| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹31.1 LAccepted-AOC | L1 | Accepted-AOC Accepted being lowest on 17 Sep 2021 | |
| 2 | L2₹31.7 L+₹58,609.46 (1.88%)Rejected-Finance H NO 273 VPO SURHERA WEST DELHI 110043 | WEST DELHI | DELHI | 110043 | L2 | Rejected-Finance Rejected | |
| 3 | L3₹33.1 L+₹2.0 L (6.31%)Rejected-Finance | L3 | Rejected-Finance Rejected |
Tender Value
₹35 L
EMD Value
₹70,000
Closing Date
25 Aug 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE Faridkot
Garrison Engineer, Faridkot-151203 Punjab 01639-264982
Provn of Certain Revenue and Minor Works under AGE B/R (M) at Faridkot Mil Stn
2021_MES_463089_1
GE FRD-39/2021-22
Open Tender
Civil Works
Item Rate
180 days
Faridkot Mil Stn
Class D Category a i
8 documents required · 8 mandatory
₹500
GE Faridkot
₹70,000
Yes
21 Sept 2021
27 Jul 2021
27 Aug 2021
27 Jul 2021
25 Aug 2021
10 Aug 2021
60 days
Amount
Demolition of Brickwork or stone/boulder masonry,built in cement mortar including all quoins, arches, pillars etc, but excluding ashlar facings, dressed stonework and precast concrete articles complete all as specified and directed
Cutting openings, through brick walls bulit in cement mortar for door, window and other openings or enlarging existing openings. converting window into door openings, etc. or cutting out defective brick work for under-pinning, including providing, fixing and removing shoring, cleaning and stacking bricks, removing surplus serviceable bricks, hard-core, etc. to store and rubbish not exc. 50m complete all as specified and directed
Demolition of concrete (reinforced) of any description and in any position not otherwise specifically provided for and removing debris and rubbish to distance not exc. 100m complete all as specified and directed.
Surface excavation not exceeding 30 cm deep and averaging 15 cm deep and getting out in any type of soil complete all as specified and directed
Excavation in trenches in any type of soil not exceeding 1.5m deep and 1.5m wide, for foundation etc or manholes,piers,shafts etc not exceeding 10 Sqm on plan and getting out complete all as specified and directed.
Excavation over areas n exc 1.5m deep and getting out in any type of soil complete all as specified and directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm complete all as specified and directed
Removing excavated material to a distance n exc. 50m and depositing where directed at a level n exc.1.5 m above the starting point complete all as specified and directed
M & L for cement concrete 1:3:6 type C-2 (using 40mm graded crushed stone aggregates) as in foundation, filling & mass concrete complete all as specified and directed .
M & L for cement concrete 1:4:8 type D-2 (using 40mm graded crushed stone aggregates) as in foundation, filling & mass concrete complete all as specified and directed .
M&L for Reinforced cement concrete M-25 (design mix) (using 20mm graded crushed stone aggregates) as in beams, cantilevers, bressummers, lintels over 1.5m , lintel bend complete all as specified and directed
M&L for Reinforced cement concrete M-25 (design mix) (using 20mm graded crushed stone aggregates) as in column, pillars, piers, posts and sturts complete all as specified and directed
M&L for Reinforced cement concrete M-25 (design mix) (using 20mm graded crushed stone aggregates) as in slab supported on walls, beams, columns,landings,balconies, canopies,deck slabs and in shelves and other similar works complete all as specified and directed
M&L for Reinforced cement concrete M-25 (design mix) (using 20mm graded crushed stone aggregates) as in foundation including rafts, footings, foundations beams; plinth beams, bases for column etc; basement slabls, under-reamed piles and mass concrete complete all as specified and directed
M&L for use and waste of formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits of foundation and plinth beam and similar work vertical or to batter complete all as specified and directed
M&L for use and waste of formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (horizontal or sloping) complete all as specified and directed
M&L for Mild steel TMT bars 10mm dia and over , cut to length, bent to shape as required, including cranking, bending and binding with & including mild steel wire (annealed) not less than 0.9mm dia complete all as specified and directed
M&L for Mild steel TMT bars 5 mm dia and over upto & including 10mm dia, as in stirrups, spacers and binders,cut to length bent to shape required including cranking, binding spirally for hooping for columns, hooking ends and binding with and including MS wire annealed not less than 0.9 mm dia or securining with clip complete all as specified and directed .
M&L for use and waste of form work to sides and soffits of floor or roof beam, beam, hauchings, girders, bressumemers, lintels, cantilevers, shelves incl supports overhangs etc also splays between floors and beams all as specified and directed.
M&L for brick work with fly ash bricks using old size bricks, straight or curved on plan exceeding 6m mean radius, built in cement mortar 1:6 complete all as specified and directed .
All as per item No 20 here-in-before above but except bricks
M&L for rendering 10 mm thick in cement mortar 1:4 on fair faces of brick work or concrete surfaces finished even and smooth without using extra cement complete all as specified and directed .
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and directed .
S&F Glazed ceramic coloured tiles 300mmx200mmx7mm thick (colour and shade as approved) as in vertical surfaces such as skirting/dados etc, set and jointed in neat cement slurry & pointed in white cement with pigment to match the colour of tiles over & including 15mm thick rendering in cement mortar 1:4 complete all as specified and directed
S&F Machine cut kota stone slab in flooring 20-25mm thick laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing,cutting and mirror polishing over and including 15 mm thick screed bed or bedding layer in cement mortar 1:4 complete all as specified and directed.
S&F Machine cut kota stone slab 20-25 mm thick as in skirting, set and jointed in cement slurry over screed and pointed in cement mixed with pigment to match the shade of slab including rubbing, cutting and mirror type polishing complete all as specified and directed .
S&F Non skid ceramic coloured tiles (light colour as approved) 7 to 8 mm thick (square/rectangular), area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm in floors etc, set and jointed in neat cement slurry and pointed in white cement with pigment to match the colour of tiles over & including 15mm thick screed in cement mortar 1:4 complete all as specified and directed.
S&F Steel rolling shutters having thickness of laths1.25mm gear operated type with bevel gear box and crank handle, as specified including top cover, anchoring rod, hasp and staple and one shop coat of primer; erected in position as indicated, complete: push pull or manual type complete all as specified and directed.
M&L preparation of new or previously untreated steel surface of any description, over 10cm width or girth, not otherwise described and applying two coats of synthetic enamel paint complete all as specified and directed. .
Excavating in post holes each not exc 0.50 cum, getting out in soft/loose soil, returning, filling in and ramming earth or broken rubble mixed with earth around, in layer not exc 25cm and removing surplus soil to a distance not exc 50m and making good surface all as specified`and directed .
M&L for PCC 1:2:4 type B1 (using 20mm graded crushed stone aggregates) as in back filling of kerb stones,mass filling complete all as specified and directed
S&F structural steel work in tubular pole including special shaped washer etc complete using ERW or incuction butt welded tubes conforming to I.S. 1161-1998 grade St -240 complete all as specified and directed .
S&F Rolled sections as in main and cross beams, hip and jack rafters, purlins where connected to common rafters and running rails fixed with angle cleats or other connecting plates conforming to Fe-410-W(Gde-E-250, quality-A) complete all as specified and directed
M&L for rolled steel section as in posts ,any shape including bending and welding angles as necessary,gusset plates,rivetting etc and similar work conforming to Fe-290 Gde E-165 complete all as specified and directed
M&L for preparation of new or previously untreated steel surface of any description over 10cm width or girth, not otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed.
S&F Pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed
M&L for hard core of gauge not exceeding 63mm using broken stone or boulders, deposited, spread and leveled in layers not exc 15cm thick, watered and rolled/rammed to a true surfaces complete all as specified and directed .
M&L Sand filling under floors etc in layers n.exc 25 mm thick complete all as specified and directed.
M&L machine pressed, precast concrete interlocking coloured paver block, any shape and size confirming to IS-15658-2006 of 80mm thickness, M-40 Grade with grey cement and pigment complete all as specified and directed.
M&L machine pressed, precast concrete interlocking coloured paver block, any shape and size confirming to IS-15658-2006 of 60mm thickness, M-35 Grade with grey cement and pigment complete all as specified and directed.
S&F factory made precast kerb stones in PCC 1:2 :4 type B-1 including chamfers, weatherings,throatings etc in smooth finish & set in cement mortar 1:4 including necessary excavtion and earth work for embedding kerb stone at a depth as directed and temping around kerb stone and removal of surplus soil to a distance not exceeding 50 m and depositing where directed complete all as specified and directed .
M&L preparation of new or previously untreated concrete surfaces over 10cm width or girth ,not otherwise described and applying two coat of synthetic enamel paint over a coat of primer complete all as specified and directed
M&L for PCC 1:1.5:3, type A1 (using 20mm graded crushed stone aggregates) as in floor etc finished even and smooth complete all as specified and directed.
M&L for preparation of newly plastered or unplastered surfaces of wall and applying two coat of cement base paint complete all as specified and directed .
M&L for forming contraction(Dummy) joints 25mm deep x 10mm wide, filled with sealing compound of Grade 'B' complete all as specified and directed .
S&F GI tubing,15mm bore, medium grade with all fittings , fixed to wall/ceiling and laid in floors complete all as specified and directed .
S&F GI tubing,20mm bore, medium grade with all fittings , fixed to wall/ceiling and laid in floors complete all as specified and directed .
S&F bib tap chromium plated brass with crutch or butter fly handle, screwed down, screwed for 15mm bore pipe & fixed complete all as specified and directed .
S&F Pillar tap, cast copper alloy, capastan head,chromium plated,screwed down for high pressure with crutch or butter fly handle, screwed both ends for iron pipe of 15mm bore complete all as specified and directed
S&F Stop/angle valve, fancy type,chromium plated ,cast copper alloy, screwed down for high pressure with crutch or butter fly handle, screwed both ends for iron pipe of 15mm bore complete all as specified and directed
S&F Vitreous china squatting pan, 'Orissa' pattern, size 580x440 mm white, with integral foot rests, CI 'P' or 'S' traps 100mm & PVC flush pipes 32mm dia including connecting to trap and to flushing pipe, anti-syphonage pipe etc including all joints and making good to floor complete all as specified and directed.
S&F vitreous china wash hand basin, white, flat back of size 550mm x 400mm including CI brackets, CP brass waste coupling with rubber washer and waste pipe 32mm bore complete all as specified and directed
S&F 15mm Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and directed .
S&F Stop valve, cast copper alloy, screwed down for high pressure with crutch or butter fly handle, screwed both ends for iron pipe of 20mm bore complete all as specified and directed
S&F rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) 2000 Ltr capacity.triple layered, hoisted and fixed in position including ball brass valves, high pressure, with polythene float and fly nut screwed for 20mm bore iron pipe complete all as specified and directed .
S&F rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) 1000 Ltr capacity.triple layered, hoisted and fixed in position including ball brass valves, high pressure, with polythene float and fly nut screwed for 20mm bore iron pipe complete all as specified and directed .
M&L for PCC 1:3:6 type C2 (using 20mm graded crushed stone aggregate) as in coping including necessary formwork, weathering, slightly rounded or chamfered angles complete all as specified and directed ..
Extra for forming fair finishing drain or channel 150mm inner girth in cement concrete, using extra cement including forms, moulds, mitred/stopped ends etc complete all as specified and directed .
M&L for Concrete bed to drain pipes using PCC 1:4:8 type D-2 (using 40mm graded crushed stone aggregates) including packing under and haunching against the sides of pipes after they are laid & tested for 150mm bore of pipes complete all as specified and direced.
S&F Reinforced concrete pipes of 150mm bore , class NP-2 laid and jointed with collar complete all as specified and directed.
M&L for 25mm thick plain cement concrete 1:2:4 type B-0 (using 12.5mm graded crushed stone aggregates) as in flooring complete all as specified and directed
M&L for 75 mm thick cement concrete 1:3:6 type C2( using 40mm graded crushed aggregates) as in plinth protection finishing surfaces even and fair complete all as specified and directed .
M&L PVC (SWR) floor trap, 75 mm dia, plain with stainless steel grating including jointing with solvent cement complete all as specified and directed
M&L for brick work with old size sub-class 'B' bricks, straight or curved on plan to any radius in half brick thick walls, built in cement mortar 1:4 complete all as specified and directed .
Cutting into existing manholes for connecting new drains, making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2) round or 3/4 section) in cement concrete 1:2:4 type B-1 smooth finished, and reforming benching as required (Internal Dia of pipe in 150mm) complete all as specified and directed.
M&L for PCC 1:2:4 type B-1 (using 20mm graded crushed stone aggregates) as in manholes cover set in cement mortar 1:4 complete all as specified and directed.
M&L for preparation of new plastered or unplastered surfaces of walls and applying three coat of white wash complete all as specified and directed
M&L Rendering 15 mm thick in cement mortar 1:6 on stone masonry surfaces or surface other than fair face of brickwork or on one side of lathing, finished even and smooth without using extra cement complete all as specified and directed
S&F 75mm bore PVC (SWR) pipes, single socketed in any length with rubber ring joints, laid in trenches/in floors/fixed to walls including fixing clamps with nut and bolts complete all as specified and directed .
S&F 75mm bore, PVC(SWR) branch pieces, double Y (equal or unequal) complete all as specified and directed
S&F Solid wood moulded grain printed PVC door frame of size 50mm x 95 mm made out of 5mm wood grain printed PVC sheet reinforced with M.S. square tube, egdes will be painted to match printed sheets complete all as specified and directed .
S&F Factory Made Solid PVC Moulded Door Shutter, with particle board core, 28 to 30mm thick (stiles), with 2, 4, or 6 raised panel design with 2mm thick Woodgrain moulded PVC Sheet on the front face & 2mm plain colour PVC sheet on back face, supplying & fixing in frame at site as per specification & drawing all as specified and directed
S&F galvanised mild steel wire cloth 0.56 mm nominal dia of wire and average width of aperture 1.18 mm and fixed with tinned tacks or galvanised wire staples complete all as specified and directed .
S&F Glazed ceramic coloured tiles 450mmx300mmx7mm thick (colour and shade as approved) as in vertical surfaces such as skirting/dados etc, set and jointed in neat cement slurry & pointed in white cement with pigment to match the colour of tiles over & including 15mm thick rendering in cement mortar 1:4 complete all as specified and directed
S&F Grating doom 100 mm dia of PTMT (minimum weight 25gms) complete all as specified and directed
S&F PVC (SWR) bend any radius 110 mm bore complete all as specified and directed
S&F PVC (SWR) bend any radius 75 mm bore complete all as specified and directed
S&F PVC (SWR) vent cowl 75 mm bore complete all as specified and directed
S&F Shelf of PTMT, fixed with and including chromium plated brass screws and wooden/plastic cleats (Minimum weight 300gms) complete all as specified and directed.
S&F Steel windows with side hung shutters including projecting type hinges with steel handle, and steel peg stay, complete with glazing bars, dovetailed or welded all as specified and directed
S&F Steel windows with side hung shutters including projecting type hinges with steel handle, and steel peg stay, complete without glazing bars, dovetailed or welded all as specified and directed .
S&F Steel windows or ventilators, fixed type, with glazing bars complete all as specified and directed.
M&L for 3 mm thick, plain sheet glass, ordinary quality and glazing with oil putty or with wooden beads in squares n.exc 0.5 sqm each pane complete all as specified and directed .
S&F 3mm thick, figured glass, pin head type and glazing with oil putty in squares n exc 0.5 sq. m in each pane complete all as specified and directed .
S&F Pressed steel frames of size 105 x 60mm for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc.complete all as specified and directed.
M&L for PCC 1:3:6, type C0 (using 12.5mm graded crushed stone aggregates) as in back filling of pressed steel frames, bed blocks, fixing of hold fasts etc including necessary formwork complete all as specified and directed
S&F 35 mm thick 2nd class hard wood, plain, framed, panelled shutters (any number of panels) with panels of timber flat on both sides (feather edges) or of vaneered partical board medium desnsity, wood partical board with commercial face veneers fitted to chowkats complete all as specified and directed
S&F aluminium anodised barrel tower bolts,150 mm long of extruded section, fixed to doors with screws complete all as specified and directed .
S&F aluminium anodised barrel tower bolts,200 mm long of extruded section, fixed to doors with screws complete all as specified and directed .
S&F Aluminium anodised, cast type, handle 150 mm size complete all as specified and directed.
S&F aluminium alloy, anodised, sliding door bolt of length 250mm with hasp and staple (bolt type) and fixing clips of sheet, cast or extruded section and fixing bolt and sliding bolts of extuded sections or cast aluminium alloy and fixed complete all as specified and directed .
S&F 140 mm floor door stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring, fixed in floor complete all as specified and directed .
Framed work such as grills, gratings etc. with ends of bars shoulderd and/or riveted, or forged into spikes, framed guard bars, barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe290, Gde-E-165 complete all as specified and directed.
M&L for rendering 10 mm thick in cement mortar 1:3 on ceiling, finished even and smooth without using extra cement complete all as specified and directed .
M&L for preparation of new plastered or unplastered surfaces of ceiling and applying two coat of white wash complete all as specified and directed
M&L for preparation of new or previously untreated surface of wood or wooden based surfce any description not other wise described over 10 cm width or girth and applying two coat of synthetic enamel paint over a coat of pink primer complete all as specified and directed.
S&F Towel rail, 450mm long of PTMT, fixed with and including chromium plated brass screws and wooden and plastic cleats ( minimum weight 170gms ) complete all as specified & directed
S& F PVC connections 15 mm size, 450 mm long with PTMT nuts complete all as specified & directed
S&F 10 litres PVC,valveless, syphonic action type, flushing cistern, low level, white, with inlet, ball valve, float and handle including brackets complete all as specified and directed.
S&F 100mm mild steel butt hinges, medium weight,cold rolled complete all as specified and directed.
S&F 110mm bore PVC (SWR) pipes, single socketed in any length with rubber ring joints, laid in trenches/in floors/fixed to walls including fixing clamps with nut and bolts complete all as specified and directed .
S&F 110mm bore, PVC(SWR) branch pieces, double Y (equal or unequal) complete all as specified and directed
M&L for 100mm thick plain cement concerete 1:4:8, type D-2 (using 40 mm graded crushed stone aggregates) complete all as specified and directed
M&L for use and waste of form work to sides of columns square/rectangular,pillar,post etc for fair finished surfaces complete all as specified and directed.
M&L for Rendering 10 mm thick in cement mortar 1:4 with WPC on roof, fair faces of brick work or concrete surfaces all as specified and directed . Note : WPC will be measured and paid separately
M&L 40mm thick brick tiles laid on lime concrete and joints grouted flush in cement mortar 1:3 mixed with 5% of crude oil by weight of cement on mud phuska complete all as specified and directed .
M&L for polythene film, black, 500 micron thick, laid in floors complete all as specified and directed
M&L for 75 mm thick PCC 1:4:8, type D-2 (using 40 mm graded crushed stone aggregates), as in flooring, sub base complete all as specified and directed
M&L for applying evenly a tack coat of in industrial bitumen 85/25 at the rate of 1.2 kg per sq.m including cleaning surfaces complete all as specified and directed .
M&L for polythene film, 300 micron thick, laid on a coat of bitumen primer, @ 0.30 to 0.50 kg per sqm conforming to IS specification with lap joints 100mm wide complete all as specified and directed
M&L for lime concrete 1:2:5 (Lime:surkhi:brick ballast(40mm)) terracing in roof complete all as specified and directed .
Supply only Liquid water proofing compound
Taking down MCCB, MCB, DB TPN/SPN and making good the disturbed walls and surface area etc complete all as specified and directed .
Taking down carefully existing aluminium/copper point wiring for light, fan, socket or power bell complete with fittings such as Switches, sockets, ceiling roses, holders, call bells & making good the disturbed surfaces of walls, matching the colour with existing surface complete all as specified and directed. Note : Rate for making good shall be deemed to be included in above item rate.
Taking down unserviceable submain wiring, any size, any run with earthing cable and making good the disturbed area complete all as specified and directed.
Point wiring complete with 1.5 sqmm single core PVC insulated unsheathed cable(ISI marked) 1100 volts grade FRLS with multistranded copper conductor, drawn through concealed / surface in wall / roof/ceiling surface and its accessories on the surface etc including PVC rigid concealed conduit of suitable size with all accessories such as bend, reducers, MS hooks, MS junction boxes, 2mm thick galvanised steel pressed sunken terminal boxes of suitable sizes for mounting of switches, sockets, fan regulator etc, covered with 2.8mm thick plastic laminate Hylem / Anchor top cover sheet of required colour, fixed with brass screws and cup washers, painting terminal boxes inside and outside with one coat of red oxide primer including continuous earth wire of size 1.5 Sqmm PVC stranded copper conductor unsheathed, insulated, stranded (Green colour) connected to common earth point dolly for One light point/ fan point/ exhaust fan point and call bell point to be controlled by one number one way switch complete all as specified and directed .
All as per Srl item No. 117 here-in-before but for one three pin socket outlet 5 Amp on the same board with other switches complete all as specified and directed
All as per Srl item No. 117 here-in-before but for one switch socket combination, 3 Pin 5 Amps, 230 Volts on independent board complete all as specified and directed
All as per Srl item No. 117 here-in-before for switch socket combination (multi purpose) 6 Pin 15 Amps 230 volts point to be controlled by one switch and wiring with 2.5 Sqmm FRLS PVC unsheathed copper conductor and FRLS cable 2.5 Sqmm PVC insulated earth wire on independent board.complete all as specified and directed .
S&F PVC Lamp holder with back plate suitable for batten fittings complete all as specified and directed .
S&F LED bulb 1x10 watt having luminous efficiency warranty 2 years complete all as specified and directed .
S&F complete set of tube light fitting, 1x20 watt LED (4 feet long) 230 volt, decorative ultra slim linear LED lighting fixture with environment friendly, energy efficient ready to use pack etc with all acessories such as LED adopter, LED tube, internally prewired and including connecting up with twin core twisted flexible copper conductor cable of suitable size complete all as specified and directed
S&F complete set of tube light fitting, 1x10 watt LED (2 feet long) 230 volt, decorative ultra slim linear LED lighting fixture with environment friendly, energy efficient ready to use pack etc with all acessories such as LED adopter, LED tube, internally prewired and including connecting up with twin core twisted flexible copper conductor cable of suitable size complete all as specified and directed
S&F ceiling rose, three terminals, PVC polycarbonate, isolated body with bakalite 20mm back plate complete all as specified and directed .
S&F Sub main wiring with two runs of single core PVC FRLS sheathed, insulated, copper cable of 10 Sqmm size, multi stranded, 1100 volts grade with PVC insulated FRLS copper wire 10Sqmm for continous earth wire drawn into and including concealed conduit of suitable size complete all as specified and directed . Note :- Two runs of 10 Sqmm copper cable and one run of 10 sqmm copper wire earth continuty conductor in conduit with accessories shall be measured as one length)
S&F Sub main wiring with two runs of single core PVC FRLS sheathed, insulated, copper cable of 6 Sqmm size, multi stranded, 1100 volts grade with PVC insulated FRLS copper wire 6Sqmm for continous earth wire drawn into and including concealed conduit of suitable size complete all as specified and directed . Note :- Two runs of 6 Sqmm copper cable and one run of 6 sqmm copper wire earth continuty conductor in conduit with accessories shall be measured as one length)
S&F switch piano, flush type, single pole, one way, 5/6 Amps, 230 volts, AC supply complete all as specified & directed
S&F socket outlet, two-in-one, 5 pin, 5 Amp, 230 volts, AC supply complete all as specified & directed
S&F switch piano, flush type, single pole, one way, 15/16 Amps, 230 volts AC supply complete all as specified and directed
S&F socket outlet ,2 in 1, 5/6 pin, 15/16 Amps, 230 volts ,AC supply complete all as specified & directed
S&F Sheet metal enclosure for DBs,TPN, double door, 230 Volts,4 way complete all as specified and directed .
S&F Sheet metal enclosure for DBs,SPN, double door, 230 Volts,8 way with 200 amps rated bus bar complete all as specified and directed .
Supply, fixing & hanging Ceiling fan (white colour) energy efficient 1400mm sweep, including , AC single phase, 230V, including electronic type regulator, canopies, three Nos. blades, down rod, double ball bearing with capacitor 2.5 mfd and making connection with including PVC insulated PVC sheathed copper conductor flexible cable 3 core of suitable size from ceiling rose or connector to fan including marking of MES number, complete all as specified and directed .
S&F MCCB 3 Pole,415 V, adjustable type, 100 Amps with breaking capacity 16 KA complete all as specified and directed .
S&F MCB, SPN, 32 amps, 230V, C Series with breaking capacity 10 KA complete all as specified and directed
S&F MCB SP 5 to 32 Amp, 230 volts, C Series with breaking capacity 10 KA complete all as specified and directed
M&L for Earthing complete with galvanized steel earth plate electrode 60cmx60cmx6.00mm thick, buried directly in ground vertically (depth of pit not less than 2.25m below normal ground level), with top edge of the plate not less than 1.5m below normal ground level, earth plate surrounded by 15cm thick and packed alternate layers of charcoal dust and common salt, connected with and including earth lead of GI wire 4mm dia (8SWG) by means of bolts, nuts, check nuts and washers of galvanized iron or thimbles and other end of the earth wire connected to electrical equipment/GOD/LA and protected by galvanized iron pipe light grade 15mm dia bore including watering pipe 20mm dia bore GI medium grade (ISI marked) with funnel and wire mesh, including all necessary excavation and earth work, PCC chamber in plain cement concrete (1:3:6) type C-1 and pit cover of precast RCC with MS frame etc and all as shown in electrical plate No 3 of MES Schedule Part-I (2009), complete all as specified and directed. Note(s):- (i) RCC pit cover shall be pre-cast of RCC (1:2:4) type B-1, 80mm thick reinforced with XPM not less than 4Kg/Sqm. (ii) PCC chamber shall be constructed 1000 mm away from the edge of earth pit. (iii) Rate shall include earth lead and protection pipe of length 7.5m, excess beyond 7.5m length required at site shall be measured and paid separately. (iv) Earth resistance should be less than 3Ohm. In case the test results are not found below 3Ohm, complete earthing will be redone without any extra cost to Govt. (v) Quoted lump sum / rate shall be inclusive of above all provisions.
M&L for sand cushioning with a layer of dry river sand, 80mm thick before laying of cable and 150mm thick (punned down to 100mm thick) after laying of cables, in trenches/ducts, complete all as specified and directed. Note : Punned down thickness (overall 18cm), shall be considered for measurement and payment.
M&L for brick protection with old size sub class 'B' bricks, laid flat , length of bricks across the route of underground cable complete all as specified and directed .
Supply, laying, jointing, testing and commissioning of Low Tension (LT) XLPE insulated, armoured, heavy duty, electric power cable, cross sectional area 16 Sqmm, 4 core, aluminum conductor, 1100 volts grade under ground cable including both side connection with lugs/thimbles of suitable size etc, laid in trenches, along poles or passing through pipes or laid under floor or through walls etc, complete including taking out old cable & bricks all as specified and as directed. Note: (i) Returning filling, earth work, sand cushioning and brick cover for protection of cable shall be measured and paid separately.
Supply, laying, jointing, testing and commissioning of Low Tension (LT) XLPE insulated, armoured, heavy duty, electric power cable, cross sectional area 16 Sqmm, 2 core, aluminum conductor, 1100 volts grade under ground cable including both side connection with lugs/thimbles of suitable size etc, laid in trenches, along poles or passing through pipes or laid under floor or through walls etc, complete including taking out old cable & bricks all as specified and as directed. Note: (i) Returning filling, earth work, sand cushioning and brick cover for protection of cable shall be measured and paid separately.
Supply, laying, jointing, testing and commissioning of Low Tension (LT) XLPE insulated, armoured, heavy duty, electric power cable, cross sectional area 10 Sqmm, 4 core, aluminum conductor, 1100 volts grade under ground cable including both side connection with lugs/thimbles of suitable size etc, laid in trenches, along poles or passing through pipes or laid under floor or through walls etc, complete including taking out old cable & bricks all as specified and as directed. Note: (i) Returning filling, earth work, sand cushioning and brick cover for protection of cable shall be measured and paid separately.
Supply, fixing and testing LED street, Security light fitting of 25 Watt fitted on 4 to 9 meter high octagonal pole / wall/Swan neck pole including LED lamps complete with body robust, corrosion resistant, superior finish and without any cracks or through holes, made in a single piece by high pressure die cast aluminium alloy. The luminaries shall be monolithic construction, totally enclosed, dust and water proof with minimum IP-65 protection as per IS-10322-1982 (Part-I) with latest amendments and input voltage range 140-300V, AC, frequency 50-60 Hz, PF should be more than 0.9 with total harmonic distoration. THD (I) less than 15%, cool white colour and lamp starting time should not be more than 10 second, Fittings should be provided with 10 KV surge protection. Driver should be constant current constant voltage driver. Driver should have high voltage withstanding capacity upto 300V, AC. Driver should also have double phase protection, no load, open circuit and short circuit protection. LED light fittings should be suitable for ambient temperature from - 10 degree centrigrade to 50 degree centigrade and humidity level 10% to 90% RH. Covers should be polycarbonate/ toughened glass to ensure minimum IP 65 degree protection. Cover should not degrade due to heating and ageing. The efficient of LED luminaries system shall be more than 85 lumens per watt and must be certified by LM-79 test report fixed on and including bracket of 40mm dia,light grade ,GI pipe ,1.20 m and connecting with twin core twisted flexible copper conductor cable 1.5 Sqmm complete all as specified and directed . Note :- (a) Bidder shall submit test report of LED street light fitting from accredited test laboratory for LM-79 (b)Bidder has to furnish a replacement warranty of 05 years for LED light fittings complete including lamps from the date of completion of CA. The product will be replaced free of cost in the following cases : - (i) Manufacturing defects (ii) Failure due to mechanical and electrical impact, (iii) Drop in lumen (or lux at 1m) below 90% of claimed values of lumen (or lux at 1m) of the LED/ luminairies. (c) All LED light luminaire must meet the provision laid down in IS-16101, 16102 Part-I/II, 16103 Part-I, 16104, 16105, 16106, 16108/2012 and 15885 Part-II/ Section 13 (d) Scope of work shall include supply and fixing street light fittings on poles which includes required T & P and accessories etc if any, making connection, testing etc complete. No extra payment is admissible on these account.
S&F GI tubing,25mm bore, medium grade with all fittings , fixed to wall/ceiling and laid in floors complete all as specified and directed
S & F gun metal globe or gate valve with iron wheel head, screwed both ends for iron pipe & fixed for 25 mm dia of pipe complete all as specified and directed.
Supply and laying / fixing , GI pipe, light grade, 40mm bore, for cable protection, fixed to pole/wall with MS clamps, nuts, bolts etc or laid under floor/road/pavement, complete all as specified and directed. Note : (i) Excavation and earth work shall be measured and paid separately.
S&F 1X10 watt LED retrofit type bulk head fitting luminaries, die cast, aluminium alloy body, heat resistant, prismatic glass cover with specially designed gasket, lamp holder etc complete with all accessories and including connecting up with twin core twisted flexible copper coductor cable with suitable size of 230 volt,50 HZ complete all as specified and directed.
Supply, fixing and testing LED flood light fitting of 160Watt fitted on high mast light including LED lamps complete with body robust, corrosion, resistant, superior finish and without any cracks or through holes, made in a single piece by high pressure die cast aluminium alloy. The luminaries shall be monolithic construction totally enclosed dust and water proof with minimum IP-66 protection as per IS-10322-1982 (Part-I) with latest amendments and input voltage range 140-300V, AC, frequency 50-60 Hz, PF should be more than 0.9 with total harmonic distoration THD (I) less than 15%, cool white colour and lamp starting time should not be more than 10 second, Fittings should be provided with 10 KV surge protection. Driver should be constant current constant voltage driver. Driver should have high voltage withstanding capacity upto 300V, AC. Driver should also have double phase protection, no load, open circuit and short circuit protection. LED flood light fittings should be suitable for ambient temperature from - 10 degree centrigrade to 50 degree centigrade and humidity level 10% to 90% RH. Covers should be polycarbonate/ toughened glass to ensure minimum IP 65 degree protection. Cover should not degrade due to heating and ageing. The efficieny of LED luminaries system shall be more than 85 lumens per watt and must be certified by LM-79 test report complete all as specified and directed. Make: Crompton/ Bajaj/Havells/Halonix/Philips Note: (a) Bidder shall submit test report of LED street light fitting from Govt approved accredited test laboratory for LM-79. (b) Bidder has to furnish a replacement warranty of 05 years for LED light fittings complete including lamps from the date of completion of CA. The product will be replaced free of cost in the following cases : - (i) Manufacturing defects, (ii) Failure due to mechanical and electrical impact, (iii) Drop in lumen (or lux at 1m) below 90% of claimed values of lumen (or lux at 1m) of the LED/ luminairies. (c) All LED light luminaire must meet the provision laid down in IS-16101, 16102 Part-I/II, 16103 Part-I, 16104, 16105, 16106, 16108/2012 and 15885 Part-II/ Section 13 (d) scope of work shall include needful T & P and required accessories etc as per manufacturers recommendation complete including making connection, testing etc complete. Note: Every light fitting will be warranty 5 years after completion of CA and replacement/defects as applicable should be complied/rectified within 7 days .
S&F Sheet metal enclosure for DBs,floor mounted suitable to accommodate with and including MCB 32 Amps,DP & MCB 10 Amps-02 Nos complete all as specified and directed
Material & labour, for cutting existing road for taking out/laying of underground cable through GI pipe of dia 40mm including necessary earth work and making good to match with the existing surface with PCC 1:2:4 type B-1 using 20mm graded stone aggregates complete all as specified and directed
S&F sheet metal enclosure wih socket plug top and MCBs 20 Amp, 240 V, AC Supply, Single Pole and neutral enclosure with a two pin and earth plug with socket complete all as specified and directed .
Supply & fixing in replacement PVC insulated, multi stranded aluminium conductor, PVC sheathed cable, 4 sqmm 2 core and making connection of street light fittings with overhead lines/ UG cable complete all as specified and directed .
S&F Exhaust fan, 300mm sweep, steel body, 1400 RPM trans air 70 Watt, with four blades,louvers, suitable for operation on 220/230 volts, single phase , AC, all fixing arrangements like wall hole etc and complete all as specified and directed . Note : A sum of Rs. 5,259.00 will be deducted on account of credit for dismantled/ demolished / taken down material. Please refer details on Srl Page No. 29 (Schedule of Credit) of Tender document
M/S RAJESH KUMAR and CO.
M/S BSS AND SONS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .