Executive Engineer MICD Srinagar
Executive Engineer MICD Gogji Bagh Srinagar
Electro mechanical Preventive , Routine maintenance works of VT pumps, OHT Crane, Battery Charger, Soft Starters, 33 and 11 KV HT panels etc at Stage 3rd LIS Tral
2026_IFC_307611_1
e- NIT No. MICD 3 OF 2026-27 Dated 09-04-2026
Open Tender
Electrical and Maintenance Works
Item Rate
15 days
Tral Stage 3rd
Please refer Tender documents.
8 documents required · 8 mandatory
₹100
Yes
Executive Engineer MICD Srinagar
₹1,200
Yes
5 Jun 2026
9 Apr 2026
21 Apr 2026
9 Apr 2026
20 Apr 2026
9 Apr 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Maintenance to WPIL make 15 cusec VT pumping unit coupled with 800 KW Prime mover LIS Tral 3rd to unit no 1,2,3,4, `. The job includes as per the Annexure of the SBD. | - | Job. | - | - |
| 2 | Servicing to panel for 15.00 M Ton capacity and 8.00 M Ton capacity EOHT cranes. The Job includes as per the Annexure of the SBD | - | Job | - | - |
| 3 | Maintenance /Checking to Automatic Float Cum boost 110V,15A Battery Charger . The job includes as per the Annexure of the SBD. | - | Job | - | - |
| 4 | Complete Servicing of Each Vacuum Circuit Breakers of 11KV panel in the pump house and Vacuum Circuit Breakers of 33KV panel in the Transformer yard. The job includes as per the Annexure of the SBD. | - | Job | - | - |
| 5 | Maintenance /Checking to 800 KW soft Starter by way of following
Checking /maintenance to CT operated coils 200 A/5A, 400 Amp AC contactor assembly ,Auxiliary Contactors, timer, Push button .auxiliary wiring etc | - | Job | - | - |
| 6 | Servicing of 03 pole 33 KV Isolators in the Transformer yard by way of checking after disconnecting the power supply in the transformer yard by main isolator . The job includes as per the Annexure of the SBD. | - | Job | - | - |
| 7 | General checking of all VRLA type batteries (55 Nos) lying in the pump house and invatubular batteries (03 Nos) lying in the transformer yard ,its terminal and connector checking ,lubrication of terminals by standard petroleum jelly . The job involves topping of the ( 03 no) invatubular batteries by electrolyte thimbling where required | - | Job | - | - |
| 8 | Providing of spare fresh mineral oil reputed make for the pumping units as off and on water enters the bearing housing during operation and creates urgency for filling of new mineral oil after drainage of old water mixed /degraded M.Oil to save the thrust bearing from being damage and to make the pumping units operational again | - | Liter | - | - |
stage.html
html • 0.02 MB
tech_bid_open.pdf
tech_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.44 MB
BOQ_997830.xls
BOQ • 0.25 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .