Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance 09 PANZGAM TANGDAR ROAD CHOWKIBAL KUPWARA JAMMU KASHMIR 193224 | KUPWARA | JAMMU AND KASHMIR | 193224 | Admitted-Finance |
| 3 | Admitted-Finance | Admitted-Finance |
| 4 | Admitted-Finance | Admitted-Finance |
Tender Value
₹6.7 L
EMD Value
₹13,420
Closing Date
8 Feb 2020, 4:00 pmClosed
EXECUTIVE ENGINEER
PWD DODA
Repair /Renovation, Addition / Alteration and providing of Aluminum partitions for creation of ETAT facility in OPD block, SNCU and IPD block of Associate Hospital Government Medical College at Doda.
2020_PWDJK_91792_3
e NIT 65 of 2019 20
Open Tender
Civil Works
Item Wise
30 days
DODA
Please refer Tender documents.
3 documents required · 3 mandatory
₹600
Yes
CHALLAN IN ANY GOVT TREASURY
₹13,420
Yes
17 Mar 2020
3 Feb 2020
10 Feb 2020
3 Feb 2020
8 Feb 2020
3 Feb 2020
Amount
Demolishing brick work manually/by mechanical means including stacking of serviceable material and disp of unserviceable material : In cement mortar (including all leads, lifts and carriages)
Taking out doors, windows and clerestory window shutters (steel or wood) including stacking :Of area beyond 3 sq. metres. (including all leads, lifts and carriages)
Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/appropriate Z. sections and other sections of approved make conforming to IS : 733 and IS : 1285, fixed with dash fastener of required dia. and size including necessary filling up of gaps at junctions i.e, at top, bottom and sides with required EPDM rubber I neoprene .. gasket felt etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing I panelling, C.P. brass I stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in- Charge (glazing, panelling and dash fasteners to be paid for separately.) Powder coated aluminium (minimum thckness of powder coated 50 microns)
For shutters of doors, windows & ventilators including providing and fixing hinges I pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber I neoprene gasket required (Fittings shall be paid for separately.) Powder coated aluminium (minimum thickness of powder coated 50 microns)
Providing and fixing 12mm thick prelaminated particle boardflat pressed three layer or graded wood particle board (conforming to IS: 12823 Grade-l type-11) in panelling fixed in aluminium doors, windows shutters and partition frames with C. P. brass I stainless steel screws etc. complete as per architectural drawings and directions of engineer-in-charge. Pre-laminated particle board with decorative lamination on one side and balancing lamination on other side.
Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber I neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge. (Cost of aluminium snap beading shall be paid in basic item.) With float glass panes of 5.50 mm thickness (weight not less than 13 . 50 kg I sqm)
Providing and fixing double action hydraulic floor spring of approved brand and manufacture IS : 6315 marked, having brand logo em,possed on the body/plate with double spring mechanism and door weight upto 125 kg for doors including cost of cutting floors, embedding in floors as required and making good the same matching to the existing floor finishing and cover plates with brass pivot" and single piece M.S. sheet outer box with slide plate etc. complet~ as per the direction of Engineer-in-charge. With Stainless Steel cover plate minimum 1.25 mm thickness.
Brick work with common burnt clay F.P.S.(non-modualar) bricks of class designation 75 in foundation and plinth in Cement mortar 1 :6 ( 1 cement : 6 coarse sand) (including all leads, lifts and carriages)
Extra for brick work in superstructure above plinth level upto floor V level. (By manual means) (including all leads, lifts and carriages)
15mm Cement plaster on the rough side of single or half brick wall of mix: 1 : 6 ( 1 cement : 6 coarse sand) (including all leads, lifts and carriages)
Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
Applying priming coat: with ready mixed pink or grey primer of approved brand and manufacture on wood work (hard and soft wood)
Painting with synthetic enamel paint of approved brand and manufacture to give an even shade. Two or more coats on new work
Applying one coat of water thinable cement primer of approved brand and manufacture on wall surface Water thinable Cement primer
Distempering with 1st quality acrylic washable distemper (ready made) of approved manufacturer and of required shade/ colour complete as per manufacturer's specifications
Two or more coats on new work
one or more coats on old work
Providing and fixing pressed steel door frames conforming to IS: 4351, manufactured from commercial mild steel of 1.25mm/1.60mm thickness including hinges jamb, lock, jamb, bead and if required angle threshold of mild steel angle of section 50x25mm, or base ties of 1.25mm/ 1.60mm pressed mild steel welded or rigidly fixed together by mechanical means, including M.S pressed butt hinges 2.5mm thick with mortar guards, lock strike-plate and shock absorbers as specified and applying a coat of approved steel primer after pre-treatment of the surface as directed by Engineer-in-charge: Sheet of 1.25mm thickness and base ties of 1.25mm.
Providing and fixing panelled or panelled and glazed shutters for doors, windows and clerestory windows including lSI marked M.S. pressed Butt hinges bright finished of required size with necessary screws excluding panelling which will be paid for separately,al! complete as per direction of engineer- in charge. Second class deodar wood
Providing and fixing panelling or panelling and glazing in panelled or panelled and glazed shutters for doors, windows and clerestory windows (Area of opening for panel inserts excluding portion inside grooves or rebates to be measured). Panelling for panelled or panelled and glazed shutters 25 mm to 40 mm thick. Particle Board 12mm thick Plain particle board flat pressed, 3 layer or graded wood particle board medium density Grade I, IS: 3087 marked
Providing and fixing wooden moulded beading to door and window frames with iron screws, plugs and priming coat on unexposed surface etc. complete: 50 x 12 mm
Providing and fixing of laminated wooden panelling 8 mm thick AC-4 under layer frame of 12 mm thick complete job as technical specified.
Providing and fixing of laminated wooden flooring 8 mm thick AC-4 laminated using 2 mm thick foamcomplete job as technical specified.
Providing and fixing of 12.5 mm thick false A.B.F ceiing of gypserm board complete item with G.I suspension system complete job as per technical specification.
Dismantling tile work in floors and roofs laid in cement mortar including stacking material For thickness of tiles 10 mm to 25 mm (including all leads, lifts and carriages)
Engaging labour in already existing all partition in SNCU Toilet
Carpenter
Labour
M/S MIR CONSTRUCTION COMPANY
Mirza Ishtiaq Ahmed Beg and Sons
Razia begum
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .