Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹44.8 LAdmitted-Finance | ₹44.8 L | L1 | Admitted-Finance |
| 2 | L2₹48.9 LAdmitted-Finance | ₹48.9 L | L2 | Admitted-Finance |
| 3 | L3₹48.9 LAdmitted-Finance | ₹48.9 L | L3 | Admitted-Finance |
| 4 | L4₹49.3 LAdmitted-Finance | ₹49.3 L | L4 | Admitted-Finance |
| 5 | L5₹49.9 LAdmitted-Finance SR NO 331 2B PLOT NO 43 R H NO 02 BALDEWA RAO BUNGLOW NEWA NMC WATER TANK PATHARDI SHIVAR NASHIK 422 009 INDEX NO E 84CWE AF LOHEGAON PUNE | NASHIK | MAHARASHTRA | 422009 | ₹49.9 L | L5 | Admitted-Finance |
| Sl No | Description | Qty | Unit | SHRI SULAI ELECTRICALS L3 | United Enterprises L1 | DIAMOND ENTERPRISES L2 | YASHRAJ ELECTRICALS L4 | SV ASSOCIATE L6 | Shree Sai Samarth Enterprises L5 |
|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Comprehensive Maintenance of Water Cooled Chillar water central air conditioning plant of capacity 300 TR (2 x 150 TR Working + 1x 150 TR Stanby) of make - Voltas at Bldg No. RSDL Old P-360 =01 No by deploying Authorised representative of original Air Conditioner manufacturer exclusively,complete all as specified and directed by Engineer-in-Charge.
The Engineer/Technical staff must carry out inspection of compressor, checking pressure, checking controls/ control wiring including carring out requisite setting of controller & contactor, checking electrical circuits, cheking of leakage, cheking the operation of chiller and condensor pumps,cheking the operation of Cooling tower checking all pressure/temperature/ sensor interlocks & setting them for satisfactory running of plant, assessing oil condition & refrigerant condition and submitting its report of plant. Complete all as specied and as directed. The AC plant comprises of following equipments.
a) Chillar unit Make-Voltas, model- GSWCDXR150 = 03 Sets
b) Compressor suitable for 2X150 TR - 03 Sets
c) Condensar Unit Make Voltas Model- 09176 =03 Sets
d) Chillar water pump set back pull out type monoblock -3 Nos.
e) Condenser water pump set back pull out type monoblock -3 Nos.
g) Cooling tower of capacity 160 TR, round shape induced draft type ,direct driven propelar fan motor , fan dia meter 1500 mm,srpay nozzle arrngement with HDPE water tank Make- Wheldon -02No.
h) Electrical control panel cubical type with multi funtion display unit, MCBs, Fuse,MPD with auxilary contactor etc. complete -03 Nos. | 4 | Each Job | 25,280 ₹1.0 L | 24,900 ₹99,600 | 25,229 ₹1.0 L | 25,950 ₹1.0 L | 25,940 ₹1.0 L | 25,596 ₹1.0 L |
| 1.01j) Motor control centre cum APFC Electrical LT panel cubical type floor mounted with MCCB,MPCB,Push botton , Flash pattern voltmeter, Ammeter, ,SFU with ROH,APFC relay with contractor ,multi function meter etc. complete-01 No. k) LT panel for PAC unit, cubical type floor mounted with MCCB, MCB,Push botton , Flash pattern voltmeter, Ammeter,contractor , etc. complete- 02 Nos. l) Control devices such as thermostatic expansion valve,solenoid valve and cooling thermostatic & humidity contorl switch -03 Set m) Chilled water/ Condenser/cooling tower MS/GI piping up to 150mm dia with valves pressure gauge temperature gauge complete-01Set (ii) Contractor shall carry periodical maintenance of above mentioned equipment by providing minor servicing like greasing of bearings, replacement of glands, MS Nuts & bolts, rubber , coupling, teflon tape, insulation tape & other minor spares including cleaning of AHU filters , further cost of minor repairing & joints of pipe line is deemed to be included in quoted rate. Note for items no. 1 to 166: Quoted rate deemed to be include with cost of following : (a) Complete maintenance is to be carried out through by Authorised representative of original Air Conditioning equipment manufacturer exclusively in order to keep all the equipment in serviceable condition to achieve desired parameter inside the air conditional space. (b) To carry out the periodical maitenace of AC plant if necessary for effective functioning. (c) The contractor shall be responsible for proper functioning of all electrical/mechanical equipment and maintain the same in sound working condition to aviod the accident and breakdown (d) Routine checks necessary for satisfactory running the above plant and cooling tower complete all as diected by Engineer-in-charge. (e) Topping up of gas in case of leakage,compressor oil refill,descaling,repair to compressor, Condensor, motor,pump electrical panel,water supply valves,leakage,leaking refrigerant valves etc (f) To attend the breakdown during day and night including holiday and putting the plant in working condition in shortest possible time and including suffiecient stock of spares avilable always to insure smooth and regular functioning of AC plant .The contractor shall required to keep their own T&P to attend the fault/break down in quick successionalso Contractor required to provide minor servicing like greasing of bearings, replacement of glands, MS Nuts & bolts, rubber gasket , coupling, teflon tape, insulation tape & other minor spares including cleaning of AHU filters , further cost of minor repairing of valves & joints of pipe line is deemed to be included in quoted rate. (g) Contractor has to attend any complaint related with AC plant within 48 Hrs of intimation failing to which penalty of Rs 1000 per day per unit shall be recovered from RAR & final bill in form of recovery. complain forwarded on message/Whatsapp/e-mail/complaint slip shall be deemed as authentic complaint. (h) Contractor has to maintain Daily, Weekly, Monthly, Quarterly, Half-Yearly and Yearly checks for AC plants as per specified in PS Clause-35. (i) Items qty (SI no 1 to 277) catered in BOQ may vary during execution stage subject to site requirement no claim whatsoever on this account shall be entertained. | |||||||||
| 2.00 | All as per item No 1 above but for Water Cooled Chillar water central air conditioning plant of capacity 300 TR (2 x 150 TR Working + 1x 150 TR Stanby) at Bldg No. RSDL New P-284 =01 No | 4 | Each Job | 27,013 ₹1.1 L | 24,900 ₹99,600 | 25,650 ₹1.0 L | 26,465 ₹1.1 L | 27,700 ₹1.1 L | 25,209 ₹1.0 L |
| 3.00 | Comprehensive maintenance of water cooled chillar water central air conditioning plant of capacity 100 TR (2 x 50 TR Working ) of Make : Voltas at Bldg No. RSDM P-52 Authorised representative of original Air Conditioner manufacturer exclusively,complete all as specified and directed by Engineer-in-Charge.
The Engineer/Technical staff must carry out inspection of compressor, checking pressure, checking controls/ control wiring including carring out requisite setting of controller & contactor, checking electrical circuits, cheking of leakage, cheking the operation of chiller and condensor pumps,cheking the operation of Cooling tower checking all pressure/temperature/ sensor interlocks & setting them for satisfactory running of plant, assessing oil condition & refrigerant condition and submitting its report of each plant. Complete all as specied and as directed. The AC plant comprises of following equipments.
a) Chillar unit Make-Voltas Model-CWCDR0500MNT = 02 Sets
(b)Compressor suitable for 2X50 TR ,415 V ,50 HZ, - 02 Sets
c) Condensar Unit Make Voltas =02 Sets
d) Chillar water pump set back pull out type monoblock -2 Nos.
e) Condenser water pump set back pull out type monoblock -2 Nos.
g) Cooling tower round shape induced draft type water flow rate 400 US GPM,direct driven propelar fan motor of cap 5 HP, fan dia meter 1500 mm,srpay nozzle arrngement with HDPE water tank capacity- 100 TR Make-Delta cooling tower -01No.
h) Electrical control panel cubical type with multi funtion display unit, MCBs, Fuse,MPD with auxilary contactor etc. complete -03 Nos.
j) Motor control centre cum APFC Electrical LT panel cubical type floor mounted with MCCB,MPCB,Push botton , Flash pattern voltmeter, Ammeter, ,SFU with ROH,APFC relay with contractor ,multi function meter etc. complete-01 No. | 4 | Each Job | 18,142 ₹72,568 | 20,300 ₹81,200 | 20,142 ₹80,568 | 20,650 ₹82,600 | 23,300 ₹93,200 | 19,252 ₹77,008 |
| 3.01k) LT panel for PAC unit, cubical type floor mounted with MCCB, MCB,Push botton , Flash pattern voltmeter, Ammeter,contractor , etc. complete- 02 Nos. l) Control devices such as electronic expansion valve,solenoid valve and cooling thermostatic & humidity contorl switch -03 Set m) Chilled water/ Condenser/cooling tower MS/GI piping up to 150mm dia with valves pressure gauge temperature gauge complete-01Set (ii) Contractor shall carry periodical maintenance of above mentioned equipment by providing minor servicing like greasing of bearings, replacement of glands, MS Nuts & bolts, rubber , coupling, teflon tape, insulation tape & other minor spares including cleaning of AHU filters , further cost of minor repairing of valves & joints of pipe line is deemed to be included in quoted rate. | |||||||||
| 4.00 | Comprehensive maintenance of Air Conditioning plant 3x 8.75 TR at Signal section Bldg No. P-64 of Make Voltas Model- DCU-SR0000023 by deploying authorised representative of original Air Conditioner manufacturer exclusively,complete all as specified and directed by Engineer-in-Charge. The Engineer/Technical staff must carry out inspection of compressor, checking pressure, checking controls/ control wiring including carring out requisite setting of controller & contactor, checking electrical circuits, cheking of leakage, cheking the operation of chiller and condensor pumps,cheking the operation of Cooling tower checking all pressure/temperature/ sensor interlocks & setting them for satisfactory running of plant, assessing oil condition & refrigerant condition and submitting its report of each plant. Complete all as specied and as directed. The AC plant comprises of following equipments. The AC plant comprises of 03 compressor unit , Make- Danfoss Model: SZ-11054VC-(02 Running+01 Standby), Condenser water pump set back pull out type monoblock -02 Nos, Cooling tower round shape induced draft type ,direct driven propelar fan motor , fan dia meter 1500 mm,srpay nozzle arrngement with HDPE water tank capacity-20 TR, Make- Delta -01No. Air Handling Unit-01 No, LT panel for PAC unit, cubical type floor mounted with MCCB, MCB,Push botton , Flash pattern voltmeter, Ammeter,contractor , etc. complete- 01 Nos. Contractor shall carry periodical maintenance of above mentioned equipment by providing minor servicing like greasing of bearings, replacement of glands, MS Nuts & bolts, rubber , coupling, teflon tape, insulation tape & other minor spares including cleaning of AHU filters , further cost of minor repairing & joints of pipe line is deemed to be included in quoted rate. | 4 | Each job | 15,521 ₹62,084 | 14,600 ₹58,400 | 14,833 ₹59,332 | 15,030 ₹60,120 | 18,020 ₹72,080 | 14,290 ₹57,160 |
| 5.00 | Comprehensive maintenance of central AC plant of Air cooled capacity 6 x 8.75 TR at ASD-23 Bldg No.P-51 of Make Voltas,Model no:-SC875DGR407 connected to AHU with 2 circuit of 03 nos of out door unit each by deploying authorised representative of original Air Conditioner manufacturer exclusively,complete all as specified and directed by Engineer-in-Charge. The Engineer/Technical staff must carry out inspection of compressor, checking pressure, checking controls/ control wiring including carring out requisite setting of controller & contactor, checking electrical circuits, cheking of leakage, checking all pressure/temperature/ sensor interlocks & setting them for satisfactory running of plant, assessing oil condition & refrigerant condition and submitting its report of each plant. Complete all as specied and as directed. | 4 | Each Job | 17,439 ₹69,756 | 15,300 ₹61,200 | 15,679 ₹62,716 | 17,390 ₹69,560 | 18,310 ₹73,240 | 16,466 ₹65,864 |
| 6.00 | Comprehensive maintenance of central AC plant of Air cooled capacity 3 x 8.75 TR at ASD-30 Bldg No.P-51 at of Make Blue Star,Model no:- DPA1052R1A connected with integrated AHUand 03 nos of out door unit each by deploying authorised representative of original Air Conditioner manufacturer exclusively,complete all as specified and directed by Engineer-in-Charge. The Engineer/Technical staff must carry out inspection of compressor, checking pressure, checking controls/ control wiring including carring out requisite setting of controller & contactor, checking electrical circuits, cheking of leakage, checking all pressure/temperature/ sensor interlocks & setting them for satisfactory running of plant, assessing oil condition & refrigerant condition, cleaning of filetr , servicing of package unit and submitting its report of each plant. Complete all as specied and as directed. | 4 | Each Job | 10,506 ₹42,024 | 10,700 ₹42,800 | 11,093 ₹44,372 | 10,335 ₹41,340 | 12,820 ₹51,280 | 10,347 ₹41,388 |
| 7.00 | Comprehensive maintenance of central AC plant of Air cooled capacity 3 x 11 TR at ASD-30 Bldg No.P-51 at of Make Blue Star,Model no:- DPA1321R1A connected with integrated AHUand 03 nos of out door unit each by deploying authorised representative of original Air Conditioner manufacturer exclusively,complete all as specified and directed by Engineer-in-Charge. The Engineer/Technical staff must carry out inspection of compressor, checking pressure, checking controls/ control wiring including carring out requisite setting of controller & contactor, checking electrical circuits, cheking of leakage, checking all pressure/temperature/ sensor interlocks & setting them for satisfactory running of plant, assessing oil condition & refrigerant condition, cleaning of filetr , servicing of package unit and submitting its report of each plant. Complete all as specied and as directed. | 4 | Each Job | 10,878 ₹43,512 | 10,200 ₹40,800 | 12,594 ₹50,376 | 12,390 ₹49,560 | 12,450 ₹49,800 | 13,526 ₹54,104 |
| 8.00 | Comprehensive maintenance of VRF/ VRV system Type Air conditioners with connected AHU/ indoor units by deploying Original Equipment Manufacturer (OEM) trained & experienced Engineer/Technical staff for the following equipment located at various buildings at AFLE BUILDING Area in HAL Factory premises including testing electrical connections to inspect the operation of VRF type Air conditioners with connected AHU/ Indoor units and carring out preventive maintenance as per standard practice or as per OEM recommendations, To carry out the periodical maitenace of VRF AC plant for effective functioning.and carrying out repair to defective components/ equipment, detection of leaks & rectifying the same, charging/topping up of refrigerant gas complete all as specified and directed.The contractor shall be responsible for proper functioning of all electrical/mechanical equipment and maintain the same in sound working condition to aviod the accident and breakdown. Routine checks necessary for satisfactory running the above plant complete all as diected by Engineer-in-charge. The contractor has tp attend the breakdown during day and night including holiday and putting the plant in working condition in shortest possible time and including suffiecient stock of spares avilable always to insure smooth and regular functioning of AC plant
1. VRF Typer AC Plant 3 x 14 HP = Total 42 HP
2. VRF Typer AC Plant 1 x 16 HP = Total 16 HP
3. VRF Typer AC Plant 1 x 20 HP = Total 20 HP
.Note for items no.8:- Spares for items should be measured and paid under relevent CA items | 4 | Each job | 25,923 ₹1.0 L | 19,500 ₹78,000 | 29,963 ₹1.2 L | 26,020 ₹1.0 L | 35,140 ₹1.4 L | 32,046 ₹1.3 L |
Updated dates
Tender Value
₹45 L
EMD Value
₹90,000
Closing Date
4 May 2026, 6:00 pmClosed
CWE AF NAGPUR
HQ CWE AF NAGPUR VAYUSENA NAGAR, NAGPUR 440007 MILITARY ENGINEER SERVICES
REPAIR MAINTENANCE OF CERTAIN AIR CONDITIONING PLANTS INCL SUPPLY OF REFRIGERANT GAS AT 11 BRD UNDER GE (AF) OJHAR
2026_MES_756998_1
80746/E8
Open Tender
Civil Works
GE AF OJHAR
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
GE AF OJHAR
₹90,000
Yes
14 May 2026
20 Mar 2026
6 May 2026
20 Mar 2026
4 May 2026
27 Apr 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount | Item Code |
|---|---|---|---|---|---|---|
Comprehensive Maintenance of Water Cooled Chillar water central air conditioning plant of capacity 300 TR (2 x 150 TR Working + 1x 150 TR Stanby) of make - Voltas at Bldg No. RSDL Old P-360 =01 No by deploying Authorised representative of original Air Conditioner manufacturer exclusively,complete all as specified and directed by Engineer-in-Charge.
The Engineer/Technical staff must carry out inspection of compressor, checking pressure, checking controls/ control wiring including carring out requisite setting of controller & contactor, checking electrical circuits, cheking of leakage, cheking the operation of chiller and condensor pumps,cheking the operation of Cooling tower checking all pressure/temperature/ sensor interlocks & setting them for satisfactory running of plant, assessing oil condition & refrigerant condition and submitting its report of plant. Complete all as specied and as directed. The AC plant comprises of following equipments.
a) Chillar unit Make-Voltas, model- GSWCDXR150 = 03 Sets
b) Compressor suitable for 2X150 TR - 03 Sets
c) Condensar Unit Make Voltas Model- 09176 =03 Sets
d) Chillar water pump set back pull out type monoblock -3 Nos.
e) Condenser water pump set back pull out type monoblock -3 Nos.
g) Cooling tower of capacity 160 TR, round shape induced draft type ,direct driven propelar fan motor , fan dia meter 1500 mm,srpay nozzle arrngement with HDPE water tank Make- Wheldon -02No.
h) Electrical control panel cubical type with multi funtion display unit, MCBs, Fuse,MPD with auxilary contactor etc. complete -03 Nos. | - | Each Job | - | - | itemH1 |
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.67 MB
PS80746.pdf
Tender Documents • 1.13 MB
BOQ_847945.xls
BOQ • 1.21 MB
Download all tender documents and submit your bid