Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹43.4 LAccepted-AOC GC ROAD ABDUL LATIF ROAD PO TITAGARH KOLKATA 700119 | 24 PARAGANAS NORTH | WEST BENGAL | 700119 | L1 | Accepted-AOC Accepted | |
| 2 | L2₹46.7 L+₹2.9 L (6.68%)Rejected-Finance 3 IBRAHIM ROAD KHIDDERPORE KOLKATA 700023 | KOLKATA | WEST BENGAL | 700023 | L2 | Rejected-Finance Being higher bid value | |
| 3 | L3₹51.9 L+₹8.1 L (18.4%)Rejected-Finance BHANGARMATH THAKURANI CHAWK PO SAMABYPALLY BALLY HOWRAH 711 205 WEST BENGAL | HOWRAH | WEST BENGAL | 711205 | L3 | Rejected-Finance Being higher bid value | |
| 4 | L4₹52.4 L+₹8.6 L (19.7%)Rejected-Finance G C ROAD ABDUL LATIF ROAD PO TITAGARH P S RAHARA KOLKATA 700 119 | 24 PARAGANAS NORTH | WEST BENGAL | 700119 | L4 | Rejected-Finance Being higher bid value | |
| 5 | L5₹53.1 L+₹9.3 L (21.2%)Rejected-Finance 6A BANAMALI GHOSHAL LANE KOLKATA 700034 | KOLKATA | WEST BENGAL | 700034 | L5 | Rejected-Finance Being higher bid value |
Tender Value
₹44 L
EMD Value
₹88,000
Closing Date
2 Jun 2023, 6:00 pmClosed
GE ALIPORE KOLKATA
NO 1 NATIONAL LIBRARY AVENUE, ALIPORE, KOLKATA 700027
REPAIR TO FLOORING, WALLS, RCC STRUCTURAL MEMBERS I.E BEAMS, COLUMNS, FINS, CEILING, PARAPETS AND OTHER CONNECTED WORKS IN CH (EC) AND REPAIR/MAINT OF FAN GEYSERS, REWIRING, LIGHTS ANDFITTINGS OF DEFI TECH, 100 BEDS, CMDC AND OTHER LOCATION OF CH (E
2023_MES_595061_1
GE/ALP (8189B) KOLKATA OF 2023-24
Open Tender
Civil Works
Item Rate
180 days
GE ALIPORE KOLKATA
Class D and category a (i)
9 documents required · 9 mandatory
₹500
GARRISON ENGINEER ALIPORE
₹88,000
Yes
GE ALIPORE KOLKATA
10 Oct 2023
12 May 2023
9 Jun 2023
12 May 2023
2 Jun 2023
26 May 2023
12 May 2023 - 19 May 2023
20 May 2023
Amount
Taking down chowkhats or frames with shutters ( without taking off shutters from the frames) area not exc 1.5 sqm complete all as specified and directed.
Taking down shutter and refixing in same opening size of shutter exc 1.0 sqm but not exc 2 sqm each complete all as specified and directed.
Resuring, Easing /adjusting without taking down shutter size of shutter exc 1.0 sqm but not exc 2 sqm each complete all as specified and directed..
S & F for 30 mm thick flush shutters, solid core construction, with block board core and plywood face panels, commercial type complete all as specified and directed.
S&F for factory made solid panel PVC door frame of size 50mmx47mm out of 5mm plain colour PVC sheet reinforced with M.S. square tube,incl holdfast all as per specification and drawing. Shown on SSR.
S&F for factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of MS tube for top and bottom rails MS frame shall be covered with heat moulded plain colour PVC 'C' channel having a PVC sheet strip of 20 mm width stuck inside with solvent cement for top rail and bottom rail on either side and as gap insert for top rail and bottom rail paneling of plain colour PVC sheet to be fitted in the MS frame welded/seated to the stiles and rails with suitable PVC sheet beading and jointed together with solvent cement and fixing in the frame at site as per specification and drawing. Shown on SSR.
S&F for 100 mm long butt hinge, stainless steel complete all as specified and directed.
S&F for aluminium anodised handles cast type, anodised 150 mm long complete all as specified and directed.
S&F aluminium anodised tower bolt cast type, anodised 200 mm long complete all as specified and directed.
S&F for 300mm long sliding door bolts with hasp stapple (bolt type) and fixing clips of sheet cast or extruded sections and fixing bolts and sliding bolts of extruded or cast aluminium alloy complete all as specified and directed.
S&F for PVC ventilator fixed type half portion 4 mm frosted glass and half portion stainless steel wire cloth, 0.63 mm dia of wire and average width of aperture 1.18 mm including fixing of ventilator including taking down old ventilator complete all as specified and directed.
Taking down aluminium door(any size) and refixing in same position ,change of pivot, beading, gasket, setting of door and change of damaged style /rail any length in aluminium section thickness not less 1.50 mm match with existing anodised /power coated complete all as specified and directed.
S&F for floor door stopper of overall length of cover plate in 150mm Aluminium alloy body abd tonuge with hard drawn steel spring complete all as specified and directed.
M&L for preparing old wooden surfaces of any description over 10 cm width or girth and applying one coat of synthetic enamel paints complete all as specified and directd.
M&L for preparing old steel surfaces of any description over 10 cm width or girth and applying one coat of synthetic enamel paints complete all as specified and directd.
Hacking out old broken glass (any thickness, size, quality or description) from wooden frames/steel/aluminium frames glazed with putty or fixed with beads complete all as specified and directed.
S&F for 4.8 mm thick plain sheet glass ordinary quality and glazed with oil putty or fixed with fillets 2nd class hard wood of sectional area of glass not exc 0.5 sqm each pane complte all as spd and directed.
S & F for 4.8 mm thick sheet glass, ordinary quality and glazing with oil putty in squares exceeding 0.5 Sqm in each pane complete all as specified and directed.
S&F for Powder coated aluminium door shutter fixed with rubber gasket, stopper, cleats, handles etc complete incl aluminium door styles of size 80 mm x 38 mm x 3.00 mm and aluminium door section of top, bottom and lock rail shutter frame of 80mm x 38mm x 3.00 incl taking down old door with necessary all fitting complete all as specified and as directed.
S&F in repair aluminium anodised Partition wall of frame size 80mm x 38mm x 3.00 mm with standard beads/glazing clips, locking arrangement etc with necessary all fittings complete all as per manufacturer's instructions and all as specified and as directed.
M&L for 9 mm thick prelaminated partilce boards interior grade prelaminated one side with decorative choice lamination & other side balancing white lamination fixed with screw to timber frame for pelmet boxes,aluminium door and aluminium partitions complete all as specified and directed.
S&F for Powder coated aluminium windows/ventilator fixed type ,without sash bar weighing 0.55 kg/m including, necessary joining cleats, glazing clips, rubber packing, powder coated aluminium snap beading, screws and taking down old window/ventilator complete all as specified and as directed.
S&F for anodised powder coated aluminium (minimum thickness of powder coating 50 micron) frame for doors, windows, ventilators etc with one or more rebates including joining cleat for fixing etc. complete all as specified and directed.
S & F in repairs Aluminium body door closer hydraulically regulated, designation No. 3 universal type, suitable for door shutters of 851-1000 mm in width & weight between 61 to 80 Kg.
S&F in repair 5 mm thick beveled edge best quality looking mirror of size 600x450 mm fixed with screws complete all as specified and directed.
S&F in repair stainless steel soap dish fixed in wall with screws complete all as specified and directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and directed.
M&L for non skid, joint free, coloured ceramic tiles 6-7mm thick (Square/Rectunglar), area of each tile exc 0.11 Sqm but not exc 0.18 Sqm. as in floor etc set and jointed in neat cement slurry and pointed in white or coloured cement to match the coloured tiles laid over and including 15mm thick screed bed in CM (1:4), complete all as specified and directed .
M&L for coloured, glazed ceramic tiles size 300x200x6-7mm thick, in dado/skirting etc, set and jointed in neat cement slurry and pointed in white cement mixed with pigment to match, laid with and including over 10mm thick rendering in CM (1:3) complete all as specified and directed.
M&L for coloured, glazed ceramic tiles size 450x300x 6-7mm thick, in dado/skirting etc, set and jointed in neat cement slurry and pointed in white cement mixed with pigment to match, laid with and including over10 mm thick rendering in CM (1:3) complete all as specified and directed.
M&L for light shade Vitrified ceramic tiles 9-10 mm thick (Sqr/ rectangular) Polished, area of each tiles n.exc. 0.36sqm, in floors etc. set and jointed in neat cement slurry over a bedding layer of scread bed 15 mm thick in CM 1:4 and pointed in white/colour cement to match. complete all as specified and directed.
M&L for Granite(of any type) 18-20 mm thick for slab machine cut, bedded & jointed with grey cement slurry & pointed with white cement with admixture of pigment to match the shade of granite stone over and including 15 mm thick screed bed in cement mortar (1:4) including grinding & polishing fixed in slab/steps complete all as specified and directed.
Chipping of unsound /weak concrete materials including cover plaster from RCC structural member i.e. beams, columns etc. 50 mm average thickness including tapering all edges, making square shoulders of cavities air and cleaning of exposed concrete surface of lightly picking materials by manual method including foreign materials , loose concrete/aggregate etc and disposal of all debris out side of MOD land and complete all as specified and as directed (upto 8 storey bldg.)
Chipping of unsound /weak concrete materials including cover plaster from RCC structural member i.e. slabs ,lintel,chajja, fin , facia etc. 25 mm average thickness including tapering all edges, making square shoulders of cavities air and cleaning of exposed concrete surface of lightly picking materials by manual method including foreign materials , loose concrete/aggregate etc and disposal of all debris out side of MOD land and complete all as specified and as directed (upto 8 storey bldg.)
Removing of concrete all around reinforcement bar upto 12 mm dia and over from behind the reinforcing bars average 25mm (but not less than 15mm air gap)by manual methods (using wire brushing ,chiselling etc) and applying chloride free rust removing chemical on rusting steel reinforcement bar and removing all rust from steel reinforcement bar by emery paper and cleaning the area throughly by water and allow it to dry and totally rust free of reinforcement bar all as complete as per manufacturer's instruction as specified and as directed. (upto 8 storey bldg.) Make (Rust removing chemical ):- Reebaklens RR of FOSROC or quivalents solutions of SIKA/STP
Material and labour for preparation of existing reinforcement surface by brush and application two component epoxy zincrich primer on existing reinforcement surface of minimum specific gravity 1.75, adhesive bond strength with steel is 1.50N/mm2 and maximum coverage area 5.00 Sqm per litre complete all as specified and directed. (upto 4 storey bldg.) (Including necessary scaffolding) Make- Nitozinc primer of FOSROC or equivalents chemical as approved by the GE.
Material and labour for introducing new reinforcement bars upto 12 mm dia and over for structural connection in RCC beams, columns, lintel and slabs including power drilling holes of appropriate diameters in reinforced or plain cement concrete to a minimum depth of 150mm and upto 200mm including power drilling,fixing the reinforcement in position using epoxy, cleaning of loose dust by blowing air, sealing with epoxy cartridges etc all as specified and directed. (upto 4 storey bldg.) (Including necessary scaffolding)
Material and labour for placing in position free flow shrinkage cementitious micro concrete of compressive strength, flexural strength shall not be less than 50 MPa at 28 days , 5MPa at 28 days respectively for strengthening of beams, columns & other structural elements of average thickness 50mm and including surface preparation & suitable type formwork etc. as per manufacturers instruction complete all as specified and as directed. upto 4 storey bldg.Make (micro concrete):-Renderoc RG of FOSROC or equivalents solutions of SIKA/STP
Supply and materials for application of two component structural grade polymer modified reinstatement mortar of compressive strength, flexural strength shall not be less than 45 MPa at 28 days , 7MPa at 28 days respectively ( maximum coverage area 1.3 sqm per 25 kg pack @ 10 mm thickness) over a coat of epoxy Bonding agent on existing surface for strengthening of beams, columns & other structural elements of average thickness 25mm and morter shall be applied in layers n.exc 6mm thick in layers and including surface preparation as per manufacturers instruction complete all as specified and directed. (upto 8 storey bldg.) Note:- This item shall be execution where shuttering is not possible or small patch repairs of structural elements .Make (polymer modified reinstatement mortar):- Renderoc S2 of FOSROC or equivalents solutions of SIKA/STP.
Material and labour for applying of high efficiency polymeric resin base film forming curing agent/compound over concrete surface and maximum coverage area 5.00 Sqm per litre as per manufacturers instruction complete all as specified and as directed. upto 8 storey bldg.(INCL necessary scaffolding) Make:- Concure LP90 of FOSROC or equivalents solutions of SIKA/STP/ Maruti / Choksey chemicals.
Providing of double layer self supporting steel scafolding to external perimeter of building duly cross braced and properly aligned for the functional aspect and safety of the building upto 8 storey bldg and including 21 Mtr high complete all as specified and as directed.(for strutural wk).
Material & Labour for grinding and polishing of old kota stone.marble granite flooring, landing, risers,steps ,mosaic floor/wall complete all as specified and as directed.
Demolition of brickwork or stone boulder masonry, built in cement mortar or cement lime mortar including all quoins,arches, pillars,etc. but excluding ashlar facings, dressed stonework and precast concrete articles complete all as specified and directed.
Material and labour for brick work with fly ash brick straight or curved on plan exc. 6m mean radius, built in cement mortar (1:6) complete all as specified and directed.
M & L for brick work with fly ash bricks old size, straight or curved on plan to any radius in half brick thick walls built in cement mortar (1:4) complete all as specified and directed.
Demolition of PCC in ground floor and pavings not exc 15 cm thickness below or above ground level complete all as specified and directed.
M&L for 50 mm thick PCC (1:2:4) type B1 (using 20 mm graded stone aggregate) as in flooring, finished even and smooth with using extra cement complete all as specified and directed.
Taking down cement plaster on brick or stone wall surfaces including glazed tiles wherever exists including raking out joints, hacking for key and scrubbing down with water complete all as specified and as directed.
M&L for 15mm thick plastering on other than fair faces of ceiling surfaces in CM (1:4) surface finished even and fair complete all as specified and directed.
M&L for 15mm thick plastering on fair faces of brick wall and concrete surfaces in CM (1:4) surface finished even and fair complete all as specified and directed.
M&L for complete removal of existing treatment of old decorated wall surfaces complete all as specified and directed.
M&L for 3mm thick wall care putty on old decorated wall surfaces complete all as specified and directed.
M&L for preparation of plastered and unplastered surfaces of old decorated walls and applying one coat of acrylic oil emulsion distemper complete all as specified and directed.
M&L for repair of old decorated walls and applying two coats of acrylic oil emulsion distemper complete all as specified and directed.
M&L for complete removal of existing treatment of old decorated ceiling surfaces complete all as specified and directed.
M&L for old decorated ceiling surfaces and applying 3mm thick wall care putty complete all as specified and directed.
M&L for preparation of plastered and unplastered surfaces of old decorated ceiling and applying one coat of acrylic oil emulsion distemper complete all as specified and directed.
M&L for old decorated ceiling and applying two coats of acrylic oil emulsion distemper complete all as specified and directed.
M&L for preparing and removing existing surfacesn new decorated plastered or unplastered surfaces of wall, pillasters, cornices etc and applying two coats of acrylic distemper with wall care putty complete all as specified and as directed.
M&L for preparing new decorated plastered or unplastered surfaces of ceiling, pillasters, cornices etc and applying one coat 1 mm thick wall care putty with two coats of acrylic distemper complete all as specified and as directed.
S&F in repair sinks without drainage board made of stain less steel 1mm thick,kitchen with plugs, washer and wastes; Including bedding in cement mortor to dwarf wall or including fixing cantilever brackets and connecting union to pipe bowl size 410mmx330mmx160mm complete all as specified and directed.
S & F in repair stainless steel toilet paper holder fixed with CP screws in wall , complete all as specified and directed.
S & F in repair sheet glass shelf assembly consisting of 5.5mm thick sheet glass shelf 12cm wide with chromium plated bracket guard and railing 60cm long complete all as specified and directed.
S & F in repair 110/125 mm floor trap fixed in floor with grating incl jointing with solvent (1:2:4) cement concrete, complete all as specified and directed.
S&F in repairs 32 mm dia waste pipe for wash hand basin and urinal down pipe complete all as specified and directed.
S&F in repairs vitreous China wash down water closet pan ( padestal pattern) including PVC seat cover , (excluding fixing bolts, flushing cistern and flush pipe) , including connection to drain ( or outgoing pipe) and to flushing pipe etc. complete all as specified and directed.
S&F in repair PVC valveless, symphonic action type low level flushing cistern white with inlet ball valve, float and handle including brackets, 10 ltr capacity complete with flush pipe(Long bend) 32mm dia complete all as specified and directed.
S&F in repair vitreous china wash hand basin, white, flat back, size 550mm x 400mm, excluding chain and plug and porcelain stopper but including cutting for and pinning in ends of and including brackets, waste pipe & CP brass waste coupling of 32mm dia complete all as specified and directed.
S&F in repair 15mm bore CP angular valve,with crutch handle, screwed for iron pipe or for brass ferrule and fixed complete all as specified and directed.
S & F in repairs 15 mm dia CP Bib taps, with crutch handle, screwed down, screwed for iron pipe or for brass ferrule and fixed complete all as specified and directed.
S&F in repair 15 mm bore pillar taps, Chromium Plated, with capstan heads, chromium plated, fancy type screwed down for pipe, high pressure , with or without 'lettered ' 'HOT' or 'COLD' with long screwed shanks and fly-nuts , screwed for iron pipe complete all as specified and directed.
S&F in repair 15 mm bore Chromium Plated, with capstan heads, fancy type screwed down for pipe, high pressure 'HOT' and 'COLD' Mixer tap (3 in one) with long screwed shanks and fly-nuts, complete all as specified and directed.
S&F in repair 600 mm PVC connection 15 mm size with PTMT nut complete all as specified and directed .
S&F in repair 20 mm bore (Outer dia) CPVC pipes of SDR 11and plain CPVC SDR 11 fitting fixed on wall or floor (concealed ), ceiling or laying in floors complete all as specified and directed.
S&F in repair 25 mm bore (Outer dia) CPVC pipes of SDR 13.5 and plain CPVC SDR 11 fitting fitting fixed on wall or floor, ceiling or laying in floors complete all as specified and directed.
S&F in repair 50 mm bore (Outer dia) UPVC pipes of SCH-40 and plain UPVC SDR 11 fitting fixed on wall or floor, ceiling or laying in floors complete all as specified and directed.
S&F in repairs towel rail 600 mm long of brass chromium plate 20mm dia fixed with and including chromium plated brass screws & wooden/plastic cleats complete all as specified and directed.
Cleaning and dusting of GI pipes line 15 to 25 mm dia by GI wire and pressure pump and washing down whole GI line complete all as specified and directed.
S&F in repair PVC Health faucet with all necessary fittings complete all as specified and directed.
Demolition of cement concrete (reinforced) in ground floor and paving not exceeding 15 cm thick (below or above G.L) complete all as specified and directed.
M&L for RCC(Nominal Mix), in type-B1, (1:2:4) (using 20mm graded stone aggregate) pre cast slabs supported on walls for cup board and Kitchen slabs complete all as specified and directed.
M&L for mild steel TMT bars 10mm dia and over, cut to length, bent to shape required including cranking, bending, hooking ends and binding with mild steel wire (annealed) not less than 0.9mm dia or securing with clips quality conforming to releavant IS complete and all as specified and directed.
S&F in repair 15 mm bore CP shower fancy type 150mm long neck complete all as specified and directed.
M&L for L-shaped rubberised corner guard for sharp vertical edges of length 1000mm, width 100 x 100mm reflective type of thickness 10mm complete all as specified and directed.
Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc. complete all as specified and directed.
Taking down carefully sub main wiring of size upto 16 Sqmm including making good disturbed surfaces of walls, ceilings etc all as specified and directed.
Material and labour for point wiring for Modular fitting, for one light/fan/call bell point with 1.5 sqmm PVC insulated FRLSH unsheathed copper cable multistranded conductor 1100 volts grade, concealed type, controlled by one way switch including 1.5 sqmm PVC FRLSH insulated unsheathed copper cable multistrand conductor 1100 volts grade for continuity earth wire connected to common earth dolly drawn through non metallic rigid PVC heavy duty concealed conduit of size 25mm dia with wall thickness not less than 1.6 mm including conduit accessories like bends, tees junction boxes, etc including 1.5 Sq mm, single core PVC insulated unsheathed multi stranded copper conductor FRLSH cable (Green) 1100 Volts grade as earth continuity wire connected to earth dolly and including modular sunken galvanized terminal boxes of same make of switch/ socket/ regulator with sleek and curvy cover plates, for mounting of modular switches, sockets, complete after and making good the distrubed surfaces as per the existing complete all as specified and as directed.
All as per item No 87 here-in-before but for one light point controlled by two way switch complete all as specified and directed.
All as per item No 87 here-in-before but for 3 pin 6 Amps socket outlet modular type on the same board with 1.5 sqmm cable complete all as specified and directed.
All as per item No 87 here-in-before but for 3 pin 6 Amps socket modular type on the independent board with 1.5 sqmm cable complete all as specified and directed.
All as per item No 87 here-in-before but for socket modular type 2 in 1,3 pin 5/15 Amp on independent board with 2.5 Sqmm PVC unsheathed copper cable and 1.5 sqmm copper conductor cable as earth continuity conductor complete all as specified and directed.
Supply and Fixing for modular switch single pole, one way, 6 Amp, 1 module, complete all as specified and directed.
Supply and Fixing for modular switch single pole, one way, 16 Amp, 1 module, complete all as specified and directed.
Supply and Fixing for modular Socket, 6 Amp, 2/3 pin combined 2 module, complete all as specified and as directed.
Supply and Fixing for modular Socket, 6/16 Amp, 2/3 pin combined 2 module, complete all as specified and as directed.
Supply and Fixing for modular switch single pole, two way, 6 Amp, 1 module, complete all as specified and directed.
Supply and Fixing for modular bell push 6 Amp, single pole, 1 module, complete all as specified and as directed.
Supply and Fixing in repair bell multi music type, complete all as specified and as directed.
Supply and fixing ceiling rose surface bakelite three terminal 65 x 50mm, PVC/Polycarbonate,isolated body complete all as specified and as directed.
Supply and Fixing modular step type fan regulator, 120W, 2 module, complete all as specified and directed.
Material and labour for point wiring for one light/fan/call bell point with 1.5 sqmm PVC insulated FRLSH unsheathed copper cable multistranded conductor 1100 volts grade controlled by one way switch including 1.5 sqmm PVC (FR-LSH) insulated unsheathed copper cable multistrand conductor 1100 volts grade for continuity earth wire connected to common earth dolly drawn through suitable size of non metallic rigid PVC heavy duty of size 20/25 mm dia having wall thickness not less than 1.2mm/casing & capping with all accessories and sunk cast pressed steel terminal box made out of MS sheet 1.25mm thick for mounting of fittings like switch, socket and fan regulator with 3mm thick bakalite sheet cover or for fixing of switch/sockets/regulators etc as per site requirement after and making good the distrubed surfaces as per the existing complete all as specified and as directed.
All as per item No 101 here-in-before but for one light point controlled by two way switch with 1.5 sqmm cable complete all as specified and directed.
All as per item No 101 here-in-before but for 3 pin 6 Amps socket outlet on the same board with 1.5 sqmm cable complete all as specified and directed.
All as per item No 101 here-in-before but for 3 pin 6 Amps switch socket combination on the independent board with 1.5 sqmm cable complete all as specified and directed.
All as per item No 101 here-in-before but for switch socket combination 2 in 1,3 pin 5/15 Amp on independent board with 2.5 Sqmm PVC unsheathed copper cable and 2.5 sqmm copper conductor cable as earth continuity conductor complete all as specified and directed.
S & F for socket outlet 2 in 1, 5 pin 5 Amp,230 Volts flush type.
M & L for switch socket combination 2 in 1, 5 pin 5 Amps, 240 V Flush type, complete all as specified and directed.
Supply and fixing switch socket combination 2 in 1,5/15 Amps, 230 Volts, flush type universal complete all as specified and as directed.
Supply and fixing for switch piano, flush type 5 Amps 230 Volt single pole, one way complete all as specified and as directed.
Supply and fixing for switch piano, flush type 5 Amps 230 Volt single pole, two way complete all as specified and as directed.
S&F for bell push, flush button single pole 6 amps 230 volts AC with polycarbonate body all as specified and directed.
Supply and Fixing for stepped type electronic fan regulator flush type on the existing phenolic laminated sheet etc including taking down old unserviceable regulator complete all as specified and directed.
Supply and Fixing in repair of MCB, single pole, 240 Volts, of capacity (6-32 Amps) as ordered breaking capacity 10 KA. complete all as specified and directed. (Make-Legrand Cat No-4085-87 to 4085-95 or equivalent in L&T,ABP,Havells )
Supply and fixing in repair MCB SPN, 40 to 63 Amps, 240 Volts , breaking capacity 10KA complete all as specified and directed. (Make-Legrand Cat No-4086-18 to 4086-20 or equivalent in L&T, ABP, Havells)
Supply and fixing in repair MCB TPN, 63 Amps, 240 Volts , breaking capacity 10KA complete all as directed. (Make-Legrand Cat No-4087-02 or equivalent in L&T,ABP,Havells)
Supply and fixing as in repair MCB DB SPN (double door) 12 Ways including bus bar neutral link, earth bar and din rail, recessed with wall surfaces by chase cutting and making good surfaces of wall complete all as specified and directed.
Supply and fixing as in repair MCB DB SPN (double door) 8 Ways including bus bar neutral link, earth bar and din rail, recessed with wall surfaces by chase cutting and making good surfaces of wall complete all as specified and directed.
Supply and fixing as in repair MCB DB SPN (double door) 4 Ways including bus bar neutral link, earth bar and din rail, recessed with wall surfaces by chase cutting and making good surfaces of wall complete all as specified and directed.
Supply and fixing as in repair MCB DB TPN (double door) 4 Ways including bus bar neutral link, earth bar and din rail, recessed with wall surfaces by chase cutting and making good surfaces of wall complete all as specified and directed.
Material and labour for sub main wiring for main DBs to Sub DBs with standard copper conductor 1100 volts grade of size 2.5 sqmm two runs of multistrand unsheathed PVC insulated cable (Red colour cable used for live connection & Black colour cable used for neutral connection) and 2.5 sqmm copper multistrand conductor 1100 volts grade multistrand un-sheathed PVC insulated (Green colour cable used) cable for earth continuity wire connected from main earth through PVC conduit / casing caping of size 25mm for including of all accessories after taking down existing sub main wiring and make good surface as per existing complete all as specified and directed. Note : Three runs of 2.5 sqmm and with PVC conduit shall constitute one unit.
All as per item No 120 here-in-before but with 4 sqmm cable.
All as per item No 120 here-in-before but with 6 sqmm cable.
Supply and fixing in repair building security lighting of LED 35 watts high efficennt lighting solution anodised with heat resistance with accessories provided including necessary electric connection with all accessories required for fixing/mounting with nut bolt washer & clamp support on GI pipe1.5 meters long of suitable diameter complete all as specified and as directed. (Make- Havells Cat No:ENDCITYLITPLAT+SL35WLED757 SASYBOPCWOSPD or equivalent make of Bajaj/ CG/ Philips)
Supply and fixing in repairs main stream battens fitting LED 20 watt with tube 4 feet long fixing on PVC/wooden round block complete with all accessories, prewired and flexible wire twin core from ceiling rose to terminal block complete all as specified and as directed. (Make: Havells Cat No LUMILINEBS20WLED865SPCWH or equivalent make of Bajaj/ CG/ Philips)
Supply and fixing in repairs main stream battens fitting LED 10 watt with tube 2 feet long fixing on PVC/wooden round block complete with all accessories, prewired and flexible wire twin core from ceiling rose to terminal block complete all as specified and as directed. (Make: Havells Cat No LUMILINEBS10WLED865SPCWH or equivalent make of Bajaj/ CG/ Philips)
Supply and fixing in repairs design from the renaissance era yet with a modern look using new generation technology in 35W LED to enliven outdoor areas in perfect synchronization with functionality and aesthetics. IP66 Family of post top lantern designed to complement the geometry of the area including all accessories and connection complete all as specified and as directed. Make :- Havells Cat Part No VICTORIAPT35WLE D757PSYMTOTG or equivalent make of Bajaj/ CG/ Philips
Supply and fixing in repairs aesthetically designed decorative hot dipped galvanised mild steel step 3M pole with grey powder finish. compatible for all post top range. window - Plasma cut & duly chamfered opening window of 300 x 110 mm for terminal connections & mounting accessories. window cover is fitted with allen screws to the pole including necessary PCC work complete all as specified and as directed. Havells Cat Part No DECO POLE 3M TOP dia 76mm or equivalent make of Bajaj/ CG/ Philips)
Supply and fixing in repairs or aviation yellow painted die-cast aluminium alloy housing, red coloured polycarbonate dome and accessories including suitable dia GI pipe for fixing of light with all fixing arrangement including PCC, electrical connections complete all as specified and as directed. (Make : Bajaj Cat No 24973 BJAOL 2 BC or equivalent make of Bajaj/ CG/ Philips)
Materials and labour for earthing as in repair complete with galvanised iron earth plate electrode 600 mm x 600 mm x 6 mm thick, burried directly and preferably vertically in ground, earth pit not less than 2.25 Mtr deep below ground level with top edge of the plate not less than 1.5 m below ground level connetced with galvanised strip of size 25 x 4mm by means of nuts, bolts, check nuts and washers made of galvanised iron or steel earthing lead to be protected by galvanised iron pipe 40 mm bore (medium grade) and other end connected to earthing test point or lightening arrestor or main controlling switch as directed including providing funnel with 20mm bore galvanised iron pipe (light grade), wire mesh, charcoal or coke and common salt in alternate layer of 15cm (compacted thickness) all round the earth electrode, concrete earth pit in PCC (1:3:6) type C-1 (with 20mm graded aggregate), 50 mm thick precast RCC (1:2:4) cover slab (re-inforced with 8mm dia TMT bar @ 15 cm C/C bothways and suitable handle made of 10mm dia) including necessary earth work in excavation, returning filling and removal of surplus earth upto a distance not exceeding 500 m etc all as shown on electrical plate No. 3 of MES Schedule Part-I(2009) complete including testing on completion all as specified and as directed.
Supply and fixing for earth continuity conductor of 25x4 mm galvanised iron strip with saddle and fixing screw for conductor above ground, complete all as specified and directed.
Taking down ceiling fan of any type, any make and any sweep for repairing,opening the body and blade, checking for repalcement of unserviceable spares,cleaning, overhauling, greasing, replacement of unserviceable spare by new one, re-assembling of all components in original position, testing and hanging up the same complete all as specified and directed. Note : New spare parts required for replacement shall be measured and paid seperately as 'Supply only"
Rewinding of ceiling fan, 1200mm sweep with synthetic enamel copper wire including insulation of starter with polyster paper/manllex paper with cotton binding, heat varnished and including flexbile cable for electric connection complete all as specified and directed.
Supply only ball bearing of size 6201/6202/6203
Supply only capacitor for ceiling fan 2.25 MFD complete all as specified and directed.
Taking down exhaust fan/wall mounted fan of any type, any make, by opening of body carefully checking for repalcement of unserviceable spares, including replacement of spares by new one, re-assembling of all components in original position, cleaning, oiling greasing, testing and fixed in original position Note : New spare parts required for replacement shall be measured and paid seperately as 'Supply only"
Rewinding of exhaust fan, 300mm sweep with super enamelled copper wire and insulation of starter with polyster paper/manllex paper with cotontak binding, heat varnished and complete all as specified and as directed.
All as per item No 136 here-in-before but for 350 mm sweep.
Supply only capacitor for exhaust fan 3.15 MFD complete all as specified and directed.
Taking down geyser and scraping, cleaning including brazing of inner vessel of the geyser at leakage point to made it leak proof including testing pressure and assembling of all component refixing complete for 25 Ltr capacity. Note : New spare parts required for replacement shall be measured and paid seperately as 'Supply only" under relevant items.
Supply only heating elements of 2 KW 230 V suitable for water heater of any type including connection with suitable cable complete all as specified and directed.
Supply only thermostat switch of geyser 230 V, 30 degree to 90 degree centigrade temp range to be set at 70 degree to 50 degree centi grade suitable for water heater. complete all as specified and directed.
Supply only indicating lamp, 230 V, flush type, rectangular, red and green indicator suitable for water heaters. complete all as specified and directed.
Supply only for pressure release valve 15mm bore 'T' type at inlet/ outlet or dead weight type heavy duty.
Supply only for apparatus plate , including suitable for water storage heater type 25 ltrs capacity.
All as per item No 144 here-in-before but for 50 ltrs capacity.
Supply only for fusible plug , calibrated 95 deg to 100 deg C suitable for water heater.
Supply only for PVC insulated flexible copper conductor cable (FRLS) 4 Sqmm 3 core , 1100 Volts grade conforming to IS 694.
Supply only rubber gasket as in repair for appratus plate any type/capacity all as specified and directed.
EASTERN REFRIGERATION AND ELECTRICAL CO
dutta and dutta
M/S L.R.ENTERPRISES
AUTO ELECTRICALS
DIPAK ENTERPRISE
DK Contractor
KT CONSTRUCTIONS
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .