Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹4.6 LAccepted-AOC HOUSE NO 95 STREET NO 08 JAWAHAR COLONY NEAR LAXMI DAIRY FARIDABAD SECTOR 22 HARYANA 121005 | FARIDABAD | HARYANA | 121005 | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹5.2 L+₹42,065 (8.88%)Rejected-AOC | L2 | Rejected-AOC other than lowest bidder |
Tender Value
₹6 L
EMD Value
₹12,000
Closing Date
16 Aug 2022, 6:00 pmClosed
AGE I CG
Noida
REPAIR MAINTENANCE OF APFC PANEL SERVO STABILIZER AND OTHER LT EQUIPMENTS AT SEC 62 52 24 and 23 UNDER AGE I COAST GUARD NOIDA
2022_MES_539293_1
AGE I CGN 18 22 23
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Noida
E b i
7 documents required · 7 mandatory
₹500
AGE I CG
₹12,000
14 Oct 2022
20 Jul 2022
18 Aug 2022
20 Jul 2022
16 Aug 2022
2 Aug 2022
Amount
Disconnecting Existing voltage stabilizer at Sec 23 and Sec-24 of 250 KVA capacity 3 phase 415 volts from electric mains , by unscrewing the nuts bolts etc repair/maintenence by draining out the transformer oil through the drain plug , dismantling both nut and bolt and lifting the top portion to carry out through inspection and clean the bottom portion of the voltage stabiliser tank by removing the mud and slurry and deposited material for prevention of short circuit and Refixing in Original position after Repair and testing complete all as specified and as directed by Engineer -in - charge. Note : Additional items/Spare parts required to make stabilizer serviceable, shall be measured and paid separately.
All as per Item No 01 above but capacity 400 KVA 3 phase 415 volts at sec 52
All as per Item No 01 above but capacity 750 KVA 3 phase 415 volts at sec 62
Supply & Fixing in replacement of Electronic sensing Control card (PCB). Suitable for Existing Make - Volina & Other ISI marked.
Supply & Fixing in replacement of PVC Connector 12 pin as per existing Make - Volina
Supply & Fixing in replacement of Dimmer varic state unit 150 Amps for 250 KVA stablizer suitable for Existing Make.
Supply only trigger (control) transformer with primary voltage 230 Volte and secondary voltage any desired voltage between 18 volt 500 mA suit the control circuit of the stabilizer as per sample.
Supply only trigger (control) transformer with primary voltage 230 Volte and secondary voltage any desired voltage between 24 volt 500 mA suit the control cercuit of the stabilizer as per sample.
Supply only panel push to on voltage adjuster switch all as specified and directed by Engr - In - Charge.
Supply only Auto Manual Switch all as specified and directed by Engr - In - Charge.
supply only in- put & out-put switches all as per sample
Supply only Micro switch (Limit switch) suitable to cut of supply to control motor on high and low settings limits all as specified and directed by Engr - In - Charge.
Supply only Gear assembly of 120 teeths suitable for synchronous motor to operate the shaft for variable dimmer stat all as specified and directed by Engr - In - Charge.
Supply only synchronous motor 10 Kg Torqe suitable to work with voltage stablizer of capacity 250 to 400 KVA.
Supply only Potentiometer suitable for servo voltage stablizer all as directed by Engr in charge.
Supply only carbon brush with holder as per sample suitable for stablizer of capacity 400 KVA all as directed by Engr in Charge.
Supply only carbon brush with holder as per sample suitable for stablizer of capacity 250 KVA all as directed by Engr in Charge.
S&F in replacement of RC Net work 3 Kg suitable for Existing servo stabilizer of capacity 250/400 KVA Make - Volina
S&F in repairs voltage Arms of cap 150/200 Ams for Existing servo stabilizer of capacity 250/400 KVA all as directed by Engr in charge.
S&F in replacement of Bus bar connections from varic to series transformer suitable for 250 KVA stabilizer.
S&F in replacement of copper Thimbles upto 185 Sqmm all as directed by Engr in charge.
Rewinding of variable Transformer of servo stabilizer up to 250 KVA Capacity 3 Ph all as directed by Engr in charge
Rewinding of series/ load Transformer up to 250 KVA Capacity 3 Ph all as directed by Engr in charge
Dehyderation,filteration of transformer oil of servo stabilizer using stream line filter to obtain a dielectric strength above 40 KV, including all arrangement for DG set,filteration plant,filter paper etc mentioned below all as directed and specified.
Supply and Filling the new transfermer oil of approved make conforming to IS- 335 including filtertion of existing and top up oil so as to achieve IR value of the oil not less than 40 KV as specifaied and all as directed by Engineer - in - charge.
M&L for Preparation of old painted surface of Servo Voltage stabiliser by scrapping / removing old paint , dirt etc, and spray painting with two coats of blue synthetic enamel paint over a coat of primer including writing of MES / SM No of capacity 250-400 KVA all as specified and directed by Engineer-in-charge.
Supply & Fixing in replacement of Digital Amp Meter with CTs suitable for Existing Make - Volina,AE ,L&T
S&F in replacement of MCCB thermal magnetic release, fixed type, 3 pole, 400 Amps, 415 Volts with repeturing capacity 36 KA and suitable for fixing in existing arrangement with connecting legs. Cat Part No- 422002 Make Legrand or its equivalent in L&T / Havells
S&F in replacement of MCCB, thermal magnetic electric release, fixed type, 3 pole, 250 Amps, 415 Volts with repeturing capacity 36 KA and suitable for fixing in existing arrangement with connecting legs. Cat Part No- 420529 Make Legrand or its equivalent in L&T / Havells
S&F in replacement of MCCB thermal magnetic electric release, fixed type, 3 pole, 200 Amps, 415 Volts with repeturing capacity 36 KA and suitable for fixing in existing arrangement with connecting legs. Cat Part No- 420238 Make Legrand or its equivalent in L&T / Havells
S&F in replacement of MCCB thermal magnetic electric release, fixed type, 3 pole, 125 Amps, 415 Volts with repeturing capacity 25 KA and suitable for fixing in existing arrangement with connecting legs. Cat Part No- 420046 Make Legrand or its equivalent in L&T / Havells
S&F in replacement of MCCB, thermal magnetic electric release, fixed type, 3 pole, 100 Amps, 415 Volts with repeturing capacity 16 KA and suitable for fixing in existing arrangement with connecting legs. Cat Part No- 420005 Make Legrand or its equivalent in L&T / Havells
S&F in replacement of MCCB, thermal magnetic electric release, fixed type, 3 pole, 63 Amps, 415 Volts with repeturing capacity 16 KA and suitable for fixing in existing arrangement with connecting legs. Cat Part No- 420005 Make Legrand or its equivalent in L&T / Havells
Supply and fixing (in replacement) of power contractor capacitor duty 3 pole 415 volts on panel mounted type including disconnecting the incoming/outgoing cable connections and re-connecting with suitable copper lugs/ferruls etc. after taking out the existing u/s and making good the disturbed surface for following capacity.
Contractor suitable for up to 1-2 KVAR
Contractor suitable for up to 3-5 KVAR
Contractor suitable for above 5 to 12.5 KVAR
Contractor suitable for above 12.5 KVAR to 20 KVAR
Contractor suitable for above 20 KVAR to 25 KVAR
Contractor suitable for above 33.3 KVAR to 50 KVAR
S&F in replacement of voltmeter 0-500 Volts digital type suitable for Existing Make - Volina,AE ,L&T
Supply and fix in replacement push button switch suitable for operating voltage 110/220 Volt for LT Panel
Supply and fix in replacement indicator lamp LED suitable for operating voltage 110/220 Volt for LT Panel
Dismantling APFC panel carefully,removing the defective control device MCCB/MCBs,capacitors,indicator cum push button switches,relays,contacts,CTs,internal wiring, Cleaning all parts by CTC solution / emary paper as required and greasing the metallic and mechanical serviceable parts.
Supply and fix relays NAAC 3P-12 suitable for 12 stage APFC panel Make:NEPTUNE or Equvallaent of EPCOS/L&T
Supply and fix relays NAAC 3P-8 suitable for 8 stage APFC panel Make:NEPTUNE or Equvallaent of EPCOS/L&T
Programming and tuning of relays suitable for APFC panel 8/12 stage all as directed by Engr-in-Charge
Supply and fix Heavy Duty Capacitors of capacity 1 -15 KVAR .Make L&T ,Epcos,Havells
Supply and fix Heavy Duty Capacitors of capacity 20 -50 KVAR box type .Make L&T ,Epcos,Havells
Supply and fix fresh air fan suitable for APFC panel
Supply and fix illuminated push button switch suitable for APFC Panel
Excavation in trenches not exceeding 1.5mtrs wide and not exceeding 1.5 mtr deep in hard /dense soil for laying underground cables and post holes all as specified and directed.
Returning filling in including spreading levelling watering and well ramming in layres not exceeding 25 cm thick in hard/ dense soil.
Removing surplus soil to a distance not exceeding 50 m and depositing at a level not exceeding 1.5m above the starting point.
Supply and spreed fine river sand in trenches for cable cushioning on top and bottom of cable as specified.for cable protection
Supply and laying sub class 'B' bricks size 230mmx115mmx75mm to be laid on sand cushioning for protection of cable.
PCC 1:4:8, type D-2, using 40 mm graded stone aggregate as in foundation, filling and mass concrete all as specified and as directed
PCC 1:3:6, type C-1, using 20 mm graded stone aggregate as in foundation/ coping of poles including necessary form work and finishing the exposed concrete surfaces even and fair all as specified and as directed
Removing from trench/duct etc old armouned, XLPE insulated LT electric power cables of any size and keeping in safe custody all as specified and directed
Fixing only MCCB any Capacity and any make only complete all as per site requirement or specified by Engr in Charge. ( Note item will be issued under Sch 'B' from department.)
Supply and fixing of XLPE insulated screened PVC bedded galvanised steel strip or wire armoured electric cable(heavy duty) with aluminium conductor 1100 volts grade cross sectional area 3½ core x 70 sq mm in trenches/on truss/wall/floor through pipe with MS clamps.
All as per item No 59 described here in before but of size 50 sq mm 3½ core
All as per item No 59 described here in before but of size 35 sq mm 3½ core
All as per item No 59 described here in before but of size 25 sq mm 3½ core
All as per item No 59 described here in before but of size16 sq mm 4 core
All as per item No 59 described here in before but of size 10 sq mm 4 core
All as per item No 59 described here in before but of size10 sq mm 2 core
Supplly and replacement of GI tubing medium grade 50 mm bore galvanized with all fitting laid in trenches/road crossing for UG cable protection all as directed/specified.
All as per item No 66 described here in before but 40 mm dia
Straight through joints (epoxy) suitable for 3.5 core PVC insulated and PVC sheathed armoured LT underground cable 50-70 Sq mm with aluminium conductors including joint kits and labour complete all specified and directed
All as per ser item No 68 but , 3.50 core cable 25-35 Sq mm
All as per ser item No 68 but , 3.50 core cable 10-16 Sq mm
Demolition of Concrete of any description and in any position not otherwise specifically provided for
M/L for preparation of old steel surfaces of LT Panel of any description, over 10cm in width or girth,not otherwise described and applying one coat of synthetic enamel paint complete all as specified and directed
S & F in replacement MS chequered plate of size 5/6 mm thick cut to required size as per the size of cable duct all as specified and directed
Removing the outdoor LT panel board and making the base of panel board with pcc and refixing the same panel on new pcc base with necessry fixing arrangement including disconnecting and reconnecting of LT cables and Earthings as directed by engineer-in-charge .(Earth work and PCC will be measured and paid seperately)
Supply and fixing in replacement of off load Change over switch in sheet metal enclosure 4 pole 415 volts side handle operation along with fixing arrangements with suitable nut, bolts, washers, including terminating the incoming/outgoing cables with suitable aluminum lugs/ferruls with proper crimping and testing comlete all as directed by Engr-in-Charge for 200 Amps
Supply and fixing in replacement of off load Change over switch in sheet metal enclosure 4 pole 415 volts side handle operation along with fixing arrangements with suitable nut, bolts, washers, including terminating the incoming/outgoing cables with suitable aluminum lugs/ferruls with proper crimping and testing comlete all as directed by Engr-in-Charge for 320 Amps
M/L for cutting the bituminous road in the size not exc 0.4 mtr X 0.6 mtr for laying of UG cables and making good with the existing surfaces with PCC after laying the pipe/cable all as directed
M&L in replacement steel tubular swaged poles swan neck complete with cast iron base plate,finial tapper plug, bolt,nuts & screws as specified type 410 SP-31 (9.0 metres long)
S & F in replacement cross arms, bracing, support, clamps etc made out of mild steel channel or angle section of reqd size and shape including clamp, back plate with bolts, nuts & washers drilled for insulator bolts, welding, bending cold or hot in any shape or size including all fixing arrangement on HT over head line and painted with two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified & as directed by Engr-in-Charge.
Material and labour for Painting of LT steel tubular pole with one coat of alluminum paint and black paint upto 1.2 meter from the bottom of the pole after preparing the existing surface of the poles and marking the poles numbers as per existing pattern including fixing three no flouresent tape 50 mm width of three colour around the pole at 1.2 meter height complete all as per specified and directed.
BLUE HILL ELECTRICAL AND ELECTRONICS
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .