District Engineer
Jhargram Zilla Parishad
Construction of Primary Health Centre (PHC) Under XV-FC HG During the Year 2024-25 at Laghata, Binpur-I Block under Jhargram District (3rd Call)
2025_ZPHD_955969_1
JGM/ZP/N-61/2025-26
Open Tender
CIVIL AND ELECTRICAL WORKS
Percentage
270 days
Jhargram Zilla Parishad
Please refer Tender documents.
3 documents required · 3 mandatory
₹0
₹2.8 L
Jhargram Zilla Parishad
6 Mar 2026
21 Nov 2025
22 Dec 2025
22 Nov 2025
18 Dec 2025
24 Nov 2025
26 Nov 2025
Dismantling all types of plain cement concrete works, stacking serviceable materials at site and removing rubbish as directed within a lead of 75 m. a) In ground floor including roof. (a) upto 150 mm. thick
Earth work in excavation of foundation trenches or drains, in all sorts of soil (including mixed soil but excluding laterite or sandstone) including removing, spreading or stacking the spoils within a lead of 75 m. as directed. The item includes necessary trimming the sides of trenches, levelling, dressing and ramming the bottom, bailing out water as required complete. a) Depth of excavation not exceeding 1,500 mm.
(b)Depth of excavation for additional depth beyond 1,500 mm. And upto 3,000mm. but not requiring shoring.
Earth work in filling in foundation trenches or plinth with good earth, in layers not exceeding 150 mm. including watering and ramming etc. layer by layer complete. (Payment to be made on the basis of measurement of finished quantity of work a) With earth obtained from excavation of foundation.
A) Filling in foundation or plinth by silver sand in layers not exceeding 150 mm as directed and consolidating the same by thorough saturation with water, ramming complete including the cost of supply of sand. (payment to be made on measurement of finished quantity)
Pre-Constructional Anti-termite measures: c) Anti termite treatment to the top surface of the consolidated earth within plinth walls with chemical emulsion by admixing chloropyrofos emulsifiable concentrates (1% concentration) with water by weight at the rate of 5 Litres per sq. m. of the surface before sand bed or sub-grade is laid. Holes upto 50 mm. to 75 mm. deep at 150 mm. centre to centre both ways shall be made with 12 mm, diameter mild steel rod on the surface to facilitate saturation of the soil with the chemical emulsion. The work shall be carried out as per specification described in para 6.4 of code IS- 6313 (part -II) 1981. ( Mode of measurment will be per Sq.m of plan area of plinth treated.)
d) Treatment to the back filling of R.C.C. foundation with chemical emulsion by admixing chloropyrofos emulsifiable concentrate (1% concentration) with water by weight at the rate of 7.5 ltr. per sq.m. of the vertical surface of the substructure of each side of the foundation. The work shall be carried out as per specification as described in para 6.3.1 of code IS- 6313 (part-II) 1981 (Mode of measurement will be per sq.m. of vertical area of foundation treated).
25mm. thick damp proof course with cement concrete with stone chips (1:1.5:3) [with graded stone aggregate 10 mm nominal size] and admixture of water proofing compound as per manufacturer's specification followed by two coat of polymer based paint, (1st coat after 4 to 5 days of concrete laying and 2 nd coat just before brick masonry work) as directed (cost of water proofing compound & polymer based paint to be paid separately).( Chequering not required over concrete or painted surface). [Note: - Waterproofing as per item 9, polymer based paint as per item 8 (a) of subhead C of Section (C).
Single brick flat soling of picked jhama bricks including ramming and dressing bed to proper level and filling joints with powdered earth or local sand.
Cement concrete (1:3:6 proportion) with graded stone ballast (40 mm. size) excluding shuttering. a) [Pakur Variety] i) In Ground floor
Ordinary Cement concrete (mix 1:2:4) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement,if any, in ground floor as per relevant IS codes. a) Pakur Variety
18 mm. to 22 mm. thick, kota stone slab set in 20 mm thick (avg) cement mortar (1:4) in floor, stair & lobby including pointing in cement slurry with admixture of pigment matching the stone shade, including grinding & polishing as per direction of Engineer - in - charge to match with the existing work. [Slurry for bedding @ 4.4 kg/Sq.m and pointing @2.0kg/Sq.m] Ground floor
S&P Supplying, fitting and fixing PVC pipes of approved make of Schedule 80(medium duty) conforming to ASTMD - 1785 and threaded to match with GI Pipes as per IS : 1239 (Part - I). with all necessary accessories, specials viz. socket, bend, tee, union, cross, elbo, nipple, longscrew,reducing socket, reducing tee, short piece etc. fitted with holder bats clamps, including cutting pipes, making threads,fitting, fixing etc.complete in all respect including cost of all necessary fittings as required,jointing materials and two coats of painting with approved paint in any position above ground. (Payment will be made on the centre line measurements of total pipe line including all specials. No separate payment will be made for accesories, specials. Payment for painting will be made seperately (b) For Exposed Work PVC Pipes 32mm
Ordinary Cement concrete (mix 1:1.5:3) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement if any, in ground floor as per relevant IS codes a) M-20 grade with Pakur variety i) In ground floor and foundation.
Reinforcement for reinforced concrete work in all sorts of structures including distribution bars, stirrups, binders etc initial straightening and removal of loose rust (if necessary), cutting to requisite length, hooking and bending to correct shape, placing in proper position and binding with 16 gauge black annealed wire at every intersection, complete as per drawing and direction. i) In foundation & ground floor
ii) In first floor
Hire and labour charges for shuttering with centreing and necessary staging upto 4 m. using approved stout props and thick hard wood planks of approved thickness with required bracing for concrete slabs, beams, columns, lintels curved or straight including fitting, fixing and striking out after completion of works. (c) Steel shuttering or 9 to 12 mm thick approved quality ply board shuttering in any concrete work i) In foundation & ground floor
ii) In 1st floor
Packing annular space between the outside of the housing pipe and the bore with puddled clay balls of approved size as per direction of the Engineer-in-charge with cost of all materials and labour complete.Deduction
Brick work with 1st class Bricks with cement morter (1:6) (a) In foundation and plinth
(b) In superstructure, ground floor
(c) In 1st floor
125 mm. thick brick work with 1st class bricks in cement mortar (4:1) i) In ground floor
ii) In 1st floor
Controlled Cement concrete with well graded stone chips (20 mm nominal size) excluding shuttering and reinforcement with complete design of concrete as per IS : 456 and relevant special publications, submission of job mix formula after preliminary mix design after testing of concrete cubes as per direction of Engineer-in charge. Consumption of cement will not be less than 300 Kg of cement with Super plasticiser per cubic meter of controlled concrete but actual consumption will be determined on the basis of preliminary test and job mix foumula. In ground floor and foundation.[using concrete mixture] M 25 Grade (i) Pakur Variety i) In ground floor and foundation.
Labour for Chipping of concrete surface before taking up Plastering work.
ii) In first floor
b) 15 mm. thick plaster (6:1) i) In ground floor
ii) In first floor
c) 10 mm. thick plaster (4:1) i) In ground floor
ii) In first floor
Neat cement punning about 1.5mm thick in wall, dado, window sill, floor etc. NOTE:Cement 0.152 cu.m per100 sq.m.
Artificial stone in floor, dado, staircase etc with cement concrete (1:2:4) with stone chips, laid in panels as directed with topping made with ordinary or white cement (as necessary) and marble dust in proportion (1:2) including smooth finishing and rounding off corners including raking out joints or roughening of concrete surface and application of cement slurry before flooring works using cement @ 1.75kg/sq.m all complete including all materials and labour.In ground floor. 3 mm. thick topping (High polishing grinding on this item is not permitted with ordinary cement).Using grey cement (ii) 25 mm. thick i) In ground floor
M 25 Grade ii) In first floor
Extra cost of labour over grey artificial stone for (i) Chequering
(a) Applying 2 coats of bonding agent with synthetic multi functional rubber emulsion having adhesive and water proofing properties by mixing with water in proportion (1 bonding agent : 4 water : 6 cement) as per Manufacturer's specification [Cement to be supplied by the Department].
Supplying and laying true to line and level vitrified tiles of approved brand (size not less than 600 mm X 600 mm X 10 mm thick) in floor, skirting etc. set in 20 mm sand cement mortar (1:4) and 2 mm thick cement slurry back side of tiles using cement @ 2.91Kg./Sqm or using polymerised adhesive(6 mm thick layer applied directly over finished artificial stone floor/Mosaic etc without any backing course) laid after application slurry using 1.75 Kg of cement per Sqm below mortar only, joints grouted with admixture of white cement and colouring pigment to match with colour of tiles / epoxy grout materials of approved make as directed and removal of wax coating of top surface of tiles with warm water and polishing the tiles using soft and dry cloth upto mirror finish complete including the cost of materials, labour and all other incidental charges complete true to the manufacturer's specification and direction of Engineer-in-Charge. (White cement, synthetic adhesive and grout material to be supplied by the contrr] (I) With application slurry @1.75 kg/ Sq.m, 20 mm sand cement mortar (1:4) & 2 mm thick cement slurry at back side of tiles, 0.2 kg/ Sq.m white cement for joint filling with pigment. (B) Light Colour Ground floor
First floor
Hire and labour charges for shuttering with centreing and necessary staging upto 4 m. using approved stout props and thick hard wood planks of approved thickness with required bracing for concrete slabs, beams, columns, lintels curved or straight including fitting, fixing and striking out after completion of (a) 25 mm to 30 mm thick wooden shuttering as per decision & direction of Engineer-In-Charge. i) In foundation & ground floor
(B) Wall With Sand Cement Mortar (1:3) 15 mm thick & 2 mm thick cement slurry at back side of tiles using cement @ 2.91Kg/Sq.m & joint filling using white cement slurry @ 0.20kg/Sq.m.(a) Area of each tile upto 0.09 Sq.m (ii) Coloured decorative Ground floor
Rendering the surface of walls and ceiling with white cement based wall putty (thickness not less than 1.5 mm.) interior surface
Acrylic Distemper to interior wall, ceiling with a coat of solvent based interior grade acrylic primer (as per manufacturer's specification) including cleaning and smoothning of surface.a) Two coats
(a) 75 mm. thick brick work with 1st class bricks set in cement, sand mortar (1:4) in ground floor including H.B. netting in every alternate layers. ii) In Ground floor
ii) In first floor
Protective and Decorative Acrylic exterior emulsion paint of approved quality, as per manufacturer's specification and as per direction of EIC to be applied over acrylic primer as required. The rate includes cost of material, labour, scaffolding and all incidental charges but excluding the cost of primer.Two coats c) Super Protective 100% Acrylic Emulsion.i) In ground floor
ii) In first floor
Supplying, fitting and fixing fibre reinforced polymer (FRP) Composite door frame as per approved section with glass fibre reinforced plastic moulded skins and a special sandwich core, so as to impart monolitaheic composite structure as per approved technology of Department of Science and Technology (DST) to safisfy IS: 4020 door testing performance criteria (i) 66mm x 90mm
Supplying, fitting & fixing fibre reinforced polymer (FRP) Composite door shutters as per approved design with glass fibre reinforced plastic moulded skins and a special sandwich core, so as to impart monolitaheic composite structure as per approved technology of Department of Science and Technology (DST) to satisfy IS:4020 door testing performance criteria. (ii) 25 mm thick i) In ground floor
Collapsible gate with 40mm x 40mm x 6mm Tee as top and bottom guide rail, 20mm x 10mm x 2mm vertical channels 100mm apart in fully stretched position 20mm x 5mm M.S. flats as collapsible bracings properly rivetted and washered including 38mm steel rollers including locking arrangements, fitted and fixed in position with lugs set in cement concrete and including cutting necessary holes, chasing etc. in walls, floors etc. and making good damages complete.i) In ground floor
iii) In first floor
(a) M.S.or W.I. Ornamental grill of approved design joints continuously welded with M.S, W.I. Flats and bars of windows, railing etc. fitted and fixed with necessary screws and lugs .(i) Grill weighing above 10 Kg./sq.mtr and up to 16 Kg./sq. mtr. i) In ground floor
Supplying, fitting & fixing 1st quality Ceramic tiles in walls and floors to match with the existing work & 4 nos. of key stones (10mm) fixed with araldite at the back of each tile & finishing the joints with white cement mixed with colouring oxide if required to match the colour of tiles including roughening of concrete surface, if necessary or by synthetic adhesive & grout materials etc.(A) FloorWith Sand Cement Mortar (1:4) 20 mm thick & 2 mm thick cement slurry at back side of tiles using cement @ 2.91 Kg/Sq.m & joint filling using white cement slurry @0.20kg /Sq.m.(a) Area of each tile upto 0.09 Sq.m (ii) Coloured decorative Ground floor
Supplying, fitting and fixing Stainless Steel railing consist of 38mm dia and 900mm height vertical balustrade at every two alternative steps, 50mm dia top rail, 3 (three) nos 19mm dia horizontal Strainless steel pipe and base/cover plate with Strainless Steel GRADE 304 containing 7.5% nickle (Interior Grade) Brushed/Mat finish, complete as per direction of the Engineer-in-charge. Weight of Strainless Steel railing per metre 6.5 Kg (approx)
Priming one coat on steel or other metal surface with synthetic enamel/ oil bound primer of approved quality including smooth ening surfaces by sand papering etc.
Applying Exterior grade Acrylic primer of approved quality and b
Painting with best quality synthetic enamel paint of approved make and brand including smoothening surface by sand papering etc. including using of approved putty etc. on the surface, if necessary with super gloss (hi-gloss) -b) On steel or other metal surface :iv) Two coats (with any shade except white)
rand on plastered or concrete surface old or new surface to receive decorative textured( matt finish) or smooth finish acrylic exterior emulsion paint including scraping and preparing the surface throughly, complete as per manufacturer's specification and as per direction of the EIC. b)one coats i) In ground floor
Supplying,fitting & fixing of 2-Track / 3-Track Aluminium sliding Window of all Aluminium sections viz. window frame (top,bottom & side frame), shutter (top, bottom, side & interlock member) made of aluminium alloy extrusions conforming to IS 733-1983 & IS 1285-1975, annodised conforming to IS 1868-1983, fitted with all other accessories viz. PVC roller, EPDM gasket, maruti lock, screws etc. including labour charges for fixing of glass (excluding cost of glass) all complete as per architectural fitting & fixing of aluminium 2-track/3-track sliding window with drawings and direction of Engineer-in-charge.10-12 Micron thickness Annodizing film i) Natural White a) 2-track sliding window + b) 3-track sliding window
Supplying, fitting & fixing of partly glazed partly panelled or fully glazed single leaf Aluminium swing door of all aluminium sections viz door frame ( top and side frame), shutter( top rail, bottom rail, lock rail, door vertical),glazing clip made of Aluminium Alloy Extrusions conforming to IS: 733-1983 and IS: 1285-1975, annodized conforming to IS:1868-1983, fitted with all other accessories viz. EPDM gusket,cleat, angle screws etc. including labour charges for fitting and fixing of aluminium door with door spring,/aluminium hinges, glass / Panel board all complete as per architectural drawings and direction of Engineer-incharge. ( Excluding cost of glass/ panel board, door spring/ Al hinges, door closer, door stoper, handle, tower bolt and locking arrangment etc) 10-12 Micron thickness Annodizing film Natural white
Supplying profiles of required section made of Aluminium Alloy Extrusions conforming to IS: 732-1983 and IS: 1285- 1975; Annodized (with required film thickness and specified colour / natural) matt finished conforming to IS: 1868-1983 for fabrication of composit door, sliding & casement windows, partitions, formed of basic sections of any ISI embossed / certified make and brand as per direction of Engineer - In-Charge. (Payment will be made on finished length of the work).i) Top, bottom and side member
ii) Louvered Section
iii) Cleat angle ( Non-annodized)
g) Fixed glazing i) Top, bottom and side member.
ii) Mullion.
iii) Glazing clip.
Anodised aluminium butt hinges of approved quality manufactured from extruded section conforming to I.S. specification (I.S. 205/66) and fitted and fixed with cadmium plated screws: (vii) 100x75x4.00 mm
Supplying 4 lever mortice lock of any approved make and brand as per direction of the Engineer-in-Charge. (a) 100 mm
Labour charges for fabrication and installation of composite door, window, partitions made from annodized extruded alloy aluminium sections for the following units (iv) fixed glazing
(v) Louvered window
Supplying bubble free float glass of approved make and brand conforming to IS: 2835-1987. i) 4mm thick clear glass.
viii) 8mm thick coloured / tinted / smoke glass.
Supplying and affixing optically clear polyester sun control window film having acrylic pressure sensitive adhesive on one side & an acrylic abrasion resistant coating on the other, with composition of infrared absorbing carbon & free from any optical defect. The film characteristics should conform to ASTM E308, ASTM E903, ASTM E84 and ASHIRAE. The film should be pasted after preparatory works without any cracking, delamination, bubbling, discolouring and variation in total transmission of light across the width at any portion along the length doesn't exceed 2% over the average including scaffolding & relevant others to complete in all respect as per manufacturer's specification & direction of Engineer -in-Charge. (Note: This work should not be executed without specific permission of Superintending Engineer)(a) Normal Quality : Film Thickness - 1.0 Mil, Glare Reduction > 45%, U factor < 1.15
Providing, fitting and fixing in position, medium density fibre board conforming to IS: 12406-1988 for plain and IS: 14587-1998 for prelaminated made of wood fibr
Anodised aliminium D-type handle of approved quality manufactured from extruded section conforming to I.S. specification (I.S. 230/72) fitted and fixed complete: (a) With continuous plate base (Hexagonal/ Round rod) (iv) 125 mm grip x 10 mm dia rod.
Supplying, fitting & fixing Stainless Steel 'D' or 'H' type of size 300 mm x 19 mm tubular Handle with Grade 304, CE certified, marked & conforming to EN - 1154, of approved quality of reputed brand as per direction of Eingineer-in- Charge fitted and fixed complete including all incidental charges.
(iv) 150mm long x 10mm dia. bolt.
i) Iron hasp bolt of approved quality fitted and fixed complete (oxidised) with 16mm dia rod with centre bolt and round fitting (b) 250mm long.
Supplying, fitting & fixing UPVC pipes A- Type and fittings conforming to IS:13592-1992 with all necessary clamps nails, including making holes in walls, floor etc. cutting trenches in any soil through masonry concrete structures etc if necessary and mending good damages including joining with jointing materails (Spun Yarn, Valamoid/Bitumen/M-Seal etc) complete.A) UPVC Pipes: (ii) 110 mm. Dia.
a) Plain Tee(ii) 110 mm. Dia.
b) Plain Y(ii) 110 mm. Dia
c) Bend 87.5 degree (ii) 110 mm. Dia.
d) Shoe (ii) 110 mm. Dia.
Providing and fixing exterior quality Aluminium Composite Panel (ACP) wall cladding on existing Al. /MS frame work with GI brackets, ACP fixed on the existing frame work by folding the edges of ACP anel (Engraving the rear surface of ACP sheet) with CP angles, cleats and strainless Steel screws forming groves at the periphery of ACP panel. Such grooves filled with foam and silicon sealant etc. complete with all materials (but including the cost of silicon sealant), labour, scaffolding and all other incidental charges complete in all respect as per specification and direction of Engineer-in-charge. (Mode of payment is on finished surface area of ACP) 3mm thick (0.25mm Al.+2.5mm LDPE +0.25mm Al. PVDF coating
Printing new letter and figures of any shade with synthetic enamel paint black or any other approved colour to give an even shade as per drawings and Technical Specification Clause 801 of Specifications for Road & Bridge Works of MoRT&H (5th Revision).
Supplying, fitting and fixing Black Stone slab used in Kitchen slab, alcove, wardrobe etc. laid and jointed with necessary adhesive Cement mortar (1:2) including grinding or polishing as per direction of Engineer-in -Charge in Ground Floor. (a) Slab Thickness 20 to 25 mm
Supplying,fitting & fixing granite slab 15mm to 18mm thick in floor, lobby, stair, landing and treads etc. over 20mm (avg) thick base of cement morter (1:2) laid with white cement slurry @ 4.40Kg per Square meter before placing of granite and jointed with white cement slurry @ 2.0 Kg per square meter with necessary pigments and complete as per direction of Engineer-in-charge including cost of all materials, labours, curing and roughening of concrete surface complete. In ground floor (c) Area of each Granite slab above 1.00 Square meter.
Supplying, fitting & fixing of Aluminium fixed partion wall of all aluminium sections viz top, bottom and side member, intermediate member, glazing clip made of Aluminium Alloy Extrusions conforming to IS: 733-1983 and IS: 1285-1975, annodized conforming to IS:1868- 1983, fitted with all other accessories viz. EPDM gusket,cleat, angle screws etc. including labour charges for fitting and fixing of aluminium fixed partition wall with glass / panel board all complete as per architectural drawings and direction of Engineer-in-charge. (Excluding cost of glass/ panel board, 10-12 Micron thickness Annodizing film. Natural white. a) for unsupported length of vertical member upto 1.50m. height of both ends of vertical member restrained but panel with in 0.90 sqm (unit wt of Top, bottom & side member @1.366 kg/m ; intermediate member @ 1.443 kg/m; glazing clip: 0.167 kg/m respectively) [Note : for estimate purpose construction wing may consider weight of Al-Sections for Partition wall @ 5.7 Kg per Sq.M]
b) For unsupported length of vertical member above 1.50m. height of both ends of vertical member restrained but panel above 0.90 sqm (unit wt of Top, bottom & side member @ 1.978; intermediate member @ 2.055; glazing clip @ 0.167 kg/m respectively) [Note : for estimate purpose construction wing may consider weight of Al-Sections for Partition wall @ 5.0 Kg per Sq.M]
M.S. works in framed gratings of window etc.made of round or square bars and frame work or M.S. flats (with the bars securely fixed to the flat bar frame ) with or without intermediate flat bar stiffener and fixed with necessary screws etc. complete , as directed. In ground floor.
ii) Grill weighing above 16 Kg./sq.mtr and above a) In first floor
M.S. structural works in columns, beams etc. with simple rolled structural members (e.g. joists, angle, channel sections conforming to IS: 226, IS: 808 & SP (6)- 1964 connected to one another with bracket, gussets, cleats as per design, direction of Engineer-in- charge complete including cutting to requisite shape and length, fabrication with necessary bolting, metal arc welding conforming to IS: 816- 1969 & IS: 1995 using electrodes of approved make and brand conforming to IS:814- 2004, haulage, hoisting and erection all complete. The rate includes the cost of rolled steel section, consumables such as electrodes, gas and hire charge of all tools and plants and labour required for the work including all incidental chages such as electricity charges, labour insurance charges etc. I) For structural members of specified sections weighing less than 22.5 Kg./m
Estimated Rate in Rs. P
(b) Priming one coat on timber or plastered surface with synthetic oil bound primer of approved quality including smoothening surfaces by sand papering etc.
(a) On timber or plastered surface : With super gloss (hi-gloss) - two coat
Holding down bolt with nut including 100 x 100 x 6 mm plate washer at bottom fitted complete and packing the hole with cement concrete or cement grout as directed. (i) 16 mm dia bolt (a) 300 mm long
(b) For Concealed Work PVC Pipes 15 mm
Supplying fitting and fixing steel rolling grills link type, shutter with 18 B.G .of approved type steel to the section 75mm wide, fitted with coil wire spring to necessiate the fitting of required Nos. of C.I. Pulleys on heavy type solid drawn seamless steel tube complete with locking arrangements both inside and outside specially builtup side guide channels including providing a hood for the steel rolling shutter in the room, painting two coats of approved aluminium paint over a coat of red lead primer complete.
Square or hexagonal mesh netting made with 18 B.W.G. galvanised wire, fitted and fixed complete as per design (excluding the supporting framework but including local sal wood battens of size 37.5mmx25mm). In ground floor. (b)25 mm mesh
viii) 25mm
(vii) 32 mm dia
50 mm dia
Supplying, fitting and fixing bib cock or stop cock. (It-7, P-6) (b)iii) Chromium plated Concealed Stop Cock (Equivalent to Code No.514(A) & Model - Tropical / Sumthing Special of ESSCO or similar brand).
supplying ,fitting and fixing peets valve fullway gunmetal standard pattern best quality of approved brand bearing isi markings with fittings (tested to 21 kg per sq.cm) (ix)15 mm dia
(e) PTMT (Polytetra Bib Cock / Stop Cock ( Prayag or equivalent) 15 mm (Stop Cock) (i) for Basin
(ii) for Toilet main line
Supplying P.V.C water storage tank of approved quality with closed top with lid(black)-Multilayer. (c) 500 litre capacity
1500 litre capacity
Labour for hoisting plastic water storage tank.
Labour for hoisting plastic water storage tank. (P-37; I-10) (i) upto 1500 litre (a) Upto 1st story from G.L.
Supplying, fitting and fixing pillar cock of approved make. a) (i) CP Pillar Cock - 15 mm. (Equivalent to Code No. 507 & Model - Tropical / Sumthing Special of ESSCO or similar brand).
Labour for punching hole in plastic water storage tank up to 50 mm dia.
Supplying, fitting and fixing white vitreous china best quality approved make wash basin with C.I. brackets on 75 mm X 75 mm wooden blocks, C.P. waste fittings of 32 mm dia., one approved quality brass C.P. pillar cock of 15 mm dia., C.P. chain with rubber plug of 30 mm dia., approved quality P.V.C. waste pipe with C.P. nut 32 mm dia., 900 mm long approved quality P.V.C. connection pipe with heavy brass C.P. nut including mending good all damages and painting the brackets with two coats of approved paint.ii) 550 mm X 400 mm size
Supplying, fitting and fixing pillar cock of approved make. b) PTMT Pillar Cock - 15 mm. (Prayag or equivalent). (P-45, I-19) for toilets
f) (i) CP Pillar Cock with 200 mm extended Lever Handle (Equivalent to Code No. 5031 & Model - FLORENTINE of JAQUAR or similar brand). For Laboratory sink
(iv) Angle back wash basin 400 mm X 400 mm
Supplying,fitting and fixing approved brand P.V.C. CONNECTOR white flexible, with both ends coupling with heavy brass C.P.nut,15 mm dia. i) 450mm long
Suppling fitting & fixing c.i round grating i)100mm (P-67; I-18)
Supplying, fitting & fixing approved patent vent cowl I.C.I. conforming to I.S.S and painting two coats to the exposed surface with approved paint complete. (Payment of Painting will however be paid seperately). (i) 75 mm dia. (P-64, I-9)
Suppling fitting & fixing approved brand 32mm dia p.v.c waste pipe with p.v.c coupling at one end fitted with necessary clamps i)900mm long
Supply of UPVC pipes (B type )& fitting conforming to IS 13592-1992 A) i) single socketed 3 Mtr. length --b)110 mm
(ii) Labour for fitting and fixing U.P.V.C. pipes for above ground work including cost of jointing materials etc. fitting and fixing all necessary cutting pipes, cutting holes in walls or R.C. floor where necessary and mending good all damages excluding the cost of masonry or concrete work, if necessary, but including the cost and fitting and fixing holder bat clamps (any floor) or for underground work including cutting trenches upto 1.5 metre and refilling the same complete as per direction of the Engineer-in-charge. (Payment will be made on centre line measurement of the total pipeline including specials.A) Above ground (ii) 110 mm dia.
i)450 mm X 300 mm size
Supplying, fitting and fixing White Vitreous China Sink in position on C.I. brackets including two coats of painting of brackets. (Item- 5.b Page-42) (b) Laboratory sink with rim and overflow (ii) 500 mm X 300 mm X 150 mm
Supplying, fitting and fixing CPVC (Chlorinated Polyvinyl Chloride) pipes of approved make conforming to IS-15778: 2007 . with all necessary accessories, specials viz. socket, bend, tee, union, cross, elbo, nipple,longscrew, reducing socket, reducing tee, short piece etc.fitted with holder bats clamps, including cutting pipes, fitting, fixing etc. complete in all respect including cost of all necessary fittings as required,jointing materials in any position above ground. (Payment will be made on the centre line measurements of total pipe line including all specials. No separate payment will be made for accesories, specials. (Item No 1b(i), P-29) For Concealed Work CPVC Pipes Class-1,SDR-11. a)15mm
Supplying, fitting and fixing shower of approved brand and make. (i) (2) Chromium plated overhead Rain shower (Round), size-200mm dia. with revolving joint (Model Code No. F7010601 of CERA or equivalent) [Item-3 Page-4]
Supply of UPVC pipes (B Type) & fittings conforming to IS-13592-1992 (PAGE NO- 68, ITEM NO- 23) (A) (i) Single Socketed 3 Meter Length (waste pipe) a) 75 mm
(ii) Plain T
(ii) Plain Y
iv) Bend 87.5º
er ground (ii) 110 mm dia.
xv) vent cowl -(b) 110mm
xxxiv) Multi Floor Trap without Top tile & Strainer
xvii) W.C. Connector (150 mm long) 125 X 110(W/WC Ring) 75 mm
Suppling fitting & fixing E.W.C in white glazed vitreous china ware of approved make supplied fittied complete in position with necessary bolts nuts.etc. a)with 'P' trap
Supplying fitting & fixing closet seat of approved make with lid & C.P hinges,rubber beffer & brush screw complete.(a) E.W.C. (ii) Plastic (hallow type) white
Supplying fitting & fixing 32 mm. dia. flush pipe of approved make with necessary fixing materials & clam complete. i)Polythene flush pipe.
xxx) Cleaning Pipe(a) 75 mm
xvi) Pipe Clip (a) 75 mm
(i) Supplying, fitting and fixing liquid soap container c) fibre glass
Supplying fitting & fixing best quality indian make mirror 5.5 mm thk. With silvering as per I.S.I specification supported on fibre glass frame of any colour,frame size 550mm x 400mm
Constructing inspection pit of inside measurement 600mm x600mm x upto 600mm (depth) with 250mm th. 1st. Class brick work in cement mortar(1:4) on all sides bottom of the pit consisting of 100 mm th. Cement concrete (1:3:6) with stone chips over a layer of jhama brick fklat soling, 15 mm thk. (4:1) cement plaster to bottom of the pit providing necessary invert with cement concrete (1:3:6) with stone chips as per direction ,neat cement finishing to entire internal surface top of the pit convered with 100 mmth. R.CC slab (1:1.5:3) with stone chips and necessary reinforcement upto 1% and shuttering including 6mm thk.cement plaster (1:4) in all external surfaces of the slab and one 560 mm dia .R.C.C manhole cover of approved make supplied ,fitted and fixed in the slab with necessary fittings, necessary earthwork in excavation in all sorts of soil, filling sides of the pit with earth removing spoils after work complete in all respect with all costs of labour and materials. i) With pakur variety (SAIL/TATA/RINL)
Supplying fitting & fixing 10 ltr. PVC low down cistern conforming to I.S specification with PVC fittings complete C.I brackets including two coats of painting to bracket etc. (Item- 2 Page-36)
Supplying, fitting and fixing C.P. chain and stay with rubber plug.. (Item-11, Page-43) (ii) 32 mm dia. of plug
Construction of circular soak well 2.5 m deep inall types of sandy soils with dry brick work upto 1:6 m from the bottom having 150mm intermediate cement brick work(1:4) band all round and cement brick work (1:4) upto .90m from top with 20mm thk. Cement plastering (4:1) to inside face upto the depth of cement brick work, 15 mm th.cement plaster (1:4)on outer face from top of the well upto G.L and 6mm thk. cement plaster (1:4) on top of the R.C.C cover slab including filling bottom 1.0m of inside of the well with brick metal (501mm to 63mm size) including R.CCcover slab of designed thk. with cement concrete b(1:1.5:3) with stone chips with necessary. reinforcement and shuttering including one 560 mmdia .R.CC manhole cover(heavy type) of approved make supplied ,fittings making necessary arrangements for pipe connections ,excavation of well including shoring, dewatering and removing the exess earth from the premises as per direction complete in all respect with all costs of labour and materials.a)with 250mm thk.dry brick work and 250 mm thk. cement brick work (6:1) and 1.00 m inside dia. For-SAIL/TATA/RINL
Construction of septic tank of different capacities as per approved drawing with 1st class brick work in cement mortar (1:4) including two 560 mm dia. R.C.C. manhole cover(heavy type)of approved make supplied, fitted and fixed in the 100mm thick R.C.C (1:1.5:3) top slab with necessary fittings, 20mm thick cement plaster (4 : 1) with neat cement finish to the internal surfaces and 15 mm thick cement plaster (4 : 1) to outside wall upto 200 mm below G.L floor finished with 25 mm thick grey artificial stone over 100 mm thick R.C.C.........(ii) For 20 users (A) With Pakur Variety (SAIL/TATA/RINL)
Supplying, fitting & Fixing EWC (Size- 710x370x810 mm)in white glazed vitreous chinaware of approved make supplying, fitting and fixing in position complete with necessary nut and bolts. (Model Code No. S10221114-P Trap (CRUSE SET) of CERA or equivalent.)
Supplying, fitting and fixing 10 litre white glazed vitreous chinaware of approve low-down cistern of approved make with either side or bottom inlet, side overflow, brackets complete with all internal fittings. (Model Code No. S1060106 of CERA or equivalent.)
Soft Close seat cover of approved make with lid and C.P. hinges, rubber buffer and brass screws suppling, fitting and fixing complete. E W C (Model Code No. B1520118 of CERA or equivalent.) White
Supplying, fitting and fixing Stainless steel Wall Mounted Grab Bar. Load bearing capacity 150 kg, covered by Nylon surface with contour finish (for better grip) with Anti-bacterial surface complete. (Model Code No. B2210106 of CERA or equivalent.) 600mm Long
Supplying, fitting and fixing towel rail with two brackets. (a) C.P. over brass 25 mm dia. and 600 mm long (It-22 a(i) P-82) (Nurse, MOIS Room)
Supplying, fitting and fixing Stainless steel Wall Mounted Hinged hand rail (750X100 mm) covered by Nylon surface with contour finish (for bettr grip) with two brackets.(Model Code No.B2210108 of CERA or equivalent.) 750 mm long
Supplying, fitting and fixing 15 mm Twin Flush Fitting (Model Code No. B1810112 of CERA or equivalent).
b) Over burden / from 23 mtr to 70 mtrs and above
Supply of PVC pipes & fittings Schedule 80 (medium duty) conforming to ASTMD - 1785 and threaded to match with GI Pipes as per IS : 1239 (Part - I). PVC Pipes (i) 32 mm
Supply&delivery of 125mm internal diaUPVC casing pipe (minimumwall thickness6.5mm)having3mtr lengtheachboth end threaded and one end socketed as per IS-12818CM/CS (CEPET testmay be performedbefore supply at store as per direction of EIC) (i) 125 mm
Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints or rougening of concrete surface, including throating, nosing and drip course where necessary.a) 20 mm. thick plaster (6:1) i) In ground floor
Supplying high density polythene strainer of approved make with adapter conforming to I.S. specifications. (iii) 80 mm dia.
Packing the annular space between the outside of the tube well pipes & strainers and the bore with pea size washed gravel of approved quality having size from 2 mm to 5 mm or the size approved by the Engineer-in-charge including cost of all materials labour and equipment complete.
Supplying, fitting and fixing steel cutter piece upto 450 mm long with sockets. (iii) 75 mm dia.
Supplying, fitting and fixing plug of approved make conforming to I.S. specifications. (ii) 50 mm dia.
Supplying, fitting and fixing heavy type bell mouth reducing socket.(i) 50 mm X 100 mm
Supplying, fitting and fixing G.I. cap at top (i) 100 mm
Washing and developing tube well with air compressor pump and engine for 8 (eight) hours continuous pumping per day with necessary arrangements for testing the yield in gallons per hour with 'V' notch including hire and labour charges for all tools and plants and scaffolding as required.
Labour for making arrangement for showing verticality test including the cost for hire charges of tools and plants, scafolding, labour etc. all complete
Collecting sample of water for bacteriological and chemical test from any depth at any time during execution of work including hire and labour charges for tools and plants and sterilising the equipments, paying all charges and fees, testing etc. complete in all respect as per direction.
Supplying, fitting and fixing 300 mm M.S. housing clamp of approved quality.
Geophysical investigation of the acquifer by electrologging system with all tools and plants as necessary including supply of necessary report.
Supplying, fitting and fixing gunmetal wheel valve of approved brand and make tested to 21 kg per sq. cm. (for water lines only). (vi) 32 mm dia
Supplying, fitting and fixing chech valve (vertical) G.M. tested to 21 kg per sq. cm. (IV) 32mm
Supply and delivery of clear water vertical wet type submersible pump suitable for bore well conforming to IS: 8034 (and as amended thereafter) with standard MOC for potable clear cold water and BEE 3 Star Rated capable of discharging noted M³/hr against head of water column. The pump shall be directly coupled with a continuous rated 2- pole suitable wet type vertical squirrel cage induction motor conforming to IS: 9283 (and as amended thereafter), suitable for operation in AC Single phases 220 V, 50HZ (category B motor) as per specification and direction of EIC. 1 Ph. 230V, 1.5 HP submersible pump Make - Crompton Greaves/CRI/Siemens stage 25
(i) 25 mm dia. and 450 mm long (Labour Room)
Supply and delivery of direct on line ( DOL) strater panel board confonning to ISl3947 and IEC 947 of suitable HP rating for operation in 230V (+ I }yo) AC , single phase , 50Hzl+5yo) compr
ising of ammeter, voltnreter, thermal overload relay, 2 pole magnetic contactor with in built water Ievel control, under voltage protection, irrdicating lamp. capacitors, on/off push buttons including 5 way connector, wiring with l/1,5 sq. mm PVC insLrlated copper wire. powder coated vermitr proof box of following capacities: 1.5 H.P. (Relay Range 9-14 Amp.)
3C Flat water proof CU.cables lSI marked-IS 694 b) 3C X 2.5 sq. mm
(ii) Next 50 metre
Supplying, fitting and fixing heavy type bell mouth reducing socket. (iv) 100 mm X 200 mm
Supply of PVC pipes & fittings schedule80 (mediumduty) conforming to ASTMD-1785 and threaded to match with GI Pipes as per IS:1239 (Part - I). 100 mm
Supplying PVC strainer of approve dmake with adapter conforming to I.S.12818 specifications. 150 mm
Supplying, filling, spreading & leveling stone boulders of size range 5 cm to 20 cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineerin- charge.
Supplying, filling, spreading & leveling gravels of size range 5 mm to 10 mm, in the recharge pit, over the existing layer of boulders, in required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge.
Supplying, fitting and fixing yard gully with approved H.C.I. grating complete. (P- 68; I-20 (i)) (i) 225 mm X 150 mm with 230 mm gratings
Supplying, filling, spreading & leveling coarse sand of size range 1.5 mm to 2 mm in recharge pit, in required thickness over gravel layer, for all leads & lifts, all complete as per direction of Engineer –in-charge.
Supplying, fitting and fixing in position R.C.C. Manhole/ pit cover of approved make with rim of approved make (Heavy type) (ii) 560 mm dia.
Supply Delivery and installation of ABC Powder type fire extinguishers (stored pressure)D) 06 Kg with ISI marked Mono Ammonium Phosphate base ABC power conforming to IS:14609 and pressurized with nitrogen gas. Suitable for operating between (-)30ºC to (+)55ºC. Fire rating -2A & 21B( E&M page no 24, It. 77D
ii) In first floor
Sinking Tubewell with Installation of Submersible Pump Drilling bore hole in DTH method through any kind of soil sand rock sinoverburdensuitableforloweringandfittingfixingof125 mmdia. casingpipeup toanaveragedepthof 23mtrs. and subsequently115mmdiameterboringthroughanykindofrocky formationuptoatotaldepthof70mtrsincludingallotherworks necessary for boring as per direction of E.I.C This item includes the costofhiringofRigmachine,Compressor,Supportingvehicleand othermachinery&equipmentswithoperators, drivers, laborers etc. Proportionate cost of drilling tools andaccessories suchas Hammer, Bit, etc. Cost of consumablematerials like fuel & lubricants,anyotherrelatedequipment,materialsandserviceetc. as per technical specification a). 0 to 23 mtr (Over burden)
R.C. shelves (1:1.5:3) either precast or cast in situ with stone chips and necessary reinforcement upto 1% (0.8% main and 0.2% distribution bars), shuttering etc. and 10 mm. thick cement plaster (1:4) including neat cement finishing and cutting chase fitting and fixing in position, mending good damages as necessary complete. In ground floor (a) 50 mm. Thick panels I. SAIL/ TATA/RINL
Renewing gully grating. (i) 375 mm X 300 mm X 40 mm X 18 kg (Rate multiply by 100/105 for new work)
Providing weep holes in Brick masonry / Plain / Reinforced concrete abutment, wing wall / return wall with 100 mm dia AC pipe, extending through the full width of the structure with slope of 1V:20H towards drawing face. Complete as per drawing and Technical specifications.
Supplying 1.5mm thick M.S. sheet fitted and fixed on one or both faces of M.S./ W.I. gate etc. with point welding at not more than 150mm apart complete in all respect as per design including cost of all labour and materials.
Supplying and stacking of good earth (adequate for horticulture work) at site including royalty (earth measured in stack will be reduced by 20% for payment)
Supplying and stacking sludge (adequate for Horticulture work) at site in dry cake form from approved disposal work site including royalty, all lead and lift etc. (Sludge measured in stack will be reduced by 8%)
Spreading of sludge, dump manure,/farm yard manure/animel dung manure and good earth in required thickness. This includes supply of labour, tools & plants excluding materials.
Labour for boring through any type of soil for sinking tube well of required dia. with top enlargement by rig boring system (either by reserve circulation or by direct rotary method) including hire charges and labour for rig machine, tools and plants, staging, force umping set and makin arrangement for water required for boring etc. complete and lowering of pipes, strainers, blind pipes etc. complete. (a) 300 mm dia.
Supplying, fitting and fixing PVC pipes for underground work of approved make of Schedule 80 (medium duty) conforming to ASTMD -1785 and threaded to match with GI Pipes as per IS : 1239 (Part - I). with all necessary accessories, specials viz. socket, bend, tee, union, cross, elbo, nipple, longscrew, reducing socket, reducing tee, short piece etc. fitted including cost of all materials ,jointing materials, cutting pipes, making threads ,cutting trenches upto 1.5 metre below surface in all sorts of soil and refilling the same as directed complete in all respect. (Payment will be made on the centre line measurement of the total pipe line including all specials No separate payment will be made for accessories, specials.) PVC Pipes (Dia) 100 mm 80 mm
Applying decorative cement based paint of approved quality after preparing the surface including scraping the same thoroughly (plastered or concrete surface) as per manufacturer's specification. (iii) one coats. New surface, In Ground floor:
Two coat
Supplying and laying true to line and level Tactile Finish Scratch resistant, Neutral to UV rays, Non-fade, High Slip Resistant Full Body Vitrified Tiles conforming to IS:15622-2006 & IS :4457- 2007 and tested in accordance with IS
:13630 [Non- modular sizes for tiles with Skid resistance: 0.6, Mohr's hardness > 7.0, Staining resistance: Class-1, Water Absorption E < 0.5%], MOR > 38N/sq.mm & Breaking strength > 4000 N for Outdoor area of building e. g. Driveway, Pathway, Pavements, Parking lots, Sloping ramps, Entrance lobbies, Patios, Portico, swimming pool enclosure, Bus Passenger Shed & directing visually impaired persons, set over necessary underlay and 2 mm thick cement slurry at back side of tiles using cement @ 2.91 Kg./Sqm, joints grouted with admixture of white cement and colouring pigment to match with colour of tiles and removal of wax coating of top surface of tiles with warm water and cleaning the tiles using soft and dry cloth complete including the cost of materials, labour and all other incidental charges complete including backside slurry but excluding the cost of underlay and true to the manufacturer's specification and direction of Engineer-in-Charge. In Ground Floor: Sizes-300 mm x 300 mm x15 mm
Wood work in door and window frame fitted and fixed in position complete including a protective coat of painting at the contact surface of the frame exluding cost of concrete, Iron Butt Hinges and M.S clamps. (The quantum should be correted upto three decimals). (d) Sal : Local. Ground Floor
Dismantling all types of masonry excepting cement concrete plain or reinforced, stacking serviceable materials at site and removing rubbish as directed within a lead of 75 m. a) In ground floor including roof.
Fixing only single/twin fluorescent light fitting suspended 25 cm bellow the ceiling with 2 No. 20 mm dia EI conduit (14 SWG) supports fixed with “L” type MS clamp whose one side fixed on ceiling with sutable size 4 nos. fastener and other side connected with the conduit with suitable size of bolts and nuts incl. S&F EI conduit, “L” type (125mmx125mm) 6mm thick and 25mm with MS clamps and connecting the length of PVC insulated wire and mending good damages to original finish and painting etc. by 2x24/0.20 mm (1.5sqmm.) flexible copper wire of 1.10 mt. length.
Labour Cess @ 1%
Part-I : CIVIL WORK : Surface Dressing of the ground in any kind of soil including removing vegetation inequalities not exceeding 15 cm depth and disposal of the rubbish within a lead upto 75 m as directed.
Each Test
Distn. wiring in 22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire (Brand approved by EIC) in 19 mm bore, 3 mm thick polythen pipe complete with all accessories embedded in wall to 240 V 5A 3 pin plug point incl. S&F 240 V 5A 3 pin flush type plug socket & piano key type switch (Anchor make) incl. S&F earth continuity wire, fixed on sheet metal (16 SWG) switch board with bakelite/perspex (wall matching colour) top cover (3 mm thick) flushed in wall incl. mending good damages to original finish. 2x22/0.3 (Ph. & N) and 1x22/0.3 as ECC. On Board
Distribution wiring in 1.1 KV grade 2x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC) in suitable size PVC casing-capping (Precision make) with 1x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire for ECC, incl. necy. PVC clips, fittings etc. to light point with 2 no. 2 way piano key type switch fixed on sheet steel fabricated switch board with Perspex/bakelite top cover on wall incl. necy. connections and making earthing attachment and mending good damages to building works [PVC casingcapping on surface and Switch board concealed]. Average run 9 mtr.
Supplying and Drawing 1.1 KV single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire (Brand approved by EIC) of the following sizes in the prelaid polythene pipe and by the prelaid GI fish wire and making necy. connection as required.a) 3 x 22/0.3 (1.5 sqmm)
b) 2x36/0.3 (2.5 sqmm) + 1x22/0.3 (1.5 sqmm) as ECC
c) 2x56/0.3 (4 sqmm) + 1x36/0.3 (2.5 sqmm) as ECC
d) 2x84/0.3 (6 sqmm) + 1x56/0.3 (4 sqmm) as ECC
e) 4x126/0.4 (16 sqmm) + 2x80/0.4 (10 sqmm) as ECC
Supplying and fixing polythene pipe complete with fittings as necy. under ceiling/beam, bound with 22 SWG GI binding wire incl. supplying and drawing 1x18 SWG GI Wire as fish wire inside the pipes and fittings and providing 50 mm dia disc of MS sheet (20 SWG) having colour paint at one face fastened at the load point end of the polythene pipe with fish wire (synchronizing with roof/beam casting work of building construction)a) 19mm dia 3mm thick Polythene Pipe
b) 25mm dia 3mm thick Polythene Pipe
Cutting Channel of size (40 mm x 40 mm) on masonry wall by Electric operated cutting machine incl. supplying & fixing heavy gauge 19 mm, 3 mm thick Polythene pipe by means of anchoring chemical (Hilti/Sika) and GI 'U' hooks of 8 SWG incl. supplying and drawing 18 SWG GI wire as Fish wire and mending good damages to original finish by using own tools and tackles. 19 mm dia 3 mm thick polythene pipe without earth continuity wire.
Cutting Channel of size (43 mm x 43 mm) on masonry wall by Electric operated cutting machine incl. supplying & fixing heavy gauge 25 mm, 3 mm thick Polythene pipe by means of anchoring chemical (Hilti/Sika) and GI 'U' hooks of 8 SWG incl. supplying and drawing 18 SWG GI wire as Fish wire and mending good damages to original finish by using own tools and tackles. 25 mm dia 3 mm thick polythene pipe without earth continuity wire.
Supplying and fixing PVC casing-capping [Precision Make] on wall or ceiling, incl. necy. PVC fittings etc. and mending good damages to building works. 20x10mm Size.
b) 25x10mm Size
Finishing of the PVC insulated wire ends by socketting with pin/ ring type copper sockets and insulated tapes etc., including supplying sockets, tapes.a) 2.5sqmm
b) 4 sqmm
c) 6 sqmm
d) 10sqmm
e) 16sqmm
Supply & Fixing 240 V, 6A, plug socket with separate 6 A Piano key type switch (Brand approved by EIC) on sheet metal switch board embedded in wall incl. S & F 150x100x65mm MS (16SWG) switch board and bakelite/perspex top cover of 3mm thick by Brass screws after making housing for switch by cutting bakelite/perspex cover and making necessary connections as required.
Supply & Fixing 240 V, 20A, plug socket with separate 20 A Piano key type switch (Brand approved by EIC) on sheet metal switch board embedded in wall incl. S & F 150x100x65mm MS (16SWG) switch board and bakelite/perspex top cover of 3mm thick by Brass screws after making housing for switch by cutting bakelite/perspex cover and making necessary connections as required
Supply & Fixing 240 V, 4 nos. 6A, plug socket with separate 4 nos. 6 A Piano key type switch, indicator & 16A switch type SP MCB (Brand approved by EIC) on sheet metal switch board embedded in wall incl. S & F 240x200x65mm MS (16SWG) switch board and bakelite/perspex top cover of 3mm thick by Brass screws after making housing for switch by cutting bakelite/perspex cover and making necessary connections as required
Supply & Fixing 240 V, 2 nos. 6A, & 2 nos. 20A plug socket with separate 2 nos. 6 A & 2 nos. 20A Piano key type switch, indicator & 20A switch type SP MCB (Brand approved by EIC) on sheet metal switch board embedded in wall incl. S & F 240x200x65mm MS (16SWG) switch board and bakelite/perspex top cover of 3mm thick by Brass screws after making housing for switch by cutting bakelite/perspex c
over and making necessary connections as required
Supply & Fixing 240 V, 25A Modular type socket, 25 A, Modular type starter (Brand approved by EIC) with 25A Modular switch type DP MCB (C-Curve) and 6 Module GI Modular type switch board with 6 Module top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc.
Supplying & Fixing Industrial Plug & Socket board with 240 V, 20A, SPN & Earth Metal Industrial Plug socket & 20A Industrial top incl. S&F 20 A SP MCB breaking capcity 10kA (C- Curve) in SS enclosure fixed on wall and cecessary conection. (UPS Board)
Supply & Fixing 240 V,25 A, 3 pin Modular type plug top with indicator (Brand approved by EIC) & necy. Connections.
Main LT Panel:- Supply, delivery, installation, testing & commissioning of Indoor Cubical type L.T. Distribution panel board of required size, wall/stand mounted compartmentalized with maple arrangement having rigid & self supporting structure with cable alley fabricated from 2 mm thick CRCA sheet steel and 35x35x5 mm M.S. angle frame for panel mounting support and making necessary grouting arrangements with neet cementing finish as per direction of EIC. (Dim. 1600mm x 1450mm x 350mm].
Supply of 2 mm thick wooden ply board of size 3 ftx2 ft and fixing the same in wall by necessary nuts, bolts etc. Incl. Supply and fixing of 3 nos. 100A, 415V, Porcelain Fuse carried and base (Havells make, cat no: IHKKRN4100) and neutral bar at wooden board.
Supplying and fixing double door Horizontal TPN MCB Distribution board with IP-42/43 protection, concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment. 8 way Enclosure (607717)
Supplying and fixing double-door SPN MCB Distribution Board with IP-42/43 protection, concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment.a) 2+4 way
Supplying and fixing double door sheet steel (16SWG), powder coated cable end box for TPN DB horizontal / vertical enclosure with IP-42/43 protection, on angle iron frame on wall & mending good the damages to original finish with nuts bolts etc incl. provision for earthing attachment. 8 way Horizontal.
Supplying and fixing 240/415 V MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connection.a) 6-32A SP MCB
b) 6-32A DP MCB
c) 63A FP MCB
Supply & Fixing Socket type fan regulator (Step type) (Brand approved by EIC) on existing sheet metal switch board with bakelite/perspex top cover by screw after making housing for regulator knob by cutting bakelite/perspex top cover incl. making necy. connections etc.
Supplying & Fixing of Box type fan clamp of 150mm dia & 80mm depth made of 16 SWG CRCA sheet with one end duly sealed by cover, properly welded, incl. S&F 12mm dia 600mm long MS rod duly bent by heat treatment at the centre position of rod to grip fan bobbin properly, incl. binding the rod and fan box with reinforcement by 22 SWG steel binding wire, incl. supplying & covering the box with alkathene sheet, placed in order to prevent concrete from entering the box.
Fixing only ceiling fan complete with blades, canopy, fork, rubber bush etc. incl. S&F connecting wire for down rod upto 30 cm incl. painting the rod with approved paint and making necessary connection as required by 2x1.5 sqmm flexible copper wire.
Fixing only exhaust fan after making hole in wall and making good damages and smooth cement finish etc. as practicable as possible and providing necy. length of PVC insulated wire and making connection for exhaust of following diameter: 300MM
Supply & Fixing louver shutter on wall with necy. bolts & nuts (6 mm dia x 62 mm long) 30 cm Exhaust Fan (12'')
Supplying & Fixing 240 V AC/DC superior type Ding-Dong Call Bell (Anchor) on HW board incl. S&F HW board
Supply & delivery of Sweep:- 48" (1200mm) AC ceiling fan, 50-70 Watts, Speed:->=350 RPM. Air delivery:->=220 CMM, make: (Orient PSPO NEWBREEZE or SUMMERCOOL /equivalent of EPC or USHA STRIKER PLUS or CROMPTON (with safety rope) [Approved by EIC]
Supply & delivery of Sweep:-36" (900mm) AC ceiling fan, 50-70 Watts, Speed:->=380 RPM. Air delivery->=145 CMM, make: (Orient PSPO NEWBREEZE or SUMMERCOOL/equivalent of EPC or USHA STRIKER PLUS or CROMPTON (with safety rope) [Approved by EIC]
Supply & delivery of Sweep:-12" (300mm) Wall mounted fan, 50-60 Watts, Speed:-ed>=1200 RPM, Air delivery:->=40 CMM, make: (Orient Wall 11 or equivalent of EPC or USHA or CROMPTON or HAVELLS) (Approved by EIC]
Supply & delivery of heavy duty Exhaust Fan of Sweep:-12" (300mm), 240 volt, 50 Hz, AC . 50-60 Watts, Speed >900 RPM, Air delivery >=1145 CMM suitable for. [Make Orient(Model Power Flow)/EPC/Havells/Crompton Greaves] [Approved by EIC)
Laying of cable from 3/3½ core 35 sqmm to 50 sqmm on wall/surface incl. S & F MS saddles with earthing attachment in 2 x 10 SWG GI (Hot Dip) Wire, making holes etc. as necy., mending good damages and painting
Laying of one No. cable above 35 sqmm and upto 185 sqmm in underground trench 460mm wide x 760mm average depth, with brick protection on the top of the cable with 8 (eight) Nos. bricks per Mtr. including filling the space between the bricks and cable and also the trenchwith shifted soil, leveling up and restoring surface duly rammed.
Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry of XLPE/PVC armoured cables as below. For 4 core, upto 50 sqmm.
Finishing of the XLPE/PVC insulated armoured cable ends by soldering with cable sockets and insulated tapes etc., including supplying sockets, soldering materials, tapes etc. and making connection to switch, BDB and BBC etc. 3½ core 50 sqmm cable.
Supplying & fixing medium gauge GI Pipe ( ISI-Medium) Protection with necessary fittings and jointing metarials as required. 65 mm dia ISI
Supplying of 1.1 KV. Grade LT power cable, XLPE insulated, cores laid up, PVC inner sheathed aluminium armoured conductor of the following specificaion:- (make: Polycab/Gloster/Havells) 50 sqmm 4 core (A2XWY/A2XFY)
Supply and delivery of direct on line motor starter (DOL) of the following capacity:- 3-4 HP, Relay range:- 4-6 Amps, Coil supply:-190-400 Volt A.C., make:-BCH (Model No Shakti-SAWPHZ / equivalent of L&T (SS96210SOTO) or Havells (IHHDOLJATE)
Fixing only starters (for motor control) on flat iron frame / angle iron frame on wail On flat iron frame (for lower rating)
Excavation of soil for installation of Earth Electrode and filling & ramming. For Morrum Soil.
Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts. long and 1 x 4 SWG GI (Hot Dip) wire (4 Mts. long), 13 mm dia x 80 mm long GI bolts, double nuts, double washers incl. S & F 15 mm dia GI pipe protection (1 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts. below the ground level as below: By TATA-Medium GI pipe.
Earthing with 65 mm dia GI pipe (TATA-Medium)x 3.0 Mts. long and 1 No. 50 mm x 6 mm galvanized (Hot Dip) steel strip (4 Mts. long), 20 mm dia x 125 mm long galvanized bolt, double nuts, double washers including finishing both ends by making holes etc. and S & F 65 mm dia GI pipe (ISI-Medium) protection (3 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level to an average depth of 3.65 Mts
Extra for providing masonery enclosure on the top of the earth electrode of overall size 86.36 cm x 86.36 cm x 46 cm deep (below Ground level) complete with cemented brick work(1:6) of 25 cm width duly plastered with cement morter (inside) CI hinged inspection cover of size 36.56 cm x 35.56 cm with locking arrangement, GI reducer including drilling of 46 nos. 12 mm dia holes on the GI pipe.
Extra for treatment of soil by using salt & charcoal or coke for plate electrode
Suppl
ying & fixing earth busbar of galvanized (Hot Dip) MS flat 25 mm x 6 mm on wall having clearance of 6 mm from wall including providing drilled holes on the busbar complete with GI bolts, nuts, washers, spacing insulators etc. as required
e) 4x126/0.4 (16 sqmm) + 2x80/0.4 (10 sqmm) as ECC
Connecting the equipments body to earth busbar including S&F 20 mm x 3 mm galvanised (Hot Dip) MS flat on wall/floor with GI saddles as required and connection to equipments incl. drilling holes, with bolts, nuts, washers etc.
Connecting the equipments to earth busbar including S & F GI (Hot Dip) wire of size as below on wall/floor with staples buried inside wall/floor as required and making connection to equipments with bolts, nuts, washers, cable lugs etc. as required and mending good damages. No. 6 SWG
Supply & fixing of unipolar hexagonal flat mounting insulator for busbar support for fixing of neutral earth busbar at the side of D.G. foundation & location of UPS of the following specification:- i) Polyester without halogen ii) UL94 VO self-extinguishing. i) Colour red RAL 3002. iv) Operating temperature from -40 to +130°C. v) Deformation under load temperature (ASTM D643): > 200°C. vi) Dielectric constant (ASTM D150): 4/5. vii) Arc resistance (ASTM D495): > 180 s. viii) Water absorption (ASTM D570): < 0.3%.
Supply & Fixing RJ45 sitable for CAT6 cable (Brand approved by EIC) with PVC board and top cover plate on wall and making necessary connections & testing as required
Supply & Fixing Telephone socket (RJ11) Modular type (Brand approved by EIC) with PVC board and top cover plate on wall and making necessary connections & testing as required
Supplying & Drawing 2-pair Telephone cables with high density polyethylene insulated solid annealed high conductivity bare copper of dia 0.5mm in prelaid PVC rigid conduit/ in polythene pipe embeded in wall.
Supplying & Drawing LAN cable (CAT6) (Brand approved by EIC) in prelaid PVC rigid conduit/ in polythene pipe embeded in wall.
Supply and Installationof Split type room air conditioning machine of following tonnage capacity 3 star rating fifled with rotary crompresser and cooling capacity min. 6000 k cal/Hr., minimum discharge air flow 800cum mtr, 800EER ( W/W) 2.7-2.89. (Rates are inclusive of extra refrigerant pipe drain pipe connecting cable) up to the satisfaction of the EIC. 1.5 Ton (Make : Voltas) 3 star non-inverter type.
Supply & delivery of single 4ft LED tube light fitting incl. 4ft LED tube, 1200 mm, Efficacy>= 100 lm/W, THD<10%, complete with all accessories. (Mas LEDtube 1200mm) [Philips. TMC 502 P 1xT-LED 22W P3241] or equivalent of Havells, Crompton etc. [Approved by EIC]
Supplying & Fixing GI waterproof type looping cable box size 200x150x100 mm deep having 4 mm thick comprising of one 250 V 15 A kit-kat fuse unit, one NL on porcelain insulator, one compression type brass cable gland for upto 2- core 16 sqmm PVC/A cable and having lined with rubber gasketted GI top cover with brass machine screws etc., earthing terminal with lug, on steel tubular pole near base, including S&F 40x6 mm thick, MS clamps with bolts, nuts etc. including painting with anticorrosive paint
Fixing only lamp
Supply & Fixing angular batten holder (Anchor) on 75mm dia PVC round block / round bakelite on wall/ceiling.
b) 4 sqmm
Point
Part- II : Internal Electrical Works of PHC Building : Distn. wiring in 22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire (Brand approved by EIC) in 19 mm bore, 3 mm thick polythen pipe complete with all accessories embedded in wall to light/fan/call bell points with Piano key type switch (Anchor make) fixed on sheet metal (16 SWG) switch board with bakelite/perspex (wall matching colour) top cover (3 mm thick) flushed in wall incl. mending good damages to original finish. 2x2Z/0.3 (Ph. & N} and 1xZ2/0.3 as ECC. Average run 8 mtr
Supplying and Drawing 1.1 KV single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire (Brand approved by EIC) of the following sizes in the prelaid polythene pipe and by the prelaid GI fish wire and making necy. connection as required. 2x36/0.3 (2.5 sqmm) + 1x22/0.3 (1.5 sqmm) as ECC
Cutting channel of 40 mm x 40 mm size on masonry wall incl. S&F heavy gauge polythene pipe dia as stated below, by means of iron hooks and supplying and drawing 18 SWG GI Wire as fish wire incl. mending good damages to building works. 19 mm dia 3 mm thick polythene pipe without earth continuity wire.
Supplying and fixing double-door SPN MCB Distribution Board with IP-42/43 protection, concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment. 2+4 way
Supplying and fixing 240/415 V MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connection. 6-32A SP MCB
40 DP MCB
Supplying and fixing Sheet steel Main Switches on flat iron frame on wall. 30/32 A, 240V DP with fuse on L&N
Fixing only exhaust fan after making hole in wall and making good damages and smooth cement finish etc. as practicable as possible and providing necy. length of PVC insulated wire and making connection for exhaust of following diameter: 38 cm (15")
Supply & Fixing louver shutter on wall with necy. bolts & nuts (6 mm dia x 62 mm long). For Al - 38 cm Exhaust fan (15")
Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry of XLPE/PVC armoured cables as below. For 4 core, upto 50 sqmm.
Supply & delivery of heavy duty Exhaust Fan 380mm/15" Sweep. 1420 rpm А.С. Exhaust fan [Make - EPC/Havells] [Approved by EIC]
Fixing only starters (for motor control) on flat iron frame / angle iron frame on wail On flat iron frame (for lower rating)
Excavation of soil for installation of Earth Electrode and filling & ramming. For Morrum Soil.
Laying of one No. cable upto 35 sqmm in underground trench 460 mm wide x 760 mm average depth, with brick protection on the top of the cable with 8 (eight) Nos. bricks per metre, including filling the space between the brick & cable and also the trench with shifted soil, leveling up and restoring surface duly rammed
Supply & Fixing Telephone socket (RJ11) Modular type (Brand approved by EIC) with PVC board and top cover plate on wall and making necessary connections & testing as required
Supplying & Drawing 2-pair Telephone cables with high density polyethylene insulated solid annealed high conductivity bare copper of dia 0.5mm in prelaid PVC rigid conduit/ in polythene pipe embeded in wall.
Supplying and fixing compression type gland
complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry of XLPE/PVC armoured cables as below. For 3 core, upto 10 sqmm.
Supplying & fixing medium gauge GI Pipe ( ISI-Medium) Protection with necessary fittings and jointing metarials as required. 65 mm dia ISI
Finishing of the XLPE/PVC insulated armoured cable ends by soldering with cable sockets and insulated tapes etc., including supplying sockets, soldering materials, tapes etc. and making connection to switch, BDB and BBC etc. 3 core 10 sqmm cable.
Internal Electrical Works of Common Collection Site. Distn. wiring in 22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire (Brand approved by EIC) in 19 mm bore, 3 mm thick polythen pipe complete with all accessories embedded in wall to light/fan/call bell points with Piano key type switch (Anchor make) fixed on sheet metal (16 SWG) switch board with bakelite/perspex (wall matching colour) top cover (3 mm thick) flushed in wall incl. mending good damages to original finish. 2x2Z/0.3 (Ph. & N} and 1xZ2/0.3 as ECC. Average run 6 mtr
Supplying of 1.1 KV. Grade LT power cable, XLPE insulated, cores laid up, PVC inner sheathed aluminium armoured conductor of the following specificaion:- (make: Polycab Gloster/Havells) 10 sqmm 3 core (A2XWY/A2XFY
Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts. long and 1 x 4 SWG GI (Hot Dip) wire (4 Mts. long), 13 mm dia x 80 mm long GI bolts, double nuts, double washers incl. S & F 15 mm dia GI pipe protection (1 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts. below the ground level as below: By TATA-Medium GI pipe.
Supply & delivery of single 4ft Batten type LED tube light fitting, 1200 mm, Efficacy>= 100 lm/W, THD<10%, complete with all accessories. (Havells: LED Pride Plus NXT Batten 22 W 6500K) or equivalent of Philips, Crompton etc. [Approved by EIC.
Supplying 80 mm dia G.I. pipe (JINDAL/equivalent) 3.25 m long approx) in C.C foundation 0.46 m* 0.4m*0.9 m depth of 1:3:6 mixture with stone chips and supplying and fixing base plate including muffing of 0.3m*0.3m painting with 2 coats of Aluminum paint over a coat of red oxide and numbering and S/F earth bolt, cable entry socket etc
Supplying and fixing of G.I. Pole Cap for suitable size
Erection of Minipole of height 3.25 mtr to 5.0 mtr. in C.C Foundation 0.46 m * 0.46 m * 0.9 mtr depth of 1:3:6 cement concrete with hard jhama metal / stone chips including muffing of 0.3 m * 0.3 m * 0.3 m painting the pole with 2 coats of Aluminium paint over a coat red oxide.
Supplying and fixing of M.S. sole plate (450 x 450 x 6m)At the bottom of the pole
Hiring charges for scaffolding arrangement including dismantling at the end of work and carriage, for LC installation, per storey of building per vertical run
Supplying, installation, testing & commissioning fire alarm sounder with facility to make announcement, mounted in M.S. box (16 SWG) with hinged cover plate & suitable for operation with amplifier i/c line matching transformer etc. complete as required.
Supplying, installation, testing & commissioning of manual call boxes of MS construction in surface/recess with stainless steel chain & hammer assembly complete with glass and push button etc. as required.
Supplying and drawing of cable Fire Retardant PVC insulated copper conductor cable in the existing surface / recessed steel conduit of following pairs, cores and size including connections and interconnections etc. as required. Speaker cable Single pair, 2-core, 1.5 sqmm
Supplying and fixing 25 mm dia MS flexible pipe with PVC coating along with all ancillaries and accessories like coupler etc. as required.
Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry of XLPE/PVC armoured cables as below. For 4 core, upto 50 sqmm.
Supplying, installation, testing & commissioning sector panel suitable for following zones, complete with visual indications for short circuit fault, open circuit fault, fire condition and all other standard facilities as per IS:2189 with mimic diagram for all area/zone covered, complete with all connections, interconnections as required. (4 Zone)
Fixing only starters (for motor control) on flat iron frame / angle iron frame on wail On flat iron frame (for lower rating)
Supply Delivery and installation of ABC Powder type fire extinguishers (stored pressure) HSN code-84241000 conforming to IS:15683 and complete in all respect as per direction of EIC. 04 Kg with ISI marked Mono Ammonium Phosphate base Each 3157.00 ABC power conforming to IS:14609 and pressurized with nitrogen gas. Suitable for operating between (-)30ºC to (+)55ºC. Fire rating -1A & 13B
Supply, Delivery and installation of Co2 type fire extinguishers: HSN code-84241000. 4.5 Kg capacity with ISI marked Co2 type fire extinguisher squeeze grip type conforming to IS:15683:2006 made from seamless cylinder conforming to IS:7285 duly approved by Chief controller of explosive, Nagpur, fitted with ISI marked controller of explosive, Nagpur, fittet with ISI marked controlled valve conforming to IS:3224, high pressure 1 mtr. long discharge hose and horn complete with initial gas charged with carrying handle and wall mounting bracket suitable for operating between (-)30ºC to (+)55ºC. Fire rating -13B.
SITC of Fire Alarm System. : Supplying, installation, testing & commissioning of smoke detector with builtin LED and mounting base complete with all connections etc. as required.
M.S. structural works with hollow sections (square or rectangular shape) conforming to IS: 806-1968 & IS:1161-1998) connected to one another with bracket, gusset, cleat as per design, drawing & direction of Engineer-in-Charge complete including cutting to requisite shape & size, fabrication including metal arc welding conforming to IS: 816-1969 & IS: 9595 using electrodes of approved make and brand conforming to IS:814- 2004, haulage, hoisting and erection all complete. The rate includes the cost of all M.S. Hollow section, all consumables such as electrodes, gas and hire charges of all tools and plants and labour reqired for execution and all incidental chages (such as electricity, labour insurance) etc. complete. Payment to be made on the basis of calculated weight of structural memebrs of MS Holow Section as specified in relevent IS code in finished work. Payment for gusset, bracket, cleat may be made by adding the actual weight of such items with weight of finished structural members. The rates are considered for a hight of erection 8 m. / 2nd floor level from the ground. Add 1.5 % extra over the rate for each additional floor or 4m. beyond the initial 8 m. or part thereof. Item No – 2A / P-101 PWD Building structural schedule.
Supply of single core FR copper wire of 6.00 sq mm for SPV module inter connection & module to off – grid pcu and main load to Distribution / Mcb box Item no – 73 P –k-2 PWD elec vol -1 2017
Solar DCDB box suitable for 7kw for better safety at SPV module site
Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts. long and 1 x 4 SWG GI (Hot Dip) wire (4 Mts. long), 13 mm dia x 80 mm long GI bolts, double nuts, double washers incl. S & F 15 mm dia GI pipe protection (1 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts. below the ground level as below. By TATA-Medium GI pipe.
Dismantling all types of masonry excepting cement concrete plain or reinforced, stacking serviceable materials at site and removing rubbish as directed within a lead of 75 m. a) In ground floor including roof.
Distribution wiring in 1.1 KV single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC) in 25mm size PVC rigid conduit 'FR' (Precision make) incl. necy. fittings as required. [Cables as per requirement (Havels/Polycab/Finolex) and Accessories as required. [ The electric cable used shall be single core PVC insulated copper cable of size 2.5 sqmm for load output. For SPV module & to PCU inv connection 6.0 sqmm and 30sqmm for battery inter connection & to pcuinvert connection The size of wire between CCU/inv and battery should not be less than 30sqmm copper. The battery lead should be provided with the suitable battery luk (Copper) The total wire from module to PCU inverter should be cover by pvc pipe. Include 1000mtr 2.5 sqmm @ 2core copper wire FR standard 2.5 sq mm for Normal load output load output and 1.5sqmm for minimum load. ] 3 x 84/0.3 (6 sqmm) + 2 x 56/0.3 (4 sqmm) ECC
Dismantling all types of masonry excepting cement concrete plain or reinforced, stacking serviceable materials at site and removing rubbish as directed within a lead of 75 m. a) In ground floor including roof.
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
cancelled_1.pdf
pdf • 0.70 MB
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.85 MB
BOQ_2294628.xls
BOQ • 0.78 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .