| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹49.8 LAdmitted-Finance LAKHIPUR PT I HOUSE NO 0 CITY TOWN CACHAR P O LAKHIPUR P S CACHAR DISTRICT CACHAR ASSAM PIN 78815 | 78815 | L1 | Admitted-Finance | |
| 2 | L2₹49.8 L+₹2,000 (0.04%)Admitted-Finance MOHANPUR PT II HOUSE NO 00 CITY TOWN KATIGORAH P O KATIRAIL P S KATIGORAH DISTRICT CACHAR PIN 788804 | CACHAR | ASSAM | 788804 | L2 | Admitted-Finance |
| Sl No | Description | Qty | Unit | Alok Kumar Paul L2 | DEY ENTERPRISE L1 |
|---|---|---|---|---|---|
| 1.00 | Construction of HP culvert- Earth work in excavation for structureas as per drawing and technical specification Cl;305.1, including setting out, construction of shoring and bracing,removal of stumps and other deleterious materials and disposal upto a lead of 50 m, dressing of sides and bottom and back filling in tranches with excavated suitable materials. Ordinary soil.(i)Up to 3.00m depth. | 86.73 | Cum | 134.47 ₹11,662.58 Lowest | 134.47 ₹11,662.58 Lowest |
| 2.00 | Providing Concrete for plain/reinforced concrete in open foundation complete as per drawing and technical specification Clause802,803,1202,&1203( PCC Grade M10) (I) nominal mix 1:3:6. | 9.76 | Cum | 6,357.1 ₹62,045.29 Lowest | 6,357.1 ₹62,045.29 Lowest |
| 3.00 | Brick masonary work in cement mortar 1:3 in sub-structure complete excluding pointing and plastaring as per drawing and technical specification Cl.600, 1202 &1203 (II)Brick Masonry 1:3 cement morter | 26.71 | Cum | 8,660.7 ₹2,31,327.32 Lowest | 8,660.7 ₹2,31,327.32 Lowest |
| 4.00 | Providing & laying reinforced cement concrete pipe NP3 as per designed in single row for culvert on 1 st class beddting of granular materials including fixing of collars with cement mortor 1:2 as per CL No. 1106. | 20 | Rm | 8,201.36 ₹1,64,027.22 Lowest | 8,201.36 ₹1,64,027.22 Lowest |
| 5.00 | Plastering with Cement Morter (1:4), 15mm thick on brick work in sub structure as per drawing & technical specification. | 35.26 | Sqm | 154.19 ₹5,436.68 Lowest | 154.19 ₹5,436.68 Lowest |
| 6.00 | Construction of RCC drain- Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material. | 132.68 | Cum | 134.47 ₹17,841.48 Lowest | 134.47 ₹17,841.48 Lowest |
| 7.00 | PCC M10(1:3:6 nominal mix) in levelling course below open foundation of Head walls as per drawing and technical specification clause 1109 | 9.15 | Cum | 6,357.1 ₹58,167.46 Lowest | 6,357.1 ₹58,167.46 Lowest |
| 8.00 | Supplying,fitting & placing TMT bar reinforcement in sub-structure complete as per drawing and Technical Specification clauses1000 & 1202. | 2.78 | MT | 67,084.7 ₹1,86,428.39 Lowest | 67,084.7 ₹1,86,428.39 Lowest |
| 9.00 | Supplying,fitting & placing TMT bar reinforcement in sub-structure complete as per drawing and Technical Specification clauses1000 & 1202. | 1.41 | MT | 70,099.27 ₹98,839.97 | 68,680.83 ₹96,839.97 Lowest |
| 10.00 | Providing concrete for plain/reinforced concrete in sub-structure complete as per drawings & technical specifications clause 802,803,1202 7 1203. (I)R.C.C Grade M 20.Nominal mix 1:2:4. | 35.69 | Cum | 7,877.8 ₹2,81,158.68 Lowest | 7,877.8 ₹2,81,158.68 Lowest |
Tender Value
₹49.8 L
EMD Value
₹99,700
Closing Date
22 Jan 2026, 4:00 pmClosed
EE, Patharkandi and RK Nagar TRD, RK Nagar
O/o the EE, Patharkandi and RK Nagar TRD, RK Nagar
PRTRD_PDNA_ET_25_26_22 Recovery and Reconstruction of damaged culvert on Bhanga to Bhairab Nagar road at Tatirgool with protection work and drain under NDRF (PDNA-2022) for the year 2025-26.
2026_PWD_50058_22
PRTRD/RKN/PDNA/ET/2026/1302
Open Tender
Civil Works
Item Rate
90 days
RK Nagar
Please refer Tender documents.
4 documents required · 4 mandatory
₹1,000
₹99,700
Yes
O/o the EE, Patharkandi and RK Nagar TRD, RK Nagar
14 Feb 2026
9 Jan 2026
28 Jan 2026
10 Jan 2026
22 Jan 2026
10 Jan 2026
10 Jan 2026 - 12 Jan 2026
12 Jan 2026
Construction of HP culvert- Earth work in excavation for structureas as per drawing and technical specification Cl;305.1, including setting out, construction of shoring and bracing,removal of stumps and other deleterious materials and disposal upto a lead of 50 m, dressing of sides and bottom and back filling in tranches with excavated suitable materials. Ordinary soil.(i)Up to 3.00m depth.
Providing Concrete for plain/reinforced concrete in open foundation complete as per drawing and technical specification Clause802,803,1202,&1203( PCC Grade M10) (I) nominal mix 1:3:6.
Brick masonary work in cement mortar 1:3 in sub-structure complete excluding pointing and plastaring as per drawing and technical specification Cl.600, 1202 &1203 (II)Brick Masonry 1:3 cement morter
Providing & laying reinforced cement concrete pipe NP3 as per designed in single row for culvert on 1 st class beddting of granular materials including fixing of collars with cement mortor 1:2 as per CL No. 1106.
Plastering with Cement Morter (1:4), 15mm thick on brick work in sub structure as per drawing & technical specification.
Construction of RCC drain- Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material.
PCC M10(1:3:6 nominal mix) in levelling course below open foundation of Head walls as per drawing and technical specification clause 1109
Supplying,fitting & placing TMT bar reinforcement in sub-structure complete as per drawing and Technical Specification clauses1000 & 1202.
Supplying,fitting & placing TMT bar reinforcement in sub-structure complete as per drawing and Technical Specification clauses1000 & 1202.
Providing concrete for plain/reinforced concrete in sub-structure complete as per drawings & technical specifications clause 802,803,1202 7 1203. (I)R.C.C Grade M 20.Nominal mix 1:2:4.
Plain/Reinforced cement concrete,in super-structure complete as per drawing & technical specification clauses 805,806,807, 1202 & 1204. (E) RCC grade M-20. (a) Height upto 5m.
Construction of retaining wall- Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material.
Providing concrete for plain/reinforced concrete in open foundation complete as per drawings and technical specification Clause 802 803 1202 & 1203.B.With natural Gravel.I. P.C.C grade M 10.(i) Nominal mix 1:3:6.
Supplying fitting and placing TMT bar reinforcement( Fe 415) in substructure complete as per drawings and technical Specification clauses 1002 and 1005.
Plain/Reinforced cement concrete in sub stucture complete as per drawing and technical specification Clause 802,804,805, 806,807, and 1204. RCC.(A)With crushed stone aggregate I.I RCC M 20,(ii) Nominal mix(1:2:4) hand mixing.
Back filling
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.46 MB
Tendernotice_2.pdf
PDF • 8.98 MB
Tendernotice_3.pdf
PDF • 0.55 MB
BOQ_79683.xls
BOQ • 0.30 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .