GE (SOUTH) PATHANKOT
REPAIR MAINT OF SECURITY STREET GARDEN GATE LIGHT PERIMETER ILLUMINATION SYSTEM INCLUDING CONTROL PANELS AND MAINT OF DG SET CONEECTED SWITCH GEAR AT DEPOT AND DOMESTIC AREA 18 FAD UNCHIBASSI UNDER GE(S) PATHANKOT
2021_MES_488171_1
GES/PKT/T-36/2021-22
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE (SOUTH) PATHANKOT
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
GE (SOUTH) PATHANKOT
₹30,000
Yes
18 Feb 2022
13 Nov 2021
11 Dec 2021
13 Nov 2021
9 Dec 2021
29 Nov 2021
Amount
Excavation in trenches not exc 1.5 mtr wide and not exc 1.5 mtr deep hard /dense type of soil getting out and levelling of bottom surface to required level for poles/stay assebly/ cable, complete all as specifed and directed.
Returning filling in, including spreading, leveling, watering and well ramming in layers not exc 25m thick, complete all as specifed and directed.
Removing excavated material from site to a distance not exc 50 mtr away and depositing where directed not exc 1.5mtr from the starting point all as directed.
M&L for Sub class ‘B’ bricks old size laid dry flat over the cable abutting each other, length of cable equal to width of brick all as required.
Supplying & Laying in trenches clear sand for cushioning under ground cable 8 cm below and 15 cm above complete in level all as specified.
Laying only old bricks retrieved from item No.1 of any size/type laid along alignment of cable as protection to cable in trenches complete all as specified and directed by Engineer-in-Charge
Removing existing 1100 volts grade, XLPE/PVC, armoured, electric power cables (heavy duty) with aluminium conductor of sizes 6 Sqmm 4 core to 70 Sqmm 3.5 core from trench/ duct/ pipe carefully for identifying the defects and relaying the same after rectification of defects complete all as directed. Note: Earth work ( Excavation, Returning & refilling and removal), sand cushining , cable protection cover, GI protection pipe shall be measured and paid for seperately under respective item of Schedule
Supply and lay cable XLPE insulated armoured heavy duty electric cable with aluminium counductor, 1100 volts grade of crosssectional area 16 Sq mm 2 core.Note: Earth work ( Excavation, Returning & refilling and removal), sand cushining , cable protection cover, GI protection pipe shall be measured and paid for seperately under respective item of Schedule
Supply and lay cable XLPE insulated armoured heavy duty electric cable with aluminium counductor, 1100 volts grade of crosssectional area 16 Sq mm 4 core. Note: Earth work ( Excavation, Returning & refilling and removal), sand cushining , cable protection cover, GI protection pipe shall be measured and paid for seperately under respective item of Schedule
All as per Srl item No 09 above but of size 25 Sq mm 3.5 Core
All as per Srl item No 09 above but of size 35 Sq mm 3.5 Core
All as per Srl item No 09 above but of size 50 Sq mm 3.5 Core
All as per Srl item No 09 above but of size 90 Sq mm 3.5 Core
Supplying and fixing in replacement of old u/s service cable size 10 sqmm, twin core multistranded 1100 volts grade heavy duty cable PVC insulated aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service with galvanised steel wire complete all as spd and directed.
Material, labour , testing & commissioning of straight through jointing kit, heat shrinkable type suitable for XLPE/ PVC cables of size 10 to 16 Sqmm 3.5/4 core with working voltage 1100 volts .
Material, labour , testing & commissioning of straight through jointing kit, heat shrinkable type suitable for XLPE/ PVC cables of size 25 3.5/4 core to 70 Sqmm 3.5/4 core with working voltage 1100 volts .
Material, labour , testing & commissioning of straight through jointing kit, heat shrinkable type suitable for XLPE/ PVC cables of size 95 3.5/4 core to 400 Sqmm 3.5/4 core with working voltage 1100 volts .
M&L for GI pipe light grade 40 mm dia for cable protection on road crossings /plinth protection with fixed to the pole wall etc. suitable fittings for cable protection .
M&L for GI pipe light grade 50 mm dia for cable protection on road crossings /plinth protection with fixed to the pole wall etc. suitable fittings for cable protection .
Taking down defective LED street light fitting of any size/capacity from height of pole/walls/high mast of any location exceeding 7.0 m height for repair work and re-fixing back after repair work including checking, inspecting, testing and commmissioning complete all as directed by Engr-in-Charge. Note:a) The M/L for Items like electronic drivers,surge protection devices etc shall be measured and paid separately under relevant items here in under this Schedule. b) Necessary tools like ladders & other T&P required etc shall be arranged by the Contractor. c) The rate quoted deemed to be inclusive for minor parts nut bolts, circle clips, clamps etc if any required at site.d) The M/L for repairs to LED panel is not included in the scope and shall be measured and paid separately.
Supply and fixing in replacement of Surge protection device of capacity 10 KV suitable for LED light fitting
Supply and fixing Electronic driver potted type IP-65, suitable for 200 to 300 W LED light fitting complete all as specified.
Supply and fixing Electronic driver potted type IP-65, suitable for 125 to 180 W LED light fitting complete all as specified.
Supply and fixing Electronic driver potted type IP-65, suitable for 90 to 120 W LED light fitting complete all as specified.
Supply and fixing Electronic driver potted type IP-65, suitable for 70 to 80 W LED light fitting complete all as specified.
Supply and fixing Electronic driver potted type IP-65, suitable for 30 to 60 W LED light fitting complete all as specified.
Supply & fixing in repair LED Flood light fittings on rail/ steel tubular poles of height not exceeding 7.5 mtrs, comprising of epoxy powder coated housing, enclosed with glass cover in frame, of minimum wattage 100 Watts (with total lumen output not less than 10000 lumens and suitable wattage for efficiency not less than 100 lumens/Watt) with ingress protection IP 65/66 and SPD of capacity 10 KV etc including necessary clamps etc complete and testing on completion all as specified and as directed. Note : (i) MS Clamp fittings with nut bolts and GI bracket will be measured and paid separately.(ii) Minimum 2 years guarantee period of LED fittings (iii) Driver shall be IP 66 degree of protection potted seal type with inbuilt SPD and external SPD of capacity 10 KV to be provided in addition to inbuilt. (iv) Power factor more than 0.9 (v) Contractor shall submit LM 79 and LM 80 test reports from manufacturer from approved laboratory.
Supply & fixing in repair LED street light fittings on rail/ steel tubular poles of height not exceeding 7.5 mtrs, comprising of epoxy powder coated housing, enclosed with glass cover in frame, of minimum wattage 90 Watts (with total lumen output not less than 9000 lumens and suitable wattage for efficiency not less than 100 lumens/Watt) with ingress protection IP 65/66 and SPD of capacity 10 KV etc including necessary clamps etc complete and testing on completion all as specified and as directed. Note: The GI pipe bracket if required will be measured and paid separately under relevant schedule items. (ii) Minimum 2 years guarantee period of LED fittings (iii) Driver shall be IP 66 degree of protection potted seal type with inbuilt SPD and external SPD of capacity 10 KV to be provided in addition to inbuilt. (iv) Power factor more than 0.9 (v) Contractor shall submit LM 79 and LM 80 test reports from manufacturer from approved laboratory.
Supply & fixing in repair LED street light fittings on rail/ steel tubular poles of height not exceeding 7.5 mtrs, comprising of epoxy powder coated housing, enclosed with glass cover in frame, of minimum wattage 72 Watts (with total lumen output not less than 7200 lumens and suitable wattage for efficiency not less than 100 lumens/Watt) with ingress protection IP 65/66 and SPD of capacity 10 KV etc including necessary clamps etc complete and testing on completion all as specified and as directed. Note : (i) MS Clamp fittings with nut bolts and GI bracket will be measured and paid separately.(ii) Minimum 2 years guarantee period of LED fittings (iii) Driver shall be IP 66 degree of protection potted seal type with inbuilt SPD and external SPD of capacity 10 KV to be provided in addition to inbuilt. (iv) Power factor more than 0.9 (v) Contractor shall submit LM 79 and LM 80 test reports from manufacturer from approved laboratory.
Earthing complete with Galvanised Steel earthplate of size 60x60cmx6.3mm thick electrode and GI wire 8 sqmm dia as earth lead, buried directly in ground (earth pit not less than 2.25m deep below ground level) with top edge of the plate not less than 1.5m below ground level, connected to earth wire 4 sqmm by means of nuts, bolts, check nuts and washers of GI all as shown in electrical plate No.3 of SSR Part-I, including testing on completion (Rates inclusive of neccessary excavation in any type of soil, earth work, PCC pit, CI cover, funnel with watering pipe, suitable size of light grade GI Protection pipe for earth strip in ground etc. all as required at site for complete earthing).
Material and Labour for Galvanised iron round bracket made out of 40mm dia GI tubing including making provision for fixing of 04/06 no flood light on 11 mtr steel tubular pole ad fixing and connecting up of LED lights (LED lights shall be measured seperately under respective items of sch ) complete all as specified and directed. Note: The inner diameter of ring shall not be less than 1.0 meter
S&F in repair PVC insulated 3 core 2.5 Sq mm stranded Aluminium conductor cable for connecting OH line/junction box to street light fitting testing and commissioning all as directed.
Cutting the tarmac / hard standings and excavating in trenches across the road for laying cable including making good the excavated portion by means of PCC 1:3:6, type C1 matching with the surroundings all as directed.
M&L for bracket for street light fitting made out of 40 mm bore pipe light grade GI tube bent to shape required, not less than 1.20 meter long, fixed with and including MS flat iron clamps made out of 40x6 mm FI, bolts, nuts, washers etc complete including dismantling old defective.
M&L for bracket for street light fitting made out of 25 mm bore pipe light grade GI tube bent to shape required,not less than 1.20 meter long, fixed with and including MS flat iron clamps made out of 40x6 mm FI, bolts, nuts, washers etc complete including dismantling old defective.
S&F in repair powder coated Mild steel junction box wtih MCB SP 03-10 Amps-01 No outdoor type , CRCA sheet with front openable hinged door , locking arrangements with 4 Nos Aluminum bus bars , 200 Amps, mounted on porcelain insulator, glands and lugs etc. and fixed to pole/ PTL post etc with suitable size flat iron clamps, nuts , bolts complete including taking down all as specified and directed.
S&F in replacement of bus bar chamber including taking down with MCB SP 10-16 Amps-01 No outdoor type made out of MS sheet 3mm thick with copper bus bar three phase & neutral fixed with insulators and fixing on pole with proper clamps, nuts , bolts & washers of required size and making connection of LT cables with thimbles and making good the disturbed wall surfaces incl water proof PVC sticker like danger mark all as required at site.
Scraping of old paint from the HT/LT pannel/bus bar fixed along PCC plinth without removing and preparation of surfaces for repainting externally. Repainting the bus bar /pannel complete externally by applying one coat of synthetic enamel paint incl fencing jali of approved colour and also repainting the plinth as per directed
Taking down old burnt out MCCB (of any size, make ,shape ) and supply and fixing new MCCB with the existing cable after making it good by cutting out the burnt parts of the cable/lugs, crimping new lugs as per the suitable size, connecting with the new MCCB along with spraders, testing complete all as directed and specified
(i) MCCB 04 pole of 250 current rating with rapturing capcity of 35 KA, 415V, 50Hz, (Thermal magnetic release) Ics=100%Icu and adjustable overload setting 80% to100% complete all as specified
(ii) MCCB 04 pole of 160 A current rating with rapturing capcity of 25 KA, 415V, 50Hz, (Thermal magnetic release) Ics=100%Icu and adjustable overload setting 80% to100%, complete all as specified
(iii) MCCB 04 pole of 125 A current rating with rapturing capcity of 25KA, 415V, 50Hz, (Thermal magnetic release) Ics=100%Icu and adjustable overload setting 80% to100% complete all as specified
(iv) MCCB 04 pole of 100 A current rating with rapturing capcity of 25KA, 415V, 50Hz, (Thermal magnetic release) Ics=100%Icu and adjustable overload setting 80% to100% complete all as specified
(v) MCCB 04 pole of 200 A current rating with rapturing capcity of 25 KA, 415V, 50Hz,(Thermal magnetic release) Ics=100%Icu and adjustable overload setting 80% to100%, complete all as specified
(v) MCCB 04 pole of 63 A current rating with rapturing capcity of 16 KA, 415V, 50Hz ,(Thermal magnetic release) Ics=100%Icu and adjustable overload setting 80% to100%, complete all as specified
Disconnecting and removing existing unserviceable battery and S&F maintenance free battery 12V 180 AH including terminal clamps, copper lead 3m long each including testing and commissioning all as directed by Engineer-in-Charge.
Taking down old unserviceable security light fitting from fitting from any height and supply & fixing in repair Solar smart intergreted Solar LED street light fitting (All in one) with built in Mono Crystallline Panel, lithiumion battery (LiFe PO4) MPPT Charger controller, PIR sensor with colour temp 600-6500K with minium 40 W capacity LED light fitting with hybrid switch, Mono cryslling solar panel of capacity 48+ 4W (mono), PIR sensor ,IP65, 12.8V, 27 Ah lithium ion (LiFe Po4) battery inbuilt in fitting MPPT charger controller with efficiency > 90% CRI> 70, autonomy for minimum 2 days , charging time 1 day , suitable for workingtemeratures -10 Degree C to +55 Degree C, fixed on 9.0 Meter Pole complete all as specified and directed by Engr In charge Note -rate inclusive of fitting, battery , controller etc complete.
Fixing only solar light with complete accessories of any size and capacity including GI pipe of suitable size up to 7 mtr hight from the ground levevl at the given site complete all as specified and directed by Ingr In charge
Supply & fix replacement decorative path way light lighting LED decorative post top lantern for 360 degree 40 watts 230 volts, 50 HZ, maple shaped in sothing opal/ prismatic finish made up of polycarbonate,including all accessories prewired complete.Note :- (i) Minimum 2 years gaurntee period of LED fittings (ii) Driver shall be IP 66 degree of protection potted seal type. (iii) Power factor more than 0.9
S&F in repair Capacitor duty contactor with 1 No Aux contact 230V AC coil voltage suitable for minimum 10 KVAR capacitor.
S&F in repair Capacitor duty contactor with 1 No Aux contact 230V AC coil voltage suitable for minimum 25 KVAR capacitor.
M&L in replacement of existing unserviceable contactor current carring range 9 A to 18 Amp (AC-3 duty) at different places in APFC panels including required electrical connections with suitable size of single core pvc copper cable & testing all as directed .
M&L in replacement of existing unserviceable MCB 25-40 Amps TPN 415 volts at different places in LT Panels/APFC panels including required electrical connections & testing all as directed .
M&L in replacement of existing unserviceable MCB 32 - 63 Amps TPN 415 volts at different places in LT Panels/APFC panels including required electrical connections & testing all as directed .
Maintenance and servicing of DG set consisting of replacement of fuel filter, air filter and lub oil filter including replacement of eninge oil all as directed and testing on full connected load for the capacity of 100 KVA to 160KVA DG Sets and any make as per OEM.Note: Engine oil will be measured and paid seperately.
All as per Srl item No 56 above but for capacity of 320 KVA DG Set.
M & L for replecement of existing unservicible Fan Belt and testing complete for the capacity of 100 KVA to 160KVA DG Sets and any make as per OEM.
All as per Srl item No 58 above but for capacity of 320 KVA DG Set.
M & L for replecement of existing unservicible Hose Pipes with clamps and testing complete for the capacity of 100 KVA to 160KVA DG Sets
All as per Srl item No 60 above but for capacity of 320 KVA DG Set.
Taking out the old unserviceable radiator from the DG set and taking it to work shop for overhauling & cleaning descaling with restore plus solution, removal of leakage, welding brazing & refixing it duly repaired etc complete all as directed for the capacity of 100 KVA to 160KVA DG Sets and any make as per OEM.
All as per Srl item No 62 above but for capacity of 320 KVA DG Set.
M/L for cleaning the fuel tank both internally and externally by removing all the dust / sediments etc including replacement of PVC pipe fuel level indicator, writing of tank capacity, date of cleaning and next due date for tank to be cleaned for capacities of 100 KVA to 160 KVA DG Set and any make as per OEM.
All as per Srl item No 64 above but for capacity of 320 KVA DG Set.
M&L for repair and overhauling of unsv self starter 12 V/24V of any capacity DG set including repair/replacement unsv/defective spares such as field coil, armature winding, carbon bushes, clutch bushes and pinion assy complete all as specified and directed.
M&L for repair and overhauling of unsv dynamo/alternator 12 V/24V of any capacity DG set including repair/ replacement unsv/defective spares such as field coil, armature winding, carbon bushes, clutch bushes and pinion assy complete all as specified and directed.
S & F in repair Hour meter 6 Digit, LCD, Terminal connection 9-64 v ,10- 60VDC of any capacity DG set complete all as specified and directed.
S&F in repair AVR with functions to adjust generator output voltage, prevent voltage hunting, set under frequency roll off knee point, set generator droop to 5% at full load, match AVR input to accessory output, set the over excitation cut off level, set intial frequency related voltage dip, over-voltage protection cut off level, maximum short circuit current with sensing input voltage range 170 - 250 V AC max, 50 -60 HZ frequency with output max upto 120 V DC, continuous current 2.7A & transient 6A for 10 sec including necessary control wiring complete from alternator to AVR complete testing & commissioning for DG sets of capacity 160 to 320 KVA.
Taking out the old unserviceable battery from the DG Set and supply and fix new 12 V, 180 AH maintenance free battery make Amron/Exide including testing and commissioning complete all as specified and directed
M & L for repair of Water pump of 320 KVA DG set including replacement of defective unsv spare part of any make and model and refix the same after repair complete all as specified and as directed
M & L for repair of Water pump of 100 to 160 KVA DG set including replacement of defective unsv spare part of any make and model and refix the same after repair complete all as specified and as directed
M&L for Calibration of Fuel pump including replacement of unsv/defective spares of 320 KVA DG Set of any make and model complete all as directed.
M&L for Calibration of Fuel pump including replacement of unsv/defective spares of 100 to 163 KVA DG Set of any make and model complete all as directed.
M&L for overhauling and calibration of fuel injector assembly including replacement of unsv/defective spares of 320 KVA DG Set of any make and model complete all as directed.
M&L for overhauling and calibration of fuel injector assembly including replacement of unsv/defective spares of 50 to 63 KVA DG Set of any make and model complete all as directed.
Supply and fix in replacement battery leads set, PVC insulated multisranded, copper conductor of min size 35 sqmm 1 mtr long each duly fixed with brass clamps, copper lugs suitable for DG sets of different capacities.
M/L for replacement of coolant for radiator for DG set at various locations.Make: Servo/HP/Indian Oil.
M/L for replecement of Lub Oil (Engine Oil) of grade 20W40 for Engine for DG set at various locations.
M & L for replacement of starter ring gear assembly for capacity 320 KVA DG set.
Shifting of DG Set from Depot pump house to Domestice pump house of capacity 40KVA to 63 KVA at 18 FAD Uchibassi.
Material & Labour for taking down the defective split/Window unit of the following capacity, shifting to work shop, taking out the defective unserviceable hermetically sealed compressor from the unit, replacing the compressor with new compressor of the same capacity, fixing to the unit inter connecting the refrigerating lines, flushing out the cooling coil & condenser, removal the coil & carbon thoroughly, cleaning with CTC, leak testing, pressure testing with Nitrogen gas, dehyderating, Vaccumissing, charging of Refrigerant gas, testing at work shop. Shifting to the location reinstalling the same in its Original position connecting up all etestion electrical, connection and Testing & Commissioning. All as specified as directed by Engineer-in-Charge. Note : Rate quoted is deemed to be inclusive of cutting, welding, brazing, sealing the refrigerant tubing, replacement of strainer, CTC, Nitrogen gas, Refrigerant gas, required to and from Transportion and Handling. M/L for spares will be measured and paid separately Make of AC unit shall be, carrier / Voltas / LG / Blue Star, Videocon, Usha
1.5 TR Capacity
2 TR Capacity
Material and Labour for taking down the damage condenser fan blade of 1.5TR split/Window type AC’s of any make and supply & fixing suitable new fan blade and testing & commissioning the unit.
All as per Item No. 84 above but for 2 TR Split AC
Material and Labour for taking down the damaged blower unit of any make split/Window AC and supply and fixing of new blower unit of suitable type and testing & commissioning the unit.
Material and Labour for complete scraping out the crusting painting of the complete body of out door unit metallic surface, cleaning the surface thoroughly, apply putty / metal paste, prepare the surface, apply 2 coat of synthetic enamel paint over a coat of red oxide primer for 1.5 / 2TR capacity split type AC’s.
Material and Labour for cleaning flushing the refrigeration system thoroughly with CTC, and Nitrogen gas, leak testing and locating the leaks, rectifying the leaks, by brazing the joints, replacing the damaged copper pipes, silver rod/ copper. Pressure testing, dehydrating, vaccumissing, gas charging testing & commissioning the system the work includes required strainer, N2 gas, Refrigeration gas and transportions Handling the unit, complete all as specified directed.
1.5 TR Capacity
2 TR Capacity
Material and Labour for taking down the unserviceable temperature sensor probes and supply & fixing new sensor probe suitable for any type, make split/Window type AC’s and testing & commissioning.
Material and Labour for taking down the defective unserviceable printed circuit Board and S/F of new printed circuit board for any make split/window type AC unit.
Material and Labour for taking down the defective unserviceable sealed fan motor & S&F new fan motor of the same capacity & size to suit the split/window AC unit of any make and capacity of 1.5 / 2 TR all as per existing at site
Material and Labour for taking down the damaged air filter set and S/F of new air filter set for split/window type AC’s of 1.5 / 2TR capacity.
Material and Labour for taking down the defective unserviceable starting/running capacitors 80/100 MFD 230V / 50Hz and supply and Fixing the new starting capacitor of the same capacity to split / window type AC’s and testing.
Material and Labour for taking down the defective unserviceable starting relay and supply and fixing new rely suitable for 1.5/2TR Window / Split type AC’s and Testing.
Material and Labour for taking down the defective unserviceable Thermostatic switch and S/F new thermostatic suitable for window type AC’s and Testing.
Material and Labour for taking down the damaged drain pipe and S/F of new insulated drain pipe suitable for split type AC’s.
Material and Labour for taking down the defective capillary tube set and supply & Fixing new suitable capillary set for split type AC’s.
Material and Labour for taking down the rusted out door unit stand and supply & fixing the stand with required anchor fastner and nut & bolts and rubber bushes for 1.5 / 2 TR Split unit.
Material and Labour for taking down the burned out door unit fan motor and rewinding, overhauling renewal of worn out shaft & bushes, and fixing to the unit, of 1.5 / 2 TR Split units.
Material and Labour for taking down the defective remote control unit and S/F of new remote control unit for split/window type AC of 1.5 / 2 TR of any make and testing.
Material and Labour for taking down the defective definite purpose magnetic contactor of the split/window AC’s of any make, and supply & fixing of new contactor of 240 VAC. 30 Amps 50 Hz, and coil volt of 208/240V 50/60Hz and Testing.
Material and Labour for taking down the defective unserviceable sealed motor of indoor unit of any make split unit of 1.5/2 TR capacity and S/F new fan motor suitable for Split type AC’s.
Material and Labour for taking down the defective starting capacitor of split / window type AC’s and supply & fixing the new starting capacitor of 80/100 MFD 230V, 275SV-50Hz and Testing for 1.5/2TR AC Unit.
Material and Labour for taking down the burned wiring kit and supply & fixing and testing of new wiring kit suitable for 1.5/2TR split and window type Ac unit.
Material and Labour for taking down by disconnecting water connections and shifting elective water cooler to work shop, taking down the defective sealed compressor and replacing with new compressor, the work includes flushing the complete system condenser, cooling coil with Nitrogen, removal all carbon, oil & dirt, brazing & inter connecting the refrigeration lines, de-hydrating, purging with refrigerant, vaccumissing and charging of R22 / 134a Refrigerant and testing & commissioning and shifting to original location and connecting up the electrical & water connection for the following capacity water coolers. All as specified as directed by Engineer-in-Charge.
40/60/80 Ltrs. capacity water cooler
120/150 Ltrs. capacity water cooler
Material and Labour for complete tinkering the corroded sheet metal parts, side panel, door, with existing gauge M.S. Sheet and renewal of the bottom base plate, mounting lets, fan motor base plate, and condenser should cover etc, with existing size gauge G.I. sheet, with required Angle Iron, Nut & Bolts all as per the existing size and shape including cutting, bending, welding and completing fixing all other components, complete scraping with old paint, prepare the surface, painting 2 coat of enamel paint over a coat of primer and complete cleaning the water tank and shifting to the location and testing any capacity of water coolers. All as specified as directed by Engineer-in-Charge.
Material and Labour for charging the water cooler of the following capacitor including taking down, transporting to workshop flushing out the cooling coil, condenser, brazing the refrigerant lines, replacing of liquid line copper strainer, leak testing, purging with refrigerant, vaccumissing and charging of R22/R 134a gas, testing & commissioning and shifting to the location and connecting up the electrical & water connection. All as specified as directed by Engineer-in-Charge.
a) 40/60/80 Ltrs. capacity water cooler
b)120/150 Ltrs. capacity water cooler
Material and Labour for painting the water cooler including scraping out the old paint prepare the surface, painting 2 coat of enamel paint over a coat of primer, the work including necessary putty, metal paste etc., and disconnecting from the position and refixing after painting for any capacity of the water coolers.
Material and Labour for to the water cooler tank and cooling coil by dismantling the water cooler and carried out the lead soldering to cooling coil to the tank outer surface where ever the detached portion and rectify the leaks portion and re-assembly the water cooler of any capacity.
Material and Labour for taking down the damaged thermal insulation of the water cooler, and renew the thermal insulation as per the existing thickness and assembling the body with necessary sheet metal screws etc., for any capacity water coolers.
Material and Labour for taking down the defective starting relay and S/F of new starting relay for any capacity water cooler.
Material and Labour for taking down the defective overload relay and S/F of new over load relay suitable for any capacity water cooler.
Material and Labour for taking down the defective Running capacitor and Supply & Fixing new running capacitor 20/10 MFD, 440 VAC 50/60 Hz suitable water cooler.
Material and Labour for taking down the defective starting capacitor and Supply & Fixing new starting capacitor 60/80 MFD, 230V, 270SU-50 Hz for water cooler upto 120 Ltrs. Capacity.
Material and Labour for taking down the defective Running capacitor and Supply & Fixing new running capacitor of 25/36 MFD, 440 VAC, 50/60 Hz suitable for 150 Ltrs. Capacity water cooler.
Material and Labour for taking down the defective thermostatic switch and Supply and Fixing of new thermostatic switch for water coolers.
Supply and Fixing of Left/Punch cook for water cooler of any capacity.
Supply and Fixing float valve for water cooler of any capacity
Material and Labour for taking down the damaged drain connections and drain pipe and S/F of new drain connection & pipe with necessary clamps, Nipple, coupling etc., for any capacity water cooler.
Material and Labour for taking down the defective unserviceable sealed fan motor and S/F new fan motor with suitable capacitor for water cooler upto 40/80, 60/120 ltrs. Capacity.
Material and Labour for taking down the damaged condenser fan blade and supply and fixing of new fan blade suitable for 40/60/80 water coolers.
Material and Labour for taking down the corroded air cooler condenser and supply and fixing of new air cooled condenser with necessary brackets and fixing arrangements including welding brazing etc., for water cooling 40/60/80 Ltrs. Capacity.
Material and Labour for taking down the complete corroded sheet metal body of out door unit of split unit and supply and fixing of new out door unit suitable 1.5 TR split unit the work includes dismantling the components and reassembly and fixing to the existing location and testing for any make of split unit.
Material and Labour for taking down the complete corroded sheet metal body of indoor unit of split unit and supply and fixing of new indoorunit suitable 1.5 TR split unit the work includes dismantling the components and reassembly and fixing to the existing location and testing for any make of split unit.
Material and Labour for taking down the corroded air cooled condenser and supply and fixing of new air cooled condenser suitable for 1.5 TR Split Ac
Material and lbour for taking down complete old corroded, unserviceable window AC of 1.5 Ton capacity and depositing to MES Store and supply and fixing a new window AC of 1.5 Cpacity
M & L sub-main wiring with 4.0 Sq.mm (nominal area) PVC unsheathed multi strandard copper conductor PVC insulated 1100 volt grade single core cable drawn through and including rigid PVC conduit medium grade minimum 20mm size and its accessories complete along with 4.0 Sqmm cable but in green colour as continuous earthing wire and connecting to common earth dolly completely concealed ,surface,in walls/ceiling/roofs all as directed and specified including dismantling old one Note : Three runs of PVC copper cable and one run of PVC conduit will be measured as one Rm.
Material and Labour for complete carryout the servicing to Split/Window type AC’s including taking down from the position, dismantling the sheet metal parts, blowing out the dust, carryout the chemical cleaning to chocked cooling coil & condenser coil, by spray the dilated chemical cleaning agent, till remove complete chocking, flushing across the coils, cleaning all the sheet metal parts, filter, grill and fixing all the dismantled parts with sheet metal screws, lubricating the fan motor bush / bearing, checking all the electrical connections, renew any burned legs / clip and fixing back to position and testing.(Note: Gas Charging if required will be measured and paid seperately).
Supply and charging refrigerant R-22 complete one time for topping up or making full qty including plugging the leakage complete and as directed.
Supply and charging the refrigerator gas R-134A / R-34A /R-407/any environmental friendly refrigerant gas complete all as specified and as directed.
Supply and charging compressor oil suitable for AC's, water cooler ,Refrigerator and deep freezer complete including testing etc, complete all as specified and as directed.
Removing the old paint of the body of refrigerator of any capacity and making the body dent proof and preparing the surface and Painting the refrigerator with 2 coats of synthetic enameled paint of superior quality to match with existing paint with spray painting complete all as specified and directed.
S & F in replacement Refrigirator of capacity 310 Ltrs complete
S&F in replacement of existing UNSV sealed Compressor unit for Refrigerator of capacity 165 to 185 Ltrs including Gas charging.
S&F in replacement of existing UNSV sealed Compressor unit for Refrigerator of capacity 285 to 320 Ltrs including Gas charging.
S&F in replacement of existing UNSV cooling Thermostat switch suitable for refrigerator/deep freezer of any capacity.
S&F four layered Rotational moulded polyethylene water storage tanks of capacity 5000 Ltrs (cylindrical vertical with closed top) hoisted and fixed in position coplete including dismantiling of old one al as specified as directed.
M/L for repairing and servicing the reciprocating sem-hermetic compressor of 50 TR capacity of Make: Accel of 3x50 TR Water cooled chiller type Central AC plant at Unchibassi, by opening the head covers, side inspection covers, crank case, valves assembly, both suction and discharge, check the wear and tear of the parts, cleaning the complete compressor with CTC/Petrol, flushing the capacity control loading and unloading circuit, reassembly the compressor by renewal of the defective spare parts and leak testing, charging R-22 gas and testing and commissioning the compressor including replacement of gasket set, ‘O’ ring set, suction and discharge ring plates, piston rings and star washers. Note: Motor rewinding of compressor, Gas, Spares & compressor oil will be measured and paid separately under relevant schedule items.
Supply only the following spares of reciprocating sem-hermetic compressor of 50 TR capacity of Water cooled chiller AC plant of capacity of Make: Accel for repair/ replacement under item no. 138 above
Piston complete with pin and ring set, connecting rods, gudgeon pin and circlip lock complete
Suction and discharge reeds including tension springs complete
O' ring set
Compressor gasket set
Cylinder liner with suction valve
Material and labour for dismantling and rewinding of Compressor motor suitable HP of capacity 50 TR of central AC Plant water cooled chiller type AC Plant including cutting and removing existing burnt/short circuited winding wire complete, cleaning of core grooves and surfaces, re-winding the motor with superior quality enamelled copper winding wire duly ISI marked of suitable gauge for same Nos of coils and turns including insulation material such as sleeves, lathorised fiber glass, cotton/PVC tape, varnish etc reassembling the motor and refixing the same with chiller unit of capacity 50TR and testing the same for the minimum period of 24 Hours complete all as specified and directed
Supply only the folllowing spares for refrigerant circuit of 3x50 TR of central AC Plant water cooled chiller type AC Plant suitable for repair/ replacement under item no. 140
HP Switch/sensor
LP Swicth/sensor
Material and labour for carrying out servicing/overhauling , repairs and maintenance of Cooling tower of 3x50 TR water cooled chiller type central AC plant by dismanlting /taking down the CT fan motor of flange mounted extended type shaft upto 2 HP, 3 phase, 415 volts, 50 Hz, along with fan assembly, and including cleaning & removeal of scales, inspection, cleaning and replacement of PVC fills, PVC eliminator, FRP louvers, motor cover, splash cups etc complete including renewal of all corroded bolts & nuts, terminal block, and re-assembling, fixing in position, fixing of fan blade, and alignment of the fan blade for the suitable air throw of the cooling tower,painting with two coats of synthetic enamel paint over a coat of anticorrosive paint after preparation of surfaces, testing & commissioning the cooling tower motor all as specified and as directed by the Engineer-in-Charge. Note: (a) The spares such as PVC fills, Fan assembly, CT fan motor, elimintaor, louvers, motor cover, branch pipe, splash cups etc deemed to be included in the quoted rate. (b) The rates inclusive for all T&P, chemicals required for cleaning, FRP compound, nut bolts etc complete for keeping the Cooling tower in operational condition.
Supply only spares for carrying Cooling tower of 3x50 TR water cooled chiller type central AC plant under relevant items:-
PVC FILLS 600X300X150 MM
Al sprinkler of 5" (125mm)
FRP motor cover
Supply and charging refrigerant R-22 complete one time for topping up or making full qty as per the pressure requirement of plant and testing for any leakage and rectifying the same as directed by Engineer in Charge and testing on full load condition for 8 Hrs period, complete all as specified and directed.
Supply only compressor oil for carrying out repairs under relevant items above, complete all as specified and directed.
Supply & Fixing of 100mm Dial Suction Pressure gauge suitable for R-22 Gas service with suitable adapter. Make: H-Guru/ Fiebig/Warfee
Supply & Fixing of capacity control solenoid valve of 3 way connection and suitable to operate in 230V 50Hz AC for SMC series ACCEL make compressor
M&L for servicing the Air handling units 8000 CFM capacity ( water cooled chiller type central AC plant ), with and including dismantling units, sheet metal parts, blowing out the dust, chemical cleaning by spraying the organic based scale removing agent (Vaniklin) at the appropriate ratio till removal of complete dust & scale deposits in the fin area of evaporator coil, flushing through for proper air flow across the coil, cleaning of expansion valve; greasing of blower motor, checking of electrical connection, cleaning of air filters,greasing of blower motor,replacement of un serviceable bearings, water drain lines, renewal of rusted sheet metal screws, applying synthetic enamel paint over a coat of primer on the rusted portion and testing & commissioning the unit all as specified and as directed by Engineer-in-Charge.Note : Quoted rate inclusive of replacement of AHU fan belts and M/L for pre-filters will be measured and paid separately.
Material and labour for descaling of condenser of 50 TR chiller plant by draining condenser water from equipments and pipes. Recirculating water inside the pipes with descaling liquid solution(Carbon Tetra Chloride Solution) and flushing out 3-4 times. Recirculating fresh water inside the pipes and flushing out five to six times so that descaling liquid is completely cleaned out along with Scales from the pipe line complete all respect.
M&L for dismantling the defective induction motor of any make, any duty or any class of insulation from the bed, duly coupled with pump/ compressor, transporting to workshop, removing burnt out winding from stator/ rotor, rewinding with suitable gauge of super enamelled copper wire of approved make and replacing drive end and non drive end bearings, insulation materials, varnishing, heating, re-assembling, testing and commissioning of the following capacities including replacing base frame bolts & nuts, complete all as specified and directed.
M&L for taking down mono block type water pumps of 10 to 20 HP by disconnecting the power supply cables, water lines both inlet & outlet, providing dummy flanges with gasket and overhauling pump sets, renewal of the worn out gland packages/ seal pack, bearings, bushes and gasket packing, greasing cleaning & removal of the scale in impeller, assembling the pump sets fixing in position, inter connecting the suction & discharges, connecting up the cable, testing and commission the following capacity pumps, complete all as specified and directed.
Supply and fixing in repairs 3 pole power contactor of 40 to 63 A rated operational current carrying capacity(AC3 duty), with coil operating voltage 230 V/ 415 V AC 50 HZ, complete all as specified and directed.
Supply and fixing in repairs overload relay with operating range 40 to 63 A, complete all as specified and directed.
M & L for Insulation of 65mm M S Pipe with nitrile insulation of 25 mm thick final finished with 26 G aluminium cladding complete of sizes as shown including dismanlting old worn out cladding, complete all as specified and directed.
S&F pre filter for AHU having 90% down to 10 Microns, complete all as specified and directed.
Note: In case the tenderer quotes different rates for similar item then lowest rate shall only be applicable for payment and contractor shall not have any claim on this account.
R K ENTERPRISES
JAI DURGA CONSTRUCTION CO
M/S SATPAL AND BROTHERS
GEE EMM ASSOCIATES
kailu construction co
WALIA ENTERPRISES
M/s SODHI SALES CORPORATION
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .