Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹8.7 CrAccepted-AOC | ₹8.7 Cr | L1 | Accepted-AOC BEING LOWEST AND REASONABLE TENDER |
| 2 | L2₹9.4 Cr+₹76.4 L (8.81%)Rejected-Finance | ₹9.4 Cr+₹76.4 L (8.81%) | L2 | Rejected-Finance NOT BEING THE LOWEST |
| 3 | L3₹9.5 Cr+₹77.4 L (8.92%)Rejected-Finance NOT SPECIFIED | ₹9.5 Cr+₹77.4 L (8.92%) | L3 | Rejected-Finance NOT BEING THE LOWEST |
| 4 | L4₹10.1 Cr+₹1.4 Cr (16.6%)Rejected-Finance L 87 STREET NO 7C MAHIPALPUR EXTENSION NEW DELHI 110037 | NEW DELHI | NEW DELHI | DELHI | 110037 | ₹10.1 Cr+₹1.4 Cr (16.6%) | L4 | Rejected-Finance NOT BEING THE LOWEST |
| 5 | L5₹10.2 Cr+₹1.5 Cr (17.4%)Rejected-Finance FLAT NO 03 PANCHAVATI BUILDING ADARSH NAGAR CHICALIM GOA 403711 | SOUTH GOA | GOA | 403711 | ₹10.2 Cr+₹1.5 Cr (17.4%) | L5 | Rejected-Finance NOT BEING THE LOWEST |
Tender Value
₹9.7 Cr
EMD Value
₹8.1 L
Closing Date
24 Feb 2021, 6:00 pmClosed
Cheif Engineer (Navy) Mumbai
CE ( Navy) Mumbai 26, Assayee Buildings Colaba Mumbai-400005
PROVISION OF 40 INLIVING OTM ACCOMODATION FOR OFFICER MESS AT HANSA
2020_MES_359692_1
87850/E8
Open Tender
Civil Works
Works
540 days
GOA
As per tender documents
8 documents required · 8 mandatory
₹3,000
GE (P) Vasco
₹8.1 L
23 Mar 2021
10 Jul 2020
26 Feb 2021
10 Jul 2020
24 Feb 2021
15 Jan 2021
11 Jul 2020 - 25 Jul 2020
Amount
Total amount of Sch 'A' Part-I (BUILDINGS & STRUCTURES) brought forward from Serial Page No.32(R)
Total amount of Sch 'A' Part-II ( EXCAVATION , EARTH WORK & SITE CLEARANCE ) brought forward from Serial Page No. 33(R )
Total amount of Sch 'A' Part-III (INTERNAL WATER SUPPLY & HOT WATER SUPPLY ) brought forward from Serial Page No.35
Total amount of Sch 'A' Part-IV ( INTERNAL ELECTRIFICATION ) brought forward from Serial Page No.38(R )
Total amount of Sch 'A' Part-V (LIFT)brought forward from Serial Page No 40(R )
Total amount of Sch 'A' Part-VI (FIRE FIGHTING SYSTEM )brought forward from Serial Page No. 43(R )
Total amount of Sch 'A' Part-VII (LIGHTNING PROTECTION ) brought forward from Serial Page No. 44(R )
Total amount of Sch 'A' Part-VIII (EXTERNAL ELECTRIFICATION) brought forward from Serial Page No. 47 (R )
Total amount of Sch 'A' Part-IX ( ROAD / PATHS / HARD STANDING ) brought forward from Serial Page No. 49(R )
Total amount of Sch 'A' Part-X ( SEWAGE DISPOSAL ) brought forward from Serial Page No.51(R )
Total amount of Sch 'A' Part-XI ( AREA DRAINAGE ) ) brought forward from Serial Page No.52(R )
Total amount of Sch 'A' Part-XII ( EXTERNAL WATER SUPPLY ) brought forward from Serial Page No. 53
Total amount of Sch 'A' Part-XIII ( DEMOLITION ) brought forward from Serial Page No.54
Total amount of Sch 'A' Part-XIV ( CHAIN LINK FENCING & GATE ) brought forward from Serial Page No.54-A
Sch 'A' Part- XV - MISCELLANEOUS ITEMS (Note : This schedule is not pre priced by MES and the pre priced rate indicated as "Rs. 0.00" under Col.-5 signifies this fact only.)
INTERNAL AND HOT WATER SUPPLY : S&F wall mixer with over head shower CP fancy type 15 mm all as specified and directed. Make : Jaquar, Crabtree, Marc
S&F CP wash basin mixer for mixing hot & cold water of size 15mm complete all as specified and directed.
S&F Closed Stationary Storage type water heater geyser, 5 star rating, operating on 230 volt AC, inner tank made out of mild steel,outer body made out of PVC ,coil wattage 2000 W , of capacity 25 lit ,including earth leakage circuit breaker, nut bolt & washer , Make : HAVELLS model no-PURO PLUS or equvivalant of CROMPTON /RACOLD/BAJAJ
S & F PVC Connections 15mm size with PTMT nuts of length 450 mm for hot water
S & F PVC Connections 15mm size with PTMT nuts of length 450 mm for cold water
INTERNAL ELECTRIFICATION, TV POINT & SPECIAL ITEMS : S &F modular AC Box sheet metal with socket 3 pin, suitable for 20 Amps flush type universal including 16 amp c series MCB protected.(For Geyesr) Make: Havells/ Legrand/ Anchor/ Leader
S &F LED tube light fittings decorative ultra slim linear fixture with extrudedalluminium heat sink envioromentel friendly Energy efficient ready to use pack ,1x18/20 Watt ,4 feet,surface mounting type extruded pvc, snap on installers and domestic electronic Driver ,connector block ect.with all assoceries intenally prewired & including coneecting up with 2 core flexible cppper conductor cable with suitable size & suitable for and mounting clamps PVC squre box 75x75mm - 2 nos etc. Make-WIPRO /HAVELLS /JAQUAR /PHILLIPS
S &F LED tube light fittings decorative ultra slim linear fixture with extruded alluminium heat sink envioromentel friendly Energy efficient ready to use pack ,1x10 Watt ,2 feet,surface mounting type extruded pvc, snap on installers and domestic electronic Driver ,connector block ect.with all assoceries intenally prewired & including coneecting up with 2 core flexible cppper conductor cable with sutable size & suitable for and mounting clamps PVC squre box 75x75mm - 2 nosetc. Make- WIPRO /HAVELLS /JAQUAR /PHILLIPS
S &F LED tube light fittings decorative ultra slim linear fixture with extrudedalluminium heat sink envioromentel friendly Energy efficient ready to use pack ,1x8/9 Watt ( for mirror light) ,2 feet,surface mounting type extruded pvc, snap on installers and domestic electronic Driver ,connector block ect.with all assoceries intenallt prewired & includingconeecting up with 2 core flexible cppper conductor cable with sutable size & suitable for and mounting clamps PVC squre box 75x75mm - 2 nosetc. make- WIPRO /HAVELLS /JAQUAR /PHILLIPS
S & F LED Security/Street light fittings 15 Watt wall mounting type extruded metal/aluminium body, and electronic LED driver, ect. with all accessories internal prewired & including connecting up with 2 core flexible cppper conductor cable with suitable size etc. Make- WIPRO /HAVELLS /JAQUAR /PHILLIPS
Fabricate,supply & fix GI pipe bracket 25mm dia- 0.9m long & 2 set of clamps made out of 30x5mm ms flat & fixed with anchor bolt suitable for 15w ssecurity light fitting
S&F Fresh air Exhaust fan of size 230 mm sweep PVC body complete with and louvers connecting up including provision of three core flexible copper wire of size 23/0.0076 from ceiling rose to exhaust fan. Make - Havells/Crompton Greaves/Bajaj
S&F Energy efficient BEE five star rated ceiling fan, 1400 mm sweep and connecting up including provision of three core flexible copper wire of size 23/0076 from ceiling rose to ceiling fan complete in all respect all as specified and directed. ( for Tech Building & Adm Building ) -Make : Crompton Greaves/ Bajaj/Orient
S&F MCCB DB VERTICAL TYPE suitable for 250 amps MCCB as incommer made of sheet steel , powder painted with NUTRAL bus bar 200 A, neutral link, IP-43-IK09 protection grade , 415Volts TPN with 8 way Double door , L&T CAT NO-DBVTH008DD/ LEGRAND / schneider/ ABB
S&F MCB TP 415 Volts, 'C' series, breaking capacity 10 KA of rating 63Amps
S&F MCB TPN 415 Volts, 'C' series, breaking capacity 10 KA of rating 63Amps
S&F MCB TPN 415 Volts, 'C' series, breaking capacity 10 KA of rating 32 Amps ( for commen lighting DB)
S&F MCB SPN 240 Volts, 'C' series, breaking capacity 10 KA of rating 6-32Amps
S&F MCB SP 6-32 Amps 'C' series, breaking capacity 10 KA of rating
S&F MCCB 200 A 25 KA,4 POLE ,thermal magnetic relese, Ics=100% Icu
Supply & Fix elecronic energy meter,temper proof,operated on 240v AC ,single phase, 10amps to 60 amps, base mounting meter, backlit LCD display with user friendly legend, accuracy class-1, MD recording, revenue protection ( in case of wrong electric connection),capability to disply & communicate ( in case of absence of main supply), deficiency metering with either phase/netral current, IP 51 protection ,as per IS13779, without optical port,complete including pvc/acrylic meter box & wooden board, L&T model no- EM101 & Cat no- WM101BC7DDHBOX of L&T or equivalant of secure
Supply and lay Co-Axial Cable RG-6 dia drawn through conduit
Supply and lay 2 pair Telephone Cable copper 0.5 mm dia ATC drawn through conduit.
S & F RJ 11 Telephone socket
S &F TV Socket
S &F modular AC Box sheet metal with socket 3 pin, suitable for 20 Amps flush type universal including 20 amp c series MCB protected.
S &F MCCB TPN 200 Amps , 415Volts, 25KA ,4 POLE L&T cat no-CM90634OONO / LEGRAND / schneider/ ABB
FIRE FIGHTING SYSTEM : Supply and lay control cable PVC insulated PVC sheathed galvanised steel strip or wire armoured with stranded copper conductor of size 1.5 sqmm 2 core 1100 Volts grade
Supply, Installation, test and Commissioning CPRI APPROVED factory fabricated, out door type, LT panel board ,made out of 3.15 mm thick CRCA Sheet with projected Globe roof for rain water protection Dust and Vermin Proof , Double door with both side opening including Neoprene Rubber Gasket, suitable for 440 Volt 3 Phase 4 Wire System, including Danger Plate, Earthing Strip Point and Ventilation Louvers at Rear Side, Bottom detachable Gland Plate complete with suitable size Zinc Chromium Plated Nuts, Bolts and Washers, etc. and embedded with 50X50X6mm Mild Steel Angle Iron Frame and 750 mm above the Normal Ground Level complete with internal connection with suitable size of cable, cable lugs and cable glands PCC Foundation in Cement Concrete 1:3:6 (20 mm Graded Stone Aggregate) and Testing after Installation including complete all as specified and comprising of the following :–Make of MCCB/MCB -MDS/LEGRAND/L&T/HEGGER ( main water supply pump )
Supply and fix Air release valve 80mm Dia ,PN 1.6
Supply and fix Valve, globe confirming to IS 9338, 80 mm size PN 1.6
Supply install test and commissiong of centrifugal pump set , electric driven complete with all accessories suitable for pumping water 900 LPM discharge at 36 m head coupled with suitable size of electric motor AC 3 phase ,50Hz including supply and fixing the items, such as , necessary connection from starter to motor terminal using proper size of copper cable including ,connection of suction pipe from pump to foot valve, delivery pipe connected to the raising mains of the over head rservoir by means of suitable joints painting the suction and delivery pipe with super enamel paint over a coat of primer as per standared code of colour including MS base plate complete complete all as specified and directed.Note : Suction and delivery pipes shall be measured and paid under appropriate items ( Booster pump for building)
Note for item no 17.05 - Energy Efficient Motors-Motors shall comply with following a. All permanently wired poly phase motors of 0.375kW or more serving the building and expected to operate more than 1500 hours per year and all permanently wired poly phase motors of 50kW or more serving the building and expected to operate more than 500 hours per year shall have a minimum acceptable nominal full load motor efficiency not less than IS 12615 for energy efficient motors b. Motors of horsepower differing from those listed in the table shall have efficiency greater than that of the next listed kW motor 0.64% c. Motor horse power rating shall not exceed 20% of the calculated maximum load being served, d. Motor nameplate shall list the nominal full- load motor efficiencies and the full load power factor e. Motor users should insist on proper rewinding practices for any rewound motors. If the proper rewinding practice can not be assured, the damaged motor should be replaced with a new, efficient one rather than suffer the significant efficiency penalty associated with typical rewind practices f. Certificates shall be obtained and kept on record indicating the motor efficiency. Whenever a motor is rewound, Appropriate measures shall be taken so that the core characteristics of the motor is not lost due to thermal and mechanical stress during removal of damaged parts after rewinding a new efficiency test shall be performed and a similar record shall be maintained
Standby Power Supply (DG Set)
(a) Supplying, installing, testing and commissioning, factory assembled silent Diesel Engine driven generator set, fully wired alternator AC to give an out put of 30 KVA continuously rating at a power factor 0.8 lagging, 3 phase 4 wire, 415 volts 50 Hz ± 1% supply, 1500RPM, directly coupled with diesel engine liquid cooled mounted on common base frame complete with floor mounting fuel tank (service tank) of adequate capacity with fuel line & accessories, PCC foundation work as per manufacturer's instructions, vibration damper pads, control panel & other accessories etc and comprising of following.
(b) Diesel Engine: Liquid cooled turbo charged with after cooler to deliver suitable BHP at 1500RPM under NTP conditions of BS 5514 and conforming to IS 10002, DIN 6271 & ISO 3046 with an overload capacity of 10% for one hour in any 12 hours continuous operation with the following accessories:. Diesel engine of rated speed at full load electric start developing with system with radiator and including electronic governor control of class A1, engine control panel, lub oil pump, water pump, fuel tank, exhaust pipe with silencer and suitable for electric start with batteries of adequate capacity and suitable for alternator of specified capacity complete with fly wheel direct/flexible coupling and coupling guard complete. Make: Kirloskar/ashok leyland/cummins
(a) Radiator with blower fan or heat exchanger with guard. (b) Pipe coupling for engine cooling system piping. (c ) Corrosion inhibitor coolant (d) Paper element filters (i) Fuel filter (ii) Lube oil filter (iii) By pass (e) Fly wheel housing and fly wheel to suit alternator. (f) Engine bearing mechanism in fly wheel housing. (g) Shut off coil with safeties for LLOP/HWT/over speed. (h) Dry type air cleaners and vacuum indicators. (j) Residential silencers. (k) Stainless steel exhaust flexible bellows. (l) Motor driven priming pump. (m) Battery charging alternator.
(n) Exhaust piping made out of STIC C class, MS pipe inclusive of all accessories and hardware, necessary supports scaffolding as per manufacturer's recommendations to sustain back pressure with rain cap. (o) Mineral wool insulation 2 inch thick suitable for 400 degree Celsius temperature cladded with aluminium sheet o 30 gauge for the entire length of exhaust pipe. (p) First fill of oil, coolant and diesel during commissioning and 12 hours testing. (q) Interconnecting copper cabling of adequate capacity batteries control. (r ) Fuel pipe class STIC 1" /1.5" /2" dia - 01 lot (s) Self starter 12 volts DC. (t) Electric operated electronic governor. (u) Fuel injection pump.
(v) Electronic instrument panel, complete with all accessories as per manufacturer's specifications displaying the following:- (i) 12 V Battery. (ii) Water temperature. (iii) lubricating oil pressure. (iv) Engine speed -1500Rpm (v) Engine hours (vi) Frequency. (vii) Voltage. (w) Safety control (Trip and indication). (i) High water temperature (ii) Low lube oil temperature (iii) Overspeed stop
(x) Base frame: Sturdy, fabricated welded construction, channel iron base frame (duly painted) for mounting engine and alternator as per manufacturer's design alonwith AVM pads. (y) Battery:-24 volts(02x12vBattery) DC, 180AH, maintenance free battery conforming to IS:14257 with leads & terminals (Make- Excide/Amron). (z) Fuel tank: 10 hrs. full load diesel storage capacity fuel tank with mounting brackets factory made of 5mm thick HR/MS sheet with level indicator fuel inlet, fuel outlet, air vent, drain plug, in let arrangement for diesel filling fro exterior canopy (without opening its panel) etc complete all as specified and directed.
(c) Alternator: Suitable rated 30 KVA, 0.8 pf , 415 volts, 3 phase, 4 wire, 50 Hz at 1500 RPM, self excited and self regulated with AVR brushles, screen protected, drip proof , insulation class-H, IP -23, voltage regulation grade - VG 3 self ventilated and conforming to BS: 5000 / IS: 4722 suitable for engine as mentioned here-in before, conformig to IS: 13364(part-1) Make: stampford/crompten/kirloskar
(d) Acoustic Enclosure:- M & L for acoustic enclosure for the above 30 KVA DG set to reduce noise level to 75 dB measured at 1.0 meter distance for audible frequencies as per guide of Central Pollution Control Board and size 3490 x 1340 x 1885mm and manufacturer's specification and comprising of following from authorised GOEMs of Gen Set manufacturer's specified :-
(i) Sound insulation : 100mm thick Rock wool (Density 64 Kg/Cum). (ii) Outer body : 1.6mm thick CRCA (iii) Door : 1.6mm thick CRCA (iv) Base frame : ISMC 300 (v) Inside illumination : 1 No.- 1 x 18 watt FTL fitting of make Phillips/ Bajaj/ Crompton.
(e) AMF Control panel:- Factory fabricated cubicle type, free standing, floor mounted, indoor type, IP-52, AMF control panel, provided with removable rear panels & hinged front panel for easy accessibility, fabricated out of not less than 2.0mm thick CRCA sheet including two coats of powder coated paint over a coat of red oxide primer etc and comprising of following:
(f) AMF control circuit with 4 pole MCCB 63 Amps - 2 nos, with ultimate breaking capacity Icu-36 KA at 415 volts and microprocessor release conforming to IEC 60947 Part-I with breaking capacity Ics=Icu at 415 volts , thermal overload setting 70% to 100%, short circuit setting 5 to 10 times-02 Nos. for main supply & DG set supply with HRC back up fuse complete with all DC control relays/ Line voltage monitor (LVM) as per OEM specifications incorporating motorised stored energy operating Engine start, stop, three attempt starting facility and failure to start etc.
(g) Digital load manager : Three phase 4 wire indicating V,I,PF, KVA, KW, F of Enercon make with serial communication port model No.EM6400 with class 1.0 accuracy meter or equivalent make suitable rating of CT per phase- one No. (iii) Indication lamp R, Y, B with 3 Nos. of 2A HRC fuses-10 sets. (iv) Bottom gland plate for incoming and outgoing cables. (v) Circuit diagram plate.
(h) Civil works:- All civil works related to foundation, installation of panel and equipment & depth of foundation shall be minimum 300mm with ant vibration pads, or as recommended by manufacturers. Cable from DG set to AMF panel, AMF panel to main panel will be measured under relevant schedule. Note:-The fuel for final testing of 12 hours shall be supplied by the contractor and cost deemed to be included in the above offer. All other necessary equipments like resistance load strip heater of suitable capacity/rating and any other items required for final testing shall be provided by the contractor without any extra cost to department.
Supply, Installation, test and Commissioning CPRI approved factory fabricated, out door type, LT Pannel Board made out of 3.15 mm thick CRCA Sheet with projected globe roof for rain water protection dust and Vermin Proof , Double door with both side opening including Neoprene Rubber Gasket, suitable for 440 Volt 3 Phase 4 Wire System, including Danger Plate, Earthing Strip Point and Ventilation Louvers at Rear Side, Bottom detachable Gland Plate complete with suitable size Zinc Chromium Plated Nuts, Bolts and Washers, etc. and embedded with 50X50X6mm Mild Steel Angle Iron Frame and 750 mm above the Normal Ground Level complete with internal connection with suitable size of cable, cable lugs and cable glands PCC Foundation in Cement Concrete 1:3:6 (20 mm Graded Stone Aggregate) and Test-ing after Installation including complete all as specified and comprising of the following :–Make of MCCB/MCB -LEGRAND/L&T/Hager/SCHNEIDER
(a) MCCB 63 A 25 KA,4 POLE ,thermal magnetic relese, Ics=100% Icu & L&T cat no- SL98603OOOO /Legrand cat no-420013/schneider cat no-LV510315 - 1 no INCOMING:-
OUTGOINGS:-
(a) MCCB 32 A 25 KA,3 POLE ,thermal magnetic relese, Ics=100% Icu & L&T /Legrand /schneider - 5 no (Lift, Tarrace pump,W/s pump,commen lighting DB & spare)
(d) Aluminum TPN bus bar 100 Amps - 01 Set
(g) LED TYPE indicator lamp 1 set (set of three for R,Y,B)
External Electrification
Boring of holes under road, pavement, hard standing by trenchless technology using ultra sounding technique and necessary machine including HDPE pipe of 150 mm dia suitable for 0.4 mpa working pressure
Supply and fix AVIATION LIGHT type,LED TYPE IP 65 protection cat no -SLE AL 54 -LDR-SEN IP65 of SURYA /BAJAJ cat no -BGAV 302 LED/PHILIPS
Supply and fix cable route indicator made of round CI disc embossed LT Cable, of size 16cm dia 6mm thick duly revited with angle of size 50x50x4mm and 60cm long including PCC 1:2:4 B1 using 20mm aggregate 15cm x 15cm x 15cm for grouting the same complete all as specified.
Supply and fix cable route indicator made of round CI disc embossed HT Cable, of size 16cm dia 6mm thick duly revited with angle of size 50x50x4mm and 60cm long including PCC 1:2:4 B2 using 20mm aggregate 15cm x 15cm x 15cm for grouting the same complete all as specified.
Supply, Installation, test and Commissioning CPRI approved factory fabricated, out door type, LT Pannel Board made out of 3.15 mm thick CRCA Sheet with projected globe roof for rain water protection dust and Vermin Proof , Double door with both side opening including Neoprene Rubber Gasket, suitable for 440 Volt 3 Phase 4 Wire System, including Danger Plate, Earthing Strip Point and Ventilation Louvers at Rear Side, Bottom detachable Gland Plate complete with suitable size Zinc Chromium Plated Nuts, Bolts and Washers, etc. and embedded with 50X50X6mm Mild Steel Angle Iron Frame and 750 mm above the Normal Ground Level complete with internal connection with suitable size of cable, cable lugs and cable glands PCC Foundation in Cement Concrete 1:3:6 (20 mm Graded Stone Aggregate) and Test-ing after Installation including complete all as specified and comprising of the following :–Make of MCCB/MCB -LEGRAND/L&T/Hager/SCHNEIDER
INCOMING:- (a)MCCB 320 A 35 KA, 4 POLE ,thermal magnetic relese, Ics=100% Icu & L&T cat no- CM94105OOQ1OG /Legrand ./schneider.- 1 no
OUTGOINGS:- (b) MCCB 200 A 35 KA,3 POLE ,thermal magnetic relese, Ics=100% Icu & L&T cat no- CM92009OON1OG /Legrand cat no-420248/schneider cat no-LV525342 - 2 no ( main building Light & AC DB) (c) MCCB 125 A 35 KA,3 POLE ,thermal magnetic relese, Ics=100% Icu L&T CAT NO-SL98653OOOO/ LEGRAND CAT NO-420086 / equivalent of ABB - 2nos ( APFC & Spare) (d) MCCB 63 A 35 KA,3 POLE ,thermal magnetic relese, Ics=100% Icu & L&T /Legrand /schneider c(Outgoing) - 2Nos ( DG Panel & spare)
[i] The Panel shall be completely Ethernet communication ready to communicate with Energy Management System & shall be Web based application in-built.
[ii] 04 Nos. of ON/OFF/trip status and operations counters as well as multi-function meters shall be wired to Ethernet Gateway part of the Panel.
(e) Elecronic energy trivactor meter,suitable for 3 phase 4 wire CT operated ,temper proof,operated on 240v AC ,three phase, 5 amps to 10 amps, base mounting meter, backlit LCD display with user friendly legend, accuracy class-0.5, MD recording, revenue protection ( in case of wrong electric connection),capability to disply & communicate ( in case of absence of main supply), with optical port,deficiency metering with either phase/netral current, IP 51 protection, as per IS13779,make of meter -L&T model no- ER300P & Cat no-WR300BC5200 of L&T or equivalant of secure
Earthing complete with galvanized steel earth plate electrode 600mm x600 mm x 6mm buried directly in ground vertically to a depth not less then 2.25 meter below normal ground level with top edge of the plate not less then 1.50 meter below normal ground level connected to galvanized earth wire 4.00mmdia by means of bolts ,nuts ,check nuts and washers complete up to and including test point made out of 40 x 6mm alum flat including earthing pit , charcoal common salt ,Earthing lead 4.00mm dia up to 7.5m, 20mm dia medium grade GI watering pipe ,G.I. protection pipe 15 mm dia up to 7.5m long,,PPC pit in PCC 1:2:4 type B-1 using 20 mm graded stone aggregate ,PCC pit cover including earth work complete all as shown in electrical plate No-5 of SSR-2014 (part-I) ( 04-int elect supply 02- special E/M item )
Earthing complete with galvanized steel earth plate electrode 600mm x600 mm x 6mm buried directly in ground vertically to a depth not less then 2.25 meter below normal ground level with top edge of the plate not less then 1.50 meter below normal ground level connected to galvanized earth 32 x 6mm GI strip by means of bolts ,nuts ,check nuts and washers complete up to and including test point made out of 40 x 6mm alum flat including earthing pit , charcoal common salt,Earthing lead 32x6 up to 7.5m, 20mm dia medium grade GI watering pipe ,PPC pit in PCC 1:2:4 type B-1 using 20 mm graded stone aggregate ,PCC pit cover including earth work complete all as shown in electrical plate No-5 of SSR-2014 (part-I) NOTE-: GI earth strip beyond 7.5 meter shall be measured and paid for separately under relevant item of schedule . (02-lift , 10-lightning protection, 06- fire fighting, 06-external water supply, 18-external electric supply, 08-DG set)
Supply, install, testing and commisioning of DIstribution transformer mounted on massoniry platform stepdown , 11KV0.433KV , Three Phase complying with IS: 1180/IEC-76(Part-1) 2014 with latest ammanmendts , Outdoor type double opper wound suitable for 50 Hz system of capacity 200 KVA, oil immersed naturally cooled delta connected on HT side and Star connected on LT side ,Vector Group Dyn11, provided with OFF load tap changer to vary secondary voltage from -7.5% to + 7.5 % in steP of 2.5 %. Losses should be confined to the limits specified as follows: :maximum allowable losses at full load (100 % ) & Half Load ( 50 % )shall not be exceeded 1.35 % & 0.93 % Respectivly as per GRlHA RATING, Percentage Impedance: 5%. Losses and Impedance are subjected to tolerance as specified in IS 1180. The transformers should be supplied with first filling of oil confirming to IS 335 .The transformer should have both side cable end box with neutral brought out complete all as directed by Engineer - in -Charge, and installation of transformer shall be carried out as per IS-10028 and comprising with the following standerd fittings/Technical specifications : -
(a) Lifting lug for transformer and tank.
(b) Earthing terminal rating and diagram plate.
(c ) Air release device.
(d) Oil filling inlet pipe with plug.
(e) Drain outlet pipe with brass gate valve.
(f) Conservator tank with oil level indicator
(g) Silica jel breather
(j) First fill of oil upto level including conservator tank with fresh new oil conforming to IS335.
(k) Type of connection Delta/Star
(l) Type of cooling: Oil and Natural Air.
(m) Vector group:DYN 11.
(n) Temperature rise over an ambient of 50 °C maximum.
(o) Cable end box on both side for HT/LT cables of suitable size.
(p) Provision of thermometer with pocket.
(q) Provision of oil and winding temperature gauge.
Supply, Installation, test and Commissioning CPRI APPROVED factory fabricated,Outdoor type, APFC capacitor bank Panel Board of size as recommended by manufactrer 40 KVAR with 6 steps ( 12.5+12.5+5+ 5+5) WITH MD-XL CAPACITOR AND MCCB AS INCOMER Automatic Power Factor Correction panel , made out of 3.15 mm thick CRCA Sheet Dust and Vermin Proof, single door with both side opening including Neoprene Rubber Gasket, suitable for 440 Volt 3 Phase 4 Wire System,The enclosure shall be pre-treated as per 11 tanks process and finished with powder coating of shade RAL 7032. , including Danger Plate, Earthing Strip Point and Ventilation Louvers at Rear Side, Bottom detachable Gland Plate complete with suitable size Zinc Chromium Plated Nuts, Bolts and Washers etc. and embedded with 50X50X6mm Mild Steel Angle Iron Frame and 750 mm above the Normal Ground Level complete with internal connection with suitable size of cable, cable lugs and cable glands PCC Foundation in Cement Concrete 1:3:6 (20mm Graded Stone Aggregate) and Testing after Installation complete all as specified .The panel shall be factory fabricated comprosing of following. Make of pannel L&T/ SCHNEIDER/ABB
INCOMER
MCCB 125 A 35 KA,4 POLE ,thermal magnetic relese, Ics=100% Icu & DN2-250D,CAT NO- CM920083OOM1OG- 1 no (Thermal Magnetic Release)
ROM+SPDR - 1 no
Auxiliary 1 c/o +TAC 1 c/o- 1 no
12.5 KVAr Capacitor feeder comprising of:- ( 2 Nos. )
40A, BUSSMANN FUSE- 6 NOS
Thyristor switching module 25kVAR, 440V,TSM,LTTSM - 2 NOS
7% Detuned Aluminium Reactor 12.5KVAr 440V LTAL,CAT NO-0712B2- 2 NOS
Ultra heavy duty capacior LTXL , BOX type oil Filled Capacitor bank 15 kVAr,sutable for 480V
Push Button ON/OFF -4nos
Indicating lamps 4 NOS
Auxiliary Contactor {2NO+2NC} 24V DC Coil Voltage MXO- 2
6A DP MCB , C CURVE 2 NOS
5 KVAr Capacitor feeder comprising of:- (3 Nos. )
16A, BUSSMANN FUSE 9 nos
Thyristor switching module 10kVAR, 440V,TSM,LTTSM
7% Detuned Aluminium Reactor 5 KVAr 440V,LTAL,CAT NO-0712B2-3 no
Ultra heavy duty capacior LTXL , BOX type oil Filled Capacitor bank 7.5 kVAr,sutable for 480V ,LTXL- 3nos
Push Button ON/OFF -6nos
Indicating lamps 6 NOS
Auxiliary Contactor {2NO+2NC} 24V DC Coil Voltage MXO- 3
6A DP MCB , C CURVE 3 NOS
Incomer Metering
APFC relay 8 stage {BLR CM – 06T MB } -1 NO [230/ 110 V, 1/5A, 50 Hz] [Transistor output + Single CT sensing + RS 485 MODBUS]
Digital Voltmeter (3Ph, Class 1) -1 NO
Digital Ameter (3Ph, Class 1, 5A) -1 NO
Metering CT --/5A, Class-1- 3 NOS
SMPS 5A, Input 230V AC Output 24V DC -1 NO
ON Delay Timer 0-10 Sec.,Coil 24V DC -1 NO
Auxiliary Contactor {4NO} with 24V DC}-3 NOS
Indicating Lamp(R,Y,B)-3 NOS
6A SP MCB-3 NOS
6A DP MCB
6A FP MCB -1 NO
8" {EBM NADI} Fan -1 NO
External Water Supply
Supply install test and commissiong of centrifugal Mono block pump set , electric driven complete with all accessories suitable for pumping water 180 LPM discharge at 40 m head coupled with suitable size of electric motor AC 3 phase ,50Hz including supply and fixing the items, such as , necessary connection from starter to motor terminal using proper size of copper cable including ,connection of suction pipe from pump to foot valve, delivery pipe connected to the raising mains of the over head rservoir by means of suitable joints painting the suction and delivery pipe with super enamel paint over a coat of primer as per standared code of colour including MS base plate complete complete all as specified and directed.Note : Suction and delivery pipes shall be measured and paid under appropriate items ( main water supply pump for building)
Note - Energy Efficient Motors-Motors shall comply with following a. All permanently wired poly phase motors of 0.375kW or more serving the building and expected to operate more than 1500 hours per year and all permanently wired poly phase motors of 50kW or more serving the building and expected to operate more than 500 hours per year shall have a minimum acceptable nominal full load motor efficiency not less than IS 12615 for energy efficient motors b. Motors of horsepower differing from those listed in the table shall have efficiency greater than that of the next listed kW motor 0.64%
c. Motor horse power rating shall not exceed 20% of the calculated maximum load being served,d. Motor nameplate shall list the nominal full- load motor efficiencies and the full load power factor e. Motor users should insist on proper rewinding practices for any rewound motors. If the proper rewinding practice can not be assured, the damaged motor should be replaced with a new, efficient one rather than suffer the significant efficiency penalty associated with typical rewind practices f. Certificates shall be obtained and kept on record indicating the motor efficiency. Whenever a motor is rewound, Appropriate measures shall be taken so that the core characteristics of the motor is not lost due to thermal and mechanical stress during removal of damaged parts after rewinding a new efficiency test shall be performed and a similar record shall be maintained
Supply and fix CI sluice valve 80 mm dia both ends flanged and drilled, bonnet wedge stuffing box. Gland trust plate, hand wheel made out of grey CI, complete valve confirming to IS 14846/2000 and its fittings suitable for hydraulic test pressure of 15 Kg/sqcm PN 1.0 ISI marked complete all as specified and directed MAKE : Kirloskar/Upadhyay/L&T
Supply and fix Brass foot valve, flanged end and drilled of size 50 mm dia ISI MARKED
Supply and fix brass double end flanged and drilled non return valve of size 50 mm dia ISI MARKED Kirloskar/Upadhyay/L&T MAKE
Supply and fix CI 'Y ' Strainer screwed end or flanged type conforming to IS, size 50 mm dia.
Supply, installation and testing of Electromagnetic water flow meter of size 50 mm dia, both ends flanged mounted in line Horizontal, full bore with PTEF line Tube SS 316 Seam suitable for operating pressure upto 10 Kg/ sqcm and flow range upto 200 LPM with SS 316 electrodes suitable coil with carbon steel coil housing complete, housed in a Aluminium Die cast weather proof IP65 enclosure alongwith Integral flow Transmitter with LCD display and push button for working on 230 Volts, 50 Hz, Single phase AC supply complete all as specified and directed.
Construction of brick masonry valve chamber of size 1000x 800x1000 mm (internal dia) suitable for 150 mm dia sluice valve with necessary earth work excavation plain cement concrete 1:4:8 using 40 mm graded stone aggregate 75 mm thick in cement mortar 1:6 15 mm thick plastering 1:6 inter nally including flooring and externally rep to 15 mm below ground level plain cement concrete 1:4:8 type B1 using 20 mm graded stone aggregate in coping MS sheet cover made out of 3 mm thick MS sheet flat iron frame and bracing with locking arrangement applying two coat of synthetic enamel paint including dismantling removing the existing damage chamber completely removal of debris to a distance not exce eding 50 mtr distance depositing where as directed by Engr - in- charge
Supply and fix Cast Iron Air Valves 25 mm with single air Outlets, conforming to IS 14845 Suitable for Cast Iron Water supply mains of size 80 mm dia.
Supply and fix brass high pressure ball valve set complete with brass rod , PVC float & fly nut complete screwed for iron pipe and necessary accessories complete all as directed.
Supply, Installation, test and Commissioning CPRI APPROVED factory fabricated, indoor type, LT panel board ,made out of 2 mm thick CRCA Sheet with projected Globe roof for rain water protection Dust and Vermin Proof , Double door with both side opening including Neoprene Rubber Gasket, suitable for 440 Volt 3 Phase 4 Wire System, including Danger Plate, Earthing Strip Point and Ventilation Louvers at Rear Side, Bottom detachable Gland Plate complete with suitable size Zinc Chromium Plated Nuts, Bolts and Washers, etc. and embedded with 50X50X6mm Mild Steel Angle Iron Frame and 750 mm above the Normal Ground Level complete with internal connection with suitable size of cable, cable lugs and cable glands PCC Foundation in Cement Concrete 1:3:6 (20 mm Graded Stone Aggregate) and Testing after Installation including complete all as specified and comprising of the following :–Make of MCCB/MCB -MDS/LEGRAND/L&T/HAGER ( main water supply pump )
INCOMING:- (a) Incoming MCCB 32 A 25 KA, 4 POLE ,thermal magnetic relese, Ics=100% Icu & L&T /Legrand /schneider -01 No
LIFT: Comprehensive maintenance and repairs of fully automatic electrically operated passenger lifts of any Make and installed capacity of 08/13 passenger to serve any nos of floor with AC variable voltage & variable frequency (VVVF drive) complete with all standard accessories, simplex collective automatic & manual dual controlled operation with/without attendant, automatic centre opening doors wth VVVF door drive (electric motor driven mechanism), sliding stainless steel door automatic rescue device (ARD) system , 3D infra red sensor in full height of door) and built in announcing system without hand set 04 Nos, one each in car, Machine room & near Ground floor landing door) comprising of all devices and accessories through 60 months ( including defect liability period of 24 months ) for all days including holidays etc after expiry of defects liability period as shown below and all as specified and dierected to GE. Note : (i)Contractor shall carryout comprehensive maintenance (routine, daily , weekly , monthly , quarterly , half yearly, yearly ) as per attached Performa and maintain all the lifts in serviceable condition 24 hrs X 365 days without any extra cost .(ii) WO for maint of lifts shall be issued by GE after completion of defect liability period for every consequent year for total period of 3 years.(ii) Final bill shall be paid after certified completion of work for each WO seperately (iii ) The Contractor shall conclude an MOU with the lift manufacturer to provide comprehensive AMC of the lift for five years from the date of commissioning/ completion. The copy of MOU shall be submitted to GE for record, giving out complete terms and conditions of the AMC before completion is issued by GE, (ii) Penalty charges @ Rs 3000 per 24 hours shall be applicable if the lift remains non functional even after 24 hours of the fault notified to contractor/ OEM rep digitally or in writing.
(a)1st year after expiry of defect liability period ( 01 No of Lift )
(b) 2nd year after completion of work of serial No 21.01 above
(c) 3rd year after completion of work of serial No 21.02 above
M/s Kishan Gopal Agarwal
United Sales Corporation
NSC Projects Pvt. Ltd.
M/s. P S REDDY
SOOD ASSOCIATES PVT LTD
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .