Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹43.7 LAccepted-AOC 251A 56 N S C BOSE ROAD KOLKATA 700 047 | KOLKATA | KOLKATA | WEST BENGAL | 700047 | L1 | Accepted-AOC Being a lowest Bidder | |
| 2 | L2₹45.1 L+₹93,464.88 (2.12%)Rejected-Finance VILL PUILLYA PO UNSANI DISTT HOWRAH PIN 711302 | HOWRAH | WEST BENGAL | 711302 | L2 | Rejected-Finance Other than lowest | |
| 3 | L3₹46.5 L+₹2.3 L (5.24%)Rejected-Finance BHANGARMATH THAKURANI CHAWK PO SAMABYPALLY BALLY HOWRAH 711 205 WEST BENGAL | HOWRAH | WEST BENGAL | 711205 | L3 | Rejected-Finance Other than lowest | |
| 4 | L4₹46.7 L+₹2.5 L (5.72%)Rejected-Finance TIORKHALI MAHESHGANJ NADIA | NADIA | NADIA | WEST BENGAL | 790804 | L4 | Rejected-Finance Other than lowest | |
| 5 | L5₹47.0 L+₹2.9 L (6.48%)Rejected-Finance 0 HISAR HISAR HARYANA 125004 UDYAM HR 06 0052049 | HISAR | HARYANA | 125004 | L5 | Rejected-Finance Other than lowest |
Tender Value
₹39.9 L
EMD Value
₹79,700
Closing Date
2 Nov 2021, 6:00 pmClosed
GE (FW) Kolkata
D9 COMMISSARIAT ROAD HASTINGS KOLKATA 700022
PROVN OF SYNHETIC BADMINTON COURT NEAR ROYAL BARRACK WITH HALOGEN LIGHTS , SPL REPAIR TO FENCING AND PATHWAY AT WATR GATE AREA AND PROVN OF WALL PANELLING IN CORRIDOR AND GRANITE STEPS AT RAMPART-03 INSIDE FORT WILLIAM UNDER GE (FW) KOLKATA
2021_MES_481064_1
8791/E8
Open Tender
Civil Works
Item Rate
180 days
GE (FW) kolkata
As per tender documents
6 documents required · 6 mandatory
₹500
Yes
GE (FW) Kolkata
₹79,700
Yes
9 Dec 2021
12 Oct 2021
3 Nov 2021
12 Oct 2021
2 Nov 2021
25 Oct 2021
Amount
SCHEDULE 'A' PART-I (B/R WORKS)
M&L for surface excavation not exceeding 30 cm deep and averaging 15 cm deep and getting out in soft/loose soil.complete all as specified and directed.
M&L for excavating in trenches not exceeding 1.5 metre wide and not exceeding 1.5 metre in depth in soft/loose soil complete all as specified and directed.
M&L for returning filling in including spreading, leveling, watering and well ramming in layer not exceeding 25 cm for soft/loose soil complete all as specified and directed.
M&L for removing excavated soil not exceeding 50 m and depositing where directed at a level not exceeding 1.5 metre above the starting point complete all as specified and directed.
M&L for removing excavated soil upto a distance exc 250 m but not exc 500 m and depositing where directed at a level not exceeding 1.5 metre above the starting point complete all as specified and directed.
M&L for excavating in post holes (or similar holes) each not exceeding 0.5 Cum, getting out, returning filling in and ramming earth or broken rubble mixed with earh around in layers not exceeding 25 cm for soft/loose soil complete all as specied and directed.
M & L for hardcore of gauge not exc 63 mm, deposited, spread and levelled in layers not exceeding 15 cm thick, watered and rammed to true surface with broken stones complete all as specified and directed.
M&L for plain cement concrete (1:2:4) type B2 (using 40 mm graded aggregates) in foundation filling and mass concrete complete all as specified and directed.
M & L for plain cement concrete (1:4:8) type D2 using 40 mm graded aggregates in foundation filling and mass concrete complete all as specified and directed.
M&L for plain cement concrete (1:1½:2) type A1 (using 20 mm graded aggregates) in mass concrete complete all as specified and directed.
Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using ex tra cement, including forms, moulds, mi- tred/stopped ends etc.
M&L for plain cement concrete (1:3:6) type C2 (using 40 mm graded aggregates) in walls or retaining walls, any thickness, size or shape including pilasters, buttresses columns, pillars, boundary pillars and posts (including caps and bases) complete all as specified and directed.
M&L Machine pressed precast concrete interlocking paver block with grey cement and pigment any shape and size confirming to IS:15658-2006 of 60 mm thickness M-35 Grade with grey cement and pavement complete all as specified and as directed. (NOTE: Sand cushioning, if required shall be measured and paid seperately)
M&L Sand filling under floors under paver block, thickness not exc 40 mm including consolidation complete all as specified and as directed
Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5 mm), including making drainage opening wherever required complete all as specified and directed
M&L 15 mm thick rendering in cement mortar (1:4) to brick or concrete wall surfaces, finished even and smooth without using extra cement all as specified and as directed by the Engineer-in-Charge.
M&L mild steel work in tubular trusses including special shaped washers etc complete using ERW or induction butt welded tubes conforming to IS-1161:2014 grade St-240 complete all as specified and directed. (NOTE: Quoted rates shall be deemed to include for cutting to dead length where required, notching, drilling, fitting, riveting and/or welding or connecting with bolts and nuts (including rivets or bolts and nuts), providing and fitting angle cleats, fish plates, gusset plates etc., also for wedging, plumbing, truing up and fixing complete)
S&F plates (plain or chequered) channels, square cut or notched (ordninary and counter sunk) forming holes, without any attachment all as specified rolled mild steel in stairs ( framed) including stringers, treades landing, balusters, hand rails etc including cleats, brackets etc complete all as specified and as direceted.
M&L for Mild steel hand rails, for doors, balusters, nosing to steps including embeding in concrete and screwing etc. wind ties for roof including securing bolts, posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, flat iron fillets (for securing wire mesh etc) including all neL W Cessary drilling, bolting or riveting etc. and similar work conforming to Fe-290 Gde E-165 complete .
S&F 0.50 mm thick TCT (total coated thickness) pre-coloured galvalume sheets with minimum base metal thickness of 0.45 mm, single skin high rib/multi rib profile galvalume sheeting having 1000-1020 mm width and 28-30 mm high crest @ maximum 250-255 mm pitch (centre) with sheets manufactured out of 0.50 mm this TCT (total coated thickness) high tensile galvalume sheets having tensile strength 550 MPA with 18-20 micron top coat over 5 micron primer and 8-10 micron alkyld backer zinc aluminium alloy AZ-150, sheets having a dip metallic zinc (43.5%0 aluminium (55%) & silicon (1.5%) with total mass coating of 150 gms/sqm on both sides, having wide pans with minimum 3 small stiffening ribs for effective water shedding and special male/female ends with full return legs on laps for purlin support and fixed as per existing profile of roof complete all as specified and directed.
Supply only chain link fencing made out of galvanised iron wire, any dia or mesh size, made upto into mattress or cages, complete all as specified and as directed. NOTE: Weight of chain link fence shall be verified through a BOO.
Straining and fixing only chain link fencing to MS Posts including provision of 10 mm dia MS bar as line wire welded to fencing post and MS flat iron, complete all as specified and as directed. NOTE: MS post, MS round bars, flat iron, nuts & bolts shall be measured and paid separately.
S&F PVC coated chain link fencing 3 mm dia galvanised wire mesh (mesh size 100 mm x 100 mm) made up to tapped wire and laid on portion /fixed on poles complete all as specified and directed. NOTE: MS post, MS round bars, flat iron, nuts & bolts shall be measured and paid separately.
MS & F MS 10 mm dia round bar and fixed independently to angle iron for chain link fencing cut to length, bend to shape required, complete all as specified and as directed
M&L Mild Steel Screw Bolts (machine made) 11mm to 15mm diameter of neck and length of bolt exc 5 Cm and not exc. 10 Cm with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, complete all as specified and as directed.
M&L for Mild steel framed works such as grills, gratings etc. with ends of bars shouldered and/or riveted or forged into spikes, framed guard bars, barred iron doors, ladders, framed balusters, walkways, railings, framework of water tanks and similar works conforming to Fe-290 Gde E-165 complete
Re-fixing of old serviceable mild steel fencing posts and struts including cutting tops to shape as directed drilling holes notching for wire etc flat iron fillets including all necessary drilling bolting or riveting etc and similar work complete all as specified and directed.
M&L TMT Bars 10 mm dia and over, cut to length, bent to shape required including crank-ing, bending and binding with and including Mild Steel Wire (annealed) not less than 0.90 mm, complete all as specified and as directed.
M&L for TMT bars 5 mm dia and over upto and including 10 mm dia in stirrups, spacers and binders cut to length , bent to shape required as in reinforcement and binding with MS wire (annealed) not less than 0.90 mm dia complete all as specified and directed .
M&L for formwork to sides of concrete foundations, footings, bases of column, raft and raft beams, side and soffit (if any) for foundation and plinth beams etc, vertical or to batter for fair finished surfaces complete all as specified and directed.
M&L for formwork to side of pillars, posts, struts, piers, columns for fair finished surfaces complete all as specified and directed.
M & L for RCC 1:1½:3, type A1 (using 20mm grade stone aggregate) Foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete complete all as specified and directed.
M & L for RCC 1:1½:3, type A1 (using 20mm grade stone aggregate) as in Columns, pillars, piers, posts and struts complete all as specified and as directed.
M&L for preparation of new plastered surfaces and applying two coats of cement base paint over a coat of alkali resistant primer complete all as specified and directed.
M&L for applying two coats of synthetic enamel paint over a coat of Red oxide, zinc chrome primer to new steel surfaces of any description over 10 cm width or girth including preparation of surfaces all as specified and directed by Engineer-in-Charge.
M&L for applying two coats of synthetic enamel paint over a coat of Red oxide, zinc chrome primer to new steel surfaces of any description not exceeding 10 cm width or girth including preparation of surfaces all as specified and directed by Engineer-in-Charge.
M&L for applying one coat of synthetic enamel paint to old decorated steel surfaces of any description over 10 cm width or girth including preparation of surfaces all as specified and directed by Engineer-in-Charge.
M&L for applying one coat of synthetic enamel paint to old decorated steel surfaces of any description not exc 10 cm width or girth including preparation of surfaces all as specified and directed by Engineer-in-Charge.
Provind and laying 9 layer synthetic flooring for badminton court, based on concrete surfaces as per manufacturer's instructions in the following steps :- (a) ARYPATCH :- 100% Acryflex Unic Floor (KDF) based emulsion shall be applied to repair cracks on concrete pavement. (ii) PRIMER :- 100% Acryflex Unic Floor (KDF) based emulsion shall be applied to improve bond of acrylic court system to the concrete surfaces. (c) RESURFACER : 2 Acryflex Resurfacer 367.3 for filling and smoothing concrete surfaces in preparation for Acryflex ITF approved Badminton Court system and alfo for filling the surface chips, voids and concealing repairs while providing a smooth surface for colour coating. (d) CUSHION COAT :- 3 layers of Acyflex Unic Floor (KDF) cushion for concrete surfaces in preparation for Acryflex ITF approved system. (e) ULTRA CUSHION COAT :- 2 layers of Acryflex Unic Floor (KDF) cushion for concrete surfaces in preparation for Acryflex Unic Floor (KDF) cushion for concrete surfaces in preparation for Acryflex ITF approved system (f) PRE-COAT :- 2 layers of Acryflex Unic Floor (KDF) based textured top coat, suitable for colour coating to Badminton court surfaces. (g) OVERLINE :- 100% Acryflex Unic Floor (KDF) based high hidinh line paints (MAKE: Asian Flooring India Pvt Ltd or equivalent makse as approved by GE) (NOTE: The work shall be got carried out by authorised workmen/applicator of the manufacturer)
Dismantling of old chain link wire mesh fencing including flat iron, ms round supporing bars, bracing bar etc complete all as specified and directed.
Dismantling posts or struts (wood, steel or RCC), any section, embedded in natural ground, including taking out embedded portion and making good disturbed ground, complete all as directed.
Dismantling posts or struts (wood, steel or RCC), any section, embedded in concrete, brick work, masonry etc., including taking out embedded portion and making good disturbed ground, complete all as directed.
Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and directed.
Demolition of brick work or stone boulder masonry built in cement mortar including all quaries, arches pillars etc and removing off the site complete all as specified and directed.
Demolition of cement concrete (unreinforced) in ground floors and pavings not exc 150 mm thickness (above or below groud level) and removing off debris from the site complete all as specified and directed.
Taking down cement plaster from brick or concrete surfaces of any description including racking out joints, hacking for key, scrubbing down with water etc complete all as directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises, complete all as directed.
S&F in repairs galvanized 2 strand steel barbed wire fencing conforming to IS : 278, with 2.24 mm dia. barb wire conforming to IS : 280 with zinc coating as per IS : 4826, barbed with 2 mm dia. barbs at 75 mm spacing and straining and fixing to any type of standard rails/RCC fencing posts straining bolts, including securing or tying at crossing with and fixing of galvanized mild steel wire, staples or steel pins etc., incl dismantling of existing barbed wires complete all as specified and directed. (Note: - Each line of wire will be measured)
Re-straining, resecuring incl making good barbed wire, any type and re-fixing to any type of standard rails/RCC fencing posts straining bolts, including securing or tying at crossing with and fixing of galvanized mild steel wire, staples or steel pins etc complete all as specified and directed. (Note: - Each line of wire will be measured)
M & L for heavy duty ceramic floor tiles of size 300 x 300 x10mm thick in floor etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade complete including 20mm thick screed bed in cement mortar 1:6 complete all as specified and directed. (MAKE : JOHNSON, Model : Endura or equivalent item in other makes listed in the tender)
M&L for PCC, 75 mm thick, 1:2:4 type B2 using 40 mm graded stone aggregates as in sub base of floor, finished even and fair complete all as specified and directed.
M&L brick work with fly-ash bricks, straight or curved on plan exc 6m radius buit in cement mortar 1:4 complete all as a specified and as directed.
M&L for continuous brick edging; with fly ash bricks, with width equal to the width of the brick; laid dry on end vertically complete all as specified and directed.
M&L 15 mm thick rendering in cement mortar (1:6) to brick or concrete wall surfaces, finished even and smooth without using extra cement all as specified and as directed by the Engineer-in-Charge.
M&L for rendering 20mm thick built in cement mortar (1:4) in two layers (10mm thick each layer) on inclined surfaces of moat wall, finished even & fair complete all as specified and directed.
S&F in repairs precast cement concrete jallies, type B-0 ,1:2:4 ( using 12.5 mm graded broken stone aggregate) 40mm thick, including all mouldings but excluding frame, set in cement mortar 1:4, complete all as specified and as directed.
M&L for providing precast cement concrete (1:2:4) type B1 using 20 mm graded aggregates set in cement mortar 1:4 as in window or door cills, lintels, bressumers, steps, columns, posts, etc. with plain fair faces, including chamfers, weatherings, throating etc and setting in mortar complete with joints to match complete all as specified and directed.
M&L granite (of any type) work, 18-20 mm thick (table rubbed and polished) in steps, jambs, pillars, window cills, cooking platforms, urinal partition and like in cement mortar 1:4 including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite and making moulds on edges laid over and including 20 mm thick screed bed in cement mortar 1:6 complete all as specified and directed.
-ditto- but as in vertical surfaces over and including 10 mm thick screed bed in cement mortar 1:3)
Supply and Fixing PVC solid wall lining consisting of 5 mm thick single side prelam PVC sheet inclusive of solvent cement and fixing at site on PVC frame as per manufacturer’s specification and instruction and as directed by the Engineer-in-Charge.
Supply and Fixing 5mm thick PVC sheet fillet of width 35 mm for wall paneling inclusive of fixing on to wall to make PVC frame as per specification and drawing complete all as specified and directed
SCHEDULE 'A' PART-II (E/M WORKS)
M&L for sand cushioning/sand covering for underground cable protection and consolidated and compacted with clean dry sand complete all as specified and as directed. (NOTE: Punned thickness shall be measured for payment)
M&L bricks with sub class 'B' locally available laid in trenches above sand cushioning for cable protection complete all as specified and as directed.
Supply and fix Steel tubular swaged poles complete with cast iron base plate, finial taper plug, bolts, nuts & screws fixed with MS clamp 40 x 6 mm and 2 set with nut & bolt as specified type 410 SP-31 (9 Meter long) duly painting with two coats of aluminium paint over a coat of red oxide primer on exposed surface and one coat of black bituminious paint on embedded surface and making good disturbed surface complete all as specified and directed. (Note: Earth work , PCC foundation & coping concrete shall be measured and paid seperately under respective items.
Supply and fix 40 mm bore galvanized iron pipe (light grade) with all fittings, laid in trenches or under roads/ flooring /culverts complete all as specified and as directed by the Engineer-in-charge.
Supply and fix 50 mm bore galvanized iron pipe (medium grade) with all fittings, laid in trenches or under roads/ flooring /culverts complete all as specified and as directed by the Engineer-in-charge.
Supply, Laying and testing XLPE insulated, screened PVC bedded, galvanised steel strip armoured heavy duty electric power cable 1100 Volts grade with stranded aluminium conductor cable, of size 2 core 10 sqmm laid in trench or fixed to wall/passing through pipe/pole complete all as specified and directed. (Note :- Necessary earth work to be measured and paid separately)
M&L for cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling hole for bolts, in any shape of size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of aluminium paint all as specified and as directed.
S&F polycarbonate junction box with metric knockouts, dust / water proof and with IP 66 protection for mounting on the street light pole of size 180 mm x 130 mm x 77 mm with bakelite terminals (05 Nos), suitable for 10 Sqmm cable complete with suitable size cable gland and locknut fixed to pole with flat GI clamp of size 30 x 5 mm (02 Nos per pole), with suitable size nuts bolts & washers complete all as specified and directed. (MAKE : HENSEL, Cat No. KF 1010 B or equivalent model in SPELSBERG / SCHNEIDER / RITTAL)
S&F PVC insulated multistranded copper conductor wire, 2.5 sqmm 3 core, round flexible for connection of light fittings complete all as specified and as directed.
S&F in repairs LED Flood Light fitting, of 150 watt capcity, in high pressure die cast aluminium housing with prismatic polycarbonate modular secondary lens optics with integrated constant current electronic driver and toughened glass cover, IP66 grade ingress protection, impact resistance IK07 complete all as specified and directed and complying with the following specifications:-. (a) minimum system efficacy 120 lumen/watt (b) CRI not less than 70, (c) THD < 10% (d) Power factor not less than 0.90 (e) having in built short circuit and surge protection upto 4 kV (f) having 10 KV external surge protection (g) colour temperature not less than 5700 degree K (h) life not less than 50000 hours of operation
S&F SPN DB, IP 43 protection, double door (Premium Quality), 240 volts, 4 way, with 100 Amps copper Bus Bar complete all as specified and directed. (MAKE : L&T, Cat No. DBSPN004DD / LEGRAND, Cat No: 507610 / ABB, Cat No. E-SHC M4 / SCHNEIDER, Cat No. NBKRENSNDD04 / HAGER, Cat No: VYS04D)
S&F MCB (premium quality), 'C' series, SPN, 32 Amps, breaking capacity 10KA complete all as specified and directed. (MAKE : L&T / LEGRAND / SCHNEIDER / ABB / PANASONIC / HAGER)
S&F MCB (Premium Quality), 'C' series, single pole, 6 to 32 Amps, breaking capacity 10KA complete all as specified and directed. (MAKE : L&T / LEGRAND / SCHNEIDER / ABB / PANASONIC / HAGER)
Materials and Labour for earthing complete with galvanized steel earth plate electrode 600 mm x 600 mm x 6.0 mm thick buried directly in ground vertically to a depth not less than 2.25 meter deep below ground level with top edge earth plate at a depth not less than 1.5M below normal ground level connected to galvanized iron strip 25 X 4 mm (upto 7.5 metres) by means of bolts, nuts check nuts and washers of galvanized steel and connected to main switch board or main control board as directed and including provision of concrete pit in PCC (1:3:6) type C1, pre-cast RCC (1:2:4) type B1 cover slab 45 cm x 45 cm x 5 cm reinforced with 8 mm dia. TMT bars @ 150 mm centre to centre both ways, with one handle for lifting made out of 8 mm dia MS bar, provision of funnel, wire mesh, 20 mm bore galvanized steel tubing (Medium grade) for watering, charcoal or coke and salt in alternate layers, 40 mm bore galvanized steel tubing medium grade for protection of earth lead connection, necessary excavation and earth work in any type of soil and including necessary testing complete all as shown in Figure 15A of IS 3043 :1987, complete all as specified and directed.
PRABIR TRADERS
dutta and dutta
SHEIKH ENTERPRISE
RAJ ENTERPRISE
MS HORIZEN
GHOSH ENTERPRISE
JOY RAM ENTERPRISE
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .