| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹26.7 LAccepted-AOC | L1 | Accepted-AOC AOC Accepted | |
| 2 | L2₹27.4 L+₹53,726 (2.00%)Rejected-AOC | L2 | Rejected-AOC Rejected | |
| 3 | L3₹28.1 L+₹1.2 L (4.49%)Rejected-AOC WZ 409 0 B 1ST FLOOR PLOT NO 12 JANAK PARK HARI NAGAR NEW DELHI 110064 | NEW DELHI | WEST DELHI | DELHI | 110064 | L3 | Rejected-AOC Rejected | |
| 4 | L4₹29.4 L+₹2.5 L (9.16%)Rejected-AOC RZ H 5 NANDA BLOCK MAHAVIR ENCLAVE PART 1 PAL AM SOUTH WEST DELHI DELHI 110045 | SOUTH WEST DELHI | DELHI | 110045 | L4 | Rejected-AOC Rejected | |
| 5 | L5₹31.8 L+₹4.9 L (18.3%)Rejected-AOC H 13 GEETANJALI PARK WEST SAGARPUR NEW DELHI 110046 | NEW DELHI | DELHI | 110046 | L5 | Rejected-AOC Rejected |
Tender Value
Refer Docs
EMD Value
₹89,000
Closing Date
1 Oct 2020, 6:00 pmClosed
GE (P) AF Gurgaon
GE (P) AF Gurgaon Near Atul Kataria Chwok Gurgaon
CA NO. GE (P) AF/GUR-43/2020-21 PROVN OF FIRE ALARM SYSTEM, LIGHTENING ARRESTER AND CERTAIN B/R WORKS IN BUILDINGS OF 31 MCU AT 27 ED PALAM UNDER GE P AF GURGAON
2020_MES_376312_1
GE (P) AF/GUR-43/2020-21
Open Tender
Miscellaneous Works
Item Rate
180 days
GE (P) AF Gurgaon
All as specified in NIT
10 documents required · 10 mandatory
₹500
GE (P) AF Gurgaon
₹89,000
Yes
23 Oct 2020
10 Sept 2020
3 Oct 2020
10 Sept 2020
1 Oct 2020
17 Sept 2020
Amount
M&L for providing 100mm thick cement concrete 1:4:8 type D-2 using 40mm graded stone aggregate as in sub base of floor complete all as specified and directed by Engr-in-Charge.
Demolition of brick work masonry, built in cement mortar of any description complete all as specified and as directed by Engr-in-charge.
M&L for brick work with sub class 'B' bricks straight or curved on plan exc 6.0 mtr radius built in cement mortar 1:6 complete all as specified and as directed by Engr-in-charge.
M&L for 15mm thick plastering in CM (1:4) by using manufacture/washed plaster grey/yellow sand and mixed with water proofing compound, finished even and smooth finish without using extra cement on fair faces complete all as specified and as directed by Engr in Charge.
Taking down Cement Plaster from wall and ceiling of any description from Brick/concrete surfaces including raking out Joints, hacking for Key, scrubbing down with Water, etc., and removing same from the Site(s), complete all as specified and as directed. (Note :- Rate included for four storey building including scaffolding and all safety measures)
M&L for 15mm thick plastering in CM (1:4) by using manufacture/washed plaster grey/yellow sand and mixed with water proofing compound, finished even and smooth finish without using extra cement on other than fair faces complete all as specified and as directed by Engr in Charge.
Dismantling of Stone slabs and tiles of any description or thickness in floor or wall, aprons and laid badded and pointed in any mortar. Etc complete all as specified and as directed by Engr-in-charge.
M&L for 60 mm Machine pressed pre casted pressed cement concrete inter locking paver blocks coloured up to 6mm on the top with grey cement and pigment in any shape and size, strenth not less than M-35 incl 25mm thick sand cushioning all as directed by Engr-in-charge
M&L for preparation of new plastered surfaces of walls and applying two coats of cement base paint over a coat of white wash priming coat complete all as specified and as directed by Engr-in-charge.
M&L for PCC 1:4:8 type D-2 using 40 mm graded stone aggregate as in foundation, filling and mass concrete etc., complete all as specified and as directed by Engr-in-charge.
Removing existing/old damaged roof treatment of any (Brick tiles with mud phuskha) description by scraping with using wire brush and removing the same from site including dismanteling and refixing of existing tanks in same position after treatment with minor part replacement such as neeple, float etc complete all as specified and as directed by Engr-in charge.
M&L for PCC 1:2:4 type B-1, using 20mm graded stone aggregate as in roof coving/benching and bed block, plateform for tank etc complete all as specified and directed by Engr-in-charge.
M&L for 15 mm thick cement plaster by using manufacture sand in CM 1:4 on brick/concrete surfaces of roof and parapet, mixed with water proofing compound, finished even and smooth without using extra cement (Including 4 Story building) complete all as specified and as directed by Engineer-in-Charge. Note :- Water proofing compound shall be measured & paid separately.
Supply only liquid water proofing compound mix cement concrete/cement plaster as per manufacture instruction all as directed by Engr-in-Charge. Make : DR. FIXIT PIDE PROOF L W, CICO, FOSROC.
M&L for roof treatment applying PU & Acrylic based Elostomeric Coat in UV safe having OVOC coating apply two coats as per manufacturer's instructions to protect roof over clean plastered surface complete all as specified & directed by Engr-in-charge. Make :- M/s Fosroc chemical, M/s STP Limited, M/s Sika India Pvt Ltd, M/s Chaksey Chemical Pvt Ltd, M/s Pentens Note :- (a) Water proofing gurantee for 10 years should be included in the quoted rates. (b) The work shall be executed by company aplicator duly approved by GE and gurantee shall also be given by company.
Dismantling of Wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/slabs/blankets, any thickness, including cover fillets complete all as specified and as directed by Engr-in-charge.
M&L for suspended false ceiling consisting of suitable GI sections of ‘T’ Angle & FI as per Std engineering practices with ‘E’ board classic ceiling boards 4mm thick in grid of 0.60x0.60mtr including cutting holes and making good holes for main joints, suspending with 4mm dia GI wire to roof slab, roof trusses, purlins & rafters etc complete all as specified and as directed by Engr-in-charge.
M&L for 12mm thick Gypsum board false ceiling in designed pattern with 1.50mm thick GI channel frame work GI U-section 50mmx35mmx1.50mm & edge side GI L-section 30mmx25mmx1.50mm and fixed with screws and fastener with flush joint in required pattern and designed and joints punning with 1 to 2mm thick birla putty including suspenders, rubbing with sand paper and finishing with two coat of OBD over a coat of primer complete all as specified and as directed by Engr-in-charge.
Excavating in trenches in soft / loose soil, n exc 1.5 m wide and n exc 1.5m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sqm on plan and n exc 1.5 m in depth and getting out complete all as specified and as directed by Engr-in-Charge.
Returning, filling including spreading, leveling and well ramming in layers not exc 25cm in hard/dense soil complete all as specified and as directed by Engr-in-charge.
Removing excavated soil or debris to a distance exceeding 10 Km but not exceeding 15 Km and depositing where directed at a level not exceeding 1.5 m above the starting point all as specified and as directed by Engr-in-charge.
S&F ESE LA-SIRIUS 107 Mtr (Certified quality equipment protection diameter-107 Mtr with 5 mtr GI mast including PCC foundation as per manufacturers instructions as per site requirement and complete all as specified and as directed by Engr-in-charge.
M & L for test point terminal block made of gun metal or phosphorus bronze /brass size (75 x 75 x25) mm drilled and 3 nos brass screwed 8 mm dia ,10 mm long hex.head screw complete including GI fabricated test point box size 150mm x 100mm x 75mm height with front openable made out of not less than 0.6 mm thick PGI sheet including painting complete all as specified and as directed by engr- in charge.
M&L for earth continuity conductor or main earthing lead fixed to wall / roof and connecting air termination to test point with 20 x 3.15 mm copper strip with saddles, porcelain insulators, nut, bolts, screws, PVC gutka etc complete all as specified and directed by Engr-in-Charge . Note :- (i) Laying / fixing of strip from air termination to test point shall be in one run i.e. there shall be no joint in between air termination. In case joint is required, it shall be jointed with nut & bolt joint with breezing full contact of strip. (ii) Strip shall be fixed on insulator at the interval not more than 900mm in such a manner at any place it shall not touch to wall/ roof / any metalic body.
M&L for earth continuity conductor or main earthing lead fixed to wall / roof and connecting air termination to test point with 32 x 6 mm copper strip with saddles, porcelain insulators, nut, bolts, screws, PVC gutka etc complete all as specified and directed by Engr-in-Charge . Note :- (i) Laying / fixing of strip from air termination to test point shall be in one run i.e. there shall be no joint in between air termination. In case joint is required, it shall be jointed with nut & bolt joint with breezing full contact of strip. (ii) Strip shall be fixed on insulator at the interval not more than 900mm in such a manner at any place it shall not touch to wall/ roof / any metalic body.
Supply, laying and jointing with walls, 50mm bore galvanized iron water tubing medium grade including provision of all necessary ISI marked GI fittings / accessories complete all as specified and directed by Engr-in-charge.
M&L for (Set of 4 electrodes) Chemical/GEM/GEL Earthing system with earth electrode of for copper bonded low carbon steel core of 3 meter long having outer dia 80mm & inner dia 50mm duly filled with highly conductive and anti corrosive compound of required quantity with chemical composition Bentonite 40%, Copper sulphate 10%, Gypsom 5%, Graphite 10%, Alum 5%, Zinc sulphate 10%, Aluminium sulphate 10%, buried directly in ground ( 150-175 mm dia digging or auguring of earth to the required depth as specified by manufacturer and directed ) and pit filled up with GEL form of Electrolytic and Moisture retention type Earthing tested for less than 0.50 ohm Resistivity and connected with copper strip (32x6mm) to rod connected by means Given Terminal point with copper Nut Bolts, provision of ready made polymer chamber with cover, including necessary excavation in any type of soil, returning filling in, removal of surplus soil complete all as specified and as directed. (Makes: Pittas, RPG,HSL Industries, Roksna, Furse). Notes: Earthing system shall be designed so as to achieve test result less than 1 Ohms depending upon the soil conditions for the minimum 5 Years under warranty with 35% Increment in Ohmic value only with same soil resistivity.
S&F wireless smoke detector including testing, Wireless-9 Volts DC, smoke sensor-Temp range -(10 to 70) degree centigrade, humidity range -20% to 95% RH, colour white complete as as specified and as directed, Model No AP SD-900 of make AGNI Protection/Quatac.
S&F Hooster radio meter operating voltage 15 volts DC, indication alarm 85 db, complete as as specified and as directed, Model No AP RE-920 of make AGNI Protection/Quatac.
S&F MCP remote Key of black colour including testing and battery complete as as specified and as directed, Model No AP MCP-910 of make AGNI Protection/Quatac.
S&F 999 smoke detector wireless control panel, wireless receiving distance 1-3 Kilometer including testing complete as as specified and as directed, Make AGNI Protection/Quatac.
S&F Modular fire Extinguisher ABC MAP 90 powder base of capacity 5 Kg including testing complete as as specified and as directed, Make Fire Saver/Omax/Ceasefire/Ultra fire.
Supply, installation, testing and commissioning of Clean agent fire extinguisher filled with HFC 227ea /FK5-1-12UL approved gas, capacity of cylinder 4 Kgs complete as as specified and as directed, Make Fire Saver/Omax/Ceasefire/Ultra fire.
Supply, installation, testing and commissioning of Clean agent fire extinguisher filled with HFC 227ea /FK5-1-12UL approved gas, capacity of cylinder 6 Kgs complete as as specified and as directed, Make Fire Saver/Omax/Ceasefire/Ultra fire.
Supply, installation, testing and commissioning of Clean agent fire extinguisher filled with HFC 227ea /FK5-1-12UL approved gas, capacity of cylinder 9 Kgs complete as as specified and as directed, Make Fire Saver/Omax/Ceasefire/Ultra fire.
Material and labour for point wiring concealed in and including rigid non metallic PVC conduit, medium grade, ISI market, 20 mm dia, with 1.5 sq mm FRHR PVC insulated & unsheathed, multi stranded copper conductor cable, single core, 1100 volts grade, including flush metal terminal boxes and factory fabricated (same make of modular type switches and sockets etc.) modular metal box, cover plates inner & outer, frames of suitable size and depth, FRHR insulated and unsheathed Multi standard copper conductor of 1.5 sqmm and connected to common earth dolly as continuous earth wire (Contractor shall concealed the conduit by making chases by cutter machine then after chiselling only) for one light point/socket point controlled by one switch complete all as specified and as directed.
S&F Switch modular 10 Amps, single pole one way complete all as specified and directed by Engineer-in-charge.
S&F modular type socket outlet shuttered modular type two module 3/5 pin, 6 Amps multipurpose complete all as specified and directed by Engineer-in-Charge.
S&F sheet metal enclosure for MCB's (D.B) 12 way (SPN) 200 Amps rated bus bar complete all as specified and as directed. Cat No- DHDPSHODRW12 Make Havells or equivalent out of makes specified in list of makes.
S&F MCB SP 06 to 32 Amps 10 KA, 240 Volt B Series type complete all as specified and as directed. Make Havells/L&T/Legrand
S&F SPN-40-63 Amps 10 KA,240 Volt B series type complete all as specified and as directed. Make Havelles/L&T/Legrand
M&L for wiring sub main wiring concealed along with earth wire with the following size of HRFR PVC insulated and unsheathed multistranded copper conductor single core cables in concealed through 25 mm rigid non metallic PVC conduit heavy duty with 2x4 sqmm + 1 x 2.5 sqmm earth wire complete all as specified and directed by Engineer-in-Charge. Including cutting chesses pinning in making good to facing and pointing in cement morter 1:3 to the ends or cutting chesses for concealed point wiring and making good disturbed surface complete cutting not exceeding 4 cm girth and 4 cm width. Note:- Two run of cable and one length of PVC conduit with earth conductor shall be measured as a one length complete all as specified and as directed by Engr-in-charge.
Note:- The amount of Rs 18,000/- against Schedule of Credit on Page No 134 shall be deducted from the total amount quoted against Sch 'A' while deriving the Contract Sum for Acceptance.
M/S SURINDERAS CONSTRUCTION CO.
Flint India
SM CONSTRUCTION COMPANY
J.P. Enterprises
Continental Engineers and contractors
New Era Engineers
SATISH KUMAR GUPTA
PARKASH ENTERPRISES
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .