| 1 | L1₹34.5 LAccepted-AOC | ₹34.5 L | L1 | Accepted-AOC L1 |
| 2 | Rejected-Technical VILL KULAPATHAR P S DHEMAJI P O ARADHAL DIST DHEMAJI ASSAM | DHEMAJI | ASSAM | 787026 | - | - | Rejected-Technical Technically NOT Responsive |
| Sl No | Description | Qty | Unit | PRABHAT DEORI L1 |
|---|---|---|---|---|
| 1.00 | 2.8 Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.
2.8.1 All kinds of soil. | 40.81 | cum | 306.93 ₹12,525.81 |
| 2.00 | 4.1.8 1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived fromnatural sources) | 2.13 | cum | 6,768.87 ₹14,417.69 |
| 3.00 | 16.12 Dry brick pitching half brick thick in drains including supply of bricks and preparing the surface complete :
16.12.1 With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 | 201.36 | sqm | 649.7 ₹1.3 L |
| 4.00 | 5.1 Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level :
5.1.3 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size de rived from natural sources) | 17.83 | cum | 8,501.85 ₹1.5 L |
| 5.00 | 5.2 Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement :
5.2.2 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) | 6.92 | cum | 10,898 ₹75,414.16 |
| 6.00 | 5.3 Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement: 1.5 coarse sand (zone-III) derived from natural sources: 3 graded stone aggregate 20mm nominal size derived from natural sources). | 5.16 | cum | 11,469.65 ₹59,183.39 |
| 7.00 | 6.2 Brick work with common burnt clay modular bricks of class designation 7.5 in foundation and plinth in:
6.2.2 Cement Mortar 1:6 (1 cement: 6 coarse sand). | 8.73 | cum | 5,938.45 ₹51,842.67 |
| 8.00 | 6.13 Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level.
6.13.2 Cement mortar 1:4 (1 cement :4 coarse sand) | 130.79 | sqm | 1,089.31 ₹1.4 L |
| 9.00 | 5.22 Steel reinforcement for R.C.C. work including straightening, cutting,bending, placing in position and binding all complete up to plinth level.
5.22.6 Thermo-Mechanically Treated bars of grade Fe-500D or more. | 267.17 | kg | 95.93 ₹25,629.62 |
| 10.00 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level.
5.22A.6 Thermo-Mechanically Treated bars of grade Fe-500D or more. | 1,121.28 | kg | 95.93 ₹1.1 L |
Tender Value
₹32.3 L
EMD Value
₹64,660
Closing Date
22 Dec 2025, 12:00 pmClosed
EE, PWD, Dibrugarh Bldg Division
EE, PWD, Dibrugarh Bldg Division
Construction of Electrical Laboratory (E-Lab) at Barboruah I.T.I., Dibrugarh, Assam
2025_PWBNH_49350_1
Tech/ITI/BARBARUAH/199/3294A
Open Tender
Civil Works - Building
180 days
Barbaruah
Please refer tender Documents
5 documents required · 5 mandatory
₹700
Yes
₹64,660
Yes
EE PWD Bldg office, Fulbagan
11 Feb 2026
16 Dec 2025
22 Dec 2025
16 Dec 2025
22 Dec 2025
16 Dec 2025
18 Dec 2025
Amount
2.8 Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. 2.8.1 All kinds of soil.
4.1.8 1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived fromnatural sources)
16.12 Dry brick pitching half brick thick in drains including supply of bricks and preparing the surface complete : 16.12.1 With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
5.1 Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : 5.1.3 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size de rived from natural sources)
5.2 Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : 5.2.2 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources)
5.3 Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement: 1.5 coarse sand (zone-III) derived from natural sources: 3 graded stone aggregate 20mm nominal size derived from natural sources).
6.2 Brick work with common burnt clay modular bricks of class designation 7.5 in foundation and plinth in: 6.2.2 Cement Mortar 1:6 (1 cement: 6 coarse sand).
6.13 Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level. 6.13.2 Cement mortar 1:4 (1 cement :4 coarse sand)
5.22 Steel reinforcement for R.C.C. work including straightening, cutting,bending, placing in position and binding all complete up to plinth level. 5.22.6 Thermo-Mechanically Treated bars of grade Fe-500D or more.
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level. 5.22A.6 Thermo-Mechanically Treated bars of grade Fe-500D or more.
5.9 Centering and shuttering including strutting, propping etc. and removal of form for 5.9.1 Foundations, footings, bases of columns, etc. for mass concrete
5.9.5 Lintels, beams, plinth beams, girders, bressumers and cantilevers
5.9.6 Columns, Pillars, Piers, Abutments, Posts and Struts
4.10 Providing and laying damp-proof course 40mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 12.5mm nominal sizederived from natural sources)
2.25 (a) Excavating, supplying and filling of local earth (including royalty) by mechanical transport up to a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth,sides of foundation etc. complete.
10.14 Providing and fixing pressed steel door frames conforming to IS: 4351,manufactured from commercial mild steel sheet of 1.60 mm thickness,including hinges, jamb, lock jamb, bead and if required angle thresholdof mild steel angle of section 50x25 mm, or base ties of 1.60 mm,pressed mild steel welded or rigidly fixed together by mechanical means,including M.S. pressed butt hinges 2.5 mm thick with mortar guards,lock strike-plate and shock absorbers as specified and applying a coatof approved steel primer after pre-treatment of the surface as directedby Engineer-in-charge: 10.14.2 Profile C 10.14.2.1 Fixing with adjustable lugs with split end tail toeach jamb
9.1 9.21 Providing and fixing ISI marked flush door shutters conforming to IS :2202 (Part I) non-decorative type, core of block board construction withframe of 1st class hard wood and well matched commercial 3 plyveneering with vertical grains or cross bands and face veneers on bothfaces of shutters: 9.21.1 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws sqm 2015.75
10.16 Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. 10.16.3 Electric resistance or induction butt welded tubes
12.50 Providing and fixing precoated galvanised iron profile sheets (size,shape and pitch of corrugation as approved by Engineer-in-charge)0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineerin-charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost ofpurlins, rafters and trusses and including cutting to size and shape wherever required.
13.7 12.4 Providing ridges or hips of width 60 cm overall width plain G.S. sheet fixed with polymer coated J or L hooks, bolts and nuts 8 mm dia G.I. limpet and bitumen washers complete. 12.4.2 0.63 mm thick with zinc coating not less than 275 gm/m² metre 750.85
13.7 12 mm cement plaster finished with a floating coat of neat cement of mix : 13.7.1 1:3 (1 cement: 3 fine sand)
Item No. 12 mm cement plaster of mix : 13.4 13.4.1 1:4 (1 cement: 4 coarse sand)
13.2 15 mm cement plaster on the rough side of single or half brick wall of mix : 13.2.2 1:6 (1 cement: 6 fine sand)
11.3 Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete. 11.3.1 40 mm thick with 20 mm nominal size stone aggregate
13.80 Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wallsurface to prepare the surface even and smooth complete.
13.41 Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gms/litre, of approved manufacturer, of required shade and colour complete, as per manufacturer's specification. 13.42.1 Two or more coats on new work
13.46 Finishing walls with Acrylic Smooth exterior paint of required shade : 13.46.1 New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm)
11.41 Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete. 11.41.2 Size of Tile 600x600 mm
12.52.2 Providing and fixing tiled false ceiling of specified materials of size 595x595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 grams/ sqm, both side inclusive) consisting of main "T" runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200 mm center to center and cross "T" of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main"T" at 600 mm center to center to form a grid of 1200x600 mm and secondary cross "T" of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main "T" runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanised butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mm center to center along main Tbottom exposed width of 24 mm of all T-sections shall be pre- painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer-in-charge.
9.48 Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. 9.48.2 Fixed to openings /wooden frames with rawl plugs screws etc Using 10mm Square bars
21.1.2 For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately) 21.1.2.1 Anodised aluminium (anodised transparent or dyed to required shade according to IS: 1868, Minimum anodic coating of grade AC 15)
21.3 Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item): 21.3.2 With float glass panes of 5 mm thickness (weight not less than 12.50 kg/sqm)
9.70 Providing and fixing IS : 12817 marked stainless steel butt hinges with stainless steel screws etc. complete :
9.63 Providing and fixing ISI marked oxidised M.S. tower bolt black finish,(Barrel type) with necessary screws etc. complete :
9.62 Providing and fixing ISI marked oxidised M.S. sliding door bolts with nuts and screws etc. complete
9.81 Providing and fixing bright finished brass handles with screws etc.complete:
ELECTRICAL 1.14 Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required 1.14.2 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
1.14.3 2 X 4 sq. mm + 1 X 4 sq. mm earth wire
1.14.4 2 X 6 sq. mm + 1 X 6 sq. mm earth wire
1.10 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required. 1.8.2 Group B
1.12 Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit along with 1 No 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.
Supplying and fixing metal box of following sizes (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc. as required. 1.22.5 180mm x 100mm x 60mm deep
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 2 Nos. 3 pin 5/6 A modular socket outlet and 2 Nos. 5/6 A modular switch, connections etc. as required. (For light plugs to be used in non residential buildings).
1.23 Supplying and fixing following piano type switch/ socket on the existing switch box/ cover including connections etc. as required. 1.23.1
1.23.4 3 pin 5/6 amp socket outlet
1.25 Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
2.14 Supplying and fixing following rating, double pole, (single phase and neutral), 240 volts, residual current circuit breaker (RCCB), having a sensitivity current up to 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required. 2.14.1 25 amps
2.3 Supplying and fixing following way; single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 2.3.3 2+8 way Double door
2.3.4 2 + 12 way, Double door
2.10 Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, 'C' curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. 2.10.1 Single pole
2.12 Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required 63 A
5.2 Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal coke and salt as required.
5.6 Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal coke and salt as required.
5.7 Supplying and laying 5 SWG G.I. wire at 0.50 metre below ground level for conductor earth electrode, including connection/ termination with GI thimble etc. as required.
5.13 Providing and laying earth connection from earth electrode with 4.00 mm dia copper wire in 15 mm dia G.I. pipe from earth electrode including connection with copper thimble excavation and refilling as required.
Anx-1 Supplying fitting & fixing of surface and wall mounted LED batten Model CCS-103-20SL-DP-NWH CROMPTON make or equivalent for 20 W
Anx-2 Supplying of following A.C. ceiling fan complete with all accessories like down rod, canopy etc of following sweep as approved by the department as reqd complete and as directed by the department (Without regulator) Aero King Hevells 5 Star Model
Anx-3 Supplying with fitting & fixing of round recessed mount 18 W LED edge lit slim down light with die-cast aluminum housing finished in premium white powder coating efficiency 100 lm/w complete as specified and directed by the department Crompton make MAKE LSCSM-18 W CDL
Anx-4 Supplying with installation, testing and commissioning Hi-wall 4 star rating split type air conditioner of the following capacity with cordless remote complete with copper pipe and electrical connection cable as approved by the Deptt. up to 5 M between the room and out door unit as directed by the deptt. 1.5 T (Voltas, Carrier, BluStar, Daikin make) (Addl. Chief Engineer PWD Electrical approved rate)
Anx-6 Supplying with fitting and fixing complete Numeric Online UPS of rating 7.5 KVA with battery back up time 240 Minutes as directed and required by the department.
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.58 MB
BidDocument.pdf
Tender Documents • 4.76 MB
FOBITIELect.pdf
Additional Documents • 0.71 MB
BOQ_78359.xls
BOQ • 0.38 MB
Download all tender documents and submit your bid