Loading…
Loading…
Tender Value
₹1.4 Cr
EMD Value
₹2.2 L
Closing Date
21 Jul 2025, 3:00 pmClosed
Carrying out residual work for restoration of VNGP- KGBP section of Lumding Division.
SNT-15-LMG-2025-26
SNT-15-LMG-2025-26
Open
Works - General
120 Days
Hojai, Assam
₹0
₹2.2 L
27 Jun 2025
27 Jun 2025
Supply of Low Maintenance Lead Acid Secondary Cell 2V/300 AH for S&T installation conforming to IRS:S-88/2004 or latest complete with inter cell connectors, Nuts & bolt, washer and microporous ceramic vent plug etc.
Secondary cells - Low Maintenance 2V/80 AH as per specification no. IRS: S-88/2004 or latest complete with inter cell connectors, nuts & bolts with washer, micro porous vent-cum- sealed float guide etc.
12V, 120Ah Genset battery for 40/15/5 KVA DG sets, make- Exide or similar
Under ground Railway Signalling cable 12 core x 1.5 sq. mm Copper Conductor PVC insulated Armoured Unscreened, Under Ground cable to spec. no. IRS:S-63/2014 (Rev.4) or latest
Supply of High Availability Single Section Digital Axle Counter with dual sensor complete set as per RDSO specification No.RDSO/SPN /177/2012 (ver.3) with latest amendment or specification,
21/23 KHZ TX coils assembly suitable for CEL make HASSDAC as per RDSO specification RDSO/SPN/177/2012 (Ver. 3).
21/23 KHZ RX coils assembly suitable for CEL make HASSDAC as per RDSO specification RDSO/SPN/177/2012 (Ver. 3).
Relay ACI, Plug-in-type, Style QTA2, Neutral Track, 9 ohms, 2F/1B , front and back 8 contacts metal to carbon with plug board, retaining clip and connectors conforming to BRS: 939A & 966 (Appendix F2) IRS:S 34 & IRS:S 23 as applicable (interlocking pin code FGHKX).
Supply of Relay A.C. Immune plug in type style ,QBAT D.C. biased track relay, 9 Ohms, 9 D.C. 2F/2B Contracts front and back contact metal to carbon, complete with plug board , retaining clips and connectors, confirming to RDSO/SPN/84 ver 2.0 or latest and RDSO Spec. No. IRS:S@45"44@ S-23 or latest, as applicable . The interlocking code for this unit shall be "ABEJX".
Battery charger -Track Feed self mounting type (10 Amp) as per Specn. No.IRS:S- 89/2013 (Ver.1) or with latest amendment/specification.
Choke Coil for Single Rail Track Circuit on 25 KA 50 Hz AC Electrified Section as per specification No. IRS-S-65/83 (Amd.3) or latest
Insulated 8 SWG GI wire soft suitable for track jumper as per IS:280/78 or latest
Track lead junction Box as per Drg. No.RST-11509 made from FRP (FRP material 13 conforming to RDSO/SPN/151/97 or latest) complete with terminal blocks & links along with FRP Stump for mounting FRP assembly made of FRP Angle 30 x 30 x 4 mm - 1 mtr long (2 Nos) & 12 inch long (1 No.) along with Hardware as per TS.
Non Deteriorating Type of Low Voltage Electric fuse of 2A rating with cylindrical end cap for Railway signalling as per Specn No IRS:S-78/92 or latest.
Non Deteriorating Type of Low Voltage Electric fuse of 6A rating with cylindrical end cap for Railway signalling as per Specn No IRS:S-78/92 or latest.
Pin channel single groove 7.2 mm dia (9/32") suitable for 4 mm dia bond wires.
MF Earthing complete as per RDSO specification No. RDSO/SPN/197 (Ver.1.0) as per Technical Specification
Copper Tape 25 x 3 mm to interconect earth electrodes as per technical specification.
A set of 100 nos. o f welding material for exothermic welding 100 nos.of earthing 19 connections/ railhead continuity bonds all as per IRS specifications S 103-2004 or latest. As per Para 8.4.1 (g) of RDSO Specification No. RDSO/SPN/197 Ver. 1.0, only NABL /ILAC-tested exothermic materials shall be used for exothermic welding.
Exothermic welding tool for welding of railhead continuity bonds along with welder moulds suitable for welding the type of rail bonds of IRS specifications S 103-2004 and technical specifications
Point machine ground connection insulation complete set including P and L bracket insulation as per TS.
Points gauge tie plate insulation complete set as per TS
Point's william stretcher bar insulation complete set as per TS.
Shunt LED signal lighting unit , 110V AC, retrofittable in existing CLS housing and compatible with AC LED ECR as per RDSO specification No. RDSO/SPN/153/2011 Rev.4.1(Draft) or latest
Route LED signal lighting unit , 110V AC, retrofittable in existing CLS housing and compatible with AC LED ECR as per RDSO specification No. RDSO/SPN/153/2011 Rev.4.1(Draft) or latest
Embedded Operator's Console (Embedded PC with 55" or similar VDU + standby with fixing arrangement as per TS.
Embedded Maintenance Console (Embedded PC with 42-43" or similar VDU) with fixing arrangement.
Supply of Modem compatible with existing UFSBI system of DES make or similar as per Specn No. IRS:S-105/2012 (Ver.0) or latest suitable for Deltron make
Supply of Automatic Media change over for modem working on redundant channels for data transmission on OFC/Quad compatible with existing UFSBI system as per Spec. IRS:s-105/ 2012 Ver 0.0 of Make:- Deltron ..
Supply of CCC card (Control Communication Card) Compatible with existing UFSBI System. Make/Brand: Deltron
495/0.3 (35 sqmm) PVC insulated unsheathed single core bright annealed bare copper conductor flexible cables of different colour as per technical specification for voltage grade upto 1100V conforming to IS:694/1990 or latest (coil of 100 mtrs.= 1 Box)
B-Execution for Signal
Charging of secondary cells 2V/300 AH with contractor's own charging equipments 1 including supply of sulphuric acid conforming to IS:266-1977, distilled water conformiong to IS:1069- 1964 with all activities as per technical specification and according to standard practice adopted for initial charging and installation of charged batteries in battery room in groups as per TS.
Charging of 2V/80AH secondary cells with contractor's own charging equipments including supply of sulphuric acid conforming to IS:266-1977, distilled water conformiong to IS:1069- 1964, installation and all other activities as per technical specification.
Excavation of trench 1.0 mtr deep, 0.3 mtr wide at the bottom along railway track in 3 rocky and ballast filled soil, including clearing of bushes, trees, temporary obstruction, bailing out water from the trench etc. and refilling of the trench by excavated soil and ramming after laying of the required quantity of cables as per instruction of Engineer at site.
Laying of Signalling / Quad / OFC Cables of various cores/pairs in trnch/GI /RCC /DWC HDPE pipes/trunking as per Technical specifications.
Installation of TLJB as per TS
Termination of cables including fixing of hylam sheet and supporting on string rod, with supply and providing identification tags/ferrules/tapes with letters on each cable conductor, as per technical specifications.
Making bond hole and fixing bond wires/jumper wires with contractor's own bonding machine and drill bit as per technical specification. (Supply of GI wires & bond pins are not in the scope of work)
Installation of Electric point Machine including supply of G.I. Pipe, termination of cable, wiring, fixing and adjustment of ground connection as per technical specifications.
Supply and Installation of Signal number Plates as per Technical Specification.
Drilling and making hole, fixing, levelling, installation, testing TX coil & RX coil including jumpering and all related cable laying & termination work as well as wheel dip count test and commissioning of total SSDAC/HASSDAC.
Painting , lettering, numbering of newly installed and existing gears including supply of paint as per TS.
Installation, carrying out necessary digging work to make concrete enclosure with lid all with contractor's material and fixing earth electrode in ground, commissioning of complete maintenance free earthing system consisting of Earth Electrode compression couplers, copper strip, cable connections, filling around earth electrode earthing enhancement material, exothermic 15 bonding, all work of earthing as per standard practice and connecting it to equipments to be earthed and all connections between earth electrode and earthing, one end to earth electrode and the other end of the wire to block equipment, power equipment, cable sheath signals and sugre protection devices etc. as per site requirements and technical specifictions. All the consumable for mounting the copper tape inside the relay room. Exothernmic weld material and tools & fixture fot the welding copper tapes and Electrodes etc shall be arrange by the contractor.
Cement concrete work for miscellaneous items in the ratio 1 : 3 : 6, aggregate not 16 exceeding 3 : 8 cm including excavation,raming, curing and plastering with 1 : 4 cement - sand mixture complete with contractor's material including cement, sand, aggregate and curing of casted foundation, refilling & ramming of loose soil around foundation and disposal of loose dugged soil from site.
Fixing of rail head exothermic continuity bonds or earthing connections by cleaning the surface with fine grinder and welding as per exothermic bonding techniques as per IRS S 103/2004 by contractor. Each number means welding at both ends.
C-Supply and installation of telecom items
Supply of 48V/300Ah VRLA Battery as per RDSO Spec No.-IRS: S-93/96 (A) with Amdt 1 No.1 or latest. One set of 48V/300Ah VRLA Battery will consist of 24 Nos. of 2V cells. Batteries must be supplied with suitable trays for fixing in battery boxes along with fixing accessories. Make- Amararaja or similar.
Supply and installation of 12V,130Ah SMF battery as per TS
Supply of 6 QUAD cable Copper conductor Polyethylene insulated Aluminium screened armoured under ground Jelly filled cable as per TS.
Supply of jointing kit as per RDSO Spec No 77/2012 Rev 3Amdt 3 or latest(supply of one 2T VF transformer is included) and as per TS.
Jointing of all types of telecom cable except OFC cable using jointing kit as per TS
Digging of 1.00 Meter deep and 0.3 Meter wide trenches including clearing of roots of trees and bushes and temporary obstruction on rocky/ballast filled soil/under track for track crossing as per technical specifications.
Installation and commissioning of GPS synchronised clock system by metal clamps as 8 per requirement and as per railway representative including laying of power cable in suitable conduit power distribution board and with MCB of suitable rating three pin plug socket, switch etc as site requirement and as TS. All materials required such as MS clamps, nut and bolts etc. shall be supplied by the contractors of existing Clock at New Platform Shed.
Installation of OFC joint enclosure and splicing of optical fiber cable as per TS
Installation, wiring and commissioning of Battery chargers & VRLA batteries at each OFC installation as per technical specification. This includes supply and provision of ladder, DC power supply distribution system and Wiring.
Item Breakup - B-Execution for Signal
Apparatus case (Large) Total 9283.62 Installation of Apparataus cases/Location Boxes on CC foundation on grouted bolts, including filling Item- 8 the space enclosed below the location box with contractor's sand, as per technical specifications. S No. Item Description of Item Unit Qty Rate Amount No
Apparatus case (Large) Total 2785.08 Termination of cables including fixing of hylam sheet and supporting on string rod, with supply and Item- 9 providing identification tags/ferrules/tapes with letters on each cable conductor, as per technical specifications. S No. Item Description of Item Unit Qty Rate Amount No
Apparatus case (Full) Total 2785.08
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .