Executive Engineer (Works) Z P Kolhapur
Executive Engineer (Works) Z P Kolhapur
SPECIAL REAPIRS AND BEAUTIFICATION OF PHC TO MAKE PHC AT HUPARI TAL-HATKANANGALE DIST-KOLAHPUR
2026_KOLHA_1306871_2
E TENDER NOTICE NO 15/2026-27
Open Tender
Civil Works
180 days
KOLHAPUR
Please refer Tender documents.
2 documents required · 2 mandatory
₹12,000
₹61,403
9 Jun 2026
9 Jun 2026
24 Jun 2026
9 Jun 2026
23 Jun 2026
9 Jun 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount | Item Code |
|---|---|---|---|---|---|---|
| 1 | Removing cement tiles, or marble or polished shahabad floor or dado without bed concrete including stacking the materials as directed with all leads, lifts excetra complete.
Item / Page No : 19 / 297
Additional Specifications : The work shall be carried out as directed by Engineer-In-Charge. | 1 | Square Metre | - | - | BI01010001010000000000000515BI0100001112 |
| 2 | Removing doors and windows with frames and stacking the materials as directed with all leads, lifts excetra complete.
Item / Page No : 15 / 296
Additional Specifications : The work shall be carried out as directed by Engineer-In-Charge. | - | Number | - | - | BI01010001010000000000000515BI0100001113 |
| 3 | Excavation for foundation in earth, soil of all types, sand, gravel and soft murum, including removing the excavated material up to a distance of 50 metre beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting excetra complete. - (Lift upto 1.5 metre) By Mechanical Means
Item / Page No : 2 / 153
Specification No : Bd.A.1
Spec. Page No : 259
Additional Specifications : The useful excavated material shall be utilised as directed by the Engineer in-charge. | 1 | Cubic Metre | - | - | BI01010001010000000000000515BI0100001114 |
| 4 | Providing and laying Cast in situ/Ready Mix, cement concrete in M-10 of trap/ granite/ quartzite/ gneiss metal for foundation and bedding including bailling out water, formwork, laying/ pumping, compacting and curing, excetra complete, with fully automatic micro processor based Programmable Logic Controller without Supervisory Control and Data Aquisition enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) excetra complete. With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed, excetra) (using ARTIFICIAL SAND).
Item / Page No : 1 / 175
Specification No : Bd.E.1
Spec. Page No : 287-288
Additional Specifications : 1. The appropriate mix design shall be got done well in advance from the approved government laboratory and the same shall also be got approved from Engineer in-charge, before starting the work. 2. Cement from the same stock sent for mix design shall be used for concreting work. 3. The minimum cement for reinforced cement concrete / plain concrete to ensure durability / strength shall be as per IS 456-2000 with latest ammendment. If actual cement required / consumed is more than the provision in the IS code / approved mix design, no claim for that shall be entertained and cost for that shall be bourned by the contractor. 4. Before concreting work, cement from each consignment shall be got tested and if the strength of cement varies considerably from the approved mix design, the mix design should be got modified according to strength of fresh cement available in stock and concreting work should be done according to modified mix design. 5. For every consignment of cement, a sample shall be got tested as per norms and frequency of Vigilance and Quality Control Circle, Pune. As regards testing of cement it will be entire responsibility of the contractor. 6. If artificial / VSI crushed sand is used instead of natural sand; terms, conditions and specifications mentioned in Circular by Chief Engineer, Public Works Region, Pune bearing No CEP/D-2/Buildings-2/5940/2017 dated 17/10/2017 and Annexure-I attached to it and also Circular by Chief Engineer, Public Works Region, Nagpur bearing No 36 dated 15/01/2019 and Annexure-I attached to it will be appicable. | - | Cubic Metre | 1 | - | BI01010001010000000000000515BI0100001115 |
| 5 | Providing and laying Cast in situ / Ready Mix cement concrete M-20 of trap / granite /quartzite/ gneiss metal for bed blocks, foundation blocks and such other items including bailling out water, plywood / steel formwork, compacting, roughening them if special finish is to be provided, finishing uneven and honeycombed surface and curing, excetra complete. The cement mortar 1:3 plaster is considered for rendering uneven and honeycombed surface only. Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin, excetra (Wooden centering will not be allowed.)with fully automatic micro processor based Programmable Logic Controller without Supervisory Control and Data Aquisition enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) excetra complete. With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etc) (using ARTIFICIAL SAND).
Item / Page No : 10 / 176
Specification No : Bd.E.4, B-7
Spec. Page No : 289-290, 38-40
Additional Specifications : 1. The appropriate mix design shall be got done well in advance from the approved government laboratory and the same shall also be got approved from Engineer in-charge, before starting the work. 2. Cement from the same stock sent for mix design shall be used for concreting work. 3. The minimum cement for reinforced cement concrete / plain concrete to ensure durability / strength shall be as per IS 456-2000 with latest ammendment. If actual cement required / consumed is more than the provision in the IS code / approved mix design, no claim for that shall be entertained and cost for that shall be bourned by the contractor. 4. Before concreting work, cement from each consignment shall be got tested and if the strength of cement varies considerably from the approved mix design, the mix design should be got modified according to strength of fresh cement available in stock and concreting work should be done according to modified mix design. 5. For every consignment of cement, a sample shall be got tested as per norms and frequency of Vigilance and Quality Control Circle, Pune. As regards testing of cement it will be entire responsibility of the contractor. 6. If artificial / VSI crushed sand is used instead of natural sand; terms, conditions and specifications mentioned in Circular by Chief Engineer, Public Works Region, Pune bearing No CEP/D-2/Buildings-2/5940/2017 dated 17/10/2017 and Annexure-I attached to it and also Circular by Chief Engineer, Public Works Region, Nagpur bearing No 36 dated 15/01/2019 and Annexure-I attached to it will be appicable. | 1 | Cubic Metre | - | - | BI01010001010000000000000515BI0100001116 |
| 6 | Providing structural steel work in hollow section of various thickness and sizes in square, rectanular and round shape from 25 milimetre to 450 milimetre section as per Indian Standard : 4923 YST 310 grade produced from iron ore and blast furnace route, excetra as per detailed designs and drawing or as directed including cutting, fabricating, hoisting, erecting, fixing in position, making riveted / bolted / welded connections and painting complete. (For Ground Floor)
Item / Page No : 12 / 174
Additional Specifications : Work shall be carried out as per the instructions of Engineer In-Charge. | - | Metric Ton | 0.29 | - | BI01010001010000000000000515BI0100001117 |
| 7 | Providing and fixing of colour coated zincalume (R) AZ 150 (Minimum 150 grams per square metre total on each sides) profiled sheets for roofing. The feed material is manufactured out of nominal 0.45 milimetre base metal thickness (BMT) (0.5 milimetre TCT), Hi-strength steel with minium 550 MPa yield strength, metallic hot dip coated with Aluminium-Zinc alloy (55 percent aluminium, 43.4 percent zinc, 1.6 percent silicon) with COLORBOND (R) steel quality super durable polyster paint coat (with inorganic pigment). The paint shall have a total coating thickness of nominal 35 um, comprising of nominal 25 um exterior coat on top surface and nominal 10 um reverse coat on back surface. Profile sheet shall have nominal 950-1050 milimetre effective cover width and nominal 25-30 milimetre deep ribs with subtle square fluting in the five pan at nominal 180-250 milimetre center to centre. The end rib shall be designed for anti capilary groove and return leg. The feed material should have coil manufacturer's product details marked at regular interval. Including fasteners with minium fatened with minium 25 um zinc-tin alloy coated, hex head, self-drilling screw, excetra complete. (Weight of profile 4.52 kilogram per square metre). (For Ground Floor)
Item / Page No : 34 / 236
Additional Specifications : The work shall be done as per instructions of Engineer in charge. | - | Square Metre | - | - | BI01010001010000000000000515BI0100001118 |
| 8 | Providng and fixing in position anodised extruded aluminum partitions, partly glazed and partly laminated having frame made out of extruded tubular section of size 40 milimetre X 60 milimetre with 12 milimetre thick three layered flat pressed teak wood particle board bonded with boiling water proof type exterior grade phenol formaldehyde synthetic resin conforming to Indian Standard : 12823-1990, laminated on both sides, Novateak or equivalent and 5 milimetre thick selected quality plain / float glass panels fixed with aluminum glass clips 12 milimetre X 12 milimetre and rubber cushioning beading to glass partitions as per approved drawing, excetra compete. (For Ground Floor)
Item / Page No : 72 / 260
Additional Specifications : The work shall be done as per instructions of Engineer in charge. | 1 | Square Metre | - | - | BI01010001010000000000000515BI0100001119 |
| 9 | Providing and laying vitrified matt finish tiles of having size 590 milimetre to 605 milimetre X to 605 milimetre of 8 milimetre to 10 milimetre thickness and confirming to Indian Standard 15622-2006 (Group BIa) of approved make, shade and pattern for flooring in required position laid on a bed of 1:4 cement mortar including neat cement float, filling joints, curing and cleaning, excetra complete. (For Ground Floor) (using ARTIFICIAL SAND).
Item / Page No : 42 / 217
Specification No : Bd.M.12
Spec. Page No : 385
Additional Specifications : 1. The work shall be carried out as per instructions of Engineer in-charge. 2. The work shall be carried out as per the sample approved by the Engineer in-charge and kept in the office of the Executive Engineer. 3. Water absorption should not be more than 0.05 percent. 4. If artificial / VSI crushed sand is used instead of natural sand; terms, conditions and specifications mentioned in Circular by Chief Engineer, Public Works Region, Pune bearing No CEP/D-2/Buildings-2/5940/2017 dated 17/10/2017 and Annexure-I attached to it and also Circular by Chief Engineer, Public Works Region, Nagpur bearing No 36 dated 15/01/2019 and Annexure-I attached to it will be appicable. | - | Square Metre | - | - | BI01010001010000000000000515BI0100001120 |
| 10 | Providing and fixing machine cut machine polished 18 milimetre to 20 milimetre thick telephone black / amba white / cadbury brown / RBI red / ocean brown granite stone for treads and risers of steps and staircases of approved colour and shade with rounded moulding and three grooved line for the treads on a bed of 1:4 cement mortar including float, filling joints with neat cement slurry, curing, polishing and cleaning, excetra complete. (For Ground Floor) (using ARTIFICIAL SAND).
Item / Page No : 35 / 216
Specification No : Bd.M.22 B
Spec. Page No : 390
Additional Specifications : 1. The work shall be carried out as per instructions of Engineer in-charge. 2. The work shall be carried out as per the sample approved by the Engineer in-charge and kept in the office of the Executive Engineer. 3. The edge of step should be chafered or rounded as directed. 4. If artificial / VSI crushed sand is used instead of natural sand; terms, conditions and specifications mentioned in Circular by Chief Engineer, Public Works Region, Pune bearing No CEP/D-2/Buildings-2/5940/2017 dated 17/10/2017 and Annexure-I attached to it and also Circular by Chief Engineer, Public Works Region, Nagpur bearing No 36 dated 15/01/2019 and Annexure-I attached to it will be appicable. | 1 | Square Metre | - | - | BI01010001010000000000000515BI0100001121 |