| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹43.3 LAccepted-AOC HOUSE NO 251 E BLOCK ADARSH NAGAR BALLABHGARH FARIDABAD PIN 121004 HARYANA | FARIDABAD | FARIDABAD | HARYANA | 121004 | ₹43.3 L | L-1 | Accepted-AOC AOC is being Awarded to the lowest bidder |
| 2 | L-2₹44.5 LRejected-Finance | ₹44.5 L | L-2 | Rejected-Finance Rejected as other than lowest Tenderer |
| 3 | Rejected-Technical | - | - | Rejected-Technical Similar works submitted for eligibility criteria are not executed at High Altitude Areas, hence rejected as per PQ Criteria Para 1, Note (b) of NIT |
| 4 | Rejected-Technical 61 DANDA KHUDANEWALA NEAR GAS GODAM SAHASTRADHARA ROAD DEHRADUN 248001 | DEHRADUN | UTTARAKHAND | 248001 | - | - | Rejected-Technical Similar works submitted for eligibility criteria are not executed at High Altitude Areas, hence rejected as per PQ Criteria Para 1, Note (b) of NIT |
| 5 | Rejected-Technical H NO 5 117 BODUPPAL INDIRA NAGAR COLONY GHATKESAR MANDAL R R DIST 500 092 | MEDCHAL MALKAJGIRI | TELANGANA | 500092 | - | - | Rejected-Technical Similar works submitted for eligibility criteria are not executed at High Altitude Areas, hence rejected as per PQ Criteria Para 1, Note (b) of NIT |
Updated dates
Tender Value
₹43.7 L
EMD Value
₹87,408
Closing Date
5 Feb 2026, 6:55 pmClosed
CCE R N D ESTATES NORTH CHANDIGARH
CCE R N D ESTATES NORTH M-1026 Sector- 29A, Chandigarh - 160030
REPLACEMENT OF DIESEL GENERATING SET AC, 3 PHASE, 50 HZ, CAPACITY 320 KVA WITH AMF PANEL AT 19 CD ITM, MUSSOORIE
2026_DRDO_892570_1
CCE(EN)/DDN/DG SET/19 CD/ITM/25-26/11601A
Open Tender
Miscellaneous Works
300 days
ITM Mussoorie
All agencies enlisted with DCWandE, New Delhi in Composite Category of CC-IV Rs.60 Lakhs and above DCWandE, Enlistment Estate Management and Maintenance (DRDO-2024) under BIM-I, BIM-II, BIM-III and BIM-IV Categories are eligible with PQ Criteria.
4 documents required · 4 mandatory
₹0
₹87,408
D ESTATES NORTH CHANDIGARH
1 Apr 2026
6 Jan 2026
6 Feb 2026
6 Jan 2026
5 Feb 2026
14 Jan 2026
12 Jan 2026
PART-A ELECTRICAL WORKS
Supply, installlation, commissionig & testing of Silent Diesel Generating set, AC, 3 Phase, 50 Hz, capacity 320 KVA/256 KW with CPCB IV+ approved accoustic enclosure, radiator cooled , diesel engine devloping 395 BHP at 1500 RPM, complete with standard accessaries, coupled to alternator rated at 320 KVA/256 KW, 415 volts, mounted on channel iron base frame, complete with fuel tank of capacity 615 ltrscapacity & DEF tank of 60 ltr capacity with AMF Control Panel including 2 Nos 12 Volts rechargeable lead acid battery of suitable AH as directed by Engineer-in-Charge including disconnecting serviceable LT UG cables from existing LT panel board & old DG Set etc and reconnecting to new DG Set & AMF panel as required and directed at site complete. Generator Set Specifications: Prime, Power Rating -320 KVA/ 256 KW, 3 phases , Out put voltage & frequency (V & Hz) - 415 V, 50 Hz, power factor - 0.8 (Lagging), Current (A) -445 Amps. Engine Specifications: Required certified power for rated KVA (hp) - 395, Cooling- liquid cooled (EG compleat 50-50), DEF- AUS 32 (Premix) as per ISO22241, Aspiration, turbocharged, charge air cooled, nos of cylinders- 6, In-line, Bore(MM) x stroke(MM) - 114x145, Compression ratio - 16.7 : 1, displacement Ltr - 8.9, Fuel - High speed Diesel, Performance class of DG Set, ISO 8528-5 G2, starting system- 24 volts DC electrical, Lub oil specification- CK4, Lub oil sump capacity , High- Low level (in Ltr) - 30- 19.7 ltr, Total lub oil system capacity - 31.7 ltr, Exhaust pipe size (in inch)- 6 , Total weight(engine + radiator) - 918.2 Kg, Length x widthx height ( in MM) - 1128 x791x 1277, Mean piston speed (m/s) - 7.2 , Combution air intake @100 % load (+-5%) - 689 CFM, Exhaust temperature (*C) - 539 *C. All as approved by Project Manager / Engineer-in-Charge.
Alternator Specifications: Alternator suitable for continuous operation generating 320 KVA at 1500 RPM, 415 Volts, 0.8 power factor (lag) suitable for 50 Hz, 3 phase, 4 wire system, confirming to BS 5000 / IS 4722. The alternation is brushless type, screen protected, revolving field, self-excited, self-regulated through an AVR. The alternator has the following features: - - + 1.0% voltage regulation (max.) in static conditions. - IP: 23 protection with insulation class H. - Permissible overload of 10% for one hour in 12 hours of operation.
Supplly and fixing LT UG cable with aluminium conductor, 1100 volt grade , PVC insulated, armoured, heavy duty, size of cable 300 sq mm 3.5 core X 2 runs, Make: Havells/L&T/ legrand.
Supply & fixing MCCB, 400 amps 4 pole. 415 volts, 50 Hz, Breaking capacity 45 KA, frame- HIM400 make: Havells/L&T/ Phillips.
PART-B Schedule of Credit
Unserviceable / condemned Diesel Generating set , AC, 3 Phase, 50 Hz, capacity - 275 KVA with AMF Panel.
Please Enable Macros to View BoQ information
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.49 MB
NIT.pdf
Tender Documents • 1.48 MB
BOQ_938172.xls
BOQ • 0.30 MB
GCC.pdf
Additional Documents • 5.89 MB
Download all tender documents and submit your bid