| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹25.0 LAccepted-AOC | L1 | Accepted-AOC 2496460.00 | |
| 2 | L2₹26.6 L+₹1.6 L (6.45%)Rejected-Finance 23 8 SANJAY COLONY AKHNOOR 181201 JAMMU KASHMIR | AKHNOOR | JAMMU | JAMMU KASHMIR | 181201 | L2 | Rejected-Finance DUE TO NOT BEING L1 AND REASONABLE | |
| 3 | L3₹27.8 L+₹2.9 L (11.5%)Rejected-Finance | L3 | Rejected-Finance DUE TO NOT BEING L1 AND REASONABLE | |
| 4 | L4₹27.9 L+₹2.9 L (11.8%)Rejected-Finance 12 138 MANAS NAGAR BARA REWA POST OFFICE BANSAGAR COLONY REWA | REWA | REWA | MADHYA PRADESH | 486001 | L4 | Rejected-Finance DUE TO NOT BEING L1 AND REASONABLE |
Tender Value
₹28 L
EMD Value
₹56,000
Closing Date
7 Dec 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (SOUTH) AKHNOOR
GE (SOUTH) AKHNOOR C/O 56APO
PROVN OF TOILET CUM BATHROOM BLOCK AND PROVN OF GUARD ROOM WITH DOUBLE STOREY SENTRY POST WITH ALLIED INFRASTRUCTURE WITHIN AOR OF AGE B/R-II UNDER GE (SOUTH) AKHNOOR
2022_MES_559956_1
GES/AKH-23/2022-23
Open Tender
Civil Works
Lump-sum
180 days
GE (SOUTH) AKHNOOR
MES EN-LISTED CONTRACTOR WITH CLASS D AND ABOVE WITH CATEGORY a(i)
12 documents required · 12 mandatory
₹500
GE (SOUTH) AKHNOOR
₹56,000
20 Feb 2023
27 Oct 2022
9 Dec 2022
27 Oct 2022
7 Dec 2022
24 Nov 2022
Amount
Total amount of Schedule 'A' Part- I (Building Work) Note:This Schedule is not pre-priced by MES and the Pre-priced rate indicated as Rs 0.00 under col 5 signifies this fact only.
Provn Of Toilet Cum Bathroom Block In SUTC COY alongwith allied infrastructure, Complete all as specified and as shown on Drawings. (Building Work)
Provn of Guard Room With Double Storey Sentry Post alongwith allied infrastructure, complete all as specified and as shown on drawings. (Building Work)
The Schedule'A'- Part II to IX are pre-priced by MES.
Total Amount of Sch'A'-Part-II (INTERNAL WATER SUPPLY WORKS )
Total Amount of Sch'A'-Part-III (INTERNAL ELECTRIFICATION WORK)
Total Amount of Sch'A'-Part-IV (SEWAGE DISPOSAL WORK)
Total Amount of Sch'A'-Part-V (AREA DRAINAGE WORK)
Total Amount of Sch'A'-Part-VI (ROAD / PATH / INTERLOCKING TILES WORK )
Total Amount of Sch'A'-Part-VII (SITE CLEARANCE WORK )
Total Amount of Sch'A'-Part-VIII (EXTERNAL WATER SUPPLY WORK)
Total Amount of Sch'A'-Part-IX (EXTERNAL ELECTRIFICATION WORK)
Sch 'A' Part-X (MISC ITEMS) Note : This schedule is not pre priced by MES and the pre priced rate indicated as "`. 0.00" under Col.5 signifies this fact only.
Septic tank for 25 users LLDPE (Linear Low Density Polyethylene) with upflow filter including media type with vent pipe, cowl etc. designed to carry sewage and sullage water, including excavation in any type of soil as per size of tank , PCC 1:4:8 Type D-2(using 40mm graded crushed stone aggregates)as bed concrete, lowering the septic tank and filling with water and return/filling with mix of coarse sand and Bajri around the septic tank and do inlet and outlet pipe connection etc complete all as specified and as directed. Make: Sintex /Comfort polymers/ Polycon/Diplast.
Construction of soakage well of 1.8 mtrs dia and 3.0 mtrs in depth, in any type of soil including plain cement concrete M-10(1:3:6), type C-2 (using 40mm graded crushed stone aggregates) in foundation and honeycombed brick masonry in cement mortar 1:4 and reinforced cement concrete cover slab, M-25, type A-1 (using 20mm graded crushed stone aggregates), complete all as specified and as shown in drawing. Drawing No- CE/TD/1202/03 sheet 1/2 and 2/2 dated 09.10.03 revised 14.10.14 and 11.05.07.
Construction of soakage well of 1.2 mtrs dia and 3.0 mtrs in depth, in any type of soil including plain cement concrete M-10(1:3:6), type C-2 (using 40mm graded crushed stone aggregates) in foundation and honeycombed brick masonry in cement mortar 1:4 and reinforced cement concrete cover slab, M-25, type A-1 (using 20mm graded crushed stone aggregates), complete all as specified and as shown in drawing. Drawing No- CE/TD/1202/03 sheet 1/2 and 2/2 dated 09.10.03 revised 14.10.14 and 11.05.07.
T bulb curve, 12 Watt LED base B22 cool day light, complete all as specified and as directed by Engineer-In-Charge.
S&F 4 feet highly engineered plastic body suitable with fully diffused diffuser for general lighting in areas. The luminaire should have a color consistency SDCM < 5, CRI > 80 and CCT of 6500K. The luminaire shall be compliant with IP20 and IK02 classification. Luminaire shall be designed to emit at least 1800 nominal lumens and an outstanding solution efficacy of atleast 100 lumen/watt and maximum system wattage of 18 Watts. The electronic driver used shall have a power factor >0.95 and THD <20% with 4 KV internal surge protection. Manufacturer shall have inhouse lab approved by NABL or ministry of science of govt of India. LM 79 and LM80 reports need to be submitted from a NABL/UL accredited lab to verify above parameters and including suitable size and length of flexible copper wire and making the connection, complete all as specified and as directed by Engineer-In-Charge. Make : Bajaj cat part No BCLSB 18 WH or Equivalent makes in Wipro/Philips. Warranty certficate for 2 years to be provided by Employee of Organization of Terittory.
S&F high-quality integrated LED Street Light with a minimum system lumen of 4950 Lm and system wattage not exceeding 45W with a nominal efficiency 110 lumen/watt. CCT of 5700K with SDCM of < 5 and CRI >70. The housing should be of non-corrosive high-pressure die-cast aluminum with heat resistant toughened clear glass to with stand extreme environments with PF > 0.95. Lifetime of 50K hours @L70.The Ingress protection should be minimum IP 66 with an IK rating of 07. The Luminaire should have 4KV internal 10KV external surge protection in the Luminaire.Manufacturer shall have inhouse lab approved by NABL or ministry of science of govt of India. LM 79 and LM80 reports need to be submitted from a NABL/UL accredited lab to verify above parameters and including suitable size and length of flexible copper wire and making the connection including House service bracket for mounting light fittings House service bracket any type complete with 1.50mtr long galvanised iron pipe 40mm dia medium grade, bent to required shape including mild steel clamps of flat iron 40x6mm, hook, stay, nut, bolt and washer including painting with two coats of synthetic enamel paint over one coat of red oxide primer , complete all as specified, complete all as specified. Make : Bajaj cat part No ENXT P 54L WH PO PC SD or Equivalent makes in Wipro/Philips. Warranty certficate for 2 years to be provided by Employee of Organization of Terittory.
S&F Ceiling fan, mettalic, sweep 1200mm, with BLDC Motor, high speed, inclduing necessary fitting/fixtures such as Hook and clamps etc including connectig wire of suitable size and length from ceiling rose to fan connector, having BEE Star Rating- 5 Star, Rated Power Input in Watt 28±10%, Rated Speed in RPM 345±10%, Rated Air Delivery in CuM/ Min- 220 Minimum, Service Value CMM/W 7.85 Minimum No of Speed 5 , Insulation Class- E, Temperature Rise @ Rated Voltage 25 degree Celcius (Max) by winding resistance measurement at an ambient 30 degree Celcius, High Voltage Test Withstands 1.5KV, Insulation resistance Above 2 MΏ, Type of Ball Bearings Single row deep groove ball bearings of 6202 sizes Top & Bottom Cover should be of aluminium, Type of Lubricant Used Lithium Based – Shell Alvania RL3, Material of Blade Aluminium, BEE Certification, Material of Canopies- Polypropylene, complete all as specified and as directed. Make: BAJAJ Model No Energos 28 or Equivalent Makes in Havells / Crompton Greaves/ Usha / Orient Electric energy star
Exhaust fan, mettalic, sweep 250mm, superior rating for energy saving, mettalic blades, copper wounded motor complete including making necessary connecting wire of three core felixible copper cable of size 23/0.0076 of required length from ceiling rose to connector to exhaust fan incl and nut bolts, washers, complete all as specified. Make: Havells cat part No- Ventil Air - DB NEO/ Crompton Greaves/ Usha/ Bajaj/ Orient.
Exhaust fan, mettalic, sweep 300mm, superior rating for energy saving, mettalic blades, copper wounded motor complete including making necessary connecting wire of three core felixible copper cable of size 23/0.0076 of required length from ceiling rose to connector to exhaust fan incl and nut bolts, washers, complete all as specified. Make: Havells cat part No- Turbo Force SP/ Crompton Greaves/ Usha/ Bajaj/ Orient.
Water heater storage type (geyser), wall hanging, capacity 25 Litres, Energy saving high density PUF insulation, BEE rating Five (5) Star, 230 Volts, single-phase, 50 Hz AC, rated power input not less than 1000Watt, complete all as specified. Make: Havells cat part No- Monza DX (GHWAMGSIB025)/ Bajaj cat part No-Calenta/ Jaquar cat part No- EPM-WHT-V025 (Elena Prime)
Industrial Bulkhead luminaire environmental friendly, ultra modern, energy saving, surface mounted, decorative oval bulk head edge-lit LED luminaire comprising of high brightness LED lamp 10 Watt and fixing in repairs with materials such as clamps, nuts, bolts, washers etc completed, complete all as specified and as directed by Engineer-In-Charge. Make: Havells Cat Part No- Rugby Neo NFT10WLED860SSYMTOPC or equivalent in Philips/ Bajaj.
S & F Inverter LED Batten with opal diffuser, IP20, battery back-up & functioning as per product TDS, 20 Watt, complete with all accessories with twin core twisted flexible copper conductor cable with suitable size all as specified and directed. Havells cat part No- PRIDE PLUS INVERTER BATTEN LHEXACP7FN1W020 or Equivalent Makes in Crompton/Philips/Osram.
Drilling, cutting and tapping CI/ DI/ GI water mains (in position) the existing pipe of 50mm for branch connections including inserting tee of 50X50X25mm size with all fittings complete all as specified and as directed by Engineer-In-Charge.
M/s Sekinder Paul Sharma
M/s J V Construction
RAMA CONSTRUCTION COMPANY
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .