| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹14.1 LAccepted-AOC B 134 GANESH MURTHI NAGAR PART III COLABA MUMBAI 400 005 | MUMBAI | MAHARASHTRA | 400005 | L1 | Accepted-AOC Lowest one | |
| 2 | L2₹16.8 L+₹1.8 L (12.2%)Rejected-Finance | L2 | Rejected-Finance Other than lowest | |
| 3 | L3₹18.2 L+₹3.3 L (21.8%)Rejected-Finance NOT AVAILABLE | L3 | Rejected-Finance Other than lowest | |
| 4 | L4₹21.8 L+₹6.9 L (45.9%)Rejected-Finance | L4 | Rejected-Finance Other than lowest | |
| 5 | L5₹24.0 L+₹9.1 L (60.6%)Rejected-Finance GE W COLABA MUMBAI | CHANDRAPUR | MAHARASHTRA | 441205 | L5 | Rejected-Finance Other than lowest |
Tender Value
Refer Docs
EMD Value
₹60,000
Closing Date
24 Jul 2021, 6:00 pmClosed
GE NW NOFRA
GE NW NOFRA DR HOMI BHABHA ROAD NAVY NAGAR COLABA
REPAIRS REPLACEMENT OF EM FITTINGS FIXTURES ALONGWITH LED LIGHTS UNDER CELL NO 2 AT NOFRA AREA UNDER GE NW NOFRA COLABA MUMBAI
2021_MES_453135_2
8923
Open Tender
Electrical and Maintenance Works
Item Rate
210 days
MUMBAI
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
GE NW NOFRA
₹60,000
Yes
21 Jan 2022
6 Jul 2021
29 Jul 2021
6 Jul 2021
24 Jul 2021
12 Jul 2021
6 Jul 2021 - 17 Jul 2021
Amount
Taking down carefully aluminium point wiring (light, fan, socket or power) complete, (fittings such as switches, ceiling roses, pendants, regulators sockets etc to be measured separately) and making good disturbed surfaces of walls, floors, etc. ccomplete all as specified and directed by Engineer-in-charge.
Material and Labour for point wiring complete with 1.5 sqmm single core multistranded FRLS PVC insulated unsheathed copper conductors 1100 volts grade drawn through and including PVC non-metallic casing and caping of size not less than 25mm width, ISI marked with accessories fixed on wall/ceiling/truss etc with PVC non metallic ISI marked terminal boxes/ modular Cover plate concealed in wall including one FRLS PVC insulated & sheathed multistranded green colour copper conductor 1.5 sqmm as earth continuity conductor connected to common earth as earth dolly for :- Make of wire - Polycab / Finolex / Havells Make of casing caping - Pressfit / Precision / Polycab
(a) One light point controlled by one switch SP one way.
(b) One ceiling fan point controlled with one 5A switch
(c) One exhaust fan point controlled with one 5A switch
(d) One 3 pin socket outlet 5Amps on independant board.
(e) One 3 pin socket outlet 5Amps on same board with other switches.
(f) One bell point controlled by one bell push 5 Amps.
Material and Labour for point wiring complete with 4 sqmm single core multistranded FRLS PVC insulated unsheathed copper conductors 1100 volts grade drawn through and including PVC non-metallic casing and caping of size not less than 25mm width, ISI marked with accessories fixed on wall/ceiling/truss etc with PVC non metallic ISI marked terminal boxes / modular Cover plate concealed in wall including one FRLS PVC insulated & unsheathed multistranded green colour copper conductor 4 sqmm as earth continuity conductor connected to common earth as earth dolly. Make of wire - Polycab / Finolex / Havells Make of casing caping - Pressfit / Precision / Polycab
Supply and fix in repair Modular Switch, 6Amp, One way, 1 module. Make : LEGRAND (ARTEOR)/ ANCHOR (AVE) / GOLDMEDAL (NIXON)
Supply and fix in repair Modular blank plate, One way, 1 module. Make : LEGRAND (ARTEOR)/ ANCHOR (AVE) / GOLDMEDAL (NIXON)
Supply and fix in repair Modular Switch, 16Amp, One way, 1 module. Make : LEGRAND (ARTEOR)/ ANCHOR (AVE) / GOLDMEDAL (NIXON)
Supply and fix in repair Modular type bell push , 6Amp, 1 module. Make : LEGRAND (ARTEOR)/ ANCHOR (AVE) / GOLDMEDAL (NIXON)
Supply and fix in repair Bell electric AC 230Volt single pole musical type with ISI mark. Make - Legrand /Gold Medal / Anchor
Supply and fix in repair Modular type, electronic fan regulator (5 step), 120 Watts, 230 volts, 2 module Make- Legrand / Havells / Goldmedal
Supply and fix in repair ceiling rose surface bakelite with ISI mark, flush type with ISI mark three terminals complete all as specified and directed by Engineer-in-charge. Make - Legrand /Gold Medal / Anchor
Supply and fix in repair Modular Socket oulet, 6 Amps, 2/3 pin combined, 2 module. Make : LEGRAND (ARTEOR)/ ANCHOR (AVE) / GOLDMEDAL (NIXON)
Supply and fix in repair Modular Socket oulet, 6/16 Amps, 2/3 pin combined, 2 module. Make : LEGRAND (ARTEOR)/ ANCHOR (AVE) / GOLDMEDAL (NIXON)
Supply and fix in repair Modular white cover plate with Frame 1 Module. Make- Legrand (Arteor)/ Anchor (Ave) / Goldmedal (WEGA)
Supply and fix in repair Modular white cover plate with Frame 2 Module. Make- Legrand (Arteor)/ Anchor (Ave) / Goldmedal (WEGA)
Supply and fix in repair Modular white cover plate with Frame 3 Module. Make- Legrand (Arteor)/ Anchor (Ave) / Goldmedal (WEGA)
Supply and fix in repair Modular white cover plate with Frame 4 Module. Make- Legrand (Arteor)/ Anchor (Ave) / Goldmedal (WEGA)
Supply and fix in repair Modular white cover plate with Frame 6 Module. Make- Legrand (Arteor)/ Anchor (Ave) / Goldmedal (WEGA)
Supply and fix in repair Modular white cover plate with Frame 8 Module. Make- Legrand (Arteor)/ Anchor (Ave) / Goldmedal (WEGA)
Supply and fix in repair Modular white cover plate with Frame 12 Module. Make- Legrand (Arteor)/ Anchor (Ave) / Goldmedal (WEGA)
Supply and fix in repair Modular metal flush box 1 module. Make- Legrand (Arteor)/ Anchor (Ave) / Goldmedal (WEGA)
Supply and fix in repair Modular metal flush box 2 module. Make- Legrand (Arteor)/ Anchor (Ave) / Goldmedal (WEGA)
Supply and fix in repair Modular metal flush box 3 module. Make- Legrand (Arteor)/ Anchor (Ave) / Goldmedal (WEGA)
Supply and fix in repair Modular metal flush box 4 module. Make- Legrand (Arteor)/ Anchor (Ave) / Goldmedal (WEGA)
Supply and fix in repair Modular metal flush box 6 module. Make- Legrand (Arteor)/ Anchor (Ave) / Goldmedal (WEGA)
Supply and fix in repair Modular metal flush box 8 module. Make- Legrand (Arteor)/ Anchor (Ave) / Goldmedal (WEGA)
Supply and fix in repair Modular metal flush box 12 module. Make- Legrand (Arteor)/ Anchor (Ave) / Goldmedal (WEGA)
Supply and fix in repair Linear Box type LED T/L 20 Watt Aluminium Extruded Channel Powder coated with opaque diffuser for glare free light complete with accessories internally prewired and including connecting up with twin core twisted flexible copper conductor cable with suitable size complete all as specified and directed by Engineer-in- charge. Make- Philips / Havells/ Jaquar
Supply and fix in repair Linear Box type LED T/L 10 Watt Aluminium Extruded Channel Powder coated with opaque diffuser for glare free light complete with accessories internally prewired and including connecting up with twin core twisted flexible copper conductor cable with suitable size complete all as specified and directed by Engineer-in- charge. Make- Philips / Havells/ Jaquar
Supply and fix in repair LED lamp suitable for 14 watts, 240 volts, single phase, 50 Hzs, Lumen 1450 AC supply complete all as specified and directed by Engineer-in- charge. Make- Philips / Havells/ Jaquar
Material and Labour in repair for Lamp holder, PVC /Polycarbonate type with cord grip cap suitable for pendant fittings complete all as directed by Engineer-in-Charge. Make- Anchor / Havells/ Legrand
Supply and fix in repair Plug and Socket enclosure, in sheet metal enclosure with MCB, SP 20 Amps 240 Volts complete with metal clad socket for window type air conditioners complete all as specified and directed by Engineer-in- charge. Make - Legrand/ Schneider/ GE
Taking down old unserviceable submain cable of any size and capacity and finishing wall surfaces complete all as specified and directed by Engineer-in- charge.
Supply and fix submain wiring in repair with two single core FRLS unsheathed 1100 volts grade cable with stranded copper conductor of size 4 Sqmm in and including PVC casing caping not less than 25mm width, ISI marked including 1 single core cable with stranded copper conductor of size 4 sqmm (green colour) for earthing complete all as specified and directed by Engineer-in- charge. Note :- (i) Two runs of 4Sqmm cable, 1 run of PVC casing & caping and 1 run of 4 Sqmm cable shall be measured as 1 RM. (ii) Each submain wiring shall run in seperate PVC casing caping Make of wire - Polycab / Finolex / Havells Make of casing caping - Pressfit / Precision
Supply and fix submain wiring in repair with two single core FRLS unsheathed 1100 volts grade cable with stranded copper conductor of size 6 Sqmm in and including PVC casing caping not less than 25mm width, ISI marked including 1 single core cable with stranded copper conductor of size 6 sqmm (green colour) for earthing complete all as specified and directed by Engineer-in- charge. Note :- (i) Two runs of 6Sqmm cable, 1 run of PVC casing & caping and 1 run of 6 Sqmm cable shall be measured as 1 RM. (ii) Each submain wiring shall run in seperate PVC casing caping Make of wire - Polycab / Finolex / Havells Make of casing caping - Pressfit / Precision
Supply and fix in repair sheet metal enclosure 08 way Double door type having protection IP-42, with 200 Amps rated bus bar connecting with existing wiring circuits by providing copper pin terminals of suitable size and matching with existing surface complete all as directed and specified by Engineer in charge. Make : L&T , Legrand , Schneider
S&F in replacement of MCB SPN 63 Amps, 240 volts complete all as directed and specified by Engineer in charge. Make : L&T , Legrand , Schneider
S&F in replacement of MCB SPN 6-32 Amps, 240 volts complete all as directed and specified by Engineer in charge. Make : L&T , Legrand , Schneider
Supply and fix in repair sheet metal enclosure 12 way Double door type having protection IP-42, with 200 Amps rated bus bar connecting with existing wiring circuits by providing copper pin terminals of suitable size complete all as directed and specified by Engineer in charge. Make : L&T , Legrand , Schneider
S&F in replacement of MCB SPN 32/40 Amps, 240 volts complete all as directed and specified by Engineer in charge. Make : L&T , Legrand , Schneider
DHARMESH ENTERPRISES
SHREE JAGDISH FURNITURE CO.
NOEL ENGINEERS
SN CONSTRUCTION
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .