be cast iron as recommended by OEM. (n) Flooring : Aluminium chequered plate 5mm thick.
(o) Signals :- (i) Combined luminous hall buttons with LCD/VFD hall position indicators at all floor. (ii) LCD/VFD for car position indicator to be fitted in COP made of stainless steel. (iii) One No car operating panel with luminous buttons in car (stainless steel). (iv) Car direction indicator in car & Landing (v) Battery operated alarm bell & emergency light (rechargeable) along with suitable maintenance free battery. (This system should be separate (vi) Overload warning feature in car cabinet( Display & announcing both type). (vii) Fireman's switch one No per lift to be installed at ground Floor near landing door. (viii) Built in announcing system without hand set.02 Nos( One for lift car & ground floor landing door & one announcing system with hand set in machine room). . (ix) The interior of the car should be provided with a device that audibly indicates the floor position of lift car has reached and indicates that car entrance/exit door is open or closed. (p) Stops & Opening : 10-10 stop and one side opening (same side) at all floors. (q) Safety Device : (i) Automatic rescue devise (ARD)/Automatic landing device with maintenance free battery having suitable capacity. The batteries must have auto charging facilities. (ii) The ARD actuation time should be less than one second after failure of power supply and when ARD is operative the car should stop at the nearest floor and then automatically open
(r) Operation : Simplex, full collective automatic operation with/without attendant. (s) Machine Room : Located above the hoist way. (Details as per appendix attached) (t) Hoist-Way Constn : Existing at site, details as per Appendix attached. (u) Civil work : Necessary civil work such as making good disturbed surfaces, modification to landing space to suit to car size, necessary foundation to machine. (v) Control system shall be enclosed loop type. (w) Door shall have AC-VVVF controlled close loop operated. (x) Face plate shape shall be rectangular and stainless steel with hairline finish. (y) counter weight shall be of cast iron as recommended by OEM. (z) One number wall mounted type telephone instrument of make Crompton Greaves / Beetel/ OEM own make installed inside of car cabin along with fixing arrangement and telephone cable of suitable size from car cabin to machine room run along with trailing cable. The telephone instrument shall be connected in the telephone DB installed in the machine room. (za) One number electrically operated siren, operating voltage 240 volts having audible range of 0.5 Km of make Kheraj, Model No SS050 alongwith one number inverter unit of suitable capacity of not less than 0.5KVA comprising of maintenance free battery connected with charging system including a separate switch/push button inside of car panel and electric wiring circuit upto the machine room. The siren shall be installed over the building at appropriate place and to be operated from inside the car
Supply, install, testing & commissioning of 13 Passengers Lifts (884 kg ) suitable to serve G+06 upper floors with AC variable voltage & variable frequency (VVVF drive) drive, gear less complete with all standard accessories, simplex collective automatic & manual dual controlled operation with/without attendant, automatic centre opening doors with VVVF door drive (electric motor driven mechanism), sliding stainless steel doors, automatic rescue device (ARD) system, 3D infra red sensor in full height of door & built in announcing system without hand set (04 Nos, one each in car, machine room & near Ground floor landing door) complete all as specified and directed. Note :Lift OEM to submit detailed specification/design parameters, construction drgs of all components of lifts as per IS-14665/NBC 2016 for approval of accepting officer before execution of work. GE & Engr-in-charge shall ensure that detail drg shall be forwarded to this HQ for approval with recommendation with in one month of issue of WO.
(a) Type of Lifts : 13 Passenger. (b) Load capacity : 884 Kgs. (c) Speed : 1.5 mtr/sec with single speed motor. (d) Power Supply : 415 volts, 3 phase AC, 50 Hz. (e) Type of Drive : AC variable voltage & variable frequency drive (f) Type of Machine : Low inertia gearless permanent magnet synchronous motor, directly coupled horizontal traction machine. (g) Car size (Inside) : Not less than 2.20 Sqm. (h) Car door and landing door at all floor : Automatic centre / Telescopic opening with VVVF door drive, opening size not less than 900mm x 2000mm, sliding type, fabricated by stainless steel sheet not less than 16 gauge having hairline finish (N-304).
(j) Car enclosure :- (i) Manufactured with stainless steel sheet not less than 16 gauge with hair line finish (N-304), having stainless steel false ceiling with hairline finish, internal lighting arrangement with 04 Nos LED light fitting for commercial supply and one No LED for emergency light each fitting complete, internal ventilation system provided with concealed arial flow/cross flow fan with auto cut off system and stainless steel grill/wire (ii)Provision of standard thickness stainless steel hand rail 40mm dia inside the car cabin. (3 Sides) (k) Terminal buffers : Metal special spring/ Oil buffers as per manufacturer specification. The buffing stroke shall not be less than 200mm. (l) Door opening (Inside) : Protected by centre/ Tlescopic opening stainless steel doors with hairline finish doors with clear opening size not less than 900 x 2000mm. (m) Car & counter weight Guide : Guide rails of 'T Section Mild steel as per OEM design. Counter weight shall be cast iron as recommended by OEM. (n) Flooring : Aluminium chequered plate 5mm thick.
(o) Signals :- (i) Combined luminous hall buttons with LCD/VFD hall position indicators at all floor. (ii) LCD/VFD for car position indicator to be fitted in COP made of stainless steel. (iii) One No car operating panel with luminous buttons in car (stainless steel). (iv) Car direction indicator in car & Landing (v) Battery operated alarm bell & emergency light (rechargeable) along with suitable maintenance free battery. (This system should be separate (vi) Overload warning feature in car cabinet( Display & announcing both type). (vii) Fireman's switch one No per lift to be installed at ground Floor near landing door. (viii) Built in announcing system without hand set.02 Nos( One for lift car & ground floor landing door & one announcing system with hand set in machine room). . (ix) The interior of the car should be provided with a device that audibly indicates the floor position of lift car has reached and indicates that car entrance/exit door is open or closed. (p) Stops & Opening : 07-07 stop and one side opening (same side) at all floors. (q) Safety Device : (i) Automatic rescue devise (ARD)/Automatic landing device with maintenance free battery having suitable capacity. The batteries must have auto charging facilities. (ii) The ARD actuation time should be less than one second after failure of power supply and when ARD is operative the car should stop at the nearest floor and then automatically open
(r) Operation : Simplex, full collective automatic operation with/without attendant. (s) Machine Room : Located above the hoist way. (Details as per appendix attached) (t) Hoist-Way Constn : Existing at site, details as per Appendix attached. (u) Civil work : Necessary civil work such as making good disturbed surfaces, modification to landing space to suit to car size, necessary foundation to machine. (v) Control system shall be enclosed loop type. (w) Door shall have AC-VVVF controlled close loop operated. (x) Face plate shape shall be rectangular and stainless steel with hairline finish. (y) counter weight shall be of cast iron as recommended by OEM. (z) One number wall mounted type telephone instrument of make Crompton Greaves / Beetel/ OEM own make installed inside of car cabin along with fixing arrangement and telephone cable of suitable size from car cabin to machine room run along with trailing cable. The telephone instrument shall be connected in the telephone DB installed in the machine room. (za) One number electrically operated siren, operating voltage 240 volts having audible range of 0.5 Km of make Kheraj, Model No SS050 alongwith one number inverter unit of suitable capacity of not less than 0.5KVA comprising of maintenance free battery connected with charging system including a separate switch/push button inside of car panel and electric wiring circuit upto the machine room. The siren shall be installed over the building at appropriate place and to be operated from inside the car
Supply, install, testing & commissioning of 13 Passengers Lifts (884 kg) suitable to serve G+05 upper floors with AC variable voltage & variable frequency (VVVF drive) drive, gear less complete with all standard accessories, simplex collective automatic & manual dual controlled operation with/without attendant, automatic centre opening doors with VVVF door drive (electric motor driven mechanism), sliding stainless steel doors, automatic rescue device (ARD) system, 3D infra red sensor in full height of door & built in announcing system without hand set (04 Nos, one each in car, machine room & near Ground floor landing door) complete all as specified and directed. Note :Lift OEM to submit detailed specification/design parameters, construction drgs of all components of lifts as per IS-14665/NBC 2016 for approval of accepting officer before execution of work. GE & Engr-in-charge shall ensure that detail drg shall be forwarded to this HQ for approval with recommendation with in one month of issue of WO.
(a) Type of Lifts : 13 Passenger. (b) Load capacity : 884 Kgs. (c) Speed : 1.5 mtr/sec with single speed motor. (d) Power Supply : 415 volts, 3 phase AC, 50 Hz. (e) Type of Drive : AC variable voltage & variable frequency drive (f) Type of Machine : Low inertia gearless permanent magnet synchronous motor, directly coupled horizontal traction machine. (g) Car size (Inside) : Not less than 2.20 Sqm. (h) Car door and landing door at all floor : Automatic centre / Telescopic opening with VVVF door drive, opening size not less than 900mm x 2000mm, sliding type, fabricated by stainless steel sheet not less than 16 gauge having hairline finish (N-304).
(j) Car enclosure :- (i) Manufactured with stainless steel sheet not less than 16 gauge with hair line finish (N-304), having stainless steel false ceiling with hairline finish, internal lighting arrangement with 04 Nos LED light fitting for commercial supply and one No LED for emergency light each fitting complete, internal ventilation system provided with concealed arial flow/cross flow fan with auto cut off system and stainless steel grill/wire (ii)Provision of standard thickness stainless steel hand rail 40mm dia inside the car cabin. (3 Sides) (k) Terminal buffers : Metal special spring/ Oil buffers as per manufacturer specification. The buffing stroke shall not be less than 200mm. (l) Door opening (Inside) : Protected by centre/ Tlescopic opening stainless steel doors with hairline finish doors with clear opening size not less than 900 x 2000mm. (m) Car & counter weight Guide : Guide rails of 'T Section Mild steel as per OEM design. Counter weight shall be cast iron as recommended by OEM. (n) Flooring : Aluminium chequered plate 5mm thick.
(o) Signals :- (i) Combined luminous hall buttons with LCD/VFD hall position indicators at all floor. (ii) LCD/VFD for car position indicator to be fitted in COP made of stainless steel. (iii) One No car operating panel with luminous buttons in car (stainless steel). (iv) Car direction indicator in car & Landing (v) Battery operated alarm bell & emergency light (rechargeable) along with suitable maintenance free battery. (This system should be separate (vi) Overload warning feature in car cabinet( Display & announcing both type). (vii) Fireman's switch one No per lift to be installed at ground Floor near landing door. (viii) Built in announcing system without hand set.02 Nos( One for lift car & ground floor landing door & one announcing system with hand set in machine room). . (ix) The interior of the car should be provided with a device that audibly indicates the floor position of lift car has reached and indicates that car entrance/exit door is open or closed. (p) Stops & Opening : 06-06 stop and one side opening (same side) at all floors. (q) Safety Device : (i) Automatic rescue devise (ARD)/Automatic landing device with maintenance free battery having suitable capacity. The batteries must have auto charging facilities. (ii) The ARD actuation time should be less than one second after failure of power supply and when ARD is operative the car should stop at the nearest floor and then automatically open
(r) Operation : Simplex, full collective automatic operation with/without attendant. (s) Machine Room : Located above the hoist way. (Details as per appendix attached) (t) Hoist-Way Constn : Existing at site, details as per Appendix attached. (u) Civil work : Necessary civil work such as making good disturbed surfaces, modification to landing space to suit to car size, necessary foundation to machine. (v) Control system shall be enclosed loop type. (w) Door shall have AC-VVVF controlled close loop operated. (x) Face plate shape shall be rectangular and stainless steel with hairline finish. (y) counter weight shall be of cast iron as recommended by OEM. (z) One number wall mounted type telephone instrument of make Crompton Greaves / Beetel/ OEM own make installed inside of car cabin along with fixing arrangement and telephone cable of suitable size from car cabin to machine room run along with trailing cable. The telephone instrument shall be connected in the telephone DB installed in the machine room. (za) One number electrically operated siren, operating voltage 240 volts having audible range of 0.5 Km of make Kheraj, Model No SS050 alongwith one number inverter unit of suitable capacity of not less than 0.5KVA comprising of maintenance free battery connected with charging system including a separate switch/push button inside of car panel and electric wiring circuit upto the machine room. The siren shall be installed over the building at appropriate place and to be operated from inside the car
Supply, install, testing & commissioning of 1000Kg goods lift suitable to serve G+09 upper floors with AC variable voltage & variable frequency (VVVF drive) drive, gear less complete with all standard accessories, simplex collective automatic & manual dual controlled operation with/without attendant, automatic centre opening doors with VVVF door drive (electric motor driven mechanism), sliding stainless steel doors, automatic rescue device (ARD) system, 3D infra red sensor in full height of door & built in announcing system without hand set (03 Nos, one each in car, machine room & near Ground floor landing door) complete all as specified and directed. Note :Lift OEM to submit detailed specification/design parameters, construction drgs of all components of lifts as per IS-14665/NBC 2016 for approval of accepting officer before execution of work. GE & Engr-in-charge shall ensure that detail drg shall be forwarded to this HQ for approval with recommendation with in one month of issue of WO.
(a) Type of Lifts : Goods. (b) Load capacity : 1000 Kgs. (c) Speed : 0.5 mtr/sec with single speed motor. (d) Power Supply : 415 volts, 3 phase AC, 50 Hz. (e) Type of Drive : AC variable voltage & variable frequency drive (f) Type of Machine : Low inertia gearless permanent magnet synchronous motor, directly coupled horizontal traction machine. (g) Car size (Inside) : Not less than 2.52 Sqm. (h) Car door and landing door at all floor : Automatic centre / Telescopic opening with VVVF door drive, opening size not less than 1200mm x 2000mm, sliding type, fabricated by stainless steel sheet not less than 16 gauge having hairline finish (N-304).
(j) Car enclosure :- (i) Manufactured with stainless steel sheet not less than 16 gauge with hair line finish (N-304), having stainless steel false ceiling with hairline finish, internal lighting arrangement with 04 Nos LED light fitting for commercial supply and one No LED for emergency light each fitting complete, internal ventilation system provided with concealed arial flow/cross flow fan with auto cut off system and stainless steel grill/wire (ii)Provision of standard thickness stainless steel hand rail 40mm dia inside the car cabin. (3 Sides) (k) Terminal buffers : Metal special spring/ Oil buffers as per manufacturer specification. The buffing stroke shall not be less than 200mm. (l) Door opening (Inside) : Protected by centre/ Telescopic opening stainless steel doors with hairline finish doors with clear opening size not less than 1200 x 2000mm. (m) Car & counter weight Guide : Guide rails of 'T Section Mild steel as per OEM design. Counter weight shall be cast iron as recommended by OEM. (n) Flooring : Aluminium chequered plate 5mm thick.
(o) Signals :- (i) Combined luminous hall buttons with LCD/VFD hall position indicators at all floor. (ii) LCD/VFD for car position indicator to be fitted in COP made of stainless steel. (iii) One No car operating panel with luminous buttons in car (stainless steel). (iv) Car direction indicator in car & Landing (v) Battery operated alarm bell & emergency light (rechargeable) along with suitable maintenance free battery. (This system should be separate (vi) Overload warning feature in car cabinet( Display & announcing both type). (vii) Fireman's switch one No per lift to be installed at ground Floor near landing door. (viii) Built in announcing system without hand set.02 Nos( One for lift car & ground floor landing door & one announcing system with hand set in machine room). . (ix) The interior of the car should be provided with a device that audibly indicates the floor position of lift car has reached and indicates that car entrance/exit door is open or closed. (p) Stops & Opening : 10-10 stop and one side opening (same side) at all floors. (q) Safety Device : (i) Automatic rescue devise (ARD)/Automatic landing device with maintenance free battery having suitable capacity. The batteries must have auto charging facilities. (ii) The ARD actuation time should be less than one second after failure of power supply and when ARD is operative the car should stop at the nearest floor and then automatically open
(r) Operation : Simplex, full collective automatic operation with/without attendant. (s) Machine Room : Located above the hoist way. (Details as per appendix attached) (t) Hoist-Way Constn : Existing at site, details as per Appendix attached. (u) Civil work : Necessary civil work such as making good disturbed surfaces, modification to landing space to suit to car size, necessary foundation to machine. (v) Control system shall be enclosed loop type. (w) Door shall have AC-VVVF controlled close loop operated. (x) Face plate shape shall be rectangular and stainless steel with hairline finish. (y) counter weight shall be of cast iron as recommended by OEM. (z) One number wall mounted type telephone instrument of make Crompton Greaves / Beetel/ OEM own make installed inside of car cabin along with fixing arrangement and telephone cable of suitable size from car cabin to machine room run along with trailing cable. The telephone instrument shall be connected in the telephone DB installed in the machine room. (za) One number electrically operated siren, operating voltage 240 volts having audible range of 0.5 Km of make Kheraj, Model No SS050 alongwith one number inverter unit of suitable capacity of not less than 0.5KVA comprising of maintenance free battery connected with charging system including a separate switch/push button inside of car panel and electric wiring circuit upto the machine room. The siren shall be installed over the building at appropriate place and to be operated from inside the car
Supply, install, testing & commissioning of 1000Kg goods lift suitable to serve G+06 upper floors with AC variable voltage & variable frequency (VVVF drive) drive, gear less complete with all standard accessories, simplex collective automatic & manual dual controlled operation with/without attendant, automatic centre opening doors with VVVF door drive (electric motor driven mechanism), sliding stainless steel doors, automatic rescue device (ARD) system, 3D infra red sensor in full height of door & built in announcing system without hand set (03 Nos, one each in car, machine room & near Ground floor landing door) complete all as specified and directed. Note :Lift OEM to submit detailed specification/design parameters, construction drgs of all components of lifts as per IS-14665/NBC 2016 for approval of accepting officer before execution of work. GE & Engr-in-charge shall ensure that detail drg shall be forwarded to this HQ for approval with recommendation with in one month of issue of WO.
(a) Type of Lifts : Goods. (b) Load capacity : 1000 Kgs. (c) Speed : 0.5 mtr/sec with single speed motor. (d) Power Supply : 415 volts, 3 phase AC, 50 Hz. (e) Type of Drive : AC variable voltage & variable frequency drive (f) Type of Machine : Low inertia gearless permanent magnet synchronous motor, directly coupled horizontal traction machine. (g) Car size (Inside) : Not less than 2.52 Sqm. (h) Car door and landing door at all floor : Automatic centre / Telescopic opening with VVVF door drive, opening size not less than 1200mm x 2000mm, sliding type, fabricated by stainless steel sheet not less than 16 gauge having hairline finish (N-304).
(j) Car enclosure :- (i) Manufactured with stainless steel sheet not less than 16 gauge with hair line finish (N-304), having stainless steel false ceiling with hairline finish, internal lighting arrangement with 04 Nos LED light fitting for commercial supply and one No LED for emergency light each fitting complete, internal ventilation system provided with concealed arial flow/cross flow fan with auto cut off system and stainless steel grill/wire (ii)Provision of standard thickness stainless steel hand rail 40mm dia inside the car cabin. (3 Sides) (k) Terminal buffers : Metal special spring/ Oil buffers as per manufacturer specification. The buffing stroke shall not be less than 200mm. (l) Door opening (Inside) : Protected by centre/ Telescopic opening stainless steel doors with hairline finish doors with clear opening size not less than 1200 x 2000mm. (m) Car & counter weight Guide : Guide rails of 'T Section Mild steel as per OEM design. Counter weight shall be cast iron as recommended by OEM. (n) Flooring : Aluminium chequered plate 5mm thick.
(o) Signals :- (i) Combined luminous hall buttons with LCD/VFD hall position indicators at all floor. (ii) LCD/VFD for car position indicator to be fitted in COP made of stainless steel. (iii) One No car operating panel with luminous buttons in car (stainless steel). (iv) Car direction indicator in car & Landing (v) Battery operated alarm bell & emergency light (rechargeable) along with suitable maintenance free battery. (This system should be separate (vi) Overload warning feature in car cabinet( Display & announcing both type). (vii) Fireman's switch one No per lift to be installed at ground Floor near landing door. (viii) Built in announcing system without hand set.02 Nos( One for lift car & ground floor landing door & one announcing system with hand set in machine room). . (ix) The interior of the car should be provided with a device that audibly indicates the floor position of lift car has reached and indicates that car entrance/exit door is open or closed. (p) Stops & Opening : 07-07 stop and one side opening (same side) at all floors. (q) Safety Device : (i) Automatic rescue devise (ARD)/Automatic landing device with maintenance free battery having suitable capacity. The batteries must have auto charging facilities. (ii) The ARD actuation time should be less than one second after failure of power supply and when ARD is operative the car should stop at the nearest floor and then automatically open
(r) Operation : Simplex, full collective automatic operation with/without attendant. (s) Machine Room : Located above the hoist way. (Details as per appendix attached) (t) Hoist-Way Constn : Existing at site, details as per Appendix attached. (u) Civil work : Necessary civil work such as making good disturbed surfaces, modification to landing space to suit to car size, necessary foundation to machine. (v) Control system shall be enclosed loop type. (w) Door shall have AC-VVVF controlled close loop operated. (x) Face plate shape shall be rectangular and stainless steel with hairline finish. (y) counter weight shall be of cast iron as recommended by OEM. (z) One number wall mounted type telephone instrument of make Crompton Greaves / Beetel/ OEM own make installed inside of car cabin along with fixing arrangement and telephone cable of suitable size from car cabin to machine room run along with trailing cable. The telephone instrument shall be connected in the telephone DB installed in the machine room. (za) One number electrically operated siren, operating voltage 240 volts having audible range of 0.5 Km of make Kheraj, Model No SS050 alongwith one number inverter unit of suitable capacity of not less than 0.5KVA comprising of maintenance free battery connected with charging system including a separate switch/push button inside of car panel and electric wiring circuit upto the machine room. The siren shall be installed over the building at appropriate place and to be operated from inside the car
Supply, install, testing & commissioning of 1000Kg goods lift suitable to serve G+05 upper floors with AC variable voltage & variable frequency (VVVF drive) drive, gear less complete with all standard accessories, simplex collective automatic & manual dual controlled operation with/without attendant, automatic centre opening doors with VVVF door drive (electric motor driven mechanism), sliding stainless steel doors, automatic rescue device (ARD) system, 3D infra red sensor in full height of door & built in announcing system without hand set (03 Nos, one each in car, machine room & near Ground floor landing door) complete all as specified and directed. Note :Lift OEM to submit detailed specification/design parameters, construction drgs of all components of lifts as per IS-14665/NBC 2016 for approval of accepting officer before execution of work. GE & Engr-in-charge shall ensure that detail drg shall be forwarded to this HQ for approval with recommendation with in one month of issue of WO.
(a) Type of Lifts : Goods. (b) Load capacity : 1000 Kgs. (c) Speed : 0.5 mtr/sec with single speed motor. (d) Power Supply : 415 volts, 3 phase AC, 50 Hz. (e) Type of Drive : AC variable voltage & variable frequency drive (f) Type of Machine : Low inertia gearless permanent magnet synchronous motor, directly coupled horizontal traction machine. (g) Car size (Inside) : Not less than 2.52 Sqm. (h) Car door and landing door at all floor : Automatic centre / Telescopic opening with VVVF door drive, opening size not less than 1200mm x 2000mm, sliding type, fabricated by stainless steel sheet not less than 16 gauge having hairline finish (N-304).
(j) Car enclosure :- (i) Manufactured with stainless steel sheet not less than 16 gauge with hair line finish (N-304), having stainless steel false ceiling with hairline finish, internal lighting arrangement with 04 Nos LED light fitting for commercial supply and one No LED for emergency light each fitting complete, internal ventilation system provided with concealed arial flow/cross flow fan with auto cut off system and stainless steel grill/wire (ii)Provision of standard thickness stainless steel hand rail 40mm dia inside the car cabin. (3 Sides) (k) Terminal buffers : Metal special spring/ Oil buffers as per manufacturer specification. The buffing stroke shall not be less than 200mm. (l) Door opening (Inside) : Protected by centre/ Telescopic opening stainless steel doors with hairline finish doors with clear opening size not less than 1200 x 2000mm. (m) Car & counter weight Guide : Guide rails of 'T Section Mild steel as per OEM design. Counter weight shall be cast iron as recommended by OEM. (n) Flooring : Aluminium chequered plate 5mm thick.
(o) Signals :- (i) Combined luminous hall buttons with LCD/VFD hall position indicators at all floor. (ii) LCD/VFD for car position indicator to be fitted in COP made of stainless steel. (iii) One No car operating panel with luminous buttons in car (stainless steel). (iv) Car direction indicator in car & Landing (v) Battery operated alarm bell & emergency light (rechargeable) along with suitable maintenance free battery. (This system should be separate (vi) Overload warning feature in car cabinet( Display & announcing both type). (vii) Fireman's switch one No per lift to be installed at ground Floor near landing door. (viii) Built in announcing system without hand set.02 Nos( One for lift car & ground floor landing door & one announcing system with hand set in machine room). . (ix) The interior of the car should be provided with a device that audibly indicates the floor position of lift car has reached and indicates that car entrance/exit door is open or closed. (p) Stops & Opening : 06-06 stop and one side opening (same side) at all floors. (q) Safety Device : (i) Automatic rescue devise (ARD)/Automatic landing device with maintenance free battery having suitable capacity. The batteries must have auto charging facilities. (ii) The ARD actuation time should be less than one second after failure of power supply and when ARD is operative the car should stop at the nearest floor and then automatically open
(r) Operation : Simplex, full collective automatic operation with/without attendant. (s) Machine Room : Located above the hoist way. (Details as per appendix attached) (t) Hoist-Way Constn : Existing at site, details as per Appendix attached. (u) Civil work : Necessary civil work such as making good disturbed surfaces, modification to landing space to suit to car size, necessary foundation to machine. (v) Control system shall be enclosed loop type. (w) Door shall have AC-VVVF controlled close loop operated. (x) Face plate shape shall be rectangular and stainless steel with hairline finish. (y) counter weight shall be of cast iron as recommended by OEM. (z) One number wall mounted type telephone instrument of make Crompton Greaves / Beetel/ OEM own make installed inside of car cabin along with fixing arrangement and telephone cable of suitable size from car cabin to machine room run along with trailing cable. The telephone instrument shall be connected in the telephone DB installed in the machine room. (za) One number electrically operated siren, operating voltage 240 volts having audible range of 0.5 Km of make Kheraj, Model No SS050 alongwith one number inverter unit of suitable capacity of not less than 0.5KVA comprising of maintenance free battery connected with charging system including a separate switch/push button inside of car panel and electric wiring circuit upto the machine room. The siren shall be installed over the building at appropriate place and to be operated from inside the car
SOOD ASSOCIATES PVT LTD
AADHISHIVAM ENGINEERING CONSTRUCTION LLP
S.S.NATARAJAN AND CO
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.12 MB
801460TENDER.pdf
Tender Documents • 24.48 MB
WKDRGS.pdf
Additional Documents • 13.16 MB
TDDRGS.pdf
Additional Documents • 6.88 MB
BOQ_668543.xls
BOQ • 0.39 MB
Download all tender documents and submit your bid