Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹43.3 LAccepted-AOC HOUSE NO 251 E BLOCK ADARSH NAGAR BALLABHGARH FARIDABAD PIN 121004 HARYANA | FARIDABAD | FARIDABAD | HARYANA | 121004 | ₹43.3 L | L-1 | Accepted-AOC AOC is being Awarded to the lowest bidder |
| 2 | L-2₹44.5 L+₹1.2 L (2.85%)Rejected-Finance | ₹44.5 L+₹1.2 L (2.85%) | L-2 | Rejected-Finance Rejected as other than lowest Tenderer |
| 3 | Rejected-Technical | - | - | Rejected-Technical Similar works submitted for eligibility criteria are not executed at High Altitude Areas, hence rejected as per PQ Criteria Para 1, Note (b) of NIT |
| 4 | Rejected-Technical 61 DANDA KHUDANEWALA NEAR GAS GODAM SAHASTRADHARA ROAD DEHRADUN 248001 | DEHRADUN | UTTARAKHAND | 248001 | - | - | Rejected-Technical Similar works submitted for eligibility criteria are not executed at High Altitude Areas, hence rejected as per PQ Criteria Para 1, Note (b) of NIT |
| 5 | Rejected-Technical H NO 5 117 BODUPPAL INDIRA NAGAR COLONY GHATKESAR MANDAL R R DIST 500 092 | MEDCHAL MALKAJGIRI | TELANGANA | 500092 | - | - | Rejected-Technical Similar works submitted for eligibility criteria are not executed at High Altitude Areas, hence rejected as per PQ Criteria Para 1, Note (b) of NIT |
Tender Value
₹43.7 L
EMD Value
₹87,408
Closing Date
27 Jan 2026, 3:00 pmClosed
CCE R N D ESTATES NORTH CHANDIGARH
CCE R N D ESTATES NORTH M-1026 Sector- 29A, Chandigarh - 160030
REPLACEMENT OF DIESEL GENERATING SET AC, 3 PHASE, 50 HZ, CAPACITY 320 KVA WITH AMF PANEL AT 19 CD ITM, MUSSOORIE
2026_DRDO_892570_1
CCE(EN)/DDN/DG SET/19 CD/ITM/25-26/11601A
Open Tender
Miscellaneous Works
Percentage
300 days
ITM Mussoorie
All agencies enlisted with DCWandE, New Delhi in Composite Category of CC-IV Rs.60 Lakhs and above DCWandE, Enlistment Estate Management and Maintenance (DRDO-2024) under BIM-I, BIM-II, BIM-III and BIM-IV Categories are eligible with PQ Criteria.
4 documents required · 4 mandatory
₹0
₹87,408
D ESTATES NORTH CHANDIGARH
1 Apr 2026
6 Jan 2026
28 Jan 2026
6 Jan 2026
27 Jan 2026
14 Jan 2026
12 Jan 2026
PART-A ELECTRICAL WORKS
Supply, installlation, commissionig & testing of Silent Diesel Generating set, AC, 3 Phase, 50 Hz, capacity 320 KVA/256 KW with CPCB IV+ approved accoustic enclosure, radiator cooled , diesel engine devloping 395 BHP at 1500 RPM, complete with standard accessaries, coupled to alternator rated at 320 KVA/256 KW, 415 volts, mounted on channel iron base frame, complete with fuel tank of capacity 615 ltrscapacity & DEF tank of 60 ltr capacity with AMF Control Panel including 2 Nos 12 Volts rechargeable lead acid battery of suitable AH as directed by Engineer-in-Charge including disconnecting serviceable LT UG cables from existing LT panel board & old DG Set etc and reconnecting to new DG Set & AMF panel as required and directed at site complete. Generator Set Specifications: Prime, Power Rating -320 KVA/ 256 KW, 3 phases , Out put voltage & frequency (V & Hz) - 415 V, 50 Hz, power factor - 0.8 (Lagging), Current (A) -445 Amps. Engine Specifications: Required certified power for rated KVA (hp) - 395, Cooling- liquid cooled (EG compleat 50-50), DEF- AUS 32 (Premix) as per ISO22241, Aspiration, turbocharged, charge air cooled, nos of cylinders- 6, In-line, Bore(MM) x stroke(MM) - 114x145, Compression ratio - 16.7 : 1, displacement Ltr - 8.9, Fuel - High speed Diesel, Performance class of DG Set, ISO 8528-5 G2, starting system- 24 volts DC electrical, Lub oil specification- CK4, Lub oil sump capacity , High- Low level (in Ltr) - 30- 19.7 ltr, Total lub oil system capacity - 31.7 ltr, Exhaust pipe size (in inch)- 6 , Total weight(engine + radiator) - 918.2 Kg, Length x widthx height ( in MM) - 1128 x791x 1277, Mean piston speed (m/s) - 7.2 , Combution air intake @100 % load (+-5%) - 689 CFM, Exhaust temperature (*C) - 539 *C. All as approved by Project Manager / Engineer-in-Charge.
Alternator Specifications: Alternator suitable for continuous operation generating 320 KVA at 1500 RPM, 415 Volts, 0.8 power factor (lag) suitable for 50 Hz, 3 phase, 4 wire system, confirming to BS 5000 / IS 4722. The alternation is brushless type, screen protected, revolving field, self-excited, self-regulated through an AVR. The alternator has the following features: - - + 1.0% voltage regulation (max.) in static conditions. - IP: 23 protection with insulation class H. - Permissible overload of 10% for one hour in 12 hours of operation.
Supplly and fixing LT UG cable with aluminium conductor, 1100 volt grade , PVC insulated, armoured, heavy duty, size of cable 300 sq mm 3.5 core X 2 runs, Make: Havells/L&T/ legrand.
Supply & fixing MCCB, 400 amps 4 pole. 415 volts, 50 Hz, Breaking capacity 45 KA, frame- HIM400 make: Havells/L&T/ Phillips.
PART-B Schedule of Credit
Unserviceable / condemned Diesel Generating set , AC, 3 Phase, 50 Hz, capacity - 275 KVA with AMF Panel.
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.49 MB
NIT.pdf
Tender Documents • 1.48 MB
BOQ_938172.xls
BOQ • 0.30 MB
GCC.pdf
Additional Documents • 5.89 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .