| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹31.5 LAccepted-AOC 59 NEW MARKET CLOCK TOWER DEHRADUN UK PIN 248001 | DEHRADUN | UTTARAKHAND | 248001 | L1 | Accepted-AOC Being lowest bidder | |
| 2 | L2₹31.8 L+₹31,890 (1.01%)Rejected-AOC 852 EKTA VIHAR 1 C NEAR ANAND NAGAR 9 B PATIALA 147001 | PATIALA | PATIALA | PUNJAB | 147001 | L2 | Rejected-AOC Being other than lowest bidder | |
| 3 | L3₹32.8 L+₹1.3 L (4.07%)Rejected-AOC 32 FATEH ENCLAVE OFFICERS ENCLAVE PHASE II PATIALA 147001 PB | PATIALA | PATIALA | PUNJAB | 147001 | L3 | Rejected-AOC Being other than lowest bidder | |
| 4 | L4₹33.9 L+₹2.4 L (7.74%)Rejected-AOC 300 PREM BASTI 10 SANGRUR SANGRUR PUNJAB 148001 | SANGRUR | PUNJAB | 148001 | L4 | Rejected-AOC Being other than lowest bidder | |
| 5 | L5₹34.7 L+₹3.2 L (10.1%)Rejected-AOC H NO 597 SEONA ROAD RANJIT NAGAR PATIALA PB 147001 | PATIALA | PATIALA | PUNJAB | 147001 | L5 | Rejected-AOC Being other than lowest bidder |
| Sl No | Description | Qty | Unit | Arneja Builders L2 | SWAMI ENGINEERS L3 | M/s badrinath Traders L1 | Jawandha Enterprises L5 | AGGARWAL & CO L4 | PAUL REFRIGERATION L6 |
|---|---|---|---|---|---|---|---|---|---|
| 1.00'Notes: (i) Please refer Schedule 'A' Notes of tender documents. | |||||||||
| 2.00 | Supply and installation of Air conditioners of split units indoor/outdoor complete with cordless remote control unit and with in built air ioniser and plasma filter for better indoor air quality with minimum 3 Star rating as per and EER 3.2, electric driven single phase of capacity of 2.0 TR ( Hot and Cold Type ) complete all as specified and directed. | 10 | Each | 55,000 ₹5,50,000 | 65,000 ₹6,50,000 | 52,000 ₹5,20,000 Lowest | 60,000 ₹6,00,000 | 61,000 ₹6,10,000 | 54,000 ₹5,40,000 |
| 3.00 | Supply and fix voltage stabilizer of capacity 4 KVA electric driven single phase of range 130 to 290 Volts complete all as specified and directed. | 10 | Each | 3,500 ₹35,000 | 5,000 ₹50,000 | 3,500 ₹35,000 | 3,500 ₹35,000 | 2,500 ₹25,000 Lowest | 4,800 ₹48,000 |
| 4.00 | M&L in replacement of existing unserviceable earthing complete with galvanized steel earth plate electrode 600x600x6mm thick buried directly in ground(earth plate not less than 2.25 mtr deep below the normal ground level) with top edge of plate not less than 1. 5 mtr below the normal ground level connected to galvanized earth wire 4mm dia by means of nuts bolts,washers,check nuts of iron or steel including test point PCC pits and RCC cover in PCC 1:2:4 (type B-1) including iron angle frme 40x40x6mm and medium grade GI watering pipe 20mm dia with funnel and wire mesh and 15 mm bore GI pipe light grade proection pipe including excavation and charcoal common salt surrounded with 15cm all around the plate all as Specified and shown in EP-3 of SSR Part-l., complete all as specified and directed. | 2 | Each | 4,000 ₹8,000 | 4,500 ₹9,000 | 5,000 ₹10,000 | 4,500 ₹9,000 | 2,800 ₹5,600 Lowest | 4,200 ₹8,400 |
| 5.00 | Supply and lay in repalacement of exisiting unserviceable XLPE insulated , armoured heavy duty electric cable with aluminium conductor , 1100 volt grade of crosssectional area 50 sqmm 3.5 core all as specified & directed. | 85 | Running Metre | 400 ₹34,000 | 500 ₹42,500 | 350 ₹29,750 | 285 ₹24,225 Lowest | 295 ₹25,075 | 450 ₹38,250 |
| 6.00 | Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m in depth for laying of Pipes, cables, poles,Stay and strips etc and getting out in Soft/Loose soil complete all as specified and directed. | 15 | Cubic Metre | 150 ₹2,250 | 80 ₹1,200 | 150 ₹2,250 | 150 ₹2,250 | 70 ₹1,050 Lowest | 110 ₹1,650 |
| 7.00 | Returning, filling-in including spreading, levelling, watering and well ramming in layers not exceeding 25 cm in soft/loose soil complete all as specified and directed. | 9 | Cubic Metre | 80 ₹720 | 20 ₹180 Lowest | 50 ₹450 | 25 ₹225 | 20 ₹180 Lowest | 40 ₹360 |
| 8.00 | Removing excavated material not exceeding 50m and depositing where directed at a level of not exceeding 1.5m above the starting point, complete all as specified and directed. | 6 | Cubic Metre | 70 ₹420 | 20 ₹120 Lowest | 50 ₹300 | 25 ₹150 | 20 ₹120 Lowest | 60 ₹360 |
| 9.00 | Material and labour for old size brick well burnt, laid flat, for cable protection complete all as specified and directed. | 500 | Each | 5 ₹2,500 | 5 ₹2,500 | 4 ₹2,000 | 4 ₹2,000 | 3 ₹1,500 Lowest | 5 ₹2,500 |
| 10.00 | M&L for Sand cushioning for cables 8 cm below the cable and 15 cm above the cable all as specified and directed . (Punned Sand will be measured for releasing payment) | 5 | Cubic Metre | 300 ₹1,500 | 500 ₹2,500 | 350 ₹1,750 | 250 ₹1,250 Lowest | 250 ₹1,250 Lowest | 540 ₹2,700 |
Tender Value
Refer Docs
EMD Value
₹69,000
Closing Date
15 Aug 2025, 6:00 pmClosed
Garrison Engineer (South) Patiala
MILITARY ENGINEER SERVICES GARRISON ENGINEER SOUTH SANGRUR ROAD PATIALA CANTT
As per tender documents
2025_MES_721363_1
GE(S)/PAT/T-44/2025-26
Open Tender
Civil Works
Item Rate
120 days
Patiala
Refer tender documents
8 documents required · 8 mandatory
₹500
Yes
GE (South) Patiala
₹69,000
Yes
22 Sept 2025
18 Jul 2025
18 Aug 2025
18 Jul 2025
15 Aug 2025
1 Aug 2025
18 Jul 2025 - 25 Jul 2025
Amount
'Notes: (i) Please refer Schedule 'A' Notes of tender documents.
Supply and installation of Air conditioners of split units indoor/outdoor complete with cordless remote control unit and with in built air ioniser and plasma filter for better indoor air quality with minimum 3 Star rating as per and EER 3.2, electric driven single phase of capacity of 2.0 TR ( Hot and Cold Type ) complete all as specified and directed.
Supply and fix voltage stabilizer of capacity 4 KVA electric driven single phase of range 130 to 290 Volts complete all as specified and directed.
M&L in replacement of existing unserviceable earthing complete with galvanized steel earth plate electrode 600x600x6mm thick buried directly in ground(earth plate not less than 2.25 mtr deep below the normal ground level) with top edge of plate not less than 1. 5 mtr below the normal ground level connected to galvanized earth wire 4mm dia by means of nuts bolts,washers,check nuts of iron or steel including test point PCC pits and RCC cover in PCC 1:2:4 (type B-1) including iron angle frme 40x40x6mm and medium grade GI watering pipe 20mm dia with funnel and wire mesh and 15 mm bore GI pipe light grade proection pipe including excavation and charcoal common salt surrounded with 15cm all around the plate all as Specified and shown in EP-3 of SSR Part-l., complete all as specified and directed.
Supply and lay in repalacement of exisiting unserviceable XLPE insulated , armoured heavy duty electric cable with aluminium conductor , 1100 volt grade of crosssectional area 50 sqmm 3.5 core all as specified & directed.
Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m in depth for laying of Pipes, cables, poles,Stay and strips etc and getting out in Soft/Loose soil complete all as specified and directed.
Returning, filling-in including spreading, levelling, watering and well ramming in layers not exceeding 25 cm in soft/loose soil complete all as specified and directed.
Removing excavated material not exceeding 50m and depositing where directed at a level of not exceeding 1.5m above the starting point, complete all as specified and directed.
Material and labour for old size brick well burnt, laid flat, for cable protection complete all as specified and directed.
M&L for Sand cushioning for cables 8 cm below the cable and 15 cm above the cable all as specified and directed . (Punned Sand will be measured for releasing payment)
Material and labour for replacement of GI tubing light grade 40 mm bore for passing through cables under the floor ,along the wall or along the pole complete all as specified and directed.
Supply and fixing 1100 volts grade heavy duty cable PVC insulated stranded aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections, one twin core cable flat or circular stranded conductor size of 10 Sqmm, 2 core passing through PVC conduit complete all as specified and directed.
Supply and installation of Refrigerator, electric driven (Single phase),capacity upto 310 Ltrs Frost Free , 5 star Rating double door type complete all as specified and directed.
Supply and installation of Refrigerator, electric driven (Single phase),capacity upto 360 Ltrs Frost Free , 5 star Rating double door type complete all as specified and directed.
Supply and installation of Deep Freezer Single Phase 240 volt, 50 Hz , glass top 400 Litre capacity having single door Robust Construction, Corrosion resistant Pre coated GI Cabinet. Lockable Lid, Refrigerent R-134 complete all as specified and directed.
Supply and installation , commissioning of water cooler fully stainless steel , electric driven single phase having approx storage capacity of 150 ltrs & nominal cooling capacity of 120 Ltrs per hour complete all as specified and directed.
Supply and installation , commissioning of water cooler fully stainless steel , electric driven single phase having approx storage capacity of 80 ltrs & nominal cooling capacity of 40 Ltrs per hour complete all as specified and directed.
Supply and installation of Air conditioners of split units indoor/outdoor complete with cordless remote control unit and with in built air ioniser and plasma filter for better indoor air quality with minimum 3 Star rating as per and EER 3.2, electric driven single phase of capacity of 2.0 TR ( Hot and Cold Type ) complete all as specified and directed.
Supply and fix Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 3.0 KVA complete all as specified and directed.
Supply and fix Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 5 KVA complete all as specified and directed.
M&L for sub main surface wiring with 2 runs of PVC insulated unsheathed copper conductor cable of size 6 Sqmm single core through existing concealed rigid non metallic PVC conduit of suitable size (Not less than 25 mm dia) in wall and surface of ceiling including 6 Sqmm PVC insulated unsheathed copper conductor cable for continuous earthing form main earth dolly including making good the disturbed potion of wall complete all as specified and directed. (Note :- Two run of 6 Sqmm copper cable one run of 6 Sqmm copper cable and PVC conduit will be measured as a single length).
M&L for single pole neutral encloser with a two pin and earth plug and socket complete with one double pole MCB 20 Amp complete all as specified and directed.
M&L for point wiring with FRLS PVC insulated unsheathed multi-stranded copper conductor 2.5 Sq.mm (nominal area ) single core cable 1100 Volt grade drawn in and including rigid non metallic concealed PVC Conduit on wall , surface of ceiling with all fittings, such as tee, bend, elbow, socket etc including pressed steel sunken boxes (Terminal boxes) with earth dolly,duly galvanised, with white shade frame & cover plate of suitable module for modular switch / or sockets including FRLS PVC insulated unsheathed stranded copper conductor 2.5 Sq.mm (nominal area ) single core cable as earth continuity conducter to common earth and connected to earth dolly, complete all as specified and directed.
M&L for modular plug & play all-in-one PVC box encloser with protected socket 16A incl MCB SPN 20A for protection device complete all as specified and directed.
Supply and installation , commissioning of water cooler fully stainless steel , electric driven single phase having approx storage capacity of 120 ltrs & nominal cooling capacity of 60 Ltrs per hour complete all as specified and directed.
Supply and installation of Deep Freezer Single Phase 240 volt, 50 Hz , glass top 320 Litre capacity having single door Robust Construction, Corrosion resistant Pre coated GI Cabinet. Lockable Lid, Refrigerent R-134 complete all as specified and directed.
Supply and installation of Desert cooler steel body(sheet thickness not less than 16 gauge) electric driven,single phase.The cooler complete with fan of dia 18 inch with motor(GE/CG/Almonard make) 1440 rpm single phase with speed control with three position( low /medium/high)motor. And fitted with water proof cooler pump of sufficient pumping height and delivery to keep the filter in moist condition . The cooler shall complete with filter pads fitted with non decaying filter material .The cooler shall be capable for cooling not less than 2250 cubic feet. The cooler shall have nominal air flow capacity of not less than 6000 Cum per hour.The overall dimension of the cooler shall not be less than 600mm width(measured along discharged grill side),900mm height and 600mm in depth. The cooler tank capacity shall be 60 ltrs. The cooler shall be internally prewired and including back filling arrangement and with connecting cord 3x2.5 sqmm copper flexible cable of 2.5 mtrs length fitted with 3 pin moulded plug top(ISI marked) of 5/6Amp complete all as specified and as directed.
Arneja Builders (BID ID -3385333)
SWAMI ENGINEERS (BID ID -3388748)
AGGARWAL & CO (BID ID -3387120)
Jawandha Enterprises (BID ID -3395263)
PAUL REFRIGERATION (BID ID -3387482)
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .