| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹32.5 LAccepted-AOC | L1 | Accepted-AOC Being L1 bidder | |
| 2 | L2₹35.2 L+₹1.8 L (5.25%)Rejected-Finance | L2 | Rejected-Finance Being other then L1 bidder | |
| 3 | L3₹35.5 L+₹2.1 L (6.28%)Rejected-Finance R O NAUSHERA DISTT RAJOURI J K 185151 | NAUSHERA | RAJOURI | JAMMU AND KASHMIR | 185151 | L3 | Rejected-Finance Being other then L1 bidder | |
| 4 | L4₹36.4 L+₹3.0 L (9.09%)Rejected-Finance | L4 | Rejected-Finance Being other then L1 bidder | |
| 5 | L5₹36.9 L+₹3.5 L (10.6%)Rejected-Finance | L5 | Rejected-Finance Being other then L1 bidder |
Tender Value
₹42 L
EMD Value
₹84,000
Closing Date
24 Oct 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE 862 EWS
GE 862 EWS, RAJOURI
SPECIAL REPAIR TO BLDG NO T-40, T-43, T-44, T-47, P-1 AND P-2 INCLUDING CERTAIN MINOR WORK OF AGE BR DETT A AND AGE EM UNDER GE 862 EWS
2023_MES_618967_1
GER-46/2023-24
Open Tender
Civil Works
Item Rate
180 days
GE 862 EWS
As per tender documents
9 documents required · 9 mandatory
₹500
GE 862 EWS
₹84,000
Yes
1 Dec 2023
15 Sept 2023
26 Oct 2023
15 Sept 2023
24 Oct 2023
10 Oct 2023
16 Sept 2023 - 26 Sept 2023
Amount
Sch 'A' Part-I (B/R works) Demolition of cement concrete (unreinforced) in ground floor and paving n exc 15 cm thickness below or above the ground level, including dismantaling old tiles complete all as specified and directed.
M&L for glazed ceramic coloured tiles of size 350x250x7mm / 450x350x7mm thick, (premium quality) on vertical surface of wall such as dado, skirting, riser etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the colour of tiles, laid over and including 10mm thick rendering in cement mortar 1:4 including dismantaling old tile complete all as specified and as directed.
M&L for non skid ceramic coloured tiles 7 to 8 mm thick (premium quality) Square/rectangular, area of each tile exceeding 0.06 sqm but n.exc 0.11 sqm in floors etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match the colour of tiles, laid over and including 15mm thick screed bed in cement mortar 1:4, complete all as specified and as directed..
M&L for vitrified tiles light shade (premium quality) 9-10 mm thick (square/ rectangular) polished, area of each tiles n exc 0.36 sqm in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the surface, laid over and including 15 mm thick screed bed in cement mortar 1:4 complete all as specified and directed.
All as per Srl item no 4 here-in-before but in skirting including rendering 10mm thick in CM 1:4
M&L for 25mm thick plain cement concrete 1:2:4, type B-1 using 20mm graded stone aggregates as in sub base of floors tiling, complete all as specified and directed.
M&L for 50mm thick plain cement concrete, type C-2, 1:3:6 (using 40mm graded crushed stone aggregate) as in plinth protection, laid in slope 1:12 from outer edge of the wall, finished even and fair, laid in alternate bays including providing 6mm wide joints throughtout thickness of plinth protection in concrete bays and in between walling and plinth protection, joints filled mastic filling comprising of one part of heated bituminous 85/25 and 3 parts of sand (all by weight), complete all as specified and directed.
Taking down chowkats or frames with shutters (without taking off shutters from frames) area exceeding 1.50 square metre and not exceeding 4.0 square metre each, complete all as specified and directed.
Taking down chowkhats or frames (without taking off shutters from the frames) n.exc 1.5 Sqm each and removing from site, complete all as specified and directed.
Demolition of brickwork or stone / boulder masonry, built in cement mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stone-work and precast concrete articles complete all as specified and directed.
M&L for stone walling of random rubble masonry, uncoursed, well bonded, bedded and soilidly hearted, built in cement mortar 1:6, complete all as specified and directed.
Description all as per srl item No. 11.00 above but except stone. NOTE: Old stone retrieved from demolition shall be used.
S&F for 4mm thick designer ceiling board in ceiling fixed with screw as per manufacturers instructions, laid over and including hot dipped galvanised iron in post grid with 24mm wide T section exposed flanges which shall be powder coated white. The frame work shall comprise of main runner made from 0.33 mm thick galvanised steel sheet of size 24 x 32 x 300 mm spaced at 1200 mm centres securely fixed to the structural soffits by approved hangers at 1200mm maximum centres. Hangers of GI wire 4 mm dia to be fixed by approved rawl plug or hanged with existing truss members. The last hanger at the end of each main runner shall not be greater than 450 mm from adjacent wall flush fittings of 1200 mm long screws Tee with (double stiching) to interlocked between main runners at 600 mm centre to centre from 1200 x 600 mm modules cross tee longer than 600 mm modules to be formed by fittings 600 mm long cross tee, tee perimeter wall angle shall be of 0.45 mm thick galvanised steel of size 19 x 19 mm and 300 mm long of white colour all as per insturctions including dismantling of existing ceiling board etc, complete all as specified and directed.
Dismantling of timber scantling 40 Sqcm and over in section, in any position as in unframed or framed work complete all as specified and directed.
S&F for roof truss (framed) trussed purlins, crane gantries rails and fastenings and heavy bracket framing (beam, tee, angle, cnanelor flat section gusset plate) including distance piece, cleats etc, complete all as specified and directed.
Dismantling of plain or corrugated steel sheeting, any gauge, thickness including Nanital or similar pattern roof covering complete all as specified and directed.
S&F for Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of approved colour having tensile strength 550 MPa as in roof covering/cladding to wall fixed with self tapping screws including side and end lap as per manufacturer’s instructions, complete all as specified and directed.
S&F for Pre-painted galvalume aluminium zinc coating GI based plain sheet 0.50mm thick of approved colour having tensile strength 550 MPa as in ridges, hips, valley gutters fixed with self tapping screws including side and end lap as per manufacturer’s instructions, complete all as specified and directed.
Taking down cement plaster, any description on any walls etc including raking out joints, hacking for key, scrubbing down with water etc complete all as specified and directed.
M&L for rendering 20 mm thick in cement mortar 1:6 on stone masonry surface, finished the surface even and smooth without using extra cement, complete all as specified and directed.
M&L for rendering 20 mm thick in cement mortar 1:4 on stone masonry surface (external surface), finished the surface even and smooth without using extra cement, complete all as specified and directed.
Demolition of reinforced cement concrete of any description and in any position not otherwise specifically provided for RCC beam & slabs, complete all as specified and directed.
M&L for reinforced cement concrete 1:11/2 :3, type B-1 (using 20mm graded crushed stone aggregated) as in beams, deck slabs, chajjas and in shelves and like, complete all as specified and directed.
M&L formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilivers, shelves, including supports, overhangs etc also splays between floors and beam etc, complete all as specified and directed.
M&L for mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips, complete all as specified and directed.
S&F for pressed steel door frame of size 125x60 mm with one or more rebates including necessary fixing lugs, hinges, lock and strike plate etc including back filling to chowkhats in PCC 1:3:6 type C-1 using 20mm graded stone agregate complete all as specified and directed.
S&F for factory made 2nd class hard wood 35 mm thick plain framed panelled shutters (two panel) with lock rail and panel of 9mm BWP commercial ply or 12mm veneered particle board with commercial veneering on both faces. The size of rail and stile as per IS : 1003 (part-I) kiln seasoned and chemically pressure treated complete all as specified and directed.
S&F for factory made 35 mm thick 2nd class hard wood glazed and skelton shutters open rebated and prepared to receive glass, gauze etc (without sash bars) edges of framing plain, chamfered or rounded fitted with cut and mitred beads for securing glass, etc sizes of members of shutters as specified in SSR Part I, Section 8, clause 8.24 (a); supplied and fitted to chowkhats complete all as specified and directed.
S&F for factory made MS tubular box type window of MS rolled steel section confroming to IS-1038 and shall be ISI marked manufactured by ISI approved manufacturer opnable frames shall be facbricated of section as approved by Engr-in-Charge corner welded to form a solid fused welded joint handles shall be of Z section welded with openable frame box steel section (consisting of both shutter galzed shutter and gauge shutter complete) used in outer frame shutter frame and central frame shall be ERW section of 16 gauge with fixing lugs to be fixed as per provision of IS-1038 except that top lugs shall not be provided all shutters of windows shall be provided with 4 Nos friction free hinges 2 Nos 75mm tower bolts to each leaf of window one at top and one at bottom welded on 3mm thick steel sheet piece of suitable size which shall be in turn welded to Z section steel window to provide suitable arragement of using tower bolt and 1 nos bow handle in each shutter galzed shutter and gauged shutter of window mild steel casement stays 300mm with hinged joint and two plates with studs complete all as specified with all fittings and fixtures without galzing bars, 3mm sheet glass in galzed shutter and GI wire mesh of 0.56 nominal dia and average width of aperature 1.18 mm in gauged shutter etc complete all as specified and directed.
S&F for chimney bars (straight or camber) bearing bars, tongues or water bars for window frames, window guard bars, plain let in and fixed independently in wooden frames, L or T section supperts for shelves etc and similar articles conforming to Fe-290 Gde E-165, including a coat of red oxide primer as per complete all as specified and directed.
S&F for 300mm long ordinary rat tail rod pattern springs including roller plate, complete all as specified and directed.
S&F for second class hard wood small fitting such as brackets of any type latch and hings blocks, shaped door and window stops and the like, including all necessary labours articles n exc 200 cm each, complete all as specified and directed.
M&L for plain cement concrete type B-1, 1:2:4 (using 20mm graded stone aggregate) as in apex stone, coping, benching, hold fasts, water troughs, bed block, surface channel, PCC cill and the like including weathering, slightly rounded or chamfered angles and throating including necessary form work, complete all as specified and directed.
S& F for galvanised mild steel wire cloth, 0.56mm nominal dia of wire and average width of aperature 1.18mm and fixed with tinned tacks, or galvinsed wire staples , complete all as specified and directed.
S&F for extruded aluminium alloy handles size 150 mm fabricated type anodised (ISI marked), complete all as specified and directed.
S&F for aluminium anodized barrel tower bolts 200 mm long of extruded section (ISI marked) ,complete all as specified and directed.
M&L for 300mm long (lenth of bolt) aluminium alloy, anodised, sliding door bolt with hasp, stapl (bolt type) and fixing clips of sheets, cast or extruded section and fixing bolts and sliding bolt of extruced sections or cast aluminium alloy anodised (ISI marked) complete all as specified and directed.
M&L for preparation of new steel surface exc 10 cm width or girth and applying two coats of synthetic enamel paint, over a coat of red oxide primer, complete all as specified and as directed by Engr-in-Chagre.
M&L for preparation of new wooden surface exc 10 cm width or girth and applying two coats of synthetic enamel paint, over a coat of pink primer, complete all as specified and as directed by Engr-in-Chagre.
M&L for preparation of new / old plastered sufrace of wall are applying two coats of cement base paint, complete all as specified and directed by Engr-in-Charge.
M&L for preparation of new plastered surfaces of walls and applying two coats of distemper oil emulsion over a coat of wall care putty, complete all as specified and directed.
M&L for solid PVC door frame of size 50mmx47mm made out of 5mm plain colour PVC sheet reinforced with MS Square tube, complete all as specified and directed.
M&L for factory made solid panel PVC door shutter 30mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails, M.S frame shall be covered with heat moulded plain colour PVC 'C' channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail : Panelling of plain colour PVC sheet to be fitted in the M. S . frame welded/sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, supplying & fixing in the frame at site as per specification & drawing mentioned in SSR Part-II 2020, complete all as specified and directed.
S&F for 75mm long butt hinges, type C-2, aluminium anodised, extruded aluminium alloy with galvanised mild steel hinge pin, complete all as specified and directed.
Taking down GI tubing of 15 mm dia and connection and incl cleaning for refixing or removal , complete all as specified and directed.
Taking down GI tubing of 20 mm dia and connection and incl cleaning for refixing or removal , complete all as specified and directed.
S&F for 15 mm bore galvanised iron GI tubing medium grade with all fittings such as bends, socket, tee, elbow, union, nipple, short pieces and fixed to walls, ceilings or laid in floors etc, complete all as specified and directed.
S&F for 20 mm bore galvanised iron GI tubing medium grade with all fittings such as bends, socket, tee, elbow, union, nipple, short pieces and fixed to walls, ceilings or laid in floors etc, complete all as specified and directed.
Fixing only 15 mm bore galvanised iron GI tubing medium grade with all fittings such as bends, socket, tee, elbow, union, nipple, short pieces and fixed to walls, ceilings or laid in floors etc, complete all as specified and directed.
Fixing only 20 mm bore galvanised iron GI tubing medium grade with all fittings such as bends, socket, tee, elbow, union, nipple, short pieces and fixed to walls, ceilings or laid in floors etc, complete all as specified and directed.
S&F in repair for 15mm bore bib tap cast copper alloy, chromium plated, fancy type, with crutch or butterfly handle, screwed down for iron pipe or for brass ferrule complete all as specified and directed.
S&F in repair for 20mm dia ball valve high pressure of PTMT with epoxy coated aluminium roa and high density plastic ball screwed for iron pipe and fixed (min wt 20mm -210 grms), complete all as specified and directed
S&F in repair for 15mm bore stop valve cast copper alloy screwed down, high pressure with crutch or butterfly handle, chromium plated, fancy type, screwed both ends for iron pipe or for unions and fixed, complete all as specified and directed.
S&F in repair for vitreous China water closet (squatting pan) Orrisa pattern 580x440 mm size pan, white, with front or back inlet with integral 'foot rests including provn of PCC bedding in 1:2:4 including connections to trap and flushing cistern with flush pipe and making good to disturbed floor complete all as specified and directed.
M&L for 110mm bore PVC (SWR) 'P' trap, complete all as specifed and directed by Engr-in-Charge.
S&F in repair 10 ltrs capacity (PVC), valve less, syphonic action type, flushing cistern, low level, white, with inlet, ball valve, float and handle including brackets, complete all as specified and directed.
S&F for PVC connection 15 mm x 450 mm including PTMT nuts at both ends screwed for iron pipe of 15 mm bore, complete all as specified and directed.
S&F in repair for 20mm bore stop valve cast copper alloy, screwed down, high pressure with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed, complete all as specified and directed.
S&F 75mm bore PVC (SWR) floor trap, plain with grating including jointing with solvent cement and connecting to waste pipe, complete all as specifed and directed.
S&F in repair for 110mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints laid in floor trenches, or in floor or fixed to wall with steel clamps, complete all as specified and directed.
S&F in repair for 75mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints laid in floor trenches, or in floor or fixed to wall with steel clamps, complete all as specified and directed.
S&F in repair for chromium plated brass shower rose of size 125 mm with swivel joints fixing to steel pipes etc. Complete as in repair all as specified and directed.
S&F in repair for chromium plated tubular towel rail 20 mm dia "D" type 60 cm long between flange aluminium anodised including pvc/woooden cleats and fixing with screws, complete all as specifed and directed.
S&F in repair for vitreous China wash basin with pedestal, white, flat back, size 550x 400mm excluding taps, waste chain and plug and porcelan stopper but including brackets, cutting for pinning in ends of bracket or erecting stand, complete all as specified and directed.
S&F in repair for 15mm bore pillar taps, cast copper alloy, with capstan heads, brass chromium plated, screwed down high pressure, with long screwed shanks and fly-nuts, screwed for iron pipe and fixed complete, all as specified and directed.
S&F for 32mm dia waste coupling brass, chromium plated (half or full threaded), fixed to glazed ware sinks / WHB etc with long screwed shank and fly nuts, flange end bedded in red lead cement complete all as specified and directed.
S&F in repair for 100 mm dia grating doom stainless steel with waste hole for waste pipe, complete all as specified and directed.
S&F for rotational moulded polythylene water storage tank (ISI marked) with float valve, plastic lid cover, multy-layered, cylindrical vertical with closed top, hoisted and fixed in position of capacity 1000 ltrs tank and making connections inlcuding suitable GI wash out, over flow, nipple and including 20mm bore ball brass valve with union screwed for iron pipe and fixed, including taking old tank complete all as specifed and directed.
M&L for brick work with sub class 'B' bricks old size straight or curved on plan exc 6 m mean radius, built in cement mortar 1:6, complete all as specified and directed.
M&L for rendering 15 mm thick in cement mortar 1:4 on fair faces of brick or concrete surface finished the surface even and smooth without using extra cement, complete all as specified and directed.
M&L for double charged vitrified tiles light shade (premium quality) 9-10 mm thick (square/ rectangular) polished, area of each tiles exc 0.36 sqm n. exc 0.42 sqm in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the surface, laid over and including 15 mm thick screed bed in cement mortar 1:4 including taking down old tiles complete all as specified and directed.
Dismantling of mild steel or wrought iron work in any position and any description complete all as specified and directed.
M&L for 15mm bore stop valve (concealed type) cast copper alloy screwed down, high pressure with crutch or butterfly handle, chromium plated, fancy type,screwed both ends for iron pipe or for unions and fixed, complete all as specified and directed.
S&F in repair viterous china wash down water closet pan, white (pedestal pattern), one piece complete with flush mounted on EWS including plastic water closet seat, black/white, closed pattern with recessed bottom and cover and mild steel chromium plated or aluminium hinging device, (excluding fixing bolts, flushing cistern and flush pipe), complete all as specified and directed.
M&L for chequered cement concrete tiles of size 30 cm x 30cm x 25 mm thick set, jointed in neat cement slurry in floor and pointed in white or coloured cement to match the shade of tiles laid over and including 15 mm thick screed bed in cement mortar 1:4, complete all as specified and as directed.
M&L for 75mm thick plain cement concrete 1:4:8, type D-2 using 40mm graded stone aggregates as in sub base of floors for tiling, complete all as specified and directed.
M&L for Anodised aluminium frame for doors, windows and ventilators with one or more rebates including joining cleat for fixing etc. complete all as specified and directed.
S&F for anodised aluminium (minimum thickness of power coating 50 micron) door shutters, aluminium section weighing 0.55kg/m including necessary joining cleats, glazing clips, rubber neoprene packing, handles 2 Nos in each door, hinges - 03 Nos, mortice lock, 1 Nos floor door stopper, anodised aluminium snap beading, screws etc. complete all as specified and directed.
M&L for 12mm thick prelaminated particle board, interior grade, prelaminated both side with decorative choice lamination & other side balancing white lamination, fixed to aluminium door, complete all as specified and directed.
S&F for toilet paper holder of brass chromium plated fixed to wall with chromium plated screws, complete all as specified and directed.
S&F in repair for Brass chromium plated Health faucet (ABS Body) for EWC suitable for 15mm dia pipe with 1.25m long flexible tube at ABS wall hook with all fittings complete as in repair all as specified and directed.
M&L for complete removal of existing treatment of walls and applying two coats of cement base paint including preparation of surface, complete all as specified and directed.
M&L for complete removal of existing treatment of wall and applying two coat of distemper oil emulsion paint over a coat of 2mm thick wall care putty, including preparation of surface complete all as speicied and directed.
S&F in repair for drapery rod (Curtain rod) of wooden finishes of 25mm dia fency type complete and hanging hooks/brackets/end caps of length 1.5 mtr to 1.8 each, complete all as specifed and directed.
S&F in repair for 15mm bore brass chromium plated basin mixer for mixing hot & cold water screwed down for iron pipe and fixed, complete all as specified and directed.
S&F for flush shutter solid core construction with block board core and plywood face panels, commercial type on both sides 30mm thick and covered on both sides with decorative face veneer with lapping / frame to match, complete all as specified and directed.
S&F in repair viterous china wash down water closet pan, white (pedestal pattern), including plastic water closet seat, black/white, closed pattern with recessed bottom and cover and mild steel chromium plated or aluminium hinging device and flush pipe including brass CP Jet spray with flexible pipe superior quality (excluding fixing bolts, flushing cistern) complete all as specified and directed.
S&F for 100mm long butt hinges medium weight cold rolled mild steel , complete all as specified and directed.
M&L for preparation of new plastered surfaces of brick / concrete / plastered / unplastered surface of wall, pillars, cornices etc and applying two coat of white wash, complete all as specified and directed.
S&F for 75 mm bore PVC (SWR) vent cowl, complete all as specifed and directed by Engr-in-Charge.
S&F for standing urinal including waste pipe coupling, floor trap, including necessary fittings complete all as specifed and directed Engr-in-Charge.
S&F for steel windows box type with side hung shutters including box type hinges with steel handle, hold fast and steel peg stay, complete with glazing bars, dovetailed or welded complete all as specified and directed.
S&F for 3 mm thick sheet glass ordinary quality and glazing with oil putty / wooden beads in squares n . exc 0.50 sqm in each pane complete all as specified and directed.
M&L in repair for 20mm bore gun metal, gate / globe valve with iron wheel head screwed on both sides for iron pipes complete all as specified and directed.
S&F in repair for soap dish including chromium plated brass screws and wooden cleats complete as specified and directed by Engr-in-Charge.
M&L for plain cement concrete 1:3:6, type B-1, (using 20 mm graded crushed stone aggregates) in surface channels and drains complete all as specified and directed.
Excavating in trenches, n.exc 1.5m wide and n.exc 1.5m in depth in any type of soil for foundation, etc, or for shafts, wells, drain pipes, laying of cables etc, n.exc 10 Sqm on plan and getting out, complete all as specified and directed.
Returning, filling in, trenches including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick ,complete all as specified and as directed.
Removing excavated material ,not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point, complete all as specified and directed.
M&L for brick work with sub class 'B' bricks old size straight or curved on plan exc 6 m mean radius, built in cement mortar 1:4, complete all as specified and directed.
M&L for extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using extra cement, including forms, moulds, mi-tred/stopped ends etc, complete all as specified and directed.
Sch 'A' Part-II (E/M works) Taking down carefully copper/ aluminum point wiring (light, fan, socket or power) complete, including all fittings such as switches, ceiling roses, pendants, regulators sockets etc.) removing material from the site and making good the disturbed surfaces of walls, floor or ceiling etc. to match with existing specifications, complete all as specified and directed.
M&L for point wiring for one light point/fan point controlled by one-one way switch with 1.5 Sqmm. (nominal area) single core FRLS,PVC insulated 1100 Volts, grade multi stranded unsheathed copper conductor unsheathed in and including PVC casing caping medium grade of 25mm width complete with all acessories including PVC sunk box ISI marked for mounting of switches, sockets, fan regulator etc with 3 mm thick plastic laminated sheet as top cover, and 1.5 Sqmm. (nominal area) single core FRLS, PVC insulated 1100 Volts, grade multi stranded unsheathed copper conductor cable as earth wire upto common earth and connected to earth dolly including making good the diturbed surfaces compete all as specified and directed. (Note:- Three run of copper conductor of required size and one run of casing capping measured as one unit and also colour coding of wiring to be followed as red/yellow/blue for phase, black for neutral and green for earth)
Description all as per Serial item No 105 above but for one 3 pin 5 Amp socket outlet on independent board controlled by one 6 amp switch, complete all as specified and directed.
Description all as per Serial item No 105 above but for one 3 pin 5 Amp socket outlet on same board controlled by one 6 amp switch, complete all as specified and directed.
Description all as per Serial item No 105 above but for one 3 pin 15 Amp socket outlet independent with 2.5 sqmm PVC insulated FRLS multistraind copper cable with 2.5 sqmm single core multistraind FRLS copper cable as earthling lead complete all as specified and directed.
M&L for switch piano, flush type single pole, one way 6 Amp, 240 volts complete all as specified and directed.
S&F for socket 2 in 1, 3 pin, 5 amp flush type complete all as specified and directed.
M&L for switch piano, flush type single pole, one way 15 Amp, 240 volts complete all as specified and directed.
M&L for socket outlet 2 in 1, flush type 6 pin, 15 Amp, 240 volts, complete all as specified and directed.
S&F for ceiling rose 3 phase / PVC / polycarbonate isolated body surface bakelite 2 to 3 terminals complete all as specified and directed.
M&L for ceiling fan regulator elctronic, flush type, hum free suitable to control speed of fan from 0 to 100% rotary type five step 240 volts AC complete all as specified and directed.
M&L in repair for LED Tube light fitting, complete with 1x 20 watts, 220V, AC decorative box type with driver, holder in and including LED tube light connection complete prewired and connecting electrically to ceiling rose to fitting using PVC insulated and overall sheathed flexible copper conductor cable of size 0.75 sqmm 3 core and connector block etc and necessary fixing arrangement at any height complete as in repair all as specified and directed.
S&F in replacement for lamp holder insulated body PVC/ Polycarbonate type with back plate suitable for batten/angular/pendent fittings including LED lamp 7 / 9 watt complete all as specified and directed.
S&F in repair for environmental friendly, ultra modern, energy saving, surface mounted, decorative oval bulk head 9/10 watt 6000 K inbuilt LED luminaire comprising of high brightness LEDs, IP54 protection including connecting electrically using cord flexible 3 core PVC insulated over all sheathed with flexible copper conductor of size 0.75 sqmm complete as in repair all as specified and directed.
Taking down ceiling fan, ceiling cable end, dismantling blades and removing fan and blades to store and painting of ceiling fans complete, in situ with synthetic enamel paint by sparying including filling cavities with filler, one coat after cleaning all dust etc including hanging to existing place, completed all as specified and directed.
S&F in replacement for MCB distribution board SPN 8 way, double door 240 volts duly painted with epoxy based powder coated painting suitable for mounting MCB SP/SPN as incomer and outgoings complete with busbar, neutral bar, earth bar connecting cable links with top and bottom removable gland plate with IP 42 protection fixed in wall including chases wall for fixing DB and making good distributed wall surface to match with existing specification complete all as specified and directed. (Note:- MCBs will be measured separately.)
M&L in replacement for MCB single pole & neutral 240 volts any rating from 6 to 40 amps, 'C' series/curve with rupturing capacity 10 KA, including providing thimble for out going cables complete all as specified and directed.
M&L replacement for MCB single pole, 240 volts any rating from 6 to 32 amps, 'C' series/curve with rupturing capacity 10 KA, including providing thimble for out going cables complete all as specified and directed.
Supply,laying, jointng and testing, XLPE insulated, armoured heavy duty electric cable with aluminium conductor 1100 volts grade of size 16 Sqmm 2 core laid in trenches, ducts, pipes, on poles and connection with necessary cables lugs, glands, including taking down old cable complete all as specified and directed. (Note :- Excavation of earth work, removing, returning filling in, sand cushoining, concrete cable cover and protection GI pipe shall be measured and paid separetly and length of cable shall be one length unless otherwise as directed by GE).
M&L for dry sand cushioning to underground cable, provided with a layer 8 cm thick before and 15 cm deep after laying and stretching jointing and testing the cable complete all as specified and as directed. (Note: Punned thickness of sand shall be measured and paid).
M&L for brick covering with width equal to length of brick as mechanical protection to cable using sub class ‘B’ bricks laid flat, size 230mmx115mmx75mm over the cable abutting each other, complete all as specified and as directed.
M&L for earthing complete with galvanized steel earth plate electrode 60cm x 60cm x 6 mm thick buried directly in ground vertically to a depth not less than 2.25 mtr below ground level with top edge of the earth plate at a depth not less than 1.5 mtr below ground level, earth plate surrounded by and packed with 15 cm thick layer of char coal dust and common salt, earth lead GI wire 4.00 mm dia by means of bolts, Nuts, Check Nuts and washers of galvanized iron and thimbles and other end of the earth wire connected to main switch board and protected by galvanized iron pipe light grade 15 mm bore and water pipe 20 mm bore GI light grade with funnel and wire mesh PCC chamber in cement concrete 1:3:6 type C-2 & RCC cover all as specified & shown in elect plate No. 3 of SSR part I of 2010 including testing on completion including taking down existing unserviceable earthing complete all as specified. (Note:-Earth strip and protection pipe upto board is included in the rate quoted)
S&F in replacement for LED building street light fitting 35 watts, made in pressure diecast housing with eppoxy power coated dark graphite grey colour finish, parismatic polycarbonate cover with individual LED lense with IP 65 complete with all accessories and necessary fixing arrangement on wall at any height including three core 0.5 sqmm copper cable from connector to fitting, bracket made up of 40mm bore light grade GI pipe 1.2 m long including necessary bending welding etc complete all as specified and directed
M&L for sub main wiring complete with 2 run of 4 sqmm, single core, copper conductor cable 1100 volts grade, FRLS type, PVC insulated, unsheathed, flexible, multi stranded duly colour coded cable drawn through and including PVC conduit of size 25mm width or above as required at site and accessories such as tee, corners,overlaping connector etc of suitable size fixed on surface of walls/roofs/ceiling and including 01 run of 4 sqmm single core, copper conductor cable 1100 volts grade, FRLS type, PVC insulated, unsheathed, flexible, multi stranded of green colour as earth continuity conductor connected to common earth dolly including removing old unserviceable sub main wiring items, complete all as specified and directed. (Note : - 02 run of 4 sqmm single core copper conductor cable and 01 run of 4 sqmm single core copper conductor and 01 run of PVC conduit shall be measured as one unit and also colour coding of wiring to be followed as red/yellow/blue for phase, black for neutral and green for earth).
Supply, laying, jointng and testing, XLPE insulated, armoured heavy duty electric cable with aluminium conductor 1100 volts grade of size 6 Sqmm 2 core laid in trenches, ducts, pipes, on poles and connection with necessary cables lugs, glands, including taking down old cable complete all as specified and directed. (Note :- Excavation of earth work, removing, returning filling in, sand cushoining, brick cable cover and protection GI pipe shall be measured and paid separetly and length of cable shall be one length unless otherwise as directed by GE).
S&F in replacement for MCB distribution board SPN 4 way, double door 240 volts duly painted with epoxy based powder coated painting suitable for mounting MCB SP/SPN as incomer and outgoings complete with busbar, neutral bar, earth bar connecting cable links with top and bottom removable gland plate with IP 42 protection fixed in wall including chases wall for fixing DB and making good distributed wall surface to match with existing specification complete all as specified and directed. (Note:- MCBs will be measured separately.)
Supply, install, commissioning and testing vertical storage water heater (geyser) 5 star rated as per BEE norms electricity operated suitable for 230 volts, 50 hz, AC supply system complete with porcelen/ glass coated insulated heating element, copper tank, external thermostat and docorative of capacity 25 Ltrs, including 01 No. CP connection for hot water and 01 No PVC connection for cold water including fixing on suitable bolts and nuts complete all as specified and directed.
M&L for sub main wiring complete with 2 run of 4 sqmm, single core, copper conductor cable 1100 volts grade, FRLS type, PVC insulated, unsheathed, flexible, multi stranded duly colour coded cable drawn through and including PVC conduit of size 25mm width or above as required at site and accessories such as tee, corners,overlaping connector etc of suitable size fixed on surface of walls/roofs/ceiling and including 01 run of 4 sqmm single core, copper conductor cable 1100 volts grade, FRLS type, PVC insulated, unsheathed, flexible, multi stranded of green colour as earth continuity conductor connected to common earth dolly complete all as specified and directed. (Note : - 02 run of 4 sqmm single core copper conductor cable and 01 run of 4 sqmm single core copper conductor and 01 run of PVC conduit shall be measured as one unit and also colour coding of wiring to be followed as red/yellow/blue for phase, black for neutral and green for earth).
S&F for sheet metal enclosure single pole and neutral with a two pin and earth plug and socket with one single pole MCB 20amp 230 volts complete all as specified and directed.
S&F for exhaust fan of 380mm sweep, heavy duty, 1200 RPM electrical operated 230 Volts AC single phase with PVC body with all accessories and louver etc including connecting up with three core flexible copper conductor cable of suitable size from ceiling rose to exhaust fan including necessary fixing aarangement for proper fixing in wall and connecting in existing point, complete all as specified and directed.
S&F for 15mm bore stop valve cast copper alloy screwed down, high pressure with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed, complete all as specified and directed.
S&F for 15mm bore bib tap cast copper alloy, with crutch or butterfly handle, screwed down for iron pipe or for brass ferrule complete all as specified and directed.
M&L for earthing complete with galvanized steel earth plate electrode 60cm x 60cm x 6 mm thick buried directly in ground vertically to a depth not less than 2.25 mtr below ground level with top edge of the earth plate at a depth not less than 1.5 mtr below ground level, earth plate surrounded by and packed with 15 cm thick layer of char coal dust and common salt, earth lead GI wire 4.00 mm dia by means of bolts, Nuts, Check Nuts and washers of galvanized iron and thimbles and other end of the earth wire connected to main switch board and protected by galvanized iron pipe light grade 15 mm bore and water pipe 20 mm bore GI light grade with funnel and wire mesh PCC chamber in cement concrete 1:3:6 type C-2 & RCC cover all as specified & shown in elect plate No. 3 of SSR part I of 2010 including testing on completion complete all as specified. (Note:-Earth strip and protection pipe upto board is included in the rate quoted)
Supply, laying, jointng and testing, XLPE insulated, armoured heavy duty electric cable with aluminium conductor 1100 volts grade of size 95 Sqmm 3.5 core laid in trenches, ducts, pipes, on poles and connection with necessary cables lugs, glands, including taking down old cable complete all as specified and directed. (Note :- Excavation of earth work, removing, returning filling in, sand cushoining, brick cable cover and protection GI pipe shall be measured and paid separetly and length of cable shall be one length unless otherwise as directed by GE).
Supply, installation, testing and commissioning of 100 KVA copper wound servo voltage controlled automatic voltage stabilizer incl foundation and plinth protection to keep stablizer at minimum 0.5 mtr above ground level and including following components and specifications :- (a) Input Voltage-300 to 480 (Phase-Phase) (b) output Voltage - 415 volt +/- 1.0 % (Phase-Phase) (c) Frequency - 50 HZ. (d) Capacity overload - 10 % over load for one hour.(e) Protection- overload and short circut through microprocessor of suitable rating based MCCB. (f) Outdoor type,(g)speed of correction 8 volts per second for single phase voltage and 15 volt per second for phase to phase voltage. (h) Response time not exceeding 20 mili second.(i) Sensitivity (+/-) 1 %. (j) Type of load : three phase unbalance type. (k) Digital display voltmeter/Ammeter (l) By pass arrangement in case of emergency. (m) Single phase sequence change protection.(n) Suitable capacity AC synchronous servo motor.(o) Suitable quantity of fresh transformer oil for adequate cooling.(p) Slector switch to check input and output voltage.(q) Auto/mannual switch to operate the stabilizer in auto/ manual mode. (r) Heavy duty aluminum bus bar for input and output connections. (s) Unidirectional roller wheels for easy portablity.(t) Cooling tube/ radiators for cooling of oil (u) Lifting lugs for lifting.(v) Oil level gauge. (w) First filling of new transformer oil as per IS-335, filtered and tested for die electric strength not less than 40 KV at 4.00 mm gap between testing electrode. Note :- i- Servo stablizer shall be copper wound comprising of above elements/parts with first filling of transformer oil as per IS upto appropriate level to be filled by the contractor and rates deemed to be included in the quoted rate of this item icluding. ii- Foundation as per OEM recommendation is deemed to be included is above quoted rate. iii- Disconnection of cable from existing transformer and all conection of stablizer are included in the quoted rate.
M/S Narinder Pal Choudhary
vijay kumar
M/S SURINDER PAL
RAJINDER CHOUDHARY
KANWAL KUMAR GUPTA
Ankit Sagar
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .