Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹14.2 LAccepted-AOC | ₹14.2 L Quoted ₹15.6 L | L1 | Accepted-AOC Being L1 |
| 2 | L2₹15.7 L+₹15,464 (0.99%)Rejected-Finance | ₹15.7 L+₹15,464 (0.99%) | L2 | Rejected-Finance Not Being L1 |
| 3 | L3₹15.9 L+₹35,145 (2.26%)Rejected-Finance | ₹15.9 L+₹35,145 (2.26%) | L3 | Rejected-Finance Not Being L1 |
| 4 | L4₹17.2 L+₹1.6 L (10.4%)Rejected-Finance | ₹17.2 L+₹1.6 L (10.4%) | L4 | Rejected-Finance Not Being L1 |
| 5 | L5₹17.4 L+₹1.8 L (11.5%)Rejected-Finance S 17 77 1 CHARAN NAGAR COLONY NADESAR VARANASI UTTAR PRADESH PIN 221002 | VARANASI | UTTAR PRADESH | 221002 | ₹17.4 L+₹1.8 L (11.5%) | L5 | Rejected-Finance Not Being L1 |
Tender Value
₹25 L
EMD Value
₹50,000
Closing Date
17 Mar 2023, 6:00 pmClosed
GE (MES) Ayodhya
Garrison Engineer Military Engineer Services Ayodhya
REPAIR MAINT OF CEILING FANS EXHAUST FANS WALL MOUNTED FANS AND SUMMER APPLIANCES WITH ALLIED WORKS AT AYODHYA CANTT UNDER GE AYODHYA
2023_MES_581677_1
8359/E8
Open Tender
Civil Works
Item Rate
180 days
Ayodhya
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE (MES) Ayodhya
₹50,000
Yes
12 Apr 2023
17 Feb 2023
20 Mar 2023
18 Feb 2023
17 Mar 2023
4 Mar 2023
Amount
Part- I : Window/Split AC M&L for dismantling the cover of condensor and cooling coil, thoroughly cleaning the external surfaces (both sides) of all the components including fins, base , discaling chemicals, water etc with the help of air blower, wire brushing and re-assembling all the components such as plate, runner, fan blade etc in original position as and when directed for Air Conditioners of the following capacities: -
Window Type Air Conditioner upto 2 TR capacity.
Split type Air Conditioner upto 2 TR capacity (1 x Indoor unit and 1 x Outdoor unit)
S&F in replacement, AC single phase 230 Volts contactor assembly for 1.5 / 2.0 TR capacity split AC condensing unit complete all as specified and directed by Engr-in-Charge.
M&L for repair of AC single phase 230 volt PCB for 1.5/ 2.0 TR capacity split/window AC cooling unit complete all as specified and directed by Engr-in-Charge.
M&L for replacement of AC single phase 230 Volts Remote (Hand set) for 1.5/ 2.0 TR capacity window/split AC complete all as specified and directed by Engr-in-Charge.
M&L for replacement of blower motor for 1.5 / 2 TR window window/split AC complete all as specified and directed by Engr-in-Charge.
M&L for replacement of runner motor for 1.5/2 TR split AC complete all as specified and directed by Engr-in-Charge.
M&L for replacement of strainer for window/split AC of any capacity complete all as specified and directed by Engr-in-Charge.
M&L for replacement of 4/6 mfd capacitor for blower motor of window/split AC of any capacity complete all as specified and directed by Engr-in-Charge.
M&L for replacment of 36/50 mfd running capacitor for compressor of window/split AC of any capacity complete all as specified and directed by Engr-in-Charge.
M&L for replacement of 80/100 starting capacitor for compresor of window/split AC of any capacity complete all as specified and directed by Engr-in-Charge.
M&L for replacement of thermostat for 1.5/2 TR window/split AC complete all as specified and directed by Engr-in-Charge.
M&L for replacement of sensor for 1.5/ 2.0 TR window/split AC complete all as specified and directed by Engr-in-Charge.
M&L for replacement of fan blade of blower motor for 1/1.5/2 TR window/split AC complete all as specified and directed by Engr-in-Charge.
M&L for replacement of over load protector for 1.5/2 TR window/split AC complete all as specified and directed by Engr-in-Charge.
M&L for replacement of capillary copper tube of size 0.064 inch dia complete all as specified and directed by Engr-in-Charge.
M&L for replacement of runner for 1.5/ 2.0 TR window/split AC complete all as specified and directed by Engr-in-Charge.
M&L for replacement of starting relay for 1.5/2 TR window/split AC complete all as specified and directed by Engr-in-Charge.
M&L for replacement of front cabinet for 1.5/2 TR window AC complete all as specified and directed by Engr-in-Charge.
M&L for replacement of air filter for 1.5/2 TR window/split AC complete all as specified and directed by Engr-in-Charge.
Disconnecting electrically and mechanically and taking out existing unserviceable sealed unit from 1.5/2 TR window AC of any make and S & F in replacement new sealed compressor suitable for 1.5/2 TR window AC and connecting up suction and discharge pipe line with gas welding and gas charging complete all as specified and directed by Engr-in-Charge.
All as per Srl item No. 21.00 above but for 1.5/2 TR split AC complete all as specified and directed by Engr-in-Charge. Note for Item No 21 & 22 : Compressor/sealed unit shall have one year replacement guarantee from date of installation
S&F in replacement of swing motor as per existing size and type for 1.5/2 TR window complete all as specified and directed by Engr-in-Charge.
S&F 20mm dia PVC pipe, heavy duty for drain out of condensing water of window/split AC including cutting of floors or making hole in wall and making good the disturbed portion after laying pipe with sadles etc to match the existing surface with original specifications complete all as specified and directed by Engr-in-Charge.
Supply and laying copper pipe (hard) 5/8" dia with PUF insulation, CFC free etc as required at site complete all as specified and directed by Engr-in-Charge.
Supply and laying copper pipe (hard) 3/8" dia with PUF insulation, CFC free etc as required at site complete all as specified and directed by Engr-in-Charge.
Cleaning/servicing of cooling/condensing coil with the help of compressed nitrogen inner side of the copper tube for flushing out all sludge and oil deposited in the copper tube and materials and labour for charging of refrigerant R-22/R-32/R-410 as required including replacement of strainer and finding out the leakage, brushing the same and testing of 1/1.5/2 TR window/split AC complete all as specified and directed by Engr-in-Charge.
M&L for taking out and dismantling the existing rusted unserviceable condensor coil from existing system of 1/1.5/ 2.0 TR window/split AC located at different places after decanning refrigerent gas from the system to empty cylinder, disconnecting all electrical connection, flair nuts, valves and shut down all preventive valves properly, supply and replace with new condensing coil as per existing size and specification including necessary fixing arrangement and electrical connection and safety protection devices to the existing system and flushing the whole system by nitrogen, leak testing by 200 PSI nitrogen pressure holding of 48 hours, charging of decanning refrigerent to the system and charging of additional refrigerent as required, commisioning and testing complete all as specified and directed by Engr-in-Charge.
M&L for taking out and dismantling the existing rusted unserviceable cooling coil from existing system of 1/1.5/ 2.0 TR window/split AC located at different places after decanning refrigerent gas from the system to empty cylinder, disconnecting all electrical connection, flair nuts, valves and shut down all preventive valves properly, supply and replace with new cooling coil as per existing size and specification including necessary fixing arrangement and electrical connection and safety protection devices to the existing system and flushing the whole system by nitrogen, leak testing by 200 PSI nitrogen pressure holding of 48 hours, charging of decanning refrigerent to the system and charging of additional refrigerent as required, commisioning and testing complete as directed by Engr-in-Charge.
M&L for gas charging of refrigerant R-22/R-32/R-410 in window/split AC complete all as specified and directed by Engr-in-Charge.
Supply,Installation testing and commissiong of copper piping (Max flow) 35mm OD x 1.2 mm complete all as specified and directed by Engr-in-Charge.
Supply,Installation testing and commissiong of copper piping (Max flow) 28mm OD x 0.9 mm complete all as specified and directed by Engr-in-Charge.
Supply,Installation testing and commissiong of copper piping (Max flow) 22mm OD x 0.9 mm complete all as specified and directed by Engr-in-Charge.
Supply,Installation testing and commissiong of copper piping (Max flow) 15mm OD x 0.9 mm complete all as specified and directed by Engr-in-Charge.
Supply and install Monitor Split Ac Stand / Heavy Duty Air Conditioner Outdoor Unit mounting bracket made up of Heavy Duty GI Steel ( For Maximum Strength ) Load Carring Capacity Upto 160 Kgs ( Best in Class ) complete all as specified and directed by Engr-in-Charge.
S&F metal clad AC socket 32 A, 230 volt complete all as specified and directed by Engr-in-Charge.
S&F metal clad AC plug top 32A, 230 volt complete all as specified and directed by Engr-in-Charge.
S&F DBOXx MCB protected AC socket complete with 25 A MCB, starter, socket and plug top, 240 volts single phase for AC complete all as specified and directed by Engr-in-Charge.
Part-II : Refrigerator/Deep freezer M&L for dismantling cover of condensor and cooling coil, thoroughly cleaning the external surface (both side) of all the component including fins, base , discaling chemicals, water etc with the help of air blower, wire brushing and reassemble all the components plate, runner, fan blade etc in original position as and when directed for refrigerator/deep freezer upto 315 ltrs capacity complete all as specified and directed by Engr-in-Charge.
M&L for replacement of starting relay of refrigerator/deep freezer upto 315 ltrs capacity complete all as specified and directed by Engr-in-Charge.
M&L for replacement of capillary copper tube of size 0.36 mm of refrigerator/deep freezer upto 315 ltrs capacity complete all as specified and directed by Engr-in-Charge.
Disconnecting defective cooling coil of refrigerator/deep freezer upto 315 ltrs capacity and replacing the same with new cooling coil and fixing in original position as per existing complete all as specified and directed by Engr-in-Charge.
Disconnecting defective condensing coil of refrigerator/deep freezer upto 315 ltrs capacity and replacing the same with new condensing coil and fixing in original position as per existing complete all as specified and directed by Engr-in-Charge.
M&L for replacement of fan motor of refrigerator/deep freezer of any capacity complete all as specified and directed by Engr-in-Charge.
M&L for replacment of 6/10 mfd running capacitor for compressor of refrigerator/deep freezer upto 315 ltrs capacity complete all as specified and directed by Engr-in-Charge.
M&L for replacement of 40/60 starting capacitor for compresor of deep freezer upto 315 ltrs capacity complete all as specified and directed by Engr-in-Charge.
M&L for replacement of 80/100 starting capacitor for compresor of deep freezer upto 315 ltrs capacity complete all as specified and directed by Engr-in-Charge.
M&L for replacement of thermostat of refrigerator/deep freezer upto 315 ltrs capacity complete all as specified and directed by Engr-in-Charge.
M&L for replacement of Inner lights of refrigerator/deep freezer upto 315 ltrs capacity complete all as specified and directed by Engr-in-Charge.
M&L for replacement of door switch of refrigerator/deep freezer upto 315 ltrs capacity complete all as specified and directed by Engr-in-Charge.
S&F in replacement of over load protector for refrigerator/deep freezer upto 315 ltrs capacity complete all as specified and directed by Engr-in-Charge.
M&L for replacement of AC single phase 230 volt PCB for refrigerator/deep freezer upto 315 ltrs capacity complete all as specified and directed by Engr-in-Charge.
Disconnecting electrically and mechanically refrigerator/deep freezer and taking down sealed unit of compressor of refrigerator/deep freezer upto 315 ltrs capacity and replacement with new sealed unit of compressor of same size, type and capacity including connecting sealed unit and discharge pipe with gas weldind/soldering including gas charging complete all as specified and directed by Engr-in-Charge. Note : Compressor/Sealed unit shall have one year replacement guarantee from date of installation.
Leak testing of gas circulation system of refrigerator/deep freezer upto 315 ltrs capacity and supply & charging of refrigerant Gas R-12/R-134A as per existing in entire system including supply and replacement of drier/filter and punching/providing dead plug complete all as specified and directed by Engr-in-Charge.
Part-III : Water Cooler M&L for dismantling cover of condensor and cooling coil, thoroughly cleaning/servicing the external surface (both side) of all the component including fins, base , discaling chemicals, water etc with the help of air blower, wire brushing and reassemble all the components plate, runner, fan blade etc in original position as and when directed for water cooler upto 150 ltrs capacity complete all as specified and directed by Engr-in-Charge.
Taking down unserviceabe sealed unit of water cooler upto 150 ltrs capacity and S&F in replacement new sealed compressor and connecting up suction and discharge copper pipe , gas filter, capillary etc with gas charging, welding and commissioning complete all as specified and directed by Engr-in-Charge. Note : Compressor/Sealed unit shall have one year replacement guarantee from date of installation.
M&L for leakage testing of gas circulation system of refrigerator/deep freezer upto 315 ltrs capacity and supply & charging of refrigerant Gas R-134A as per existing in entire system including supply and replacement of drier/filter and punching/providing dead plug complete all as specified and directed by Engr-in-Charge.
M&L for gas charging of refrigerant R-134A in refrigerator/deep freezer/Water Cooler complete all as specified and directed by Engr-In-Charge
M&L for replacement of fan motor of water cooler of any capacity complete all as specified and directed by Engr-in-Charge.
M&L for preparation of old painted steel surfaces of water cooler by complete scraping and applying one coat of metalic enamel paint by spraying on outer surface as per existing colour and black synthetic enamel paint on bottom portion such as compressor, bottom frame etc. of water coolers upto 150 ltrs capacity complete all as specified and directed by Engr-in-Charge.
S&F PVC connection pipe 15mm dia and 90 cm length with PTMT nuts & washers at both ends for water connection of water coolers upto 150 ltrs capacity complete all as specified and directed by Engr-in-Charge.
S&F PVC drain pipe flexible heavy duty with necessary saddles and fittings for drain out water from water cooler complete all as specified and directed by Engr-in-Charge.
S&F in replacement of fan blade for water cooler upto 150 ltrs capacity complete all as specified and directed by Engr-in-Charge.
S&F in replacement of water tray stainless steel for water cooler upto 150 ltrs capacity complete all as specified and directed by Engr-in-Charge.
M&L for replacement of 10/15 mfd running capacitor for Water Cooler upto150 ltrs capacity complete all as specified and directed by Engr-in-Charge.
M&L for replacement of 40/60 mfd starting capacitor for water cooler upto 150 ltrs capacity complete all as specified and directed by Engr-in-Charge.
M&L for replacement of 15mm bore chromium plated push cock as per existing shape suitable for water cooler upto150 ltrs capacity complete all as specified and directed by Engr-in-Charge.
M&L for replacement of thermostat for water cooler upto 150 ltrs capacity complete all as specified and directed by Engr-in-Charge.
M&L for replacement of starting relay suitable for water cooler upto 150 ltrs capacity complete all as specified and directed by Engr-in-Charge.
M&L for replacement of over load protector suitable for Water Cooler upto 150 ltrs capacity complete all as specified and directed by Engr-in-Charge.
Part-IV : Desert Cooler Repair / maint / servicing of desert coolers upto 4000 Cum/hr by dismantling desert cooler complete disconnecting and removal of cooler fan and water pump, old wornout wood wool pads/khus pads etc and painting the complete cabinet of desert cooler externally one coat over existing coat including body side panel, front panel and internally with one coat of black synthetic enamel paint after complete rubbing and cleaning of wood wool and overhauling and painting of exhaust fan, kit fan general checking, greasing/oiling of pumps and fixing back to its existing position to make functional to the entire satisfaction complete all as specified and directed by Engr-in-Charge.
S&F wood wool pads suitable for desert cooler upto 4000 Cum/hr capacity complete all as specified and directed by Engr-in-Charge.
S&F PVC pipe heavy duty 15mm bore from water pump to wool compartment of desert cooler upto 4000 Cum/hr capacity complete all as specified and directed by Engr-in-Charge.
S&F PVC water distributor 4 way suitable for desert cooler upto 4000 Cum/hr capacity complete all as specified and directed by Engr-in-Charge.
S&F rotary/bed switch 5 Amp suitable for desert cooler upto 4000 Cum/hr capacity complete all as specified and directed by Engr-in-Charge.
M&L for replacement of front grill for desert cooler upto 4000 Cum/hr capacity complete all as specified and directed by Engr-in-Charge.
S&F in replacement of bottom tank of desert cooler by replacing with new bottom tank made out of MS black sheet 20 gauge thickness including bolting etc suitable for desert cooler upto 4000 Cum/hr capacity complete all as specified and directed by Engr-in-Charge.
M&L for rewinding of fan motor of desert cooler upto 4000 Cum/hr capacity complete all as specified and directed by Engr-in-Charge.
M&L for replacement of fan motor of desert cooler upto 4000 Cum/hr capacity complete all as specified and directed by Engr-in-Charge.
S&F in replacement of water lifting pump vertical type single phase, 230V, 18 watt suitable for desert cooler upto 4000 Cum/hr capacity complete all as specified and directed by Engr-in-Charge.
S&F fan blade for desert cooler fan upto 4000 Cum/hr capacity complete all as specified and directed by Engr-in-Charge.
Part- V : Voltage Stabiliser Repair of voltage stabilizer including replacement of minor spares and testing complete all as specified and directed by Engr-in-Charge. Note : (i) Major spares for repair will be measured and paid separately as supply only under relevant item of this schedule. (ii) Spares not mentioned in this schedule but required at site for repairing the stabilizer deemed to be included in the quoted rate.
Supply only circuit transformer suitable for voltage stabilizer upto 2 KVA
Supply only circuit transformer suitable for voltage stabilizer 3 KVA to 5 KVA
Supply only fuse grip for voltage stabilizer upto 5 KVA
S&F PCB of matching size for voltage stabilizer upto 5 KVA, single phase, AC supply
Part-VI Ceiling Fan Taking down defective ceiling fan 1200/1400 mm sweep, checking of faults and refixing the same in original position after gressing and repairing of faults including replacement of unsv components complete all as specified and directed by Engr-in-Charge. Note : Items required for repairing shall be measured and paid for separately at supply only rates.
Supply only gun metal bush suitable for ceiling fan of 1200/1400 mm sweep complete all as specified and directed by Engr-in-Charge.
Supply only bearing suitable for ceiling fan 1200/1400 mm sweep complete all as specified and directed by Engr-in-Charge.
M&L for MS fan hanger clamp with suitable bolts, nuts, washers, split pin and rubber reel complete all as specified and directed by Engr-in-Charge.
M&L for MS fan hanging nut and bolt of suitable size with split pin complete all as specified and directed by Engr-in-Charge.
S&F split pin ( 100 Nos in each packet) for ceiling fan as per sample complete all as specified and directed by Engr-In-Charge
Supply only condenser 2.5 Mfd suitable for ceiling fan 1200/1400 mm sweep complete all as specified and directed by Engr-in-Charge.
Supply only ceiling fan downrod 450 mm long (minium thickness 1.50 mm) complete all as specified and directed by Engr-in-Charge.
Supply only ceiling fan downrod 1200 mm long (minium thickness 1.50 mm) complete all as specified and directed by Engr-in-Charge.
Supply only ceiling fan downrod 5000 mm long (minium thickness 1.50 mm) complete all as specified and directed by Engr-in-Charge.
M&L for rewinding of burnt ceiling fan of 1200/1400 mm sweep with super enamelled copper winding wire as per existing weight complete all as specified and directed by Engr-in-Charge.
M&L for painting of ceiling fans complete in situ with synthetic enamel paint by spraying including filling cavities with filler, one coat after cleaning all dust etc complete all as specified and directed by Engr-in-Charge.
S&F MS Fan hook with clamps, bolt nut etc suitable for fixing of fan with GI pipe or wood frame made by 40/50 mm dia or angle iron of size up to 50mm complete all as specified and directed by Engr-in-Charge.
Part-VII : Exhaust Fan Taking down defective exhaust fan upto 600 mm sweep, checking of faults and refixing the same in original position after gressing and repairing of faults including replacement of unsv componentscomplete all as specified and directed by Engr-in-Charge. Note : Items required for repairing shall be measured and paid for separately at supply only rates.
Supply only exhaust fan motor support bracket (set of 4) suitable for 230/300 mm sweep complete all as specified and directed by Engr-in-Charge.
Supply only exhaust fan motor support bracket (set of 4) suitable for 450/600 mm sweep complete all as specified and directed by Engr-in-Charge.
Supply only rubber pads (set of 4) suitable for exhaust fan 230/300mm sweep complete all as specified and directed by Engr-in-Charge.
Supply only rubber pads (set of 4) suitable for exhaust fan 450/600mm sweep complete all as specified and directed by Engr-in-Charge.
Supply only Exhaust fan blade suitable for 230/300 mm sweep complete all as specified and directed by Engr-in-Charge.
Supply only Exhaust fan blade suitable for 450/600 mm sweep complete all as specified and directed by Engr-in-Charge.
Supply only condenser 4/6 mfd for exhaust fan upto 600mm sweep complete all as specified and directed by Engr-in-Charge.
M&L for louver shutter suitable for exhaust fan of 230/300 mm sweep complete all as specified and directed by Engr-in-Charge.
M&L for louver shutter suitable for exhaust fan of 450/600 mm sweep complete all as specified and directed by Engr-in-Charge.
Supply only bearing suitable for exhaust fan of 230/300 mm sweep complete all as specified and directed by Engr-in-Charge.
Supply only bearing suitable for exhaust fan of 450/600 mm sweep complete all as specified and directed by Engr-in-Charge.
Rewinding of burnt exhaust fan of 230/300 mm sweep with super enamelled copper winding wire as per existing weight complete all as specified and directed by Engr-in-Charge.
M&L for rewinding of burnt exhaust fan of 450 mm sweep with super enamelled copper winding wire as per existing weight complete all as specified and directed by Engr-in-Charge.
M&L for rewinding of burnt exhaust fan of 600 mm sweep with super enamelled copper winding wire as per existing weight complete all as specified and directed by Engr-in-Charge.
Part- VIII : Wall Mounted Fan Taking down of defective wall mounted fan upto 400 mm sweep, checking of faults and refixing the same in original position after greasing and repairing of faults including replacing old components complete all as specified and directed by Engr-in-Charge. Note : Items required for repairing shall be measured and paid for separately at supply only rates
Supply only bearing suitable for wall mounting fan upto 400 mm sweep complete all as specified and directed by Engr-in-Charge.
Supply only bush suitable for wall mounting fan upto 400 mm sweep complete all as specified and directed by Engr-in-Charge.
Rewinding of burnt wall mounting fan upto 400 mm sweep with super enamelled copper winding wire as per existing weight complete all as specified and directed by Engr-in-Charge.
M&L for replacement of swing motor of wall mounting fan upto 400 mm sweep capacity complete all as specified and directed by Engr-in-Charge.
M&L for painting of wall mounting fan upto 400 mm sweep complete in situ with synthetic enamel paint by spraying including filling cavities with filler, one coat after cleaning all dust etc complete all as specified and directed by Engr-in-Charge.
Khan Brothers
Ajanta Motor Store
m/s allied enterprises
Charan sales and Service
MISRA TRADING CORPORATION
Jairajyadav security services
M/s Hanspal Enterprises
ANKIT SHIP REPAIRERS AND SUPPLIERS
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .