Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.7 LAccepted-AOC 7A BENTINCK STREET KOLKATA 700 001 | KOLKATA | KOLKATA | WEST BENGAL | 700001 | L1 | Accepted-AOC AOC ISSUED | |
| 2 | L2₹2.5 L+₹78,090 (46.0%)Rejected-Finance 2 89 BIJOYGARH JADAVPUR KOLKATA 700032 | KOLKATA | KOLKATA | WEST BENGAL | 700032 | L2 | Rejected-Finance that the bid is not L1 | |
| 3 | L3₹2.6 L+₹86,290 (50.8%)Rejected-Finance 24C GOABAGAN LANE KOLKATA 700 006 | KOLKATA | KOLKATA | WEST BENGAL | 700006 | L3 | Rejected-Finance that the bid is not L1 | |
| 4 | L4₹2.6 L+₹88,490 (52.1%)Rejected-Finance 3 C DR JAGABANDHU LANE KOLKATA 700012 | KOLKATA | KOLKATA | WEST BENGAL | 700012 | L4 | Rejected-Finance that the bid is not L1 |
| Sl No | Description | Qty | Unit | ALPHA ELECTRICALS L3 | PERFECT IMAGE SOLUTIONS L1 | S. A. ENTERPRISE L4 | A.K.ENTERPRISE L2 |
|---|---|---|---|---|---|---|---|
| 1.00 | Detectors & RI
SITC of analog addressable intelligent multisensor setector (VDS/UL/FM/ULC approved) with inbuilt optical smoke sensorsas well as additional heat detector sensor with decentralise intelligence, soft addressable photothermal type with inbuilt fault isolator as per NFPA style 7 wiring complete standard (Make Honeywell-ESSER OT MS detector IQ8 Quad with Isolator part no 802373 or as existing) (For Seminar Room, VC Room, E class Room at 4th floor & Skill lab at Ground floor) | 42 | Nos. | 4,400 ₹1,84,800 | 2,250 ₹94,500 Lowest | 4,450 ₹1,86,900 | 4,300 ₹1,80,600 |
| 2.00 | Supply, Installation, Testing & Commissioning of LED type Response Indicator. (VDS/UL/FM/ULC approved) having RED colour LED lamp including connections etc.( Make: Honey Well Esser as per existing cat no & model) (For Seminar Room, VC Room, E class Room at 4th floor & Skill lab at Ground floor) | 15 | Nos. | 650 ₹9,750 | 100 ₹1,500 Lowest | 600 ₹9,000 | 600 ₹9,000 |
| 3.00 | Cable & Conduit:-
Supply & Laying of 1.1KV grade 2Core1.5 sq.mm PVC insulated flexible FRLS shielded copper Cable (Make. Finolex/ Technoflex/ MEM/ KEI) for Looping with 20mm NB PVC conduit pipe MMS (Make Precesion) | 350 | Mtr. | 130 ₹45,500 | 125 ₹43,750 Lowest | 129 ₹45,150 | 125 ₹43,750 Lowest |
| 4.00 | Dismentling Existing Old Wiring pipe (MS type and detectors (Make Bosch) & submit the same to the departmental store or building basement as per direction of EIC in co's own carrying cost (4th floor, SSB,MC&H,Kolkata) | 1 | It. | 5,000 ₹5,000 Lowest | 10,000 ₹10,000 | 5,500 ₹5,500 | 5,000 ₹5,000 Lowest |
| 5.00 | Dismenling ,Rewiring & refixing of existing detector (without damaging the same), wire & other FDS items as required during Civil & electrical renovation work at above mentioned site as per direction of EIC | 10 | It. | 200 ₹2,000 | 1 ₹10 Lowest | 170 ₹1,700 | 150 ₹1,500 |
| 6.00 | Recommissioning & testing of whole system after completion of reparing work & submission of revised report to the EIC. | 1 | It. | 9,000 ₹9,000 | 20,000 ₹20,000 | 10,000 ₹10,000 | 8,000 ₹8,000 Lowest |
| 7.00Less cost for old dismantled materials will be deducted from gross bill for Rs 5000/- | |||||||
| 8.00T&C: All materials must be similar Make/Model of existing Fire Detection system which is already installed at above said building.All materials,Make,Cat no,specification should be approved by EIC prior to installation. | |||||||
| 9.00Special Terms and Conditions 1. It is stated that the above work place is existing COVID Hospital, In case of any mishap or accidental to any staff that deputed by the agency the whole responsibility is to be borne by the concern agency. 2. The Agency shall be responsible for provisioning of all COVID safety measures including regular sanitiziation of work places, vaccination of employees and compliance of stated directive and COVID appropriate norms. 3. All the issues related to the safety of the staffs should be taken care by the agency itself. (Defect Labilities period for 01 year after the date of completion of work) (Rate should be quotated including all taxes and duties) | |||||||
Tender Value
Refer Docs
EMD Value
₹5,000
Closing Date
19 Feb 2022, 1:00 pmClosed
EE II KNHED PW Dte.
KIT Building Annex, 4th Floor,P-16, India Exch. Place Extn., Kolkata -700073
Emergent rectification renovation of Electrical works at 4th Ground floor for setting up Geriatric Department at Super Speciality Block Building under Medical College Kolkata FDS work Reparing
2022_PWDE_364594_1
WBPWD/EEII/KNHED/ NIQ-124/21-22
Open Tender
ELECTRICAL WORKS ORG
Item Rate
21 days
Kolkata
Please refer Tender documents.
5 documents required · 5 mandatory
₹5,000
23 Sept 2026
7 Feb 2022
21 Feb 2022
9 Feb 2022
19 Feb 2022
9 Feb 2022
Amount
Detectors & RI SITC of analog addressable intelligent multisensor setector (VDS/UL/FM/ULC approved) with inbuilt optical smoke sensorsas well as additional heat detector sensor with decentralise intelligence, soft addressable photothermal type with inbuilt fault isolator as per NFPA style 7 wiring complete standard (Make Honeywell-ESSER OT MS detector IQ8 Quad with Isolator part no 802373 or as existing) (For Seminar Room, VC Room, E class Room at 4th floor & Skill lab at Ground floor)
Supply, Installation, Testing & Commissioning of LED type Response Indicator. (VDS/UL/FM/ULC approved) having RED colour LED lamp including connections etc.( Make: Honey Well Esser as per existing cat no & model) (For Seminar Room, VC Room, E class Room at 4th floor & Skill lab at Ground floor)
Cable & Conduit:- Supply & Laying of 1.1KV grade 2Core1.5 sq.mm PVC insulated flexible FRLS shielded copper Cable (Make. Finolex/ Technoflex/ MEM/ KEI) for Looping with 20mm NB PVC conduit pipe MMS (Make Precesion)
Dismentling Existing Old Wiring pipe (MS type and detectors (Make Bosch) & submit the same to the departmental store or building basement as per direction of EIC in co's own carrying cost (4th floor, SSB,MC&H,Kolkata)
Dismenling ,Rewiring & refixing of existing detector (without damaging the same), wire & other FDS items as required during Civil & electrical renovation work at above mentioned site as per direction of EIC
Recommissioning & testing of whole system after completion of reparing work & submission of revised report to the EIC.
Less cost for old dismantled materials will be deducted from gross bill for Rs 5000/-
T&C: All materials must be similar Make/Model of existing Fire Detection system which is already installed at above said building.All materials,Make,Cat no,specification should be approved by EIC prior to installation.
Special Terms and Conditions 1. It is stated that the above work place is existing COVID Hospital, In case of any mishap or accidental to any staff that deputed by the agency the whole responsibility is to be borne by the concern agency. 2. The Agency shall be responsible for provisioning of all COVID safety measures including regular sanitiziation of work places, vaccination of employees and compliance of stated directive and COVID appropriate norms. 3. All the issues related to the safety of the staffs should be taken care by the agency itself. (Defect Labilities period for 01 year after the date of completion of work) (Rate should be quotated including all taxes and duties)
A.K.ENTERPRISE
ALPHA ELECTRICALS
S. A. ENTERPRISE
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .